by Dr.K.Balamurugan Group leader (R&D)

Slides:



Advertisements
Similar presentations
Introduction to Chromatography
Advertisements

Gas Chromatography.
Gas Chromatography Introduction 1.) Gas Chromatography
Gas Chromatography.
Chromatography.
Standard Data Analysis - Integration
Quantification – Concepts and Integration
Chromatographic Process Provides the analyte transport. Immobile phase. Mixture of components dispersed in the mobile phase.
1 1. Introduction H: High P : Performance (Pressure) L : Liquid C : Chromatography GC : Gas chromatography TLC: Thin layer chromatography IC : Ion chromatography.
Introduction to Chromatographic Separations Due to lack of analytical specificity, separations are often necessary Chromatography is about separations.
Chem. 31 – 4/15 Lecture. Announcements I Exam 2 – Hope to have graded by next Monday Lab Reports –AA report now due Monday, 4/20 (best to try to complete.
World Health Organization
The geometry of capillary columns is fairly simple, consisting of length, internal diameter, and stationary phase thickness. Nevertheless, there are endless.
Chapter 26 An Introduction to Chromatographic Separations
Chem. 133 – 5/5 Lecture. Announcements Lab Report 2.4 due Thursday – can turn in today for reduction of late penalties Term Project Progress Report –
Intro to Chromatographic Separations Chap 26. Originally based on separation and identification by color Originally based on separation and identification.
CHAPTER 29 Supercritical Fluid Chromatography The mobile phase is a supercritical fluid (a fluid above its critical T and critical pressure) Supercritical.
Chapter 6 - Chromatography
Questions From HW.. 1. The Zn in a g sample of foot powder was titrated with mL of M EDTA (Y 4- ). Calculate the percent Zn in this.
Created with MindGenius Business 2005® Performance parameters (Advanced) Theoretical Plate Model Performance parameters (Advanced) Theoretical Plate Model.
Chemical Ideas 7.6 Chromatography. The general principle. Use – to separate and identify components of mixtures. Several different types - paper, thin.
The following minimum specified ranges should be considered: Drug substance or a finished (drug) product 80 to 120 % of the test concentration Content.
High Performance Liquid Chromatography
ANALYTICAL CHEMISTRY CHEM 3811 CHAPTER 22 DR. AUGUSTINE OFORI AGYEMAN Assistant professor of chemistry Department of natural sciences Clayton state university.
Chromatography Separates components in mixture: Based on - polarity
Chromatography Chapter 6.
1.1 General description - Sample dissolved in and transported by a mobile phase - Some components in sample interact more strongly with stationary phase.
CHROMATOGRAPHY. The general name given to methods by which two or more compounds in a mixture are physically separated by distributing themselves between.
Mass transfer in Gas Chromatography
Chem. 230 – 9/23 Lecture.
INTRODUCTION TO CHROMATOGRAPY
Outline EDTA EDTA Titration Acid Base Properties aY nomenclature
CHROMATOGRAPHY Chromatography basically involves the separation of mixtures due to differences in the distribution coefficient.
Introduction to Chromatography Definition Chromatography is a separation technique based on the different interactions of compounds with two phases, a.
1 An Introduction to Chromatographic Separations Lecture 34.
Quality Assurance How do you know your results are correct? How confident are you?
Gas Chromatography Experiment. Gas Chromatography - Gas Chromatography (GC) is a common technique used to separate and identify volatile organic compounds.
Analytical Separations
Validation Defination Establishing documentary evidence which provides a high degree of assurance that specification process will consistently produce.
Introduction to Chromatography. Introduction Chromatography permit the scientist to separate closely related components of complex mixtures. In all chromatographic.
The Chromatogram  Terms:  Retention time  Peak area  Peak width (at half height, at base)  Peak height  Void time/volume  Adjusted retention time.
Chapter 28 High Performance Liquid Chromatography.
Separation Techniques
Ch 21 – Principles of Chromatography and Mass Spectrometry Ch 22 – Gas and Liquid Chromatography.
HPLC.
HPLC 1. Introduction 1.Introduction  INSTUMENTAL ANALYSIS  PRACTICAL 213 PHC  HPLC.
Lecture 8 Peak Parameters and Quantitative chromatography
Chem. 133 – 5/3 Lecture. Announcements Lab – Term Project Progress Report Due Today – Last Assignments: Term Project Poster and Peer Review Grading (Friday,
Instrumental Analysis (I) HPLC Tutorial 8. Graded presentation Students in groups of 4-5 individuals are asked to prepare a presentation (weight=5% of.
Instrumental Analysis (I)  HPLC Tutorial #7 PHCMt561 – 5 th Sem. Pharm.
Downloaded from کروماتوگرافی CHROMATOGRAPHY Downloaded from
PREPARED BY VAISHNANI BHAVIN M.PHARMA-I (Q.A.). Qualitative error sources in HPLC: Poor separation power. Some special substances from the samples can.
Concept of HETP, HTU and NTU
Experiments in Analytical Chemistry
1.1 General description - Sample dissolved in and transported by a mobile phase - Some components in sample interact more strongly with stationary phase.
High Performance Liquid Chromatography. What is HPLC ? It is a separation technique that involves: Injection of small volume of liquid sample Into a tube.
Chem. 133 – 5/2 Lecture.
Chem. 133 – 5/9 Lecture.
Chromatography- TLC & HPLC
Chem. 133 – 5/11 Lecture.
An Introduction to Chromatographic Separations
Chem. 31 – 11/13 Lecture.
Chem. 133 – 5/4 Lecture.
An Introduction to Chromatographic Separations
Chromatographic performance
BASICS OF SUPERCRITICAL FLUID CHROMATOGRAPHY
Principle of separation of different components:
CHROMATOGRAPHY Chromatography : It is a physical method of separation in which the components to be separated are distributed between two phases, one.
Chromatography is a technique in which the components of a mixture are separated based on The differences in rates at which they are carried through a.
Chromatography is a technique in which the components of a mixture are separated based on The differences in rates at which they are carried through a.
Presentation transcript:

by Dr.K.Balamurugan Group leader (R&D) Peak integration by Dr.K.Balamurugan Group leader (R&D)

INTRODUCTION Peak detection and integration are fundamental tasks in chromatography, most often done using chromatography software. Enabling software to detect and integrate the peaks as desired (or as required by laboratory rules) is challenging. Common challenges in peak detection include: Distinguishing peaks from noise Correctly identifying the underlying baseline Maintaining correct peak and baseline detection throughout a sequence of chromatograms Correctly handling rider peaks and other unresolved peaks

Peak Peak is the name originally used by James and Martin to describe the elution curve of a solute which relates solute concentration in the mobile phase with time. This term was obviously evoked by the Gaussian shape of the elution curve.

Topics 1. Required Integration Events Threshold/slope Width Shoulder Sensitivity Valley to Valley Split Peak Tangent Skim Front Tangent Skim Negative Peak Backward Horizontal Baseline Lowest Point Horizontal Baseline Force Peak Start /Force Peak Stop Horizontal Baseline Minimum Area

2. Interpretation of chromatograms Relative retention times r Theoretical plates N Resolution, R Signal to noise ratio S/N Peak to valley ratio p/v Symmetry factor As Mass distribution ratio (also known as the capacity factor k' or retention factor k)

3. Case study Question to experts

Required Integration Events Threshold/slope Width This parameter is used to allow the integration algorithm to distinguish the start and stop of peaks from baseline noise and drift. When setting the Threshold value graphically, you select a section of baseline. The recommended Threshold value is based on the highest first value determined in that section of the chromatogram. The diagram below shows examples of how incorrect values for peak Width and Threshold can effect the peak baseline.

Threshold/slope Width Note that extreme values of both Width and Threshold (too large or too small) can result in peaks not detected.

The Width event is used to calculate a value for bunching, or smoothing, the data points before the integration algorithm is applied. Integration works best when there are 20 points across a peak

Shoulder Sensitivity This parameter is used to enable the detection of shoulders on larger peaks. A larger value will decrease shoulder sensitivity, while smaller values increase sensitivity to shoulder peaks. When setting the Shoulder Sensitivity value graphically, you select a section of the baseline. The recommended Shoulder Sensitivity value is based on the highest derivative value determined in that section of the chromatogram

Valley to Valley This event causes the baselines of peaks that are not totally resolved (i.e. do not return to baseline) to be drawn to the minimum point between the peaks. If this event is not used, a baseline is projected to the next point at which the chromatogram returns to baseline, and a perpendicular is dropped for peaks which do not reach baseline

Split Peak This event is used to force a perpendicular drop-line integration in a peak. The perpendicular will be dropped at the point where the event is inserted.

