Hanover-Fair 2002 IEC The world-wide standard for communication in substations HM IEC Substation Protocols Benefits Customer Video Outlook Communication in the Substation Domain one world one technology one standard IEC 61850
Hanover-Fair 2002 IEC The world-wide standard for communication in substations HM IEC Substation Protocols Benefits Customer Video Outlook Single line diagram of a Substation MVHV Line feeder Transformer busbar coupler busbar coupler Line
Hanover-Fair 2002 IEC The world-wide standard for communication in substations HM IEC Substation Protocols Benefits Customer Video Outlook Typical Substation Automation System Station bus Process bus Station Gateway Central Functions HM I Bay controlProtection Processinterface Bay control Protection & Control
Hanover-Fair 2002 IEC The world-wide standard for communication in substations HM IEC Substation Protocols Benefits Customer Video Outlook Example: Protection 1 and Protection 2 from different manufacturers Central Functions HM I Processinterface Process bus Station bus Bay controlProtection Bay control Protection & Control Protection 1 Protection 1 Protection 2 Protection 2 Station Gateway
Hanover-Fair 2002 IEC The world-wide standard for communication in substations HM IEC Substation Protocols Benefits Customer Video Outlook Today: Different Protocols DNPLON / FIELDBUS MODBUS PROFIBUS Protection 1 Protection 1 Protection 2 Protection 2 Station Gateway Central Functions HM I Processinterface MVB,CAN others Protection & Control
Hanover-Fair 2002 IEC The world-wide standard for communication in substations HM IEC Substation Protocols Benefits Customer Video Outlook Ideal ? MODBUS FIELDBUS MVB proprietary DNP LON PROFIBUS / UCA2
Hanover-Fair 2002 IEC The world-wide standard for communication in substations HM IEC Substation Protocols Benefits Customer Video Outlook The Goal: A global Standard IEC EPRI-Project UCA.2 Experience with IEC and -6 Global consideration Needs Experience Know-how The international Goal
Hanover-Fair 2002 IEC The world-wide standard for communication in substations HM IEC Substation Protocols Benefits Customer Video Outlook IEC 61850: Cost Advantages One Protocol for all the needs in the substation flexible configuration no gateways required Quicker project execution comprehensive data model clear, standardised project- and equipment description Configuration of substation in XML Efficient maintenance robust data modelling self-descriptive equipment automation-configuration in XML
Hanover-Fair 2002 IEC The world-wide standard for communication in substations HM IEC Substation Protocols Benefits Customer Video Outlook IEC 61850: A Future-proof Investment ETHERNET & TCP/IP adopted worldwide scalable technology common use of infrastructure Innovation & Expansion firm rules for the description of new data- objects and functions interoperability is maintained Separation from Application und Communication data and application stay secure independent from communication- systems unconstrained further development of the technology
Hanover-Fair 2002 IEC The world-wide standard for communication in substations HM IEC Substation Protocols Benefits Customer Video Outlook Terna - the Company Terna is the Enel’s Group high voltage transmission system owner (95% of the total Italian grid) km transmission lines 267 Substations 1 Headquarter 10 Business Units 60 Operating Groups (O&M) Scalable range of business services
Hanover-Fair 2002 IEC The world-wide standard for communication in substations HM IEC Substation Protocols Benefits Customer Video Outlook Terna’s Expectations for the SICAS-System using IEC61850 Economy Best cost/performance Plant control Manufacturers certification Functionality Backward Compatibility Integration with remote control Simplification/Streamlining Bay/Station standard concepts SICAS Technology Distributed Intelligence Standard Hardware Standardised protocol with IEC61850
Hanover-Fair 2002 IEC The world-wide standard for communication in substations HM IEC Substation Protocols Benefits Customer Video Outlook IEC SICAS Roadmap First digital approach (STADIO 99) Starting SICAS Specifications (2001) First tenders/experience SICAS Target architecture/protocols (2002) Manufacturers cooperation (2002) ABB, Alstom, Siemens SICAS communication using IEC61850 Technological architecture improvement (2003)
Hanover-Fair 2002 IEC The world-wide standard for communication in substations HM IEC Substation Protocols Benefits Customer Video Outlook The new RWE about 7,000 employees 185,000 km of electricity network 1,500 communities 130 distributors area 36,800 km² inhabitants 7.4 millions turnover 52,735 M€
Hanover-Fair 2002 IEC The world-wide standard for communication in substations HM IEC Substation Protocols Benefits Customer Video Outlook IEC 61850: Advantages & Expectations for RWE Stability and durability (longer operation life-span) Manufacturer and Application independent Possibility of combining equipment from different manufacturers Good Applicability and Extendibility Investment protection
Hanover-Fair 2002 IEC The world-wide standard for communication in substations HM IEC Substation Protocols Benefits Customer Video Outlook IEC Activities of RWE Net AG active member on the standardisation representation of users‘ interests standards accompanying Project OCIS user-oriented definitions, needs, station modelling Near the completion of the standard, a concrete pilot-project for verifying technical/economical alternative to the present station control technique definition of a ‘compatible‘ process bus generality in the sense of sTCA (Seamless Telecontrol Communication Architecture)
Hanover-Fair 2002 IEC The world-wide standard for communication in substations HM IEC Substation Protocols Benefits Customer Video Outlook Statement from American Electric Power Video Clip : Please follow the separate link on the ‘presentations’ site John Burger, principal engineer of AEP responsible for substation automation communication AEP largest utility in US looking for interoperabel solutions for more than 6 years supporting the utility initiative for UCA will switch to IEC61850 if this global standard is ready
Hanover-Fair 2002 IEC The world-wide standard for communication in substations HM IEC Substation Protocols Benefits Customer Video Outlook IEC Time-scale “Final drafts International Standard” “International Standard” ABB, ALSTOM, SIEMENS with the first interoperable products on the market IEC Common work on the standard and on the interoperability one world one technology one standard “Committee Drafts for vote”
Hanover-Fair 2002 IEC The world-wide standard for communication in substations HM IEC Substation Protocols Benefits Customer Video Outlook INTEROPERABILITY One manufacturer… private Two manufacturers… by chance Three manufacturers … interoperability !