Bio-Cascade, Inc Clean Air and Water Systems Distributors and Service Providers for: Clean Air Plant (CAP ©) and Clean Water Plant (CWP ©)
Technology Background Dr. Sam Sofer PhD, PE; Principal engineer and inventor of the bio-hygienic products produced by the company. Air and Water Solutions Inc. based in NJ. Headquarters for manufacturing, research and development.
How CAP/CWP works Humans and animals consume food therefore capturing the energy from the food source and reducing it to carbon dioxide,water and solids. Biological Oxidation is a natural reaction where micro-organisms capture the energy in an organic substance (food source) and use it for the oxidation process. Technology : Biological Oxidation
This allows biological oxidation to take place without a large increase in temperature or energy usage. The results of this are CO2, water and inert bio-solids. As contaminants come in contact with micro- organisms, they are biologically oxidized to CO2 and water. Heavy metals and solids are consolidated and rendered harmless. Biological Oxidation (continued)
Bio-hygienics Contaminants and odors that are persistent travel on particulates. Most large particles will travel with air flow and can be vented. Small particles, the ones which are most harmful, are resistant to normal air flow and cannot be vented. (bi'o-hi jen'ikx); The application of compact treatment plants utilizing bio-oxidation for indoor and outdoor applications
These particulates are electrically charged. Their motion is controlled by electrical fields not by air flow. For these reasons, many odors linger even when an area is exhausted. CAP© neutralizes contaminants in the air and creates an electrically neutral “clean zone.”CAP© neutralizes contaminants in the air and creates an electrically neutral “clean zone.” Bio-hygienics
Contaminants, both positively and negatively charged, are attracted to this neutral clean zone, where they are captured in the unit and biologically oxidized. CWP© work the same way, creating a clean water zone. Contaminants move to the clean zone, are drawn into the unit, where they are biologically oxidized. Bio-hygienics (continued)
Substantial cost savings Superior technology to –Carbon - substantially more economical –Thermal destruction –Removes and digests small particles and more that HEPA cannot handle. Single technology, single solution Very low maintenance Can be installed modularly to meet growing demands
Save on energy by reducing or eliminating costly venting and air exchange! CAP systems are fully sustainable “Green” Technology! Help environmental efforts!
Technology will eliminate nuisance odor and hazardous problems including : Anatomy labs Waste transfer and treatment plants Diesel and gasoline fumes Carbon Monoxide Mold and other spores Paint fumes. (Paint will even dry faster!) VOC’s Particulates Hair and nail salon fumes And much more…
CWP for real solutions to waste water discharge regulations. More economical than conventional treatments CAPs and CWPs are the only 100% bio-systems that address air and water contaminants.
CAP can even be customized to help reduce power plant emissions!
Real Data
Machine Operation The CAP™ Machine is can be modified to fit both stationary and portable applications. The size of the machine is based on both area covered and amount of pollution present Dual outlet power supply to run pump and fan.
Water must be added as needed(daily in most cases). Automatic water feed can be installed on larger machines. Heaters can be added for exterior applications to prevent water freeze. CAP™ requirements for normal operation
BioOx © is the Bio-Enzyme microbial media used to consume pollution. Start up recommendations and amount used during normal operation are based on machine and application. (Chart to come later in presentation). BioOx added monthly or more frequently as needed. Bio-Ox® Natural Media
The more pollution,the more BioOx needed. Many applications will need less BioOx the longer the machine has been operating as it will clean the air and built up pollution in walls, ceiling tiles and ventilation systems.
