Menu Copyright © 2005 by The SEA Group negative pressure respirators.

Slides:



Advertisements
Similar presentations
Standard 29 CFR Part Respiratory Protection.
Advertisements

Personal Protective Equipment (PPE)
AGRIMAR (UK) PLC AGRIMAR (UK) PLC CANAL COURT, 152 HIGH STREET BRENTFORD, MIDDLESEX TW8 8JA UNITED KINGDOM TEL: (0) FAX: (0)20.
Respiratory Protection Training 29 CFR Respiratory Protection- Employer Roles Employers are required to: 1.Maintain a written respiratory protection.
RESPIRATORY PROTECTION …examination of the appropriate role of personal protection against inhalation hazards.
Respirator Awareness Training CFR
GPHL Respirator Training
NORTH POWERED AIR-PURIFYING RESPITATOR (PAPR) INSTRUCTIONS FOR USE Preventive Medicine Industrial Hygiene Service.
Respiratory Protection Program (RPP) San Joaquin Delta College Revised: 10/05/2011.
PPE Use in Healthcare Settings: How to Safely Don, Use, and Remove PPE
ER1000 ESCAPE RESPIRATOR ONLINE TRAINING Hunterdon County Homeland Security & Hunterdon County Office of Emergency Management May 2004 Made possible through.
M40 FIELD PROTECTIVE MASK
Respiratory Protection
Use and Limitation of N-95 Filtering Facepiece Environment, Health and Safety Occupational Health and Hygiene 2009.
CHEMICAL-BIOLOGICAL MASK: FIELD M40 IAW TM
Unit 7.2. Respirator fit testing TB Infection Control Training for Managers at National and Subnational Level.
2 Fire Fighter Qualifications and Safety Skill Drills.
Introduction Respiratory protection is an essential element to protect employees from possible transmission of Tuberculosis and other infectious diseases.
MAINTAIN YOUR M-40 SERIES PROTECTIVE MASK WITH HOOD
Used with FILTERS Copyright © 2013 by The S.E.A. Group.
Used with FILTERS Copyright © 2013 by The S.E.A. Group.
Radiation Protection Technology Respiratory Protection Air Sampling Radiological Safety and Response RPT-243-PE-6.
Supplied-air hood Copyright © 2013 by The S.E.A. Group.
Used with FILTERS Copyright © 2013 by The S.E.A. Group.
RESPIRATOR FIT QUIZ 1 Respirators prevent you from inhaling dangerous fumes or provide a safe supply of air when you need it. True.
Application and Fit Checking of a P2/N95 Mask. OBJECTIVES Gain skills to effectively don a P2/N95 mask Techniques to ensure a correct fit check of the.
Copyright © 2013 by The S.E.A. Group. Gas and particles There are two major categories of filters: gas filters and particle filters. Gas filters protect.
OSHA’s Respiratory Protection Standard 29 CFR
Copyright © 2013 by The S.E.A. Group. A particle filter can be fitted to the front of a gas filter. Copyright © 2013 by The S.E.A. Group Make a combination.
M40 Series Protective Mask Outlet Valve Outlet Valve Seat
Used with FILTERS Copyright © 2013 by The S.E.A. Group.
Powered Air-Purifying PARTICLE Respirator (PAPR) Copyright © 2013 by The S.E.A. Group.
Fitting of Personal Protective Equipment (PPE) and taking swabs for influenza This presentation is for quick reference only. You must also complete the.
Occupational Safety and Health Course for Healthcare Professionals.
Powered Air-Purifying Respirator (PAPR) Copyright © 2015 by The S.E.A. Group.
Powered Air-Purifying Respirator
Supplied-air regulator Copyright © 2013 by The S.E.A. Group.
Used with FILTERS Copyright © 2013 by The S.E.A. Group Full face respirator.
Personal Protective Equipment (PPE)
1. The 3M manufactures 2 types of Powered Air Purifying Respirator (PAPR) to be worn to provide respiratory protection for those staff members who have.
Personal Protective Equipment
Respirator Safety This Training Covers Respirator Inspection User Fit Checks Respirator Cleaning Respirator Storage.
Respiratory Protection
R espiratory Protection In Compliance With: 29 CFR Cummins Southern Plains, Ltd.
EHSRM (v. 1/04) 1 Environmental Health, Safety and Risk Management Bob Grieshaber Sue Kerns January, 2004.
Respiratory Protection
1 Fire Fighter Qualifications and Safety Skill Drills 2.
1 Skill Drill 2-7 Donning a Face Piece Step 1: Fully extend the straps on the face piece. Step 2: Place your chin in the chin pocket. 2 Step 3: Fit the.
Surface Rescue Swimmer School Mask, Fins, and Snorkel Mask, Fins, and Snorkel LT 4.2.
Medical Skills: PPE -Removing gloves -Donning and removing a gown -Types of isolation.
Protect Yourself From Chemical/Biological Contamination Using Your Assigned Protective Mask.
Scroll Saw Operation and Safety
Chapter 27 Restraint System Repairs. Objectives Explain the difference between an active and a passive restraint system Learn how to service seat belts.
Washington University School of Medicine Medical Student N-95 Particulate Respirator Training.
If you are providing respiratory protection you have, or will arrange face fit testing. You have undertaken a task specific risk assessment and determined.
Alpha Solway Disposable RPE - Designed to Fit.
Copyright © 2016 by The S.E.A. Group
Examples of Applications
Respiratory Protection Program
Respiratory Protection Training
Ballast Dust on Worksites
Click anywhere to get started…
Figure A Figure B 12/07/2006 Rev B
Used with FILTERS Copyright © 2016 by The S.E.A. Group.
PERSONAL PROTECTIVE EQUIPMENT
Copyright © 2016 by The S.E.A. Group
Concorp, Inc. - Respiratory Protection Training. Revision – B
OSHA’s Respiratory Protection Standard 29 CFR
OSHA’s Respiratory Protection Standard 29 CFR
By: Kory Hildebrand PPE.
Presentation transcript:

