New Technology for Scintillating Fiber Calorimeters. O.Tsai (UCLA)

Slides:



Advertisements
Similar presentations
New calorimetric technology for eRHIC. O.Tsai (UCLA) BNL, March 9, 2010 Updated, June 1, 2010.
Advertisements

Recent news about SiPM based applications R&D in DESY Nicola D’Ascenzo University of Hamburg - DESY.
Quartz Plate Calorimeter Prototype Ugur Akgun The University of Iowa APS April 2006 Meeting Dallas, Texas.
DREAM Collaboration: Recent Results on Dual Readout Calorimetry. F.Lacava for the DREAM Collaboration Cagliari – Cosenza – Iowa State – Pavia – Pisa –
New Technologies for SciFi Calorimeters. O.Tsai (UCLA) Dec.14, 2010.
W. Clarida, HCAL Meeting, Fermilab Oct. 06 Quartz Plate Calorimeter Prototype Geant4 Simulation Progress W. Clarida The University of Iowa.
Test of the SSD Electronics for the STAR HFT Upgrade Howard Matis - LBNL 1SLAC ESTB Workshop – March 2011.
Testbeam Requirements for LC Calorimetry S. R. Magill for the Calorimetry Working Group Physics/Detector Goals for LC Calorimetry E-flow implications for.
New Calorimeter Technologies for NLC (a) Secondary Emission Calorimeter Sensors (b) Cerenkov Compensated Precision Calorimetry Y.Onel, University of Iowa.
Development of a new detector technology for fiber sampling calorimeters for EIC and STAR. H. Z. Huang, J. Dunkelberger, G. Igo, S. Trentalange, O. Tsai.
Michele Faucci Giannelli TILC09, Tsukuba, 18 April 2009 SiW Electromagnetic Calorimeter Testbeam results.
1 Tianchi Zhao University of Washington Concept of an Active Absorber Calorimeter A Summary of LCRD 2006 Proposal A Calorimeter Based on Scintillator and.
1 C.Woody BNL Summary of the Calorimetry Session PHENIX Upgrade Workshop Dec 14-16, 2010 PHENIX Collaboration Meeting January 11, 2011.
C.Woody BNL sPHENIX EMCAL Conceptual Design sPHENIX Design Study Meeting September 7, 2011.
Heavy Scitillating Crystals and Glasses for a Combined EM and HCal at ILC Tianchi Zhao University of Washigton Sept. 25, 2007.
Status of EIC Calorimeter R&D at BNL EIC Detector R&D Committee Meeting January 13, 2014 S.Boose, J.Haggerty, E.Kistenev, E,Mannel, S.Stoll, C.Woody PHENIX.
The Design of Barrel Electromagnetic Calorimeter (BEMC) October Lu Jun-guang.
Technology Choices for the sPHENIX Calorimeter Systems C.Woody For the PHENIX Collaboration CALOR12 Santa Fe, NM June 5, 2012.
Shashlik type calorimeter for SHIP experiment
Calorimetry: a new design 2004/Sep/15 K. Kawagoe / Kobe-U.
CALICE Meeting DESY ITEP&MEPhI status report on tile production and R&D activities Michael Danilov ITEP.
Status of Projectile Spectator Detector A.Kurepin (Institute for Nuclear Research, Moscow) I. Introduction to PSD. II. Conception and design. III. Development.
Beam test results of Tile/fiber EM calorimeter and Simulator construction status 2005/03/05 Detector Niigata University ONO Hiroaki contents.
R&D on W-SciFi Calorimeters for EIC at Brookhaven E.Kistenev, S.Stoll, A.Sukhanov, C.Woody PHENIX Group E.Aschenauer and S.Fazio Spin and EIC Group Physics.
Shower Containment and the Size of a Test Calorimeter Adam Para, September 6, 2006.
Particle Detectors for Colliders Calorimeters Robert S. Orr University of Toronto.
Scintillation hodoscope with SiPM readout for the CLAS detector S. Stepanyan (JLAB) IEEE conference, Dresden, October 21, 2008.
The Tungsten-Scintillating Fiber Accordion Electromagnetic Calorimeter for the sPHENIX Detector Craig Woody, for the PHENIX Collaboration Physics Department,
Future Beam Test Plans of the GLD Calorimeter Aug 学術創成会議 Satoru Uozumi (Shinshu) for the GLD calorimeter group We are planning to have two beam.
Experimental Particle Physics PHYS6011 Joel Goldstein, RAL 1.Introduction & Accelerators 2.Particle Interactions and Detectors (2/2) 3.Collider Experiments.
Tungsten as HCal-material for a LC at multi-TeV energies CALICE AHCAL Meeting, DESY 17 July 2009 Christian Grefe for the Linear Collider Detector Group.
