Engineering Controls and Laboratory Design Session 4 Laboratory Safety Training.

Slides:



Advertisements
Similar presentations
Facilities Management and Design Chapter 4 Safety and Security systems.
Advertisements

PowerPoint ® Presentation Chapter 14 Homeland Security Homeland Security Building Layout Specific CBR Attack Prevention Recommendations Securing Outdoor-
Architectural Services Department HKSAR Laboratory Design for Secondary Schools.
Containment Equipment and Facilities. Biocontainment The principle of holding or being capable of holding or including within a fixed limit or area The.
Aishah Hazlina Md.Dean Jurutera Mekanikal
Airflow and BSC Biosafety and Biosecurity Awareness Training
HVAC 101 The Basics of Heating, Ventilation and Air Conditioning
The Role of Controls for Indoor Air Quality Kent W. Peterson, PE, Fellow ASHRAE P2S Engineering, Inc. Mid Columbia ASHRAE Chapter.
Innovative Air Distribution for Healthcare Facilities.
Introduction Enthalpy Wheel
Approved by Chemistry Department Faculty January 13, 2005 Upon the recommendation of C. A. S. H. and Department Safety Committee UNC Chemistry Department.
SETUP Chapter 6 Lead Abatement for Workers Course.
Lab Banding  More than assigning # of air changes/hour to lab  Lab operations risk assessment with hands on approach to ensure safe operation while reducing.
Laboratory Ventilation. 2 Types of Laboratory Hoods  Constant Volume  Conventional  By-Pass  Auxiliary-Air  Reduced Air Volume  Variable Volume.
Lab Energy Management Big Ten Mechanical & Energy Conference October
Codes and Standards to be followed in the design and construction of the Green Energy facility National Fire Protection Assoc (NFPA); American Gas Association.
Welding, Cutting, & Burning. GENERAL HAZARDS General hazards of welding include: –Impact –Penetration –Harmful dust –Smoke –Fumes –Heat –Light radiation.
The Life Safety Surveyor Facility Tour
Providing services that help make The University of Memphis a safe and healthful place to learn and work Environmental Health and Safety.
Laboratory Safety-Fume Hoods 29 CFR Laboratory Safety Standard.
Siemens Building Technologies, Inc. ED&G 100 Design Project Fume Hood Face Velocity Control Spring 2004.
Zettl Group Safety Talk ~Fume Hoods~ 09/28/06 Takashi Ikuno.
The Campaign for McMaster University Information Guide to Fume Hoods Facility Services (ext )
Safety Workshop June 16,  Safety: responsibility of the school board, district administration, teachers, parents, and students.
1 FUME HOOD SAFETY Environmental Energy Technologies Division Safety Topic July 12, 2012.
Sandia is a multi-program laboratory operated by Sandia Corporation, a Lockheed Martin Company, for the United States Department of Energy’s National Nuclear.
Lab Inspections State Fire Marshal’s Office. Applicable Codes 1999 BOCA Business Occupancy 1999 BOCA Fire Prevention Code 2000 NFPA 101, Life Safety Code.
Texas Department of Insurance State Fire Marshall’s Office Sixth Report on State University Fire Safety January 2002.
Fire Marshal’s Office Department of Environmental Safety LABORATORY FIRE SAFETY LABORATORY. FIRE SAFETY.
1 CHEMICAL SAFETY LEVELS FOR SCHOOL LABORATORIES A SYSTEM FOR IDENTIFYING RISKS UPON ENTERING A LAB.
