Voltage Management of Low voltage (LV) Busbars Plenary session B – Low voltage operation Dan Randles Quality of Supply and Technical Manager/LCNF Tier.

Slides:



Advertisements
Similar presentations
Installation of a Static Var Compensator on to an 11kV network
Advertisements

Load Management System with Intermittent Power on the Grid Ruth Kemsley CEng MIMechE MIEE Econnect Ventures Ltd.
Capacity to Customer (C 2 C) Update ENA 2012 Low Carbon Network Fund Conference 26 October 2012.
CE Electric UK – Potential developments in long-term charging arrangements and IDNO charging methodologies 1 April 9, 2008 Potential developments in long-term.
DISPUTES & INVESTIGATIONS ECONOMICS FINANCIAL ADVISORY MANAGEMENT CONSULTING Early Lessons Learned from DOE-EPRI Framework Experience Melissa Chan MA DPU.
Development and Operation of Active Distribution Networks: Results of CIGRE C6.11 Working Group (Paper 0311) Dr Samuel Jupe (Parsons Brinckerhoff) UK Member.
How Technology will make Renewable Energy Competitive 10/17/2013
 UK Power Networks. All rights reserved Distribution Network Visibility Low Carbon Networks Fund Tier 1 project UK Power Networks & PPA Energy Omer.
Active Fault Level Management Jonathan Berry LCNF Conference 25 th October 2012.
Effects of high penetration levels of photovoltaic generation Observations from field data Amir Toliyat, Alexis Kwasinski and Fabian Uriarte The University.
Low Voltage Network Solutions Plenary session A – Monitoring Networks Dan Randles Quality of Supply and Technical Manager/LCNF Tier 1 Manager.
Smart Urban Low Voltage Network Low Carbon Network Fund Tier 1 Project UK Power Networks & TE Connectivity.
1 Optimising grids Understanding capacity needs to make networks more efficient Mike Kay Networks Strategy and Technical Support Director 23 September.
1 Project Smart Metering Portfolio Foundation & DCC Day 1 Updates April 2013.
1 CLASS webinar 26 March CLASS webinar 26 March 2015 Simon Brooke Electricity North West.
Delivering Energy Innovations at Scale Base Birmingham Roger Hey – Future Networks Manager.
Integrating Multiple Microgrids into an Active Network Management System Presented By:Colin Gault, Smarter Grid Solutions Co-Authors:Joe Schatz, Southern.
1 Innovation Responding to the needs of customers Dan Randles Network Performance & Innovation Manager 3 October 2014.
An Introduction and Overview
Voltage Demonstration Steven Gough Innovation and Low Carbon Network Engineer
SoLa Bristol LCNF Annual Conference - Cardiff Friday 26 th October 2012 Philip Bale Western Power Distribution Innovation and Low Carbon Networks Engineer.
20 10 School of Electrical Engineering &Telecommunications UNSW UNSW 10 Author: Simon Lewis Supervisor: Iain MacGill Industry Supervisor:
1 Fault Assistance Centre David Talbot & Chris Armstrong September 2014.
1 Project Overview Steve Cox Head of Engineering.
1 Kevin Hoban Smart Street Project Manager. 2 Agenda Questions & answers Technical updateIntroduction and overview Trial design.
Technologies for adaptation to climate change: How to make them work?
LEARN. NETWORK. DISCOVER. | #QADexplore Implementing Business Process Management: Steps to Success WCUG – November 18, 2014.
Supervisory Systems.
Group Meeting – Pepco Holdings, Inc. July 17, 2014.
 UK Power Networks. All rights reserved Demonstrating the benefits of energy storage on an 11 kV Distribution Network Matthieu Michel – Technology.
Loss Reduction and CDM at Gubbi Substation Energy Economy & Environmental Consultants Bangalore INDIA.
Fault Level Monitor Ken Lennon LCNF Conference 25 th October 2012.
Smart Grid Forum - Update DCMF Meeting – 7 February 2013 Gareth Evans Head of Profession – Engineering Ofgem.