PID for super Belle (design consideration) K. Inami (Nagoya-u) - Barrel (TOP counter) - Possible configuration - Geometry - Endcap (Aerogel RICH) - Photo.
Lead Fluoride Calorimeter for Deeply Virtual Compton Scattering in Hall A Alexandre Camsonne Hall A Jefferson Laboratory October 31 st 2008.
STUDY OF ULTRAREAR DECAYS K 0 → π 0 νν(bar) (Search of K 0 → π 0 νν(bar) decay at IHEP, project KLOD ) V.N. Bolotov on behalf of the collaboration JINR,
Shashlyk FE-DAQ requirements Pavel Semenov IHEP, Protvino on behalf of the IHEP PANDA group PANDA FE-DAQ workshop, Bodenmais April 2009.
Apollo Go, NCU Taiwan BES III Luminosity Monitor Apollo Go National Central University, Taiwan September 16, 2002.
The Case for the Dual Readout Calorimetry for SiD Adam Para, December 4, 2007.
1 Methods of Experimental Particle Physics Alexei Safonov Lecture #15.
Mechanics and granularity considerations of a Tile hadronic calorimeter for FCC hh barrel Nikolay Topilin/Dubna+ Sergey Kolesnikov/Dubna Ana Henriques/CERN.
DESY Beam Test of a EM Calorimeter Prototype with Extruded Scintillator Strips DongHee Kim Kyungpook National University Daegu, South Korea.
18-23 July 2006J. Hauptman Vancouver LCW06 4th Calorimeter Plans (or dual readout is wonderful, but what are its problems) 1. Electrons and photons limited.
R.S. Orr 2009 TRIUMF Summer Institute
Rare decay Opportunities at U-70 Accelerator (IHEP, Protvino) Experiment KLOD Joint Project : IHEP,Protvino JINR,Dubna INR, Moscow, RAS.
CaTS and Dual Readout. CaTS – Calorimeter and Tracker Simulation Describe detector in gdml file (xml like) Define.
Photon Detector with PbWO 4 Crystals and APD Readout APS “April” Meeting in Denver, CO on May 4, 2004 presented by Kenta Shigaki (Hiroshima University,
DESY Beam Test of a EM Calorimeter Prototype with Extruded Strip Scintillator DongHee Kim Kyungpook National University Daegu, South Korea.
SPHENIX EMCAL R&D Craig Woody BNL sPHENIX Design Study Meeting September 7, 2011.
Edouard Kistenev for the PHENIX Collaboration Calorimetry based upgrade to PHENIX at RHIC CALOR 2012 Santa Fe, NM, June 4-8, 2012.
Imaging Hadron Calorimeters for Future Lepton Colliders José Repond Argonne National Laboratory 13 th Vienna Conference on Instrumentation Vienna University.
Performance of Scintillator-Strip Electromagnetic Calorimeter for the ILC experiment Satoru Uozumi (Kobe University) for the CALICE collaboration Mar 12.
1 Plannar Active Absorber Calorimeter Adam Para, Niki Saoulidou, Hans Wenzel, Shin-Shan Yu Fermialb Tianchi Zhao University of Washington ACFA Meeting.
Simulation studies of total absorption calorimeter Development of heavy crystals for scintillation and cherenkov readout Dual readout in the 4 th concept.
Study of the MPPC for the GLD Calorimeter Readout Satoru Uozumi (Shinshu University) for the GLD Calorimeter Group Kobe Introduction Performance.
DEVELOPMENT OF THE POLYSTYRENE SCINTILLATOR TECHNOLOGY AND PARTICLE DETECTORS ON THEIR BASES VLADIMIR RYKALIN IHEP, PROTVINO INSTR-14, NOVOSIBIRSK, 24.
R&D on a new construction technique for W/ScFi calorimeters. O. Tsai (UCLA), Calor Santa Fe. June 5, 2012.
Future Beam Test Plans of the Calorimeter Group Aug 学術創成会議 Satoru Uozumi (Shinshu) for the GLD calorimeter group We are planning to have two beam.
Ideas for a Tungsten HCal Prototype CALICE Collaboration Meeting, Lyon September 18, 2009 Christian Grefe CERN, Bonn University.
Calorimeters at CBM A. Ivashkin INR, Moscow.
Where are we? What do we want to do next? Some thoughts
Methods of Experimental Particle Physics
IHEP group Shashlyk activity towards TDR
Mickey Chiu University of Illinois at Urbana-Champaign
State-of-the-art in Hadronic Calorimetry for the Lepton Collider
Alternative CEPC Calorimeter
Experimental Particle Physics
R&D for SciFi calorimeters and STAR forward instrumentation upgrades.
Mickey Chiu University of Illinois at Urbana-Champaign
Dual readout calorimeter for CepC
Experimental Particle Physics
Steve Magill Steve Kuhlmann ANL/SLAC Motivation
Presentation transcript:

New Technology for Scintillating Fiber Calorimeters. O.Tsai (UCLA)

Motivation: Develop simple, cost effective, flexible technique to build compact sampling calorimeters with good characteristics. Simple – to the level that a typical university group can build it without heavy investments in “infrastructure”. Cost effective – fraction of the cost of crystals. Flexible – tunable for particular experiment requirements. Idea: Mix tungsten powder and scintillating fibers. Why this particular type?

Simple classification of different sampling calorimeters. I will classify sampling calorimeters in three different groups using this equation. First group has small d and Fs, second has small d but large Fs, and third has large d and Fs. Of course, boundaries are not well defined and there is migration between groups, but in general I think it will work for this discussion. [8] R.Wigmans, Calorimetry, Energy Measurement in Particle Physics. International Series of Monographs on Physics, Vol 107, Oxford University Press.

R.Wigmans, Calor 2010 Fiber calorimeters have a very good record. SPACAL still holds the record for best hadronic resolution. DREAM aims to set new standards in high resolution calorimetry.

(A) Small d, Small Fs This is ScFi calorimeters. Key words: Good energy, position resolution. Fast, compact, hermetic. Problems are; Projectivity, high cost (1/10 th of crystals). Example (H1) Rm 1.8 cm X0 0.7 cm Energy reso. ~ 10% (1 GeV) Density ~ 10 g/cm^3 Number of fiber/tower~ 600 (0.3 mm diameter, 0.8mm spacing) (B) Small d, Large Fs This is “Shashlik” type. Key words: Excellent energy resolution Reasonably fast Small dead areas Problems are: Low density, projectivity. Moderate cost Example (KOPIO/PANDA) 6 cm 3.4 cm 4% 2.5 g.cm^3 0.3 mm Pb/1.5 mm Sc 400 layers (C) Large d, Large Fs Tile/Fiber type. Key words: Ok energy resolution Reasonably fast Very cost effective Problems are: Moderate density, large dead areas. Example (STAR BEMC) 3 cm 1.2 cm 15% 6 g/cm^3 5mm Pb/ 5mm Sc 20 layers We are proposing to develop new technology for (A) but keep the price tag from (C).

What else is so good in ScFi calorimeters that we wanted to develop new technology for this particular type? A bit of propaganda... Can a single detector do it all ?

Small Fs and small d domain. Let’s increase Sampling Frequency to reduce sampling fluctuations for a fixed Sampling Fraction Taken from CERN Yellow report, CERN For fiber calorimeters for equal sampling fraction better resolution for smaller fiber diameter. But no one is building large detectors with fibers smaller than 0.5 mm. New technique required to build ScFi calorimeters with extremely high sampling frequency. Better Resolution

Why do we want to keep Fs small? (Besides compensation) Because we want the detector to be compact, with readout inside the magnet. Readout this- with something like that?

We did a little R&D back in 2003 /2004 in this direction. H1, 0.5 mm fibers 0.8mm spacing. UCLA Mechanical Prototype 0.25x0.25, 0.3 mm fibers, 0.8 mm spacing

We started with very simple “dry” version 4X4 matrix readout by APDs and mesh PMTs We tested it with the beam at SLAC in 2003, and found that it is too simple… That forced us to think a bit more and change technique to “wet”. The second version “spacardeon” has not been tested with the beam for a lot of different reasons… The idea is still need to be proven!

Test Beam Results from SLAC FFTB Goal was to measure resolution, linearity and uniformity Energy resolution for this configuration was modest: 30%/sqrt(E) Biggest problem was uniformity: Factor of 2 drop at corners of modules! Used most beam time to investigate this problem.