Menu Copyright © 2005 by The SEA Group negative pressure respirators

Menu Copyright © 2005 by The SEA Group Menu Jump to… Next slide Filters/cartridges Half masks — features Half masks — fitting Half masks — maintenance Half masks — communication Full face masks — features Full face masks —maintenance Full face masks — communication

Menu Copyright © 2005 by The SEA Group The Sundström half mask system Gas filter(s) Particle filter Pre-filter Pre-filter holder Leakage test disk Mask body Inhalation valve Exhalation valve Valve cap Head harness

Menu Copyright © 2005 by The SEA Group FILTERS 1: Particle Filters Skip to Half Masks

Menu Copyright © 2005 by The SEA Group Two main types Mechanical impact (such as Sundström) A fine mesh barrier that lets air through but not particles Electrostatic Electric charged filter material acts like a “glue”, making particles stick to filter surface

Menu Copyright © 2005 by The SEA Group The 1 st problem with ELECTROSTATIC: It’s like throwing tacks at a magnet: Throw them SLOWLY, and the magnet catches them all

Menu Copyright © 2005 by The SEA Group …but throw them QUICKLY, and some will get through The 1 st problem with ELECTROSTATIC:

Menu Copyright © 2005 by The SEA Group The 1 st problem with ELECTROSTATIC: REDUCTION in some filters up to

Menu Copyright © 2005 by The SEA Group So how can electrostatic filters pass standards tests?

Menu Copyright © 2005 by The SEA Group So how can electrostatic filters pass standards tests? Because standards tests are done at 95 litres/minute… …while people often breathe at litres/minute!

Menu Copyright © 2005 by The SEA Group The 2 nd problem with ELECTROSTATIC: Moisture | Humidity | Oil mist

Menu Copyright © 2005 by The SEA Group The 2 nd problem with ELECTROSTATIC: Oil mist is EVERYWHERE!

Menu Copyright © 2005 by The SEA Group Mechanical Impact Not affected by air speed Not significantly affected by humidity or oil mist Only keeps on collecting particles Gets “better” the more particles are caught Replace when hard to breathe through

Menu Copyright © 2005 by The SEA Group Sundström particle filter P100 Dry particles (dust) Wet particles (aerosols, sprays) Smoke and fumes Fibres Mould Bacteria and viruses

Menu Copyright © 2005 by The SEA Group When to replace If there is any damage to the filter or When the filter feels hard to breathe through or After 4-6 weeks’ use

Menu Copyright © 2005 by The SEA Group Comparison Other brands: Every week* Sundström: Every 4-6 weeks Particle filter replacement *) Average filter life 40 hours, as stated by manufacturer

Menu Copyright © 2005 by The SEA Group FILTERS 2: Gas Filters

Menu Copyright © 2005 by The SEA Group Adsorption efficiency of gas filtres NOT affected by air flow rate

Menu Copyright © 2005 by The SEA Group Pulsating air flow MAY affect life span (still 100% adsorption, but time before breakthrough may be shortened)

Menu Copyright © 2005 by The SEA Group Colour coding Organic vapour AmmoniaAcid gas - Inorganic Gas Particles

Menu Copyright © 2005 by The SEA Group Combination filters If you need protection against BOTH particles and gas: A: Use a special combination filter B: Make a combination filter by pressing a particle filter onto the front of a gas filter

Menu Copyright © 2005 by The SEA Group To separate a combination filter Insert a coin or similar between the rim of the particle filter and the lug on the side of the gas filter Twist apart