Chemical Fume Hood  A type of local ventilation device that is designed to limit the user's exposure to hazardous or noxious fumes, vapors or dusts.
 MIOSHA Standard for Hazardous Work in Laboratories  Methods and Observations Used to Detect the Presence or Release of a Hazardous Chemical  Permissible.
 An orientation to GVSU’s lab facilities.  A description of GVSU’s health and safety program.  Procedures for gaining access to your workshop supplies.
Buildings and Structures 2 Natural and Mechanical Ventilation.
Spray Finishing Operations/Spray Booth March 9, 2009.
Unit 6.2. Mechanical and mixed mode ventilation TB Infection Control Training for Managers at National and Subnational Level.
HOT WORK PROCEDURES Welding and Hot Work, such as brazing or grinding present a significant opportunity for fire and injury. CCR Title 8 Sub Chapter 7,
Phone: Fax:
Fire Protection John Giefer. Statistics In the Drilling Industry In the Drilling Industry 25% of all inspections found violations of (21 inspections.
AIR CONDITIONING SYSTEMS 1. All Air Systems An all-Air System is defined as a system providing complete sensible and latent cooling capacity in the cold.
EGRESS AND FIRE PROTECTION
The Physical Environment Tracers How Should I Prepare for the Physical Environment Tracers? Healthcare Engineering Consultants  Will limit.
Building Codes and Interior Design
© 2008 Data Power Services, LLC By: Tom Taranto 2010 Energy Expo Hosted by National Grid NYSERDA Reducing Compressed Air Energy Cost Using a Systems Approach.
Fire Safety By Alicia Civile and Alexandra Fernandez.
CHAPTER 12 Copyright © 2007 Thomson Delmar Learning 12.1 Protective Systems.
MINNESOTA CHAPTER AUTOMATIC FIRE ALARM ASSOCIATION Requirements of the 2003 Minnesota State Fire Code relating to Group R Occupancies September 14, 2006.
Sandia is a multi-program laboratory operated by Sandia Corporation, a Lockheed Martin Company, for the United States Department of Energy’s National Nuclear.
Chapter 5 ID 234 Building Codes Fire Resistant Materials and Assemblies.
ID 234 Building Codes Life Safety Diagram:Review.
Spray Booths Follow safe operating instructions. Spray-finishing operations  Organic materials  Inorganic materials  Dispersed form  Deposited to.
Lab design Assignment 3 Unit 2.
Chapter 6 ID 234 Building Codes Fire Suppression.
KEK, 04/28/061 Safety Plan Assumptions Break out of fire in the Beam Tunnel is negligible Cables in the Service Tunnel is main fire load They are combustible.
Exercise #2 (part 2) Based on what you read in Chapter 4, determine if the corridors and exit doors meet the requirements for egress width, according to.
Flammable Liquids Directorate of Training and Education
Implementing Wind Responsive VAV Exhaust Systems at NREL's ESIF Building: A Four-Year Follow-Up Otto VanGeet, PE, NREL Brad Cochran, CPP I2SL -August 29,
3 MANAJEMEN FASILITAS DAN KESELAMATAN ( SAFETY )
DoD Fuels Laboratory Standards UFC
What Library Staff Should Know About Fire Safety
29 CFR NFPA Life Safety Code
تهیه و تنظیم: مهندس همت جو
أجهزة الشفط في المختبرات الكيميائية: كيف تعمل ومتى لا تعمل
Fume Hood – Proper Handling of Chemicals / Proper Functioning
INNOVATION lab MEP MECHANICAL/ELECTRICAL/PLUMBING :
Laboratory Ventilation
Building standards Mr. Da Silva.
Shut the sash! April 2017 Safety Focus.
Presentation transcript:

Engineering Controls and Laboratory Design Session 4 Laboratory Safety Training

2 Types of Laboratories Academic vs. Industrial Research vs. Instructional Similar functions housed togeather vs. building for entire departments Future flexibility, diversity.

3 Engineering and Architectural Principals Laboratory buildings present difficult challenges –Very little assignable space (65%) –Energy hog, conditioned air, elec. needs, services, fire protection life safety issues, Architects must balance beauty with safety. Engineers must balance conserving energy with safety. Both must balance users needs and cost with safety.

4 Organizations Regulating Laboratory Design Southern Building Code (SBC) Building Officials and Code Administrators (BOCA) National Fire Protection Assoc (NFPA) Standard Fire Protection Codes

5 Basic life safety design components Labs should be designed to provide at least one, usually two clear means of egress. The building should have at least two clearly marked means of egress at opposite ends of the building for occupancies up to 500 persons (3 for ). Doors must swing in the direction of the exit travel

6 Basic life safety design components Travel distance must not exceed 200 ft (with no fire suppression, 250 with). 1 hour fire rated corridors, stairwells, Storage not permitted in these areas. Self closures on doors. Areas of refuge. ADA compliance issues ramps.

7 Basic life safety design components Emergency power for signs, lights, equipment. Chemical Storage room requirements –Class I Division 2 requirements (normally contained flammable liquids).

8 Fire Protection Systems –Sprinkler systems –Co2 systems –Inergen (N2 Ar, Co2) –Dry Chemical systems

9 Fire Detection Systems Automatic and Manual stations are required. Networked systems. Visual and audible. Fire extinguishers.

10 Other Issues/Equipment Backflow prevention on the clean water (potable) side. Contamination can occur during pressure differentials of a piece of tubing in a sink under water flush several toilets and the pressure drops on the dirty side causing a back flow of water.

11 Chemical resistant casework, typically epoxy coating. Flammable storage cabinets. Acid storage cabinets. Glove boxes. Local exhaust ventilation for equipment, processes. Other Issues/Equipment

12 Other Issues/Equipment Biological safety cabinets –Class I-III (glove boxes) partial to 100% exhaust. Emergency eyewashes and safety showers. –Must tempered and require no more than 10 sec to reach.

13 Other Issues/Equipment Compressed gas storage. Vacuum, air, compressor issues. Waste issues.

14 Ventilation All labs using chemicals require 100% out side air. The number of air changes per hour (ACH) are recommended by various organizations. Regulated by organizations like ANSI (American National Standards Institute), ASHRAE (American Society Heating Refrigeration, Air Conditioning Engineers), NFPA (National Fire Protection Association), OSHA

15 Ventilation Cont. Because of the requirement for 100% outside air and the number of exhaust point and exhaust volume mechanical systems are one of the largest costs. Variable air volume systems were designed to minimize these cost. Constant air volume hood systems with set backs

16 Types of Hoods Constant Air VAV Auxiliary air Recirculated Air (bad bad bad)

17 Constant Air Volume Hoods Known also as bypass hoods Face velocity changes as sash is opened but total exhaust remains constant. Advantages: –Simpler to maintain. –Can be manifolded or have individual fans. –With off time set backs can be more efficient

18 Constant Air Volume Hoods Disadvantages –Can be inefficient in smaller labs with several hoods.

19 Variable Air Volume Hoods Maintain a constant face velocity independent of the size of the sash opening Tracks room pressurization (to keep room negative) to fume hood exhaust. Manifolded system, redundant fans. Reduces possibility of reentry into building.

20 Variable Air Volume Hoods Cont. Potential cost savings by allowing a reduction of supply air when sash is shut. –Hoods exhaust cfm –8-10 ach, at $6-8/cfm of conditioned air can get very expensive.

21 Variable Air Volume Hoods Disadvantages Initial cost high. Many control points to track, potential for malfunction. Difficulty in maintaining sophisticated controls. When the system goes down the entire building is not exhausted.

22 Auxiliary Air Hoods Advantages –Unconditioned air is deposited into the hood at the face. Saves on conditioned make-up air. Disadvantages –Researcher is either cold or hot while standing at the hood. –Requires a separate supply system. –Difficult to balance, maintain containment.

23 Recirculated Air Fume Hoods Should never be used, recirculates fumes after passing air through a filter.

24

25

26

27

28 Single Hood - Single Fan CAV System

29 Multiple Hood - Single Fan CAV System

30 Multiple Hood - Multiple Fan VAV System

31 Minimum hood standards All hoods must be tested to the ANSI//AIHA Z9.5 standard. Requires a manufacturers test, as installed test and as used test. Minimum face velocity must be be fpm, optimum 100 fpm at 18” sash opening. Flow monitors should be installed on all new hoods with a visual or audible alarm

32 Minimum hood standards ANSI/ASHRAE 110, smoke visualization and tracer gas tests are recommended to identify hood performance and containment.

33 Hood installation Fume hoods should be placed in the back corner of the room away from turbulence and diffusers. Not near the means of exit. Away from windows.

34

35

36

37

38

39

40

41

42

43