Position Sensing Glove Barbara Tuday Nathan Schreppler Lauren McIlwain Michael Nolan Team 6:

Slides:



Advertisements
Similar presentations
Routed Systems Presented by: Bassam Najar, Design Engineer Butler International Inc.
Advertisements

Mobile light measurement system Measuring light has never been easier.
Gripper Designs By Pragnay Choksi. INTRODUCTION Hands of robots referred to as Grippers No single design is ideal for all applications.
Case-New Holland Steer-by-Wire Detailed Design. Today’s Agenda  Who is CNH?  Background  Project Goal  System Level Concept  Design Components 
Haptic Glove Hardware Graduation Project Prepared by Yaman A. Salman Eman M. Masarweh 2012.
Developing a tool to monitor and help prevent concussions Instrumented Football Helmet Development Team Joseph Jackson (ME) Adam McCauley (ECE) Shawn Kachnowski.
Artificial Limb Project By Casey Dill. Mission Statement This project will improve upon existing plans for an artificial arm with the same capabilities.
Device to Augment Finger Movement in Stroke Patients Team 12 Tom Fleming, Mark Reagan, Tyler Vovos, Brad Rogers.
Group 4 Nick Hatcher, Andrew Taylor, Neil Barnes, Jakob Combs, Chris Cook.
Project Presentation: The AccuDrill Company: AccuTools Inc.
Alan Young, Dr. Weidong Zhou and Dr. Hongjun Yang Department of Electrical Engineering, The University of Texas at Arlington, Arlington, Texas Figure.
Greg Hyde Raymond Zheng Joseph Rojano Katie Bentley Lori Liebman P14414 P3 ARBORLOO WIND RESISTANCE TEST STAND DETAILED DESIGN REVIEW 1.
MSD-I Project Review Modular Motion Tracking Sensors 1.
Lecture 31 Electrical Instrumentation. Lecture 32 Electrical Instrumentation Electrical instrumentation is the process of acquiring data about one or.
Lecture161 Instrumentation Prof. Phillips March 14, 2003.
ME 224 Experimental Engineering: Professor Espinosa 2005 TEAM : Jamie Charles Carlo Niko Javier.
Guitar Neck Duplicator By Eric Hall. Background  Difficult to Replicate  Time Consuming  Generally done by hand.
Team Hubble Jr. Final Presentation Rachel Small, Holly Zaepfel, Ryan Del Gizzi, Kyle Norman, and Evan Levy December 5, 2006.
Gage Blocks.
Ergonomic Housing improvements to Personal Smoke Monitoring Device Team: Evan Wozniak Sarah Kostuk Christina Smith Aaron Prahst Multidisciplinary Senior.
Capstone Design Team. CHI-A 정준영 전우준 김건식 김병찬 한일환
GESAC, Inc Development of Abdomen Compression Measurement Sensors T. Shams, N. Rangarajan, J. Rowe, H. Conner GESAC, Inc.
Information Technology Lecture No 3 By: Khurram Shahid.
Gage Blocks Unit 12.
 Flex sensor are the sensor that change in resistance depending on the amount of bend on the sensor.  They convert the change in bend to electrical resistance,
Power Control System for a Concrete Durability Test Cabinet – Phase 2 Jacob Jameson Madhav Kothapalli Thomas Persinger Andrew Versluys.
WIRELESS MICROMACHINED CERAMIC PRESSURE SENSORS
University of Pennsylvania Moore School of Electrical Engineering ABSTRACT: The ability to communicate is essential for surviving in today’s world, but.
I NTRO TO PO10029: C ONTROL E NHANCEMENTS FOR A IR M USCLE B IOMIMETIC H AND Dr. Kathleen Lamkin-Kennard Sept. 14, 2009.
Actuator 2 – Provides rotation about the roll direction. Actuator 1 – Provides rotation about the pitch direction Figure 2: The Linear Actuator model Abstract.
