Recent news about SiPM based applications R&D in DESY Nicola D’Ascenzo University of Hamburg - DESY.

Slides:



Advertisements
Similar presentations
MPPC Nicola D’Ascenzo, Erika Garutti, Martin Göttlich
Advertisements

Scintillator Tile Hadronic Calorimeter Prototype (analog or semidigital) M.Danilov ITEP(Moscow) CALICE Collaboration LCWS04, Paris.
10 March 2004Erika Garutti - KEK, Japan1 Development of an Hadronic Tile Calorimeter for TESLA New calorimeter concept for linear collider detector The.
PET Design: Simulation Studies using GEANT4 and GATE - Status Report - Martin Göttlich DESY.
Quartz Plate Calorimeter Prototype Ugur Akgun The University of Iowa APS April 2006 Meeting Dallas, Texas.
Multi Pixel Photon Counters (MPPC) and Scintillating Fibers (Sci-Fi)
The Multi-Pixel Photon Counter for the GLD Calorimeter Readout Jul Satoru Uozumi University of Tsukuba, Japan 1.Introduction 2.Recent.
Performance of MPPC using laser system Photon sensor KEK Niigata university, ILC calorimeter group Sayaka IBA, Hiroaki ONO, Paul.
Fiberless Coupled Tiles for a High Granularity Scintillator-SiPM Calorimeter Rick Salcido Northern Illinois University November 14, 2009 Prairie Section.
A preliminary analysis of the CALICE test beam data Dhiman Chakraborty, NIU for the CALICE Collaboration LCWS07, Hamburg, Germany May 29 - June 3, 2007.
Application of Neural Networks for Energy Reconstruction J. Damgov and L. Litov University of Sofia.
Michele Faucci Giannelli TILC09, Tsukuba, 18 April 2009 SiW Electromagnetic Calorimeter Testbeam results.
Photon detection Visible or near-visible wavelengths
Selection of Silicon Photomultipliers for ILC Analogue Hadron Calorimeter Prototype Lay-out * ILC Hadron Calorimeter prototype with SiPM readout * Selection.
Calorimetry: a new design 2004/Sep/15 K. Kawagoe / Kobe-U.
CALICE Meeting DESY ITEP&MEPhI status report on tile production and R&D activities Michael Danilov ITEP.
Beam test of scintillator strips Miho NISHIYAMA Shinshu University ・ scintillator strip calorimeter ・ Kuraray scintillator strips and KNU extruded ・ the.
R&D on W-SciFi Calorimeters for EIC at Brookhaven E.Kistenev, S.Stoll, A.Sukhanov, C.Woody PHENIX Group E.Aschenauer and S.Fazio Spin and EIC Group Physics.
The MPPC Study for the GLD Calorimeter Readout Introduction Measurement of basic characteristics –Gain, Noise Rate, Cross-talk Measurement of uniformity.
Scintillation hodoscope with SiPM readout for the CLAS detector S. Stepanyan (JLAB) IEEE conference, Dresden, October 21, 2008.
The Scintillator ECAL Beam Test at FNAL Adil Khan International Linear Collider Workshop 2010 LCWS10 & ILC10, Beijing, China CALICE Scintillator ECAL group.
The Scintillator ECAL Beam Test at FNAL K. Kotera, Shinshu-u, 1st October 2009 CALICE Scintillator ECAL group; Kobe University, Kyungpook University, the.
Hadron Calorimeter Felix Sefkow EUDET Annual Meeting October 20, 2006.
The Tungsten-Scintillating Fiber Accordion Electromagnetic Calorimeter for the sPHENIX Detector Craig Woody, for the PHENIX Collaboration Physics Department,
Light Calibration System (LCS) Temperature & Voltage Dependence Option 2: Optical system Option 2: LED driver Calibration of the Hadronic Calorimeter Prototype.
Scintillator tile-SiPM system development for CALICE Engineering AHCAL Prototype Michael Danilov, ITEP & CALICE LCWS10 Beijing March 2010 Outline New scintillator.
Study of the MPPC performance - R&D status for the GLD calorimeter readout – Nov 6-10.
Study of the Multi-Pixel Photon Counter for ILC calorimeter Satoru Uozumi (Kobe University) Atami Introduction of ILC and MPPC The MPPC performance.
Study of the MPPC for the GLD Calorimeter readout Satoru Uozumi (Shinshu University) for the GLD Calorimeter Group May 29 – Jun 4 DESY Introduction.
Scintillator ECAL for ILC for Calorimeter Review DESY May2007 Tohru Takeshita (CALICE-Shinshu) Idea implementation current status future mile stones.