Allan Miller Director Electric Power Engineering Centre (EPECentre) Introduction to: Renewable Energy and the Smart Grid GREEN Grid 1.
Microgeneration and new end-use technologies in ADDRESS, INCA and SEESGEN-ICT Jussi Ikäheimo (VTT) (& Regine Belhomme, Giovanni Valtorta) IEA DSM 17 workshop.
Reliable Power Reliable Markets Reliable People Performance Targets for the Customer Interconnection Process January, 2008.
Frankfurt (Germany), 6-9 June 2011 ROSA – PT – S3 – 0249 EDP DISTRIBUTION AUTOMATION (r)EVOLUTION.
Prepared By :.  Introduction  Techniques Used  Case Study  Advantages  Application  Conclusion OUTLINE.
1 Flexible Networks for a Low Carbon Future Approaching one year in...so far so good LCNF Conference 26 th October 2012.
1/20 ea technology MicroCHeaP: Month 24 meeting Athens Work Package 4 presentation 21 September 2006 Presented by Yvonne Dickson Partners in power asset.
Geoff Murphy 25 th October 2012 Dynamic Thermal Rating Project.
Frankfurt (Germany), 6-9 June 2011  Authors: Reinhard BREHMERWIEN ENERGIE Stromnetz GmbH - Austria Thomas SCHUSTERWIEN ENERGIE Stromnetz GmbH – Austria.
Frankfurt (Germany), 6-9 June Lars Garpetun – Sweden – Session 6 – 0415 EXPERIENCES FROM OPERATIONS AFTER A FULL- SCALE SMART METERING ROLLOUT REGARDING.
Superconducting Fault Current Limiters
SESSION 3: FROM SETTING PRIORITIES TO PROGRAMMING FOR RESULTS.
The Energy Policy Act of 2005 and Its Revisions to PURPA November 11, 2005 Grace D. Soderberg Assistant General Counsel National Association of Regulatory.
LV Network Templates for a Low Carbon Future Mark Dale & Gavin Shaddick 26 th October 2012.
PV impacts on Suburban Networks Philip Bale Western Power Distribution Innovation and Low Carbon Networks Engineer /
SOLUTION What kind of plan do we need? How will we know if the work is on track to be done? How quickly can we get this done? How long will this work take.
EECE 887 Distribution System Engineering CHAPTER 1 Power Delivery Systems.
Discussion and Preliminary Findings Concerning Voltage Reduction (VR) for Peak Shaving Mark Carpenter Sr. VP T&D Operations December 6, 2012 Presentation.
Frankfurt (Germany), 6-9 June 2011 Irina Melnik – the Netherlands – Session S2 – 0665 Intelligent Distribution Substation improves power quality.
Connecting Low Carbon Generation Clive Goodman Primary System Design Engineer.
Voltage Reduction Task Force Update September 25, 2014 Presentation to ERCOT TAC.
1 CLASS technical Andrew Howard. 2 Back to school for a moment… This fundamental relationship is at the heart of CLASS But how will it change over time.
SAIEE Smart Grid Conference 2016 A Review of Smart Network Solutions for South Africa Dr Charlotte Higgins Kumbuyani Chisoro TNEI Services Limited.
4/16/2010 Regional Planning Group Meeting Long-Term Planning Study of the ERCOT Interconnection Warren Lasher Manager, System Assessment.
Submission on the draft ODV Handbook WEL Networks 14 th April 2004.
1 Electricity North West’s Demand Response demonstration Simon Brooke Low Carbon Projects Manager.
Évora demonstrator site
Smart Grid Paul Bircham Commercial Strategy & Support Director.
Agenda TSOG 8th November
WIND And Solar ENERGY CONVERSION MODEL GUIDELINES Consultation update – September 2016 Presented by Marcelle Gannon.
Demand Control Field Trials
Évora Demonstrator Site
How can metros and municipalities operate to ensure that revenue generated from electricity sales is sustainable? by Dr Minnesh Bipath and Dr Willie de.
EV charging – a grid perspective
Customer Profiles – Analysing the customers of today
g3 Alternative Gas Solutions
Electricity Distribution and Energy Decarbonisation
Presentation transcript:

Voltage Management of Low voltage (LV) Busbars Plenary session B – Low voltage operation Dan Randles Quality of Supply and Technical Manager/LCNF Tier 1 Manager LCNF Conference October 2012

Aims and Objectives 1 Aim is to trial solutions with potential to help voltage management on LV networks and to provide operators with understanding of the potential for alternative methods to cope with the changing nature of demands ability to effectively manage voltages in real-time in a safe and economical manner will be assessed effectiveness of devices to correct power factor will be assessed Issues including phase imbalance and power quality to be assessed where appropriate supported by simulations 30 month project started in April 2011 costing £0.5M

Scope 2 6 sites selected for trials (11kV or 6.6kV) Simulations used to explore numerous scenarios PV clusters or high load areas (or both) LV network monitoring deployed (Incl. PQAs) Dunton Green Edge Green Greenside Howard St Landgate Leicester

Network Monitoring (LVNS) 3 Scope of the deployment 200 x 11kV or 6.6kV to 415V distribution substations Over 1000 LV feeders Sites comprise indoor and outdoor, mostly ground mounted with small number of pole mounted transformers Analogues to be captured RMS voltages and currents Real and reactive power 3ø + neutral Temperature (Ambient, Tx) Real-time (1 minute averages!) Harmonics (not real time) Metrology and Communications (V, I, Q, P, H, Temp) GPRS/3G Private APN

Trials 4 Three techniques were explored through field trials Numerous more will be looked at through simulations Field trials: Substation (ie busbar) voltage regulation via OLTC distribution transformer Harmonic filtering, power factor correction and phase balancing via active filter In-line (ie LV feeder) voltage regulation via power optimizer Field trials commenced in August 2012 and will continue for a period of 12 months Too early in the trial stage to assess results but lots of valuable practical learning already obtained

Voltage Management – Active Harmonic Filters 5 As well as harmonic filtering the AHF provides load balancing and power factor correction Technical details: Active Filter Type PQFS – M10 amp Voltage (V): 420V Frequency (Hz): 50 Total Current (A): 100 Total Power (kVA): 71 IP Rating - IP30 Ambient Temperature -10 o C/+40 o C Dimensions: W585 x D310 x H685 mm ENW have installed the AHF at two locations in Manchester; 1 indoor and 1 outdoor Full harmonic studies have been completed prior to the installation to ascertain background harmonic levels

Voltage Management – Power Perfector (PP+) 6 320kVA rating Voltage optimiser has the capability to adjust target volts AVC available taps (+4%, 0%, - 4%, -8%, -12%) and (+2.7%, 0%, -2.7%, -5.4%, -8.1%) Operating temperature range: - 10 o C/+50 o C Installed by-pass arrangement for trial

Voltage Management – On load Tap changing Distribution Transformer 7 x2 OLTC distribution transformers from Reinhausen of Germany (MR) Technical details for the OLTC: 500kVA rating x1 unit at 11kV and x1 unit at 6.6kV Tapping range - 8% to + 8% in 8 steps of 2% Utilises the MR OLITAP mechanical tap changer Tap changer incorporated within a ‘modified’ UK standard EFACEC Tx Voltage control relay via TAPCON230 with DNP3 Delivered in September 2012 installation scheduled for December Fundamentals providing design and installation support for the AVC equipment AVC

LV Feeder Voltage Control 8

Lessons learnt 9 Approvals, policies and authorisations Customer impact must be minimised particularly noise and interruptions True partnering approach with all project stakeholders Academic support crucial to help make sense of results Site surveys essential to avoid problems during installation Installation quality including anti tamper/vandal Network monitoring key to understanding the outcomes Large volumes of data being generated which needs managing – requires new tools/systems

Network Modelling 10 Validate Extract Analyse

Future solutions 11 The adoption at scale of low carbon technologies will have a significant impact on LV networks Voltage rise/drop Congestion/overload of assets Monitoring is key to firstly understanding the capabilities of LV networks both now and in the future and secondly facilitating smart operation Appears likely that active means of controlling voltages and loadings in LV networks will be implemented in the future Significant change in operation and planning procedures for network operators These techniques are introducing complexity into networks which are inherently simple – this represents a challenge to operators

Thank you 12 Any questions…?