Menu Copyright © 2005 by The SEA Group When to replace According to a replacement schedule Replacement of gas filters depends on: Type of contaminant Concentration of contaminant Temperature and Humidity Workload

Menu Copyright © 2005 by The SEA Group FILTERS: 3: Pre-filters

Menu Copyright © 2005 by The SEA Group Pre-filters… Should ALWAYS be used Protect the main filter Are low cost items Should be replaced AT LEAST once a day

Menu Copyright © 2005 by The SEA Group Sundström half mask SR100 Skip to Fitting

Menu Copyright © 2005 by The SEA Group Features Mask body and filter holder are made of a SINGLE PIECE of silicone material

Menu Copyright © 2005 by The SEA Group Features Large surface area of the filter holder means a lighter filter and lower breathing resistance

Menu Copyright © 2005 by The SEA Group Features Filter holder situated very low on the mask. This means much better weight balance on the face

Menu Copyright © 2005 by The SEA Group Features Continuous one-piece head harness works like shock absorbers on a car: weight and tension are evenly distributed

Menu Copyright © 2005 by The SEA Group Features Head harness is easily removed for cleaning or replacement

Menu Copyright © 2005 by The SEA Group Features Specially designed valve cups with internal deflectors to eliminate clogging of the valve by spray or aerosols

Menu Copyright © 2005 by The SEA Group Features Exhalation valves have a 90 degree flange to stabilize movement and ensure rapid return to closed position

Menu Copyright © 2005 by The SEA Group Features Sealing surfaces (rims) are sandblasted (matted) for slip-free seal. A deep chin cup ensures secure fit and good balance

Menu Copyright © 2005 by The SEA Group Features The mask if fitted with a water-proof bar-coded name tag for easy identification and tracking

Menu Copyright © 2005 by The SEA Group Features The special test adapter can be used on the wearer’s own mask without leaving any marks

Menu Copyright © 2005 by The SEA Group Sundström SR100 Not designed to suit the standard —— Designed to suit

Menu Copyright © 2005 by The SEA Group Knowledge base A wealth of information and knowledge support is available on CD-ROM and Internet

Menu Copyright © 2005 by The SEA Group Training program Sundström respiratory protection is backed by a solid authorisation program

Menu Copyright © 2005 by The SEA Group How to fit Make sure the mask is: Intact Fully assembled Fitted with correct filters Clean Yours 1 Skip to Maintenance

Menu Copyright © 2005 by The SEA Group How to fit Sling neck strap around your neck Start by placing your chin in the chin cup Cup the mask up over your mouth and nose 2

Menu Copyright © 2005 by The SEA Group How to fit Pull the head strap over your head Head pad should rest on the crest of your head NEVER fit head harness over helmet, cap, ear muffs or other head gear 3

Menu Copyright © 2005 by The SEA Group How to fit Adjust the tension by using the buckle, if needed 4

Menu Copyright © 2005 by The SEA Group How to fit Pull a few times on the BOTTOM strap. This will create more tension in the upper strap, resulting in greater lift and optimum balance 5

Menu Copyright © 2005 by The SEA Group Leakage test Perform a leakage test every time you will use the mask Place the leakage test disk instead of a pre-filter in the pre-filter holder Breathe in and hold your breath The mask collapses against your face. It should stay collapsed until you release your breath. If it returns quickly to normal shape, you have a leakage problem

Menu Copyright © 2005 by The SEA Group Annual fit test Individual fit testing using PortaCount or similar equipment should be performed at least once a year This will ensure that people whose facial features have changed (due to dentures, lost teeth, severe acne, facial scarring etc) are still receiving the protection they need

Menu Copyright © 2005 by The SEA Group Maintenance Skip to Communication

Menu Copyright © 2005 by The SEA Group Maintenance Remove filters Wipe the mask body inside and out with a clean damp cloth Pay special attention to sealing surfaces and filter holder 1

Menu Copyright © 2005 by The SEA Group Maintenance Remove the inhalation valve carefully Check and clean the valve Wipe the valve seat Replace the valve 2

Menu Copyright © 2005 by The SEA Group Maintenance Remove the exhalation valve caps Remove the exhalation valves carefully Check and clean the valves, the valve seats and valve caps Replace the valves and caps Perform a leakage test 3

Menu Copyright © 2005 by The SEA Group Maintenance Clean the head harness with a dry brush Remove the harness if necessary Check that the harness is taut and elastic, otherwise replace 4

Menu Copyright © 2005 by The SEA Group Communication Skip to Full Face Mask

Menu Copyright © 2005 by The SEA Group SmallTalk

Menu Copyright © 2005 by The SEA Group SmallTalk Talk while wearing mask Small size Snap-on fitting High amplification Clear sound Ideal for teamwork

Menu Copyright © 2005 by The SEA Group SmallTalk Microphone snaps on to exhalation valve just like a normal valve cap

