PVD100 ‘Point Velocity Display’ Kota Samarahan Kuching, Sarawak July 2008.

Slides:



Advertisements
Similar presentations
WHIRLPOOL Vertical modular Washer
Advertisements

Tuono Dashboard and immobilizer new features 1 2 Dashboard
Tandberg MXP Training Version 1.1, By David Anstee, First Connections Ltd.
Crown CDi Series Control Click the Crown Logo at the top of any the screen to return to this Menu Interactive Main Menu Interactive Front Panel Display.
DP-IR Detecto-Pak Infrared
Hornet Cableway Gauging Systems Set Up and Use Department of Primary Industries and Water Hobart, Tasmania 31 st August 2009.
JED Microprocessors Pty Ltd Presenting the JED T430 low-cost Projector Controllers Nov 22nd, 2009.
Remote set-up instructions Life is meant to be interactive!
(PLEASE SWITCH TO THE SLIDE SHOW MODE)
GE job title/1 GE internal information - Not for external distribution 1 GE Security EMEA NPI template – v1 1X Series (phase 1) Conventional Fire Panel.
Troubleshooting Training Course.  Visual and General Test  Perform System Test (Mode  Perform System Test)  Identify The Error  If you need Technical.
LogTag Training January 2015
Projector Controllers
WALTON SMART SOLUTIONS Audio-Video-Technology Systems Integration Specialists 1 WAB Standardized Classroom WAB Standardized Classroom from ICT has a new.
Unit Test Calibration Training
Crown DSi Series Control Click the Crown Logo at the top of any the screen to return to this Menu Interactive Main Menu Interactive Front Panel Display.
BE-2110i VF/WIDEBAND TRANSMISSION TEST SET OPERATING OVERVIEW Slide 1 of 9.
Rotary Encoder. Wikipedia- Definition  A rotary encoder, also called a shaft encoder, is an electro- mechanical device that converts the angular position.
Pneumatic Road Tube Counters Version 3.0
© 2008 Masimo Corporation Includes a review on Carbon Monoxide Poisoning For Emergency Responders V.8 1 May 2011 Monitoring CO Poisoning with the Rad-57.
Familiarization and Operation
Clean Air Box Usage & Care CABs RAMs CO Monitors.
DIGITAL LIGHT METER Dr. Lim Jac Fang Occupational Health Doctor Department of Health, Sabah 1994 CT Lutron LX-105 LIGHT METER.
Fluke thermometer 54II Press green button to turn the thermometer on or off. If it does not turn on replace batteries.
DataLogger Operation - 1 DataLogger ® Operation Procedures.
2001, 2002 & 3012 Series Operation 2001, 2002 & 3012 Series Operation (See Installation and Operation Manual for detailed instructions)
GPS. Meet the Bad Elf GPS Pro The Bad Elf GPS Pro offers the first Apple approved GPS with an informative user interface.
AccuMax Multi-Point Injection Mechanics
SXBlue II GPS CHAPTER – I ABOUT HARDWARE AND SOFTWARE.
Gates Professional Development Series Gates Sonic Tension Meter 507C NEW! Measures Tension in BothV-BeltsAnd Synchronous Belts.
The New Adventurer Pro Is Here!. What’s New? Bright alphanumeric dual line display Better weighing cell and weighing performance 7 application modes Better.
Introduction ► Scope:- Service Diagnostics Routines can use for XXL, Side by Side products with STEALTH user interface with single evaporator fan product.
AVL USER GUIDE (GSM) Automatic Vehicle Locator Manual Korea 위치정보통신 TEL: FAX:
Cypress-Fairbanks I.S.D. 04/04/05 PC6 Word Processor Training Assistive Technology