Trash Transfer Station Applications CAP 5000 with Rodent Intake Guards CAP ™ 5000
Can be made portable Will cover up to 3,000 sq.ft. 10 lbs. of pollution per day CAP ™ 90
CAP ™ 600 Covers areas over 5,000 sq.ft. Destroys up to 60 lbs. of pollution per day Interior and exterior applications
Compare Indoor Air Cleaners Type CleanerGasesVOC’SParticulatesBio-HygienicsSafety Ozone Ionizer UV HEPA (all air filters) Carbon Canister CAP Technology Evaluation Table for Indoor Air Cleaners
CAP™ Machine Specifications ModelEquiv. Flow Rate (cfm) Pollution Destruction (lbs/day)* BioOx ® Usage Size & Weight (US) Power Consumption Area Model Cleans Typical Application NEW CAP oz startup 2 oz/week for 2 mos. Thereafter 2 oz/month 12” sq x 15” 18 lbs 30 W Up to 800 ft 2 Room, office NEW CAP oz startup 4 oz/week for 2 mos. Thereafter 4 oz/month 12” sq x 20” 20 lbs 30 W Up to 1500 ft 2 Small house, office NEW CAP oz startup 4 oz/week for 2 mos. Thereafter 4 oz/month 12” sq x 24” 25 lbs 30 W Up to 2000 ft 2 Medium office, garage, shop, salon, schoolroom CAP-90 Industrial Model oz startup 4 oz/week for 2 mos. Thereafter 4 oz/month 15” sq x 32” 35 lbs 40 W Up to 3000 ft 2 Office, plant, garage, commercial & small industry
CAP™ Machine Specifications (continued) ModelEquiv. Flow Rate (cfm) Pollution Destruction (lbs/day)* BioOx ® Usage Size & Weight (US) Power Consumption Area Model CleansTypical Application CAP gal. startup 16 oz/week for 2 mos. Thereafter 16 oz/month 30” dia x 48” 26” at base 200 lbs 175 W Units designed to handle commercial and industrial areas of 5000 ft 2 and larger, with heavy pollution load Small-medium industry, plant, warehouse, lab, loading dock, restaurant, bar, hotel, parking garage CAP gal. startup 48 oz/week for 2 mos. Thereafter 48 oz/month 36” dia x 50” ” fan housing 300 lbs 438 W Industry, plant, terminal, indoor/outdoor, heavy pollution CAP gal. startup ½ gal./week for 2 mos. Thereafter 64 oz/month 52” dia x 50” ” fan housing 500 lbs 500 W CAP-X Series (all models above) All environments. Specifically designed for extremely concentrated and toxic air contaminants Concentrated discharges from mixers, reactors and other similar equipment
CWP™ Machine Specifications ModelEquiv. Flow Rate (gpm) Pollution Destruction (lbs/day)* BioOx ® Usage Size & Weight (US) Power Consumption Area Model Cleans Typical Application CWP oz./mo. Startup: 16 oz. Then 4 oz/week for 2 mos. 12” sq x 20” 30 lbs Small, compact and portable For sinks, fish tanks, ponds. Small space applications CWP oz/mo. Startup: 32 oz. Then 8 oz/week for 2 mos. 12” sq x 20” 20 lbs 30 W Small-scale industry, industrial wastewater, waste tank contents, fuel- contaminated home sumps or direct treatment of ground water CWP-SVE oz/mo. Startup: 1 gal. Then 16 oz/week for 2 mos. 30” dia x 8” 100 lbs Saves on carbon costs For industrial applications, fish tanks, wells, ponds, small lakes.
CWP™ Machine Specifications (cont.) ModelEquiv. Flow Rate (gpm) Pollution Destruction (lbs/day)* BioOx ® Usage Size & Weight (US) Power Consumption Area Model Cleans Typical Application CWP oz./mo. Startup: 1 gal. Then 24 oz/week for 2 mos. 36” dia x 48” 250 lbs. Cleans large amounts of liquid. Designed for sudden increase in flow. Wastewater, chemical waste streams, waste tank contents. Large volume streams or surface water runoff. Direct treatment of groundwater. CWP oz./mo. Startup: 2 gal. Then 48 oz/week for 2 mos. 36” dia x 50” 250 lbs. CWP oz./mo. Startup: 3 gal. Then ½ gal./week for 2 mos. 52” dia x 50” 350 lbs. CWP gal./mo. Startup: 10gal. Then 1 gal./week for 2 mos. 72” dia x 84” 600 lbs.
For more information or to contact us: