Lecture 14. X-Ray Fluorescence Microscopy. X-Ray Synchrotron Giant x-ray ring located at Brookhaven National Laboratory in Long Island New York. Utilized.

Slides:



Advertisements
Similar presentations
Bragg’s Law nl=2dsinΘ Just needs some satisfaction!! d Θ l
Advertisements

BACKGROUND THEORY AND TERMINOLOGY FOR ELECTRON MICROSCOPY FOR CyberSTEM PRESENTATIONS.
X-Ray Astronomy Lab X-rays Why look for X-rays? –High temperatures –Atomic lines –Non-thermal processes X-ray detectors X-ray telescopes The Lab.
1 SpectroscopIC aNALYSIS Part 7 – X-ray Analysis Methods Chulalongkorn University, Bangkok, Thailand January 2012 Dr Ron Beckett Water Studies Centre &
Synchrotrons A synchrotron is a ring which uses magnets and electrodes to accelerate x-rays or light to nearly the speed of light These extremely bright.
Fire Protection Laboratory Methods Day
Groups: WA 2,4,5,7. History  The electron microscope was first invented by a team of German engineers headed by Max Knoll and physicist Ernst Ruska in.
Stanford Synchrotron Radiation Lightsource Sources and Optics for XAS Apurva Mehta.
Beam stability requirements: experience from the NSLS X1A STXMs Chris Jacobsen Department of Physics & Astronomy Stony Brook University, NY, USA
Chris Jacobsen Department of Physics & Astronomy Stony Brook University, USA Microscopy for biomedical, biofuels, and environmental.
STXM Cat Graves Stöhr Group SASS Talk 09/30/09.
Single Particle X-ray Diffraction - the Present and the Future John Miao Stanford Synchrotron Radiation Laboratory Stanford Linear Accelerator Center.
Scanning Electron Microscope Jamie Goings. Theory Conventional microscopes use light and glass lenses SEM uses electrons and magnetic lenses to create.
The TEM system and components:
Towards X-ray excited optical microscopy (XEOM) for cultural heritage, spectroelectrochemistry, and wider applications Mark Dowsett 1, Annemie Adriaens.
Summary 34 1.Cells follow rules of chemistry; 2.Water is the most abundant substance proteins constitutes most of a cell’s dry mass; 3.Four major classes.
Study of Protein Association by Fluorescence-based Methods Kristin Michalski UWM RET Intern In association with Professor Vali Raicu.
Lecture 3 INFRARED SPECTROMETRY
Interference Diffraction and Lasers
Chapter 5: Wave Optics How to explain the effects due to interference, diffraction, and polarization of light? How do lasers work?
Rayleigh Scattering & Mie Scattering
Surface Characterization Techniques Topics: –Contact Angle Analysis –Light Microscopy –X-ray Photoelectron Spectroscopy (XPS) –Fourier-Transform Infrared.
Microscope.
Common types of spectroscopy
Transmission Electron Microscopy
1 M. Aslam Baig National Center for Physics Quaid-i-Azam University Campus, Islamabad Pakistan
Topic 29: Remote Sensing 29.1 Production and use of X-rays 29.2 Production and uses of ultrasound 29.3 Use of magnetic resonance as an imaging technique.
DOSE, DAMAGE AND RESOLUTION - FUNDAMENTAL LIMITS IN COHERENT X- RAY-DIFFRACTION IMAGING H. Chapman % R. M. Glaeser * S. Hau-Riege % H. He* M. Howells*
1 Lecture: Solid State Chemistry (Festkörperchemie) Part 2 (Further spectroscopical methods, ) H.J. Deiseroth, SS 2004.
Lesson 5 Conditioning the x-ray beam
‘Wet’ Chemical Techniques One technique to analyze the chemistry of a mineral is to dissolve it –Water, Strong acids/bases, hydrofluoric acid, oxidants,
A-LEVEL PHYSICS 15/09/ :49 Medical Physics.
Fluorescence Techniques
BROOKHAVEN SCIENCE ASSOCIATES BIW ’ 06 Lepton Beam Emittance Instrumentation Igor Pinayev National Synchrotron Light Source BNL, Upton, NY.
Nuclear Instrumentation Laboratory Federal University of Rio de Janeiro -BRAZIL X-ray Fluorescence and X-ray Transmission Microtomography Imaging System.
PHYS 430/603 material Laszlo Takacs UMBC Department of Physics
Other modes associated with SEM: EBIC
BIO 224 Intro to Molecular and Cell Biology. Microscopes are tools frequently used in cell biology Type of microscope used depends on the specimen being.
NANO 225 Micro/NanoFabrication Electron Microscopes 1.
Reminders for this week Homework #4 Due Wednesday (5/20) Lithography Lab Due Thursday (5/21) Quiz #3 on Thursday (5/21) – In Classroom –Covers Lithography,
Structural Study of the  12 Virus By:Elizabeth Brown.
Medical Imaging Radiation I. Naked to the Bone: Medical Imaging in the Twentieth Century (Paperback)by Bettyann Kevles Bettyann Kevles E=mc2: A Biography.
Paul Northrup Brookhaven National Laboratory
Molecular Cell Biology Light Microscopy in Cell Biology Cooper Modified from a 2010 lecture by Richard McIntosh, University of Colorado.
NANO 225 Intro to Nano/Microfabrication
Heterometallic Carbonyl Cluster Precursors Heterometallic molecular cluster precursor - mediate transport and growth of nanoscale bimetallic particles.
The SPARX FEL Project a source for coherent radiation production in the soft X-ray energy range.
Electron Energy Loss Spectroscopy (EELS) Suggested Reading: Used electron spectrometer Used TEM Review of theory for elastic + inelastic scattering Examples.
Starter: Microscopes Which image is from the light microsope? How do you know?
Imaging Technology and Staining Techniques CHAPTER 1.3.
Phase Contrast sensitive Imaging
Free-electron lasers Juergen Pfingstner, University of Oslo, October 2015,
X-ray absorption spectroscopy (XAS)
SSRL Workshop, 10/8-9/ STXM and diffraction-imaging - the view from Stony Brook Janos Kirz, Stony Brook University on leave for at the.
Example of the output produced by XRF
Ch 10 Pages ; Lecture 24 – Introduction to Spectroscopy.
Using Technology to Study Cellular and Molecular Biology.
Interaction of x-ray photons (and gamma ray photons) with matter.
Information content: EXAFS, SEXAFS: Bond lengths. Especially useful because these technique probe the local order.
How do we know? Spectroscopy: Experimental Evidence.
Presentation on.  There are many methods for measuring of fiber structure. Such as:  The absorption of infrared radiation  Raman scattering of light.
Energy-Filtered Transmission Electron Microscope (EFTEM)
Polarization Dependence in X-ray Spectroscopy and Scattering
Microscope.
TEM (Transition Electron Microscope)
C. David, IEEE Conference, Rome,
Starter: Microscopes Which image is from the light microsope? How do you know?
Chapter 35-Diffraction Chapter 35 opener. Parallel coherent light from a laser, which acts as nearly a point source, illuminates these shears. Instead.
Volume 110, Issue 4, Pages (February 2016)
Presentation transcript:

Lecture 14. X-Ray Fluorescence Microscopy

X-Ray Synchrotron Giant x-ray ring located at Brookhaven National Laboratory in Long Island New York. Utilized soft x-ray microscopy to visualize chemical groups in paper. ESCA (XPS) with pictures.

The Microscope Scanning Transmission X- ray Microscope (STXM) Operates between the K edges carbon and oxygen with good penetration in samples slightly less than 1μm, therefore well suited for the study of specimens like single biological cells. Can operate under standard conditions or cryo conditions.

The Microscope (2) Soft x-ray microscopy uses X rays with an energy of eV, or a wavelength of about 1-10 nm. X-ray energy (eV). 30nm resolution Only about 1 dozen sychrotron STXMs available worldwide.

Biological imaging Consider penetration distance: 1/ e absorption length for x rays, scattering mean free paths for electrons Water window: Wolter, Ann. Phys. 10, 94 (1952)

X rays Electrons Absorption dominates Inelastic scattering is weak No multiple scattering Inelastic scattering dominates (energy filters) Multiple scattering often present High contrast from small things

Thick samples: photons come out ahead X-rays: better for thicker specimens. Sayre et al., Science 196, 1339 (1977) Schmahl & Rudolph (1990) These plots: Jacobsen, Medenwaldt, and Williams, in X-ray Microscopy & Spectromicroscopy (Springer, 1998)

Phase contrast: even thicker!

