Engineering performance of IRIS2 infrared imaging camera and spectrograph V. Churilov, J Dawson, G. Smith, L Waller, J Whittard, R Haynes, A Lankshear,

Slides:



Advertisements
Similar presentations
MMIRS 1 MMIRS MMT and Magellan Infrared Spectrograph Brian McLeod.
Advertisements

GLAO instrument specifications and sensitivities
RF Cavity Module G. Gosling Dept. of Mechanical Engineering Imperial College London.
ARCTIC Post-PDR Optical Design Study
SXC meeting SRON, July 19-20, SXC meeting 19-20/07/2007 Alignment Positioning of mirror with respect to detector (internal). Positioning of total.
Observational techniques meeting #7. Detectors CMOS (active pixel arrays) Arrays of pixels, each composed on a photodetector (photodiode), amplifier,
Transmission Machine Components
4m Undulator Design Concepts Amanda J Brummitt CCLRC RAL On behalf of the HeLiCal Collaboration.
1 Update on Focus Coil Design and Configuration M. A. Green, G. Barr, W. Lau, R. S. Senanayake, and S. Q. Yang University of Oxford Department of Physics.
The Research School of Astronomy and Astrophysics of the Australian National University at Mt Stromlo Observatory is developing a wide-field Cassegrain.
IRMS Optical Subsystem Review. The Charter Confirm that the MOSFIRE design is a feasible baseline for IRMS (yes) Verify that the MOSFIRE design can achieve.
PLATO kick-off meeting 09-Nov-2010 PLATO Payload overall architecture.
1 NGAO Science Instrument Reuse Part 1: NIRC2 NGAO IWG December 12, 2006.
MMT Magellan Infrared Spectrograph ( MMIRS ) P.I. Brian McLeod Warren R. Brown SAO/CfA.
Mechanical Transmissions
Rolling element bearings A. Lozzi 09
Conventional and Computed Tomography
Integration and Alignment of Optical Subsystem Roy W. Esplin Dave McLain.
Lathe and drilling machines
Oct 17, 2001SALT PFIS PDR - Structure1 Structure Interface/ constraints Loads Structure design rationale Truss Weight and CG Finite Element Analysis/ Image.
AAOmega: a Multi-purpose Fiber-fed Spectrograph for the AAT Greg Smith 1 Will Saunders 1 Terry Bridges 2, Vladimir Churilov 1,
CT Quality Control for CT Scanners. Quality Control in CT A good idea? Yes Required for accreditation? Sometimes Improves image quality? Sometimes Depends.
Sonia Cianci a,b, Joss Bland-Hawthorn b and John O’Byrne a a University of Sydney, Australia b Anglo-Australian Observatory Designing ultra-narrowband.
Progress on the MuCool and MICE Coupling Coils * L. Wang a, X. K Liu a, F. Y. Xu a, A. B. Chen a, H. Pan a, H. Wu a, X. L. Guo a, S. X Zheng a, D. Summers.
22 February 2006 Quo Vadis ? Wide Field Imaging A Wide Angle Very Low Threshold Air Cherenkov Imaging Telescope Razmick Mirzoyan MPI Munich, Germany.
ZTF Cryostat Finite Element Analysis Andrew Lambert ZTF Technical Meeting 1.
SALT Technology Development Lisa Crause India-South Africa Astronomy Workshop – SAAO 6 August 2012.
July 13, 2006, Starsplitters of Wyalusing 1 TPoint What the is Bisque doing now?
Universities Space Research Association Page 1 HAWC Optical and Photometric Specifications 27 July 2007.
Engineering: NAHUAL Ireland Acquisition Camera, Focal Plane Mechanisms and Layout Tully Peacocke, National University of Ireland Maynooth Carlos del Burgo,
Lathe and drilling machines
Peter Gillingham, Stan Miziarski, and Urs Klauser (Anglo-Australian Observatory) Figure 1 View of OzPoz showing the front of the focal late in observig.