Dry prototype was very dense, almost like pure lead (10.3 g/cm 3 ). It has 496 square 0.25mm x 0.25mm fibers inside inside the brass container with walls 62  m thick. 496 instead of 500 and 125  m brass in the corners explains largest variations in response during transverse scans (factor of two). 1.Compactness requires very strict tolerances and homogeneity inside the towers to keep response uniform. 2. Dead materials and areas need to be eliminated. Electromagnetic showers are really very narrow! Uniformity Problem in Test Beam Results

1.Add additional meshes to keep fibers in place along the towers. 2.Learned how to infuse epoxy into powder/fiber mixture. 3.Remove container 4.Additional meshes allow us to wiggle the fibers. Second Prototype Learned by building a few mechanical units which we cut open to see how uniform they are: 2% for 2 cm thickness 2 cm is also the depth we can infuse epoxy without pressure: pull vacuum and let epoxy flow into the assembly Believe we have addressed all mechanical issues with first prototype.

Wiggle or not is a question. However for some applications where channeling is an issue this will help. Plus: Increased sampling frequency for given number of fibers. More fibers will contribute to a signal, thus fiber-to-fiber variations will be diminished. Minus: It is reasonably easy to wiggle 340 fibers of 0.3 mm diameter, but more than that will be a problem. From M.Livan “The art of Calorimetry, Lecture iV”

Plans for 2010: Instrument Second Prototype with MPPC (Multi-Pixel Photon Counters) Install inside STAR Forward Meson Spectrometer Take Data during 2011 Run Plans for 2011: Build 6x6 Matrix Test at FNAL or CERN Tower Size: 2 cm x 2 cm or 2.8 cm x 2.8 cm 20 Radiation Lengths Radiation Length: X 0 = 0.7 cm Moliere Radius: R = 1.8 cm Targeted Energy Resolution: 10%/sqrt(E) Not limit, Reasonable target with standard available meshes. Readout with PMTs to be conservative/No complications w light guides Extensions of this Technique: Stack single towers into larger modules Investigate liquid scintillator or heavy liquids (polymetatungstate/lithium heteropolytungstate) instead of epoxy. Would require containers, but feasible for large modules or as separate hadron calorimeter.

The End

What we want to do this year? Idea still needs to be proven. We want to build a 6x6 matrix and test it next summer at FNAL or CERN. We will use same technique as for our second prototype. The tower size will be the same (2 cm x 2 cm) or slightly larger 2.8 cm x 2.8 cm. Length 20X 0, radiation length and Moliere radius about 0.7 cm and 1.8 cm. Targeted energy resolution 10%/sqrt(E). This is not a limit, it is reasonably good target to prove this technique works. Also standard perforated meshes for this design are available. We want to read out this prototype with PMTs <- conservative, to avoid any complications with light guides etc… At the same time, we want to investigate MPPC (Multi-Pixel Photon Counters) as a possible photo detector. We would like to instrument our second prototype with MPPC and possibly mesh PMTs. Place this detector inside the Forward Meson Spectrometer at STAR and take data with it during Run 11. The goal is to see how well MPPCs behave in a real experimental environment.

Dry prototype was very dense, almost like pure lead (10.3 g/cm 3 ). It has 496 square 0.25mm x 0.25mm fibers inside inside the brass container with walls 62  m thick. 496 instead of 500 and 125  m brass in the corners explains largest variations in response during transversal scans (factor of two). 1.Compactness requires very strict tolerances and homogeneity inside the towers to keep response uniform. 2. Dead materials and areas need to be eliminated. Electromagnetic showers are really very narrow!

'Everything should be kept as simple as possible, but no simpler.' Test setup at SLAC FFTB. Wanted to measure: resolution, linearity, uniformity. From 36 hours of beam time spent most of them by scanning matrix across the face and along the towers, because almost immediately discovered that energy resolution is not what was expected (~30% off from 13%/sqrt(E)), but that wasn’t the biggest problem…

Why is a new generic technology needed? Example: (slide from R.Wigmans talk on Calor2010)

Small Fs is the limiting factor for energy resolution for the two best hadronic calorimeters. Small Fs is required for compensation. In our technique we can use both DREAM method and old compensation approach. However, first we want to reduce sampling fluctuations and keep the sampling fraction low, i.e. preserve compensation and keep detector compact and simple. DREAM method does not require compensation, but limitations right now in level of Cherenkov light (18 phe/GeV, hope to get 100 Phe/GeV see Wigman’s talk), i.e. photostatistic may limit resolution.

What will be interesting to do with this technique? For example, Our second method follows traditional single tower approach, build it one by one then make a stack from them etc… In principle, one can think of building large submodules. There are other ideas on how to make stable assemblies. For example use heavy liquid based on (poly)metatungstate, or lithium heteropolytungstate (LST) instead of epoxy. This would require containers but for larger sub modules this may work (hadron calorimeters for example in scheme where EM and HAD sections separated). Liquid scintillator interesting to try, liquid Xe ? Well, may be not yet. But the idea still has to be proven! We need R&D to continue with this.