Fibroblast reconstruction: Z slices Frozen-hydrated (ethane plunge) 3T3 fibroblast: Y. Wang et al., J. Microscopy 197, 80 (2000)

Analyzing full fluorescence spectra Peaks from trace elements can be on shoulders of strong peaks from common elements. Setting simple energy windows can give poor quantitation. Record full spectrum and do curve-fitting! Wavelength dispersive detectors can help – but often with lower collection solid angle This example: Twining et al., Anal. Chem. 75, 3806 (2003). Also ESRF, elsewhere.

X-ray focusing: Fresnel zone plates Diffractive optics: radially varied grating spacing Largest diffraction angle is given by outermost (finest) zone width dr N as  = /(2 dr N ) Rayleigh resolution is 0.61 /(  )=1.22 dr N Zones must be positioned to ~1/3 width over diameter (10 nm in 100  m, or 1:10 4 )     Diameter d, outermost zone width dr N, focal length f, wavelength :

Fresnel zone plate images R. W. Wood (1898): zone plate figure drawn with a pen and a compass! Photographically reduced

Zone plates by electron beam lithography Electron beam lithography: produces the finest possible structures (other than what nature can be persuaded to make by itself). Many efforts worldwide! M. Lu, A. Stein (PhD 2002; now BNL), S. Spector (PhD 1998; now Lincoln Lab), C. Jacobsen (Stony Brook) D. Tennant (Lucent/New Jersey Nanotech Consortium) JEOL JBX-9300FS: 1 nA into 4 nm spot, 1.2 nm over 500  m, 100 keV 

Zone plate microscopes TXM Incoherent illumination; works well with a bending magnet; exposure time of seconds More pixels (e.g., ) Moderate spectral resolution in most cases: E/(  E)  STXM Coherent illumination; works best with an undulator; exposure time seconds to minutes Less dose to sample (~10% efficient ZP) Better suited to conventional grating monochromator: E/(  E) 

Soft x-ray imaging NIL 8 fibroblast (glutaraldehyde fixed): V. Oehler, J. Fu, C. Jacobsen Human sperm (unfixed): S. Wirick, C. Jacobsen, Y. Shenkin Test pattern: see Jacobsen et al., Opt. Comm. 86, 351 (1991)

Immunogold labeling H. Chapman, C. Jacobsen, and S. Williams, Ultramicroscopy 62, 191 (1996). Fibroblast, antibody labeled for tubulin. More recent work: –C. Larabell et al., LBL/UCSF –S. Vogt et al., then at Göttingen Labels must be comparable in size to optical resolution. Vogt and Jacobsen, Ultramicroscopy 87, 25 (2001) Challenge: how to label without altering cell?

Absorption edges Lambert-Beer law: linear absorption coefficient µ This coefficient makes a jump at specific elemental absorption edges! This example: 0.1 µm protein, silica

U. Neuhäusler (Stony Brook/Göttingen), S. Abend (Kiel), G. Lagaly (Kiel), C. Jacobsen (Stony Brook), Colloid and Polymer Science 277, 719 (1999) Emulsion: water, oil droplets, clay, and layered double hydroxides (LDH) “Caged” part of oil droplet remains fixed; “uncaged” part can disperse X-ray microscopy of colloids 346 eV: calcium weakly absorbing. Clays and LDHs absorb equally eV: calcium strongly absorbing. Calcium-rich LDHs are highlighted. 290 eV: carbon strongly absorbing 284 eV: carbon (oil drop) weakly absorbing

Near-edge absorption fine structure (NEXAFS) or X-ray absorption near-edge structure (XANES) Fine-tuning of the x-ray energy near an atom’s edge gives sensitivity to the chemical bonding state of atoms of that type First use in microscopy: Ade et al., Science 258, 972 (1992)

C-XANES of amino acids K. Kaznacheyev et al., J. Phys. Chem. A 106, 3153 (2002) Experiment: K. Kaznacheyev et al., Stony Brook (now CLS) Theory: O. Plashkevych, H. Ågren et al., KTH Stockholm; A. Hitchcock, McMaster

Spectromicroscopy by image stacks Acquire sequence of images over XANES spectral region; automatically align using Fourier cross-correlations or laser interferometer; extract spectra. C. Jacobsen et al., J. Microscopy 197, 173 (2000). Images at N =150 energies are common.