Menu Copyright © 2005 by The SEA Group SmallTalk Standard 9V battery Long duration Easy to replace

Menu Copyright © 2005 by The SEA Group SmallTalk Wear speaker unit on waist belt

Menu Copyright © 2005 by The SEA Group SmallTalk Cable clip keeps lead away and prevents snagging and pulling

Menu Copyright © 2005 by The SEA Group Sundström full face mask SR200 Skip to Maintenance

Menu Copyright © 2005 by The SEA Group Features Made of soft, non-allergenic silicone Spherical visor means greater field of vision with less reflection. Face sits further forward in the mask for even better field of vision Uniquely designed, single- action head harness Twin exhalation membranes

Menu Copyright © 2005 by The SEA Group Features Visor available in polycarbonate or laminated glass 1/3 of inhaled air is channeled across the visor, keeping the visor mist-free Exceptionally low weight at 460g (1.0 lb) Head harness of fabric — no sticky rubber on the hair Bar-coded ID tag

Menu Copyright © 2005 by The SEA Group Features Specially designed valve cups with internal deflectors to eliminate clogging of the valve by spray or aerosols

Menu Copyright © 2005 by The SEA Group Features Exhalation valves have a 90 degree flange to stabilize movement and ensure rapid return to closed position

Menu Copyright © 2005 by The SEA Group Features The mask if fitted with a water-proof bar-coded name tag for easy identification and tracking

Menu Copyright © 2005 by The SEA Group Features The special test adapter can be used on the wearer’s own mask without leaving any marks

Menu Copyright © 2005 by The SEA Group Sundström SR200 Not designed to suit the standard —— Designed to suit

Menu Copyright © 2005 by The SEA Group Knowledge base A wealth of information and knowledge support is available on CD-ROM and Internet

Menu Copyright © 2005 by The SEA Group Training program Sundström respiratory protection is backed by a solid authorisation program

Menu Copyright © 2005 by The SEA Group How to fit Make sure the mask is: Intact Fully assembled Fitted with correct filters Clean Yours 1 Skip to Maintenance

Menu Copyright © 2005 by The SEA Group How to fit Sling the neck strap around your neck Loosen the head harness straps Lift the head harness away from the mask body 2

Menu Copyright © 2005 by The SEA Group How to fit First, place your chin in the chin cup Cup the mask up and over your face 3

Menu Copyright © 2005 by The SEA Group How to fit Pull the head harness all the way down to your neck 4

Menu Copyright © 2005 by The SEA Group How to fit Tighten the straps in pairs Start with the BOTTOM pair of straps 5

Menu Copyright © 2005 by The SEA Group How to fit Continue by tightening the MIDDLE pair of straps 6

Menu Copyright © 2005 by The SEA Group How to fit Make sure the mask fits securely. It should not be uncomfortably tight 7

Menu Copyright © 2005 by The SEA Group Maintenance Remove filters Wipe the mask body inside and out with a clean damp cloth Pay special attention to sealing surfaces and filter holder 1 Skip to Communication

Menu Copyright © 2005 by The SEA Group Maintenance Remove the inhalation valve carefully Check and clean the valve Wipe the valve seat Replace the valve 2

Menu Copyright © 2005 by The SEA Group Maintenance Remove the exhalation valve caps Remove the exhalation valves carefully Check and clean the valves, the valve seats and valve caps Replace the valves and caps Perform a leakage test 3

Menu Copyright © 2005 by The SEA Group Leakage test Perform a leakage test every time you will use the mask Place the leakage test disk instead of a pre-filter in the pre-filter holder Breathe in and hold your breath The mask collapses against your face. It should stay collapsed until you release your breath. If it returns quickly to normal shape, you have a leakage problem

Menu Copyright © 2005 by The SEA Group Annual fit test Individual fit testing using PortaCount or similar equipment should be performed at least once a year This will ensure that people whose facial features have changed (due to dentures, lost teeth, severe acne, facial scarring etc) are still receiving the protection they need

Menu Copyright © 2005 by The SEA Group Communication

Menu Copyright © 2005 by The SEA Group SmallTalk

Menu Copyright © 2005 by The SEA Group SmallTalk Talk while wearing mask Small size Snap-on fitting High amplification Clear sound Ideal for teamwork

Menu Copyright © 2005 by The SEA Group SmallTalk Microphone snaps on to exhalation valve just like a normal valve cap

Menu Copyright © 2005 by The SEA Group SmallTalk Standard 9V battery Long duration Easy to replace

Menu Copyright © 2005 by The SEA Group SmallTalk Wear speaker unit on waist belt

Menu Copyright © 2005 by The SEA Group SmallTalk Cable clip keeps lead away and prevents snagging and pulling

Menu Copyright © 2005 by The SEA Group