The unintentional irradiation of a live human fetus: assessing the likelihood of a radiation-induced abortion Eduardo Galiano Laurentian University Marcelo.

Slides:



Advertisements
Similar presentations
Radiation safety in CT.
Advertisements

Radiation biology and protection in dental radiology
Pregnancy and Medical Radiation
Radiation safety in CT.
CT Organ Dose - Part 1 Estimating organ dose for patients Michael F. McNitt-Gray, Ph.D., DABR David Geffen School of Medicine at UCLA.
By. RADIATION & PREGNANCY Diagnostic & Therapeutic procedures causing exposure of the abdomen of women likely to be pregnant should be avoided unless.
INTERNATIONAL COMMISSION ON RADIOLOGICAL PROTECTION —————————————————————————————————————— Pregnancy and Medical Radiation.
State of Michigan Computed Tomography Regulations
Radiation Safety Chapter 9 Bushong.
RADIOLOGY. NEXT GENERATION SCIENCE / COMMON CORE STANDARDS ADDRESSED! CCSS.ELA-Literacy.RST Determine the central ideas or conclusions of a text;
Radiation and Pregnancy ©Health Physics Society. Medical X-Ray Exams Radiation exposure that is extra- abdominal will not contribute significant radiation.
RAD309 Patient Dose.
NC HPS Meeting 10/18-19/2001 Boone, NC Recent Advances in CT Technology and Issues of CT Dosimetry T. Yoshizumi 1,2, M. Sarder 1, R. Reiman 1,2, E. Paulson.
1 NEXT 2000: Survey of Computed Tomography (CT) Practice, Workload, Dose Stanley H. Stern, Ph. D. FDA/CDRH Office of Health and Industry Programs Division.
5 th September 2005 Paul Collins Computed Tomography Dosimetry Assessment of Effective Dose in Computed Tomography using an Anthropomorphic Phantom Paul.
1 Development of an FDA CT Organ Dose Handbook Thalia T. Mills, Ph. D. FDA Commissioner’s Fellowship project with Dr. Stanley.
Radiation Exposure, Dose and Relative Biological Effectiveness in Medicine Background Image:
Introduction Three-dimensional gel dosimetry is a novel method for radiation measurement motivated by the need to verify experimentally the doses produced.
PHYSICS IN NUCLEAR MEDICINE: QUANTITAITVE SPECT AND CLINICAL APPLICATIONS Kathy Willowson Department of Nuclear Medicine, Royal North Shore Hospital University.
Radiation Protection in Radiotherapy
TERPSSC 2001Robert M. Gagne OVERVIEW OF DIGITAL IMAGING AND RADIATION PROTECTION ISSUES Robert M. Gagne MICAB/DECS/OST [From: Handbook.
Design and Scheduling of Proton Therapy Treatment Centers Stuart Price, University of Maryland Bruce Golden, University of Maryland Edward Wasil, American.
Saira Ahmad UOG. CAT Scans CAT Scans ( Computerized axial tomography) Topic:
 An individual who performs radiography, radiation therapy, or nuclear medicine technology.
Simulating Potential Layouts for a Proton Therapy Treatment Center Stuart Price-University of Maryland Bruce Golden- University of Maryland Edward Wasil-
Dose Survey in Computed Tomography DS /CM Kampala IAEA/RCA Kampala.
International Atomic Energy Agency L 4 PROTECTION ISSUES IN CLINICAL METHODOLOGY.
Radiation Dosimetry of the Patient
What is CT?  CT scans use x-rays generated from the source that is rotated around the body to create 3 dimensional pictures of the body. What is an x-ray?
Routine Use of Intraoperative Ultrasound Guidance during Intracavitary Brachytherapy Applicator Placement in Cervical Cancer: the University of Alabama.
Incidental diagnosis of diseases on un- enhanced helical computed tomography performed for ureteric colic Author: Nazim A Ahmad1, M Hammad Ather*1 and.
International Atomic Energy Agency Medical exposure in radiology: Justification Module VIII.2: Justification of medical exposures.
Knowledge of radiation exposure in common radiological examinations amongst radiology department staff AL Chang, LH Cope, DH Keane, S Wood Presented by.
IAEA International Atomic Energy Agency RADIATION PROTECTION IN DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY L14: Radiation exposure in pregnancy IAEA Training.
MRI SIMULATION FOR CONFORMAL RADIATION THERAPY OF PROSTATE CANCER Pasquier D 1-3, Palos G 3, Castelain B 1, Lartigau E 1,2, Rousseau J 2,3 1 Department.
CT physics and instrumentation
BEIR VII Implications of the Report for the Future of Medical Imaging G. Donald Frey, Ph.D. Department of Radiology Medical University of South Carolina.
Using Radiation in Medicine. There are 3 main uses of radiation in medicine: Treatment Diagnosis Sterilization.
Reduction of effective and organ dose to the eye lens in cerebral MDCT scans using iterative image reconstruction Zizka J, Jandura J, Kvasnicka T, Klzo.
JUSTIFICATION OF COMPUTERIZED TOMOGRAPHY EXAMINATIONS AND RADIATION RISKS IN EVERYDAY RADIOLOGICAL PRACTICE Darka R. Hadnađev, Olivera Nikolić, Sanja Stojanović.
Radiation Therapy in the Management of Cervical Carcinoma Patrick S Swift, MD Medical Director, Radiation Oncology Alta Bates Comprehensive Cancer Center.
Ye, Sung-Joon, Ph.D. Ove, Roger, M.D., Ph.D.; Shen, Sui, Ph.D.
Rotational Profile of the Lower Extremity in Achondroplasia : Computed Tomographic Examination of 25 patients Hae-Ryong Song, M.D., Keny Swapnil.M M.S,
IAEA International Atomic Energy Agency Optimization of Protection in Computed Tomography (CT)-What can radiographers do? IAEA Regional Training Course.
Pediatric Nuclear Medicine and the RDRC Regulations Michael J. Gelfand M.D. Cincinnati Children’s Hospital Cincinnati, OH Past-President, Society of Nuclear.
The Application of Multi-detector Computed Tomography in RVOT Ablation in BRUGADA’ s Syndrome Paweena Mapinta R.T, Cardiac Imaging Unit, Bangkok Heart.
MEASUREMENTS OF RADIATION DOSES IN MULTISLICES COMPUTED TOMOGRAPHY EXAMINATIONS A. ELMAHDI*, A. SULIEMAN *Presenting author 1 Sudan Atomic Energy Commission,
Part No...., Module No....Lesson No
Visceral Adiposity at Diagnosis Correlates with Tumor Size and Metastatic Progression in Clear Cell Renal Carcinoma A Shuster, MD (1), M Patlas, MD (1),
Issues in diagnosis of VTE in Pregnancy Ng Heng Joo Department of Haematology Singapore General Hospital.
Week 2 :Radiation Protection
What are the dose quantities in CT ? IAEA/RCA Kampala Kampala.
MEDICAL USES FOR RADIATION Andres Perez P.1 Level 4 MT10.
IS THERE A RATIONAL APPROACH TO RADIATION RISK? Philip F. Judy Ph.D. Department of Radiology Brigham and Women's Hospital New England AAPM Chapter Meeting.
Wednesday Case of the Day History: CT pulmonary angiography (image shown) was performed on a 24-year-old female patient with pleuritic chest pain and increased.
Wednesday Case of the Day History: 32-year-old female (approximately standard-sized female) undergoes CT scan of abdomen and pelvis after motor vehicle.
Sunday Case of the Day How does the presence of the object impact patient dose? A. Increases by 20% - 50% B. Increases by 3% - 5% C. No Change D. Decreases.
Organ dose and effective dose in Full spine Eaxamniations by EOS® Stereo-radiography with micro-dose settings. A study on anthropomorphic phantoms describing.
Tomography for Intraoperative Evaluation of Breast Tumor Margins:
The fetal risks from diagnostic use of radiation during pregnancy: a systematic review and proposal of a clinical protocol Mafalda Gomes Degree in Basic.
Patient exposure trends and problems in implementing ALARA
Sunday Case of the Day Physics
Pulmonary Embolism in pregnancy
Evaluation of biologically equivalent dose escalation, clinical outcome, and toxicity in prostate cancer radiotherapy: A meta-analysis of 12,000 patients.
Exhibit Number: C19 Evaluation and Reduction of Head Computed Tomography Dose Because of full frame graphic use title slide sparingly because too many.
Radiation Protection in Dental Radiology
Wednesday Case of the Day
RADIATION PROTECTION IN DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY
Ethical Considerations for Pediatric Clinical Investigations
Presentation transcript:

The unintentional irradiation of a live human fetus: assessing the likelihood of a radiation-induced abortion Eduardo Galiano Laurentian University Marcelo Godin Hospital del Cancer Asuncion Paraguay Jeffrey Frimeth Sunnybrook Medical Centre Toronto

 PURPOSE: To calculate dose accidentally absorbed by a live fetus during diagnostic CT procedure (to mother), and then assess likelihood that premature termination of pregnancy was radiation-induced.  In most jurisdictions, regulations require that any dose misadministration be investigated and documented, to address administrative and medico-legal issues. More so in cases involving individuals from general population (non-patients) unintentionally exposed. These episodes however present investigators with possibility of extracting radiobiological data otherwise impossible to obtain.  The dose to a fetus cannot be measured directly, however estimation methods of reasonable accuracy have been developed based on physical phantom measurements and/or numerical simulations.

Hospital del Cancer, Paraguay

 METHODS: At HCP a 34 y.o. patient underwent CT scan as part of clinical work up for a FIGO stage IIB cervical cancer (means beyond the cervix i.e. uterus). 5 year survival is 65%, frequency at diagnosis is 28%.  Patient found to be approx 12 weeks pregnant. Two weeks later, fetus became non-viable. As precaution, radiotherapy initially excluded for this patient and fetus removed in Wertheim-Meigs procedure. Patient then received 50 Gy of external beam therapy, and 15 Gy of conventional LDR brachytherapy.  Patient suffered episodes of renal insufficiency, and psychoses, and expired approximately 6 mo. after initial consultation, from complications of parametrial metastases (connective and fatty tissues surrounding uterus).

 To address administrative and medico-legal implications, hospital administration referred case to the Physics Department for further dosimetric evaluation. Intent of referral was to determine what role - if any - fetal dose played in the premature termination of the pregnancy.  The fetal dose was determined using Wagner’s CTDI Phantom Dose Reference Model method, based on calculating the dose in single slice of the phantom within the primary beam, and then accounting for the scatter component from the remaining slices. This is somewhat analogous to the concept of FSF in radiotherapy. L. Wagner, et.al., Medical Physics Publishing, Madison, WI (1997).

Anatomical structures clearly visible on the fetus include the calvarium, distal left upper extremity, epyphyseal growth plates of the lower extremities, and both feet.

CT scan clearly showing a 90º rotation of the fetus around the caudo-cephalic axis. Vertebral bodies, upper extremities, and pelvic structures, are obvious.

Multiple Scan Average Dose (Clinical Concept) Determining the dose from multiple slices (scans). Dose profiles from adjacent slices overlap and create a distribution of peaks and troughs. An average of this distribution is the MSAD.

Computed Tomography Dose Index -CTDI (Physical Concept) Average dose (along z-axis) from a series of acquisitions N = number of slices = 32 T = width of one tomographic section = 6mm D(z) = dose profile along the z-axis (obtained experimentally under clinical-like conditions)

CTDI’s are not doses to patients but rather doses to phantoms. 16 cm or 32 cm diameter phantoms are commonly used to simulate doses to pediatric or adult patients.

CTDI c (kVp) vs. Phantom Diameter

 RESULTS: Our estimated absorbed dose to the fetus was 19.3 mGy.  Comfortably below the consensus levels for negligible risk (50–150 mGy). C.H. McCollough, B.A. Schueler, T.D. Atwell, et al., “Radiation exposure and pregnancy: when should we be concerned?” RadioGraphics 27(4):909–917 (2007).  Additionally, this fetus was approximately 12 weeks old at time of exposure thus well past most radiosensitive phase of organogenesis. Within this phase, it is the initial 10 days of pregnancy which are of most concern regarding a possible radiation-induced abortion. E. Hall, “Radiobiology for the Radiologist: 5 th Ed.” Lippincott Williams and Wilkins, Philadelphia, PA ( 2000).  CONCLUSION: Based on these considerations, our best estimate is that the probability of a radiation-induced abortion from this CT scan is extremely small and can be safely ignored. Thus, the premature termination of this pregnancy can be reasonably attributed to other causes.

Part 6. Medical Exposure13 Free blood Kidney ripped off aorta (no contrast in it) Splenic laceration 3 minute CT exam and taken to the operating room. 3 minute CT exam and taken to the operating room.

Part 6. Medical Exposure14 Fetal skull ribs Blood outside uterus Fetal dose 20 mGy Example of justified use of CT in a pregnant female who was in a motor vehicle accident

Additional References 1) J.P. Felmlee, J.E. Gray, M.L. Leetzow, and J.C. Price, Am J Roentgenol 154(1):185–190 (1990). 2) L.M. Hurwitz, T. Yoshizumi, R.E. Reiman, et al., Am J Roentgenol 186(3):871–876 (2006). 3)ImPACT CTDosimetry. Imaging performance assessment of CT scanners. 4) D.G. Jones, P.C. Shrimpton, NRPB R-250. Chilton, England: National Radiological Protection Board (1991). 5) W.S. Snyder, H.L. Fisher, M.R. Ford, et al., J Nucl Med (supp 3):7–52 (1969). 6) Siemens Somatom Spirit CT Application Guide (2007). 7) 10)AAPM Report No. 96: AAPM TG 23 of the Diagnostic Imaging Council CT Committee, January )Nickoloff, Dutta, Lu, Medical Physics: 30, March 2003.