DNA packing in sperm X. Zhang, R. Balhorn, J. Mazrimas, and J. Kirz, J. Structural Biology 116, 335 (1996) DNA packing in sperm mediated by protamine I and protamine II; fraction of protamine II can vary from 0% to 67% among several species Bulk measurements: compromised by immature or arrested spermatids Images at six XANES resonance energies for each specimen

“Sperm morphology, motility, and concentration in fertile and infertile men” Guzick et al., New England Journal of Medicine 345, 1388 (2001) “Although semen analysis is routinely used to evaluate the male partner in infertile couples, sperm measurements that discriminate between fertile and infertile men are not well defined… Threshold values for sperm concentration, motility, and morphology can be used to classify men as subfertile, of indeterminate fertility, or fertile. None of the measures, however, are diagnostic of infertility.”

What are the predictors of fertility? Use chemical state mapping of x-ray microscopy to investigate sperm types from different patients (Holger Fleckenstein, Physics; Dr. Yefim Sheynkin, Dept. Urology) Preparation: compare room temp wet (at right), frozen hydrated, freeze-dried One in-vitro fertilization method: single sperm are selected for injection into egg. What’s the basis for choosing one sperm over another?

Cluster analysis of sperm 

Comparison with mitochondrial DNA spectrum Mitochondrial DNA spectrum: K. Kaznacheyev    Purple region: DNA packed with protamines

N, O edges

Radiation damage on (initially) living cells X-rays are ionizing radiation. The dose per high resolution image is about 100,000 times what is required to kill a person Makes it hard to view living cells!        

Wet, fixed samples: one image is OK Chromosomes are among the most sensitive specimens. V. faba chromosomes fixed in 2% glutaraldehyde. S. Williams et al., J. Microscopy 170, 155 (1993) Repeated imaging of one chromosome shows mass loss, shrinkage

Frozen hydrated specimens Grids with live cells are Taken from culture medium and blotted Plunged into liquid ethane (cooled by liquid nitrogen) Loaded into cryo holder

Radiation damage resistance in cryo                  

Lignocellulosics Radicals are formed by the interaction of peroxide and metal that can damage cellulose Damage results in carboxylic acid groups Visualize the damage physical and chemical testing show      H 2 O 2 

Sample Prep Peroxide bleached and unbleached handsheets Cut ~1cm by 2cm samples Soaked in water Dehydrated in ethanol Used 50/50 mixture of epoxy resin (Epon 812) and propylene oxide 100% epoxy and vacuum Cured in oven between plastic sheets Sectioned to 200nm thick (transverse) and placed on TEM grids

Locating Carboxylic Acids (unbleached) TEM grid hole = ~125 μm

Locating Carboxylic Acids (2) (bleached) TEM grid hole = ~125 μm

Locating Carboxylic Acids (3) (bleached) TEM grid hole = ~125 μm

High Resolution (bleached) Stepper scan (.5 μm) vs. piezo scan (30 nm). High resolution images of damaged regions. Perhaps evidence of hollow center Top = 20 μm Bottom = 8 μm

High Resolution (2) (unbleached) Left = 72 μm Right = ~36 μm

Conclusions Resolution is nm now; pushing towards 10 nm… Tomography lets you look at whole cells up to 10 µm thick (thicker at higher energies?). Radiation damage is less than with electrons, but is still a consideration STXM is a viable tool for the investigation of paper chemistry. Peroxide bleached samples undergo a heterogeneous enrichment of carboxylic acid groups due to radical damage. Results confirm trends previously seen in TOF-SIMS as well as other physical and chemical testing.

Acknowledgements Chris Jacobsen and Janos Kirz (BNL) Doug Mancosky (Hydro Dynamics) Alan Rudie (Forest Products Laboratory) Hiroki Nanko (Georgia Institute of Technology)