Tangent Skim This event is used to integrate a small peak located on the tailing edge of a larger peak. The baseline of the small peak becomes a tangent drawn from the valley of the larger peak to the tangent point on the chromatogram.

Front Tangent Skim The Front Tangent Skim event is used to force a tangential baseline for a daughter peak on the leading edge of a mother peak.

Negative Peak This event causes portions of the chromatogram that drop below the baseline to be integrated using the normal peak logic and reported as true peaks. This event is useful when using detectors such as Refractive Index types which give a negative response to certain compounds.

Backward Horizontal Baseline This event is used to force a horizontal baseline in the direction of the beginning of the chromatogram. A backward horizontal baseline will be created between the times specified by the event.

Lowest Point Horizontal Baseline This event is similar to the Horizontal Baseline event, except that the lowest point in the chromatogram determines the baseline. The values you input for Start Time and Stop Time determine the region within the chromatogram where the lowest point horizontal baseline will be used.

Force Peak Start /Force Peak Stop These events are used to force the start or stop of the peak integration to a specific point.

Horizontal Baseline This event allows you to project the baseline forward horizontally between the times specified for the event.

Minimum Area This event allows you to enter an area limit for peak detection. Peaks whose areas fall below this minimum area will not be integrated and reported as peaks. This event is useful for eliminating noise or unwanted peaks from your report.

INTERPRETATION OF CHROMATOGRAMS

relative retention times In most procedures there is no need to identify an unretained peak, comparisons are normally made in terms of relative retention times, R r :

where t 2 and t 1 are the retention times t M is the retention time of a non-retained marker

Theoretical plates: The number of theoretical plates, N, is a measure of column efficiency. For Gaussian peaks, it is calculated by the equation:

The value of N depends upon the substance being chromatographed as well as the operating conditions such as mobile phase or carrier gas flow rates and temperature, the quality of the packing, the uniformity of the packing within the column and, for capillary columns, the thickness of the stationary phase film, and the internal diameter and length of the column.

Resolution, R: The separation of two components in a mixture, the resolution, R, is determined by the equation:

Where electronic integrators are used, it may be convenient to determine the resolution, R, by the equation:

Signal to noise ratio The signal-to-noise ratio (S/N) influences the precision of quantification and is calculated from the equation:

H = height of the peak, measured from the maximum of the peak to the extrapolated baseline of the signal observed over a distance equal to 20 times the width at half-height, h =range of the background noise in a chromatogram obtained after injection or application of a blank, observed over a distance equal to 20 times the width at half-height of the peak in the chromatogram

Peak to valley ratio The peak-to-valley ratio (p/v) may be employed as a system suitability requirement in a test for related substances when baseline separation between 2 peaks is not reached

Hp =height above the extrapolated baseline of the minor peak, Hv =height above the extrapolated baseline at the lowest point of the curve separating the minor and major peaks.

Symmetry factor The symmetry factor (As) (or tailing factor) of a peak is calculated from the expression:

w0.05 = width of the peak at one-twentieth of the peak height, d = distance between the perpendicular dropped from the peak maximum and the leading edge of the peak at one-twentieth of the peak height. A value of 1.0 signifies complete (ideal) symmetry.

Mass distribution ratio(also known as the capacity factor k' or retention factor k) The ratio of the adjusted retention volume ( or time ) and the hold-up volume ( or time )

Case study Q1 Who and how, one will conclude the selected peak integration parameters (by instrument default or forced by operator) are suitable for a given procedure?? or What data need to be captured wrt peak integration [ where & how is acceptable for authorities

Q2 When a validated analytical method (with a set of integration parameters) is transferred to the plant are we allowed to change the integration parameters, if yes how/where do we record/report them.

Q3 Can we change the integration parameters on daily basis, do we follow change control procedure for this change. 21 CFR Part 11 - Electronic Records and Electronic Signatures http://www.labcompliance.com/tutorial/part11/default.aspx

Q4 If a method is used on routinely is it ok to change/adjust  the peak integration parameters  as required for a given day to meet SS requirements ? if yes why ? Can peak integration parameters be changed during a given analysis?

Q5 detector and software integration parameters where they are stored? how to retrieve it. Is it necessary to be part of method? If no why?

Reference: USP 33 BP 2007 Agilent EZChrom Elite

Thank you