SiD R&D tasks for the LOI - Subsystem R&D tasks - Summary of SiD R&D - Prioritization of R&D tasks -> Document for DoE/NSF ~Feb 2009 (Mainly based on Marty’s.
Supervisor: Samir Arfaoui By: Fatma Helal Sawy
The Case for the Dual Readout Calorimetry for SiD Adam Para, December 4, 2007.
LHC The Large Hadron Collider (LHC) is an accelerator with 27 km circumference. Being built on the France- Switzerland border west of Geneva. It will start.
Study of the MPPC for the GLD Calorimeter Readout Satoru Uozumi (Shinshu University) for the GLD Calorimeter Group (KNU, Kobe, Niigata, Shinshu, ICEPP.
Timing Studies of Hamamatsu MPPCs and MEPhI SiPM Samples Bob Wagner, Gary Drake, Patrick DeLurgio Argonne National Laboratory Qingguo Xie Department of.
V. Korbel, DESY1 Progress Report on the TESLA Tile HCAL Option To be filled soon.
SiPM for CBM Michael Danilov ITEP(Moscow) Muon Detector and/or Preshower CBM Meeting ITEP
5-9 June 2006Erika Garutti - CALOR CALICE scintillator HCAL commissioning experience and test beam program Erika Garutti On behalf of the CALICE.
06 FEB th ACFA Development of fine strip scintillator with extrusion technique SungHyun Chang, DongHee Kim, Jun Suhk Suh, Youngdo Oh, Daejung Kong,
P. Lecoq CERN February SiPM Workshop, CERN, February, 2011 New Approaches in Scintillation Detectors in the Context of HEP Calorimetry and.
Calice Meeting Argonne Muon identification with the hadron calorimeter Nicola D’Ascenzo.
Edouard Kistenev for the PHENIX Collaboration Calorimetry based upgrade to PHENIX at RHIC CALOR 2012 Santa Fe, NM, June 4-8, 2012.
Performance of Scintillator-Strip Electromagnetic Calorimeter for the ILC experiment Satoru Uozumi (Kobe University) for the CALICE collaboration Mar 12.
Jet Energy Measurement at ILC Separation of jet particles in the calorimeter is required for the PFA  Fine granular calorimeter is necessary. Particle.
The KNU-WCU Scintillator Laboratory The WCU Collider Physics Research Group in Kyungpook National University Jets from more massive particles decay 1.Introduction.
Hadron Calorimeter Felix Sefkow EUDET Extended Steering Meeting September 11, 2006.
The Multi-Pixel Photon Counter for the GLD Calorimeter Readout Jul Satoru Uozumi University of Tsukuba, Japan for the GLD Calorimeter.
Study and Development of the Multi-Pixel Photon Counter for the GLD Calorimeter Satoru Uozumi (Shinshu, Japan) on behalf of the GLD Calorimeter Group Oct-9.
The KNU-WCU Scintillator Laboratory The WCU Collider Physics Research Group in Kyungpook National University Jets from more massive particles decay 1.Introduction.
M.Teshima (MPP, U-Tokyo) M.Pimenta (LIP) T.Schweizer (MPP)
Silicon Photomultiplier Development at GRAPES-3 K.C.Ravindran T.I.F.R, OOTY WAPP 2010 Worshop On behalf of GRAPES-3 Collaboration.
Tokubetsu-shishin kickoff meeting, Sep-13 th 2011 Satoru Uozumi Korean Activities on Calorimetry in ILC History of Japan-Korea collaboration.
Study of the MPPC for the GLD Calorimeter Readout Satoru Uozumi (Shinshu University) for the GLD Calorimeter Group Kobe Introduction Performance.
SuperB workshop SLAC, October 6, Outline Present Design Some thoughts about tile production Updated cost estimate Light yield studies of 3 mm thick.
Prospect of SiPM application to TOF in PANDA
Frontier Scintillation Detectors: Inorganic Scintillating Fibers
Scintillation Detectors in High Energy Physics
CEPC 数字强子量能器读出电子学预研进展
EUDET JRA3, Activity Obninsk State University
for a scintillator based MTT
Backward Calorimetry For SuperB
State-of-the-art in Hadronic Calorimetry for the Lepton Collider
Vishnu V. Zutshi For the NICADD team.
Comments on Dual Readout Calorimeter
ITEP&MEPhI status report on tile production and R&D activities
On behalf of CEPC calorimeter working group
Project Presentations August 5th, 2004
Reports for highly granular hadron calorimeter using software compensation techniques Bing Liu SJTU February 25, 2019.
The MPPC Study for the GLD Calorimeter Readout
Presentation transcript:

Recent news about SiPM based applications R&D in DESY Nicola D’Ascenzo University of Hamburg - DESY

13 Giugno 2007I Workshop Italiano su nuovi photodetectors 2 Calorimetry at International Linear Collider The ILC physics requires a calorimeter with: 1.High granularity (Good jet energy resolution) 2.Ermeticity and good missing energy resolution 3.Compactness (The detector has to stay inside the magnetic coil)

13 Giugno 2007I Workshop Italiano su nuovi photodetectors 3 The scintillator tile hadron calorimeter Sampling calorimeter : absorber stainless steel, active medium plastic organic scintillator. Along the magnetic field direction it extends in -220 cm < z <220 cm It covers the detector along the radius in the region 180 cm< r < 290 cm The test beam prototype: 1 m 3. Test beam prototype : 38 layers, 216 channel per layer.

13 Giugno 2007I Workshop Italiano su nuovi photodetectors 4 SiPM: a good photodetector for hadron calorimetry The good SiPM for this application: 1.Low noise above the suggested cut on the mip spectrum (Controlled dark rate and cross talk) 2.Light Yield not exceeding the saturation behaviour of the device. 3.Stable and controlled production

13 Giugno 2007I Workshop Italiano su nuovi photodetectors 5 The scintillator direct readout The direct readout is easier to extend to a large scale production. The solution which respects the required bounds on the parameters: 1.Blue Sensitive? 2.Green sensitive and large?

13 Giugno 2007I Workshop Italiano su nuovi photodetectors 6 The MPPC by Hamamatsu Blue sensitive Silicon PhotoMultiplier, Suitable for the direct coupling

13 Giugno 2007I Workshop Italiano su nuovi photodetectors 7 Direct readout with MPPC Readout of a plastic scintillator tile directly and comparison with the mediated green fiber Tile wrapped with a 3M reflector. In case of the direct readout, only a window of 1mm x 1mm is open in front of the MPPC Source: Ru106 Integration gate 80 ns External trigger (Photomultiplier tube) Reproducibility of the measurement +- 3% systematic (coupling, positioning etc...)

13 Giugno 2007I Workshop Italiano su nuovi photodetectors 8 Direct readout with MPPC : Most Probable Value of the mip response spectrum 400 px 1600 px The green dots correspond to the traditional wavelength shifter fiber readout. The performances of the MEPHI SiPMs used are totally reproduced. THe blue dots correspond to the direct readout: a good light yield is obtained

13 Giugno 2007I Workshop Italiano su nuovi photodetectors 9 The direct readout with MPPC: mip collection efficiency Cut at 3 KHz 400 px 1600 px

13 Giugno 2007I Workshop Italiano su nuovi photodetectors 10 Direct Readout with MPPC: application to electromagnetic calorimetry GLD-CAL group, Kobe University This is the first attempt of using MPPC in the direct readout configuration in the calorimeter design. The study of the impact of this technology in the physics reconstruction is still in progress.

13 Giugno 2007I Workshop Italiano su nuovi photodetectors 11 The direct readout: discussion The direct readout looks promising for the simplification of the design of the calorimeter and the extension of the concept to a large scale. Still some conceptual problems: –Uniformity of the light response according to the impact of the particle in the scintillator Montecarlo studies and experiments will test this soon What is the effect on the performance of the calorimeter? –What is the best position for the coupling? The blue sensitive MPPC opened good perspectives to the design of calorimeters: ready to test new photodetectors.

13 Giugno 2007I Workshop Italiano su nuovi photodetectors 12 Application of MPPC in PET: motivations and goals The calorimeter si just a big PET machine: –The hadron calorimeter has milions of channels –The hadron calorimeter has a very high granularity: imaging detector! It is only needed to: –Change scintillator (from organic to inorganic) –Change granularity (from 3x3 cm 2 to ~1x1 mm 2 ) The technology and the needs of the photodetector are the same ! Energy resolution and timing measurements This study is just at the beginning!

13 Giugno 2007I Workshop Italiano su nuovi photodetectors 13 Application of MPPC in PET: setup 2 LSO Crystals of 1mm x 1mm (3mm x3mm) Read out by 1x1 mm (3x3 mm) Hamamatu MPPC No amplification needed!!! QDC &

13 Giugno 2007I Workshop Italiano su nuovi photodetectors 14 Application of MPPC in PET: energy resolution 3mmx3mm LSO crystal Coupled with a 3mmx3mm MPPC 1mmx1mm LSO crystal Coupled with a 1mmx1mm MPPC Resolution =14 % Resoultion =20 % PRELIMINARY

13 Giugno 2007I Workshop Italiano su nuovi photodetectors 15 Application of MPPC in PET: timing resolution Cut at 7 photoelectrons PRELIMINARY 4 GHz Digital oscilloscope used to calculate the time difference (50 ps precision) Still the system needs to be improved with a lower discrimination.

13 Giugno 2007I Workshop Italiano su nuovi photodetectors 16 Application of MPPC in PET: discussion The application of MPPC in Positron Emission Tomography looks promising: the blue sensitivity of the photodetectors is excellent. In DESY we will test different combinations of crystals and photodetectors: YAP, LYSO... With SenSL, new Hamamatsu.... The enrgy resolution measurement will be continuosly improved in reproducibility and stability of the system Timing measurement (important also for time of flight) is currently beeing improved.

13 Giugno 2007I Workshop Italiano su nuovi photodetectors 17 After the serious conclusions... The spin off of the technlogical developement around the new high energy Phyics experiments is very important... We are dedicating lots of efforts in order to keep open and fruictful the interplay between high energy physics and medical physics. If we will not find the Higgs Boson, at least, we can tell we were useful for something...