TESTING LEVELS Unit Testing Integration Testing System Testing Acceptance Testing.
Testing Considerations Because of potential life threatening consequences resulting from device malfunction, it is critical that the device be fully tested.
Capstone Design Team. CHI-A 정준영 전우준 김건식 김병찬 한일환
Abstract Inexpensive ultrasonic tape measures are available that can only measure perpendicular distances to fairly large, flat surfaces. Complex environments.
E-NABLE Hand Test Rig P16061 David Schwartz, Tia Parks, Shannon Barry, Samantha Mason, Charles Rumfola.
Capstone Design Team. CHI-A 정준영 전우준 김건식 김병찬 한일환
Capstone Design Team. CHI-A 정준영 전우준 김건식 김병찬 한일환
E-NABLE Hand Test Rig P16061 David Schwartz, Tia Parks, Shannon Barry, Samantha Mason, Charles Rumfola.
BME 353 – BIOMEDICAL MEASUREMENTS AND INSTRUMENTATION MEASUREMENT PRINCIPLES.
Lecture 2. An Overview of Engineering Design JANUARY 2016 GE105 Introduction to Engineering Design College of Engineering King Saud University.
SYSTEM LEVEL DESIGN REVIEW P16318 Gaseous Mass Flow Rate Controller Luke McKean, Lianna Dicke, Selden Porter, Schuyler Witschi ?
Mid Semester Presentation Glove Mouse. Jacob BassettChelsea MosserRobert BlackBryan Lee Electrical Engineer HID Protocol Enclosure Electrical Engineer.
Continuous Passive Motion Hand Rehabilitation Matthew Byrne 2, Aaron Hadley 1, Jennifer Hornberger 1, Jonathan Webb 2 Advisors: Bert Lariscy †, Crystal.
Novel Smart Sensor Glove for Arthritis Rehabilitation
1 Chapter 01 Measurement And Error. 2 Summary Instrument – a device or mechanism used to determine the present value of a quantity Measurement – a process.
Device for acute rehabilitation of the paretic arm after stroke Team: Carly Brown, Sasha Cai Lesher-Perez, Lee Linstroth and Nathan Kleinhans Advisor:
Electric Air Ukulele Ivan Setiawan (setiawa2) Satyo Iswara (iswara2) ECE 445 Senior Design Spring 2012 Team #32 TA: Jane Tu.
Gas Pressure Meter (Engineering World Health) Advisor: Prof. Ken Gentry Client: Prof. John Webster, Engineering World Health Engineering World Health Team.
Final Presentation April 19, 2010 Contactless Angular Position Sensor Team: Eugene Sandberg, Christine Bratton, Matt Landry, Aram Lee, Jeremy Lewis Faculty.
National Highway Institute 5-1 REV-2, JAN 2006 EQUIPMENT FACTORS AFFECTING INERTIAL PROFILER MEASUREMENTS BLOCK 5.
Continuous Passive Motion Hand Rehabilitation. Design Team Project Sponsors: Bert Lariscy, Vanderbilt University EE graduate Crystal Bates, Occupational.
Continuous Passive Motion Hand Rehabilitation
Predetermined Time Systems
Device for Acute Rehabilitation of the paretic hand after stroke
Terms and Definitions • Abduction – away from the center (midline) of the body • Active-assistive ROM – The nurse assistant assists the resident in performing.
MANUAL RESISTANCE FOR UPPER LIMB
Instrumented Walker Skyler Bullington Tommy Frankenberger Larson Stacy
Nano-fluidic Characterization
Predetermined Time Systems
Research in hairdressers Tasks, posture and MSDs
Team We Ate 9 No Glove, No Love.
Modular Motion Tracking Device
Endotracheal Tube Cuff Valve
Continuous Passive Motion Hand Rehabilitation
P17082 Integrated System Build & Test Review
Modular Motion Tracking Device
Care and Prevention of Athletic Injuries
Solar Generation System
Development of Handheld Automotive Tool
Presentation transcript:

Position Sensing Glove Barbara Tuday Nathan Schreppler Lauren McIlwain Michael Nolan Team 6:

For the last 56 years ILC Dover Inc. has been a leader in engineered softgoods products in industry as well as government. They are commonly known for NASA’s spacesuits.

During a hand therapy session, physical therapists must manually measure the angle of each joint in a patient’s hand and wrist. Background

Problem Statement Our goal is to design, develop, produce, and test a prototypic, low-cost, and functional glove that will sense key finger, thumb, and wrist positions using compliant advanced technologies.

Key Joint Positions What joints do we actually need to measure? Thumb Fingers Wrist

Key Motions What motions do we need to measure? Flexion and Extension

Key Motions cont. Abduction & Adduction Pronation & Supination (Wrist Rotation) Total of 41 angles to be measured

Problem Constraints Safety United States Patents FDA 510 K Regulations

Customers ILC Dover Inc.  Engineers  Manufacturers Physical Therapists Patients Hospitals Retailers

Product Breakdown Overall Glove SensorsWiring Glove Material DAQ

Product Wants - Overall

Product Wants - Sensors

Sensor Metrics and Target Values MetricTarget Value Accuracy+/- 2.5 degrees Cost$ Cycles to Failure50,000 Resistance35,000 ohms Radius of Curvature0.1 inches No. of Parts Needed21 Ease of Flexibility (0-5)4 Frequency50 records per second Less Threatening (0-5)4

Product Wants - Wire

Wire Metrics and Target Values MetricTarget Values No. of Flexures before Failure 50,000 Radius of Curvature0.1 in Ease of Flexibility (0-5)5 Diameter0.025 in No. of Washes500

Concept Sensors  Peratech (1 st choice)  Spectra Symbol (used in prototype) Wire  Calmont (1 st choice)  Silver wire (used in prototype) DAQ  LabView Material  Knit, lightweight comfort glove

Modeling Gloves were modeled using acceptable substitutes for our materials  Attachment Methods  Wiring  Various Securing Devices

Modeling – Attachment Methods

Modeling – Wiring

Modeling – Securing Devices

LabView Program Created for individual sensor

LabView Program cont. Convert From Voltage to Degrees Analog In Show Array on A Graph Display Max. & Min. Degrees Obtained

Wiring Sensors

Testing Attachment Method Glue Sensors Directly to Glove

Testing Attachment Method cont. Sensors Held to Glove by Patches

Initial Testing To initially test the sensors, a spring was used as a finger model Cloth was placed around the spring to represent the glove The sensor was attached and tested

Labview Expansion Labview was expanded in order to capture the results of several sensors simultaneously Able to connect five sensors at a time

Testing Position Due to the length of our sensors, a slanted configuration was favorable for close-fitting locations Sensors on knuckles could remain aligned with the joint

Calibrating Sensors Output data was collected for several angles on specific joints Data was not repeatable between tests and oftentimes varied greatly We had to try to understand where the error was coming from

Sensor Error We analyzed the situation and came up with two areas of possible error:  Instability of sensor connections  Absence of a stiff backing to provide support for the sensors

General Sensor Criteria After experiencing difficulty with the sensors we realized that these problems could arise with future sensors We decided to create tests that could analyze the behavior of these and future sensors

Behavior Testing of Individual Sensor Tests were performed, keeping the electrical connection tightly secured, for the following three types of backing on the sensors:  No Backing  Thick Backing (0.01”) – provided by Spectra Symbol  Medium Backing (0.008”) – 3 layers of Scotch Packaging tape

Behavior Testing of Individual Sensor Bend Radius Test

Behavior Testing of Individual Sensor Tension Test

Behavior Testing of Individual Sensor Twist Test

Behavior Testing of Individual Sensor Pressure Test

Stabilizing Connection Since all the tests with the stabilized connections came out with satisfactory results, we felt that the previous problems were at the sensor connection, so we added a connection stiffener The backing on the sensor could help the stability

Testing New Sensors The new backing was then tested for repeatability with and without the connection stiffener This testing showed the backing offers some extra support which improves the repeatability

Calibrating New Sensors The new sensors were then calibrated Blocks were cut to the angles desired so that the calibration procedure could be easily repeated

Results The results from the final calibration came out better then the initial calibration These results, however, were still not accurate enough to meet the needs of the desired product

Cost of Materials

Future Work ILC should use the testing methods devised in this project first test the new Peratech sensors The sensors should then be tested on the actual glove If problems arise, the sensor connection should be addressed as done in this project

Thank You!! Questions?

Schedule

Total Cost

Final Prototype

Initial Calibration

Final Calibration

Final Calibration Data

Sensors Results