TrekView DMS Instructions. 1. Log in to TrekView DMS.
Doc. Ver. : V1.10 Feb., R&D Center Union Community Co., Ltd. Doc. Ver. : V1.10 Feb., R&D Center Union Community Co., Ltd. Installation &
1 PAC530 | Output Controller. 2 The Output Controller (PAC530) provides the local connection on an RS-485 network between an Access and Alarm Server (PAC500)
Color Sensors We Know Until Now, Our History with Color Sensing Technology has Been Limited to a Class of Sensors Known as “Color Mark” Sensors Our Offerings.
World Leader In Gas Detection & Sensor Technology Stand Alone Calibration Station SM 2000 Series.
Wireless Remote Controller (MR-AH01/BH01) HQ SE.  On/Off control  Air flow control  Temperature setting  Filter reset  Louver Control  Simple ON/OFF.
© 2008 Masimo Corporation RAD-57 EMS Carry Case Lightweight: 13 oz. Small: 6.2” x 3.0” x 1.4” Portable: operates on 4 “AA” batteries Supplied with high-visibility,
Model 1621M Trainer’s Guide. General Overview Model 1621M is a Geiger Meuller based Personal Radiation Detector (PRD) Complies with ANSI Used for.
OPL MRR Viewer Tutorial David Stark North Carolina State University 31 Jan 2008.
Scout Pro Training Introducing the Scout Pro Portable Balance: 7 Models From 200g x 0.01g to 6000g x 1g 5 Application Modes Optional USB or RS232 Interface.
Gauge Operation and Software by Scott A. Ager. Computer Recommendations 750 MHz Pentium III 64 Meg SRAM 40 Gig Hard Drive 1024 x 768 graphics CD Writer.
GCS 300 System Operation Application – Level 1.
Home Guard Security System. Introduction & Basic Ideas Home Guard Security System.
Engineer Training Pneumatic System Overview. Engineer Training Confidential 2 Working Concept Overview: The Pneumatic System is comprised of:  Y Pistons.
COMPARISON OF VARIOUS TYPES TypeFunctions CMC Sp Pulse + time + velocity PVD100 Hydromate CMC3 Pulse + time + velocity + discharge.
1. Enter service mode and scroll to the Calibrate menu option What is Rider Calibration? This feature enables a rider to calibrate the Watt sensor before.
Experts in Chem-Feed and Water Treatment beta Metering Pumps 1.
Overview of MSWS Control of 212-LC July 15, 2006.
TrueSTEAM™ Humidification Systems Module 6: User Interface.
Service Section Technical Training December 2005.
World Leaders in Combustion Management Solutions End User Guide Lockout Codes Pressure Sensors Error Codes Flame Safeguard UV.
Puissant Panel User Training Esc.. 09:11:35 ACTIVE # * 3 6 RESET SYSTEM CLEAR DISPLAY TEST DISPLAY SILENCE BUZZER ESCAPE ENTER SILENCE.
 Follow the steps in order to solve the sync issue with the best fitness trackers;best fitness trackers  1. Reboot your Fitness Tracker and the device.
AEON 4000 Including the SMPS 4000 rectifier and the AEON Gold Alarm & Monitoring Unit.
BUILDING LOAD NORMAL OPERATION 1. ATS are in normal position connected to utility source 2. All generator set paralleling circuit breaker open.
Quick Start Guide for Flex Flow Pump
How to SWIVl: Using a Gen 2 SWIVL RObot
IN SAMPLE PUMP INNOVATION
Yeti 400 Reprogram SOP 5/1/2017, Yeti firmware rev. 2.0.
Call to Fix Canon Pixma MX340 printer Error 5200
Call to Fix Brother Printer in Error State
Instruction Manual Specifications Features: Dimension:38*16*6 mm
G&H Radiometer/Photometer Reset Notes
Presentation transcript:

PVD100 ‘Point Velocity Display’ Kota Samarahan Kuching, Sarawak July 2008

FEATURES Senses and displays velocity counts AND velocity Senses and displays velocity counts AND velocity ‘Cleans’ and ‘Filters’ signals from cat’s whisker type current meters Top Set Rod version available (CMCSp)Top Set Rod version available (CMCSp) Powered by 2 type ‘AA’ alkaline batteries Powered by 2 type ‘AA’ alkaline batteries Two modes of operation – ‘Slow’ and ‘Normal’ ‘Bluetooth’ mode option‘Bluetooth’ mode option Stores calibration equations for up to 2 fans with 3 equations per fanStores calibration equations for up to 2 fans with 3 equations per fan

Hardware Connections ON / OFF button Fan connection (banana type plugs) Options ‘select’ button Menu button RS232 Interface Count LED Status LED

LED Features ‘STATUS’ LED - Green indicates ‘magnetic head’ type meter‘STATUS’ LED - Green indicates ‘magnetic head’ type meter - Red indicates ‘cat’s whisker’ type meter - Red indicates ‘cat’s whisker’ type meter - Blue indicates ‘Bluetooth’ mode in operation - Blue indicates ‘Bluetooth’ mode in operation ‘COUNT’ LED - flashes upon each fan revolution ‘COUNT’ LED - flashes upon each fan revolution - indicates ‘Meter Dwell’ function - indicates ‘Meter Dwell’ function - indicates faults - indicates faults

Main Display Indicates total counts during a measurement Indicates velocity setting (N = normal : S = slow) Indicates meter contact type (M=magnetic : C = cat’s whisker) Indicates total elapsed time during a measurement M XXX 40 N XXX.XX * M XXX 40 N XXX.XX * M XXX 40 N XXX.XX * M XXX 40 N XXX.XX *

Main Display (cont.) Indicates current meter fault Indicates timing interval (10 sec increments from 10 to 90 secs) M XXX 40 N XXX.XX * M XXX 40 N XXX.XX *

Main Display – Set for ‘Counts’ M XXX 40 N XXX.XX * M = Mag Head C = Cats Whisker Contact Counts Measuring Interval in Secs 0 = Continuous N = Normal Speed S = Slow Speed Elapsed Time in Secs Blank = OK * = Fault Detected

Main Display – Set for ‘Velocity’ X. XX f 40 N XXX.XX * Units: f = feet/sec m= meters/sec Velocity: -in meters: X.XXX m -in feet: X.XX f Measuring Interval in Secs 0 = Continuous N = Normal Speed S = Slow Speed Elapsed Time in Seconds Blank = OK * = Fault Detected

Menus Select ‘Normal’ or ‘Slow’ mode Select ‘Feet’ or ‘Metres’ Select ‘Maghead’ or ‘Cat’s Whisker Select ‘Velocity’ or ‘Counts’ Select ‘Velocity’ or ‘Counts’  VELOCTY COUNTS  FEET METERS  MAGHEAD CATWSKR  NORMAL SLOW

Menus (cont.) Blue LED flashes every 2 seconds Press ‘Function’ then ‘Select’ to toggle between ON/OFF settings Press ‘Function’ then ‘Select’ to increment time to desired setting Press ‘Function’ then ‘Select’ to increment time to desired setting TIME  40 SEC  OFF - BT ON COM  BLUTOOTH DISCOVER  CONNECTD Illuminates once connected then jumps to main display

Menus (cont.) Checks ASCII data transmission Checks serial port connection to an external device Checks connectivity between the PVD100 and current meter Checks connectivity between the PVD100 and current meter Checks signal from current meter (cat’s whisker type only)  CALIBRT YES  COMTEST YES  SER PORT TEST  DWELL? YES

Spin Test Press ‘Select’ when fan stops spinning Connect current meter, spin fan and press ‘Select’ Press ‘Function’ button and ‘Select’ spin option Press ‘Function’ button and ‘Select’ spin option ‘Spin’ = total number of revolutions : ‘Finl’ – total elapsed time  SPIN ? YES  SPIN 0 TEST 0  SPIN 270 FINL 243

Fan Equations Equation number 2 Equation number 1 Fan ‘A’ Serial number details Fan ‘A’ Serial number details Equation number 3  A=S/N  1:  2:  3: ‘Hyper Terminal’ used to input fan equations

Sample Fan Calibration Report HYDROLOGICAL SERVICES PTY. LTD., AUSTRALIA CERTIFICATE OF CALIBRATION Date: 27/4/ Current Meter Model: xxxxxx Serial No Fan No. 1 Serial No Diameter: 125mm Pitch: 0.25m Type of Support: Method of Calibration: Average Value Equation n < 0.42 V = n m/s 0.42 < n < 3.73 V = n m/s n > 3.73 V = n m/s Starting Velocity = m/s Maximum Velocity = m/s Note: 'n' denotes the number of revolutions of the propeller per second 'V' is the water velocity in meters per second. Range Values SlopeIntercept

Battery Replacement 1.Open both side panels 2.Remove and discard old batteries 3.Install 2 x ‘AA’ alkaline batteries Holding ‘ON/OFF’, ‘Select’ and ‘Function’ buttons simultaneously will re-set PVD100

Questions?