STATUS REPORT OF FPC SPICA Task Force Meeting March 29, 2010 MATSUMOTO, Toshio (SNU)
Status Report on Mk.II Pepperpot Simon Jolly Imperial College 13 th June 2007.
MARS 2 Design Review-Optomechanical Review 07 Nov 2002 GLW1 MARS 2 Mechanical Design Review.
1 of 28 A design study of a Cryogenic High Accurate Derotator.
HAMBURG BEAM PIPE POSSIBLE LAYOUT AND MANUFACTURING JANUARY 2012.
Multi-slit spectroscopy In sky-noise dominated conditions (most interesting!) the use of slits is essential: eg: Faint object, extra-galactic, surveys:
FLAO system test plan in solar tower S. Esposito, G. Brusa, L. Busoni FLAO system external review, Florence, 30/31 March 2009.
NIRSpec Operations Concept Michael Regan(STScI), Jeff Valenti (STScI) Wolfram Freduling(ECF), Harald Kuntschner(ECF), Robert Fosbury (ECF)
NORDFORSK Summer School, La Palma, June-July 2006 NOT: Telescope and Instrumentation Michal I. Andersen & Heidi Korhonen Astrophysikalisches Institut Potsdam.
ASTR 3010 Lecture 18 Textbook N/A
Cavity support scheme options Thomas Jones 25/06/15 to 06/07/15 1.
January 25, 2005GRETINA 2004 Review1 GRETINA 2004 Annual Review Steve Virostek Lawrence Berkeley National Lab Mechanical System.
Henry Heetderks Space Sciences Laboratory, UCB
Oct 17, 2001SALT PFIS Preliminary Design Review1 Southern African Large Telescope Prime Focus Imaging Spectrograph Mechanical Mechanism Design Michael.
SEPTEMBER 2002 Pixel Support Tube A. Smith LBNL 1 ATLAS Pixel Detector Heater Panel Testing Alexis Smith September 17, 2002.
Gandhinagar Institute of Technology
Aerodynamic forces on the blade, COP, Optimum blade profiles
Oct 17, 2001SALT PFIS Preliminary Design Review Control System 1 Southern African Large Telescope Prime Focus Imaging Spectrograph Preliminary Control.
SHAPER, SLOTTER & PLANER SUBMITTED TO PROF. DEEPAK SHARMA SUBMITTED BY ANKIT SHARMA ME-I (III YEAR)
Cavity support scheme options Thomas Jones 25/06/15 1.
N A S A G O D D A R D S P A C E F L I G H T C E N T E R I n s t r u m e n t S y n t h e s i s a n d A n a l y s i s L a b o r a t o r y APS Formation Sensor.
MPI Semiconductor Laboratory, The XEUS Instrument Working Group, PNSensor The X-ray Evolving-Universe Spectroscopy (XEUS) mission is under study by the.
MMIRS 1 Harvard-Smithsonian Center for Astrophysics Magellan SAC 9/05 MMIRS Status Upate Presented by A. Szentgyorgyi P.I. B. McLeod.
1 ATLAS Muon Spectrometer Alignment LHC Days in Split, 5-9 Oct J.Krstic, M.Milosavljevic Institute of Physics, Belgrade D.Fassouliotis,C.Kourkoumelis,
F. Pepe Observatoire de Genève Optical astronomical spectroscopy at the VLT (Part 2)
Date of download: 5/29/2016 Copyright © 2016 SPIE. All rights reserved. Drawing of the Space Infrared Telescope for Cosmology and Astrophysics (SPICA)
NIRSpec - the JWST Multi-Object Spectrograph P. Ferruit (ESA), S. Arribas (CSIS), S. Birkmann (ESA), T. Böker (ESA), A. Bunker (Oxford), S. Charlot (IAP),
Astronomical Spectroscopic Techniques. Contents 1.Optics (1): Stops, Pupils, Field Optics and Cameras 2.Basic Electromagnetics –Math –Maxwell's equations.
Assembly, Alignment, and Maintenance of an Automated Laser Cutter Zhenghao Ding, Lunjun, Gabriel Spalding* Physics Department, Illinois Wesleyan University.
Superconducting Cryogen Free Splittable Quadrupole for Linear Accelerators Progress Report V. Kashikhin for the FNAL Superconducting Magnet Team (presented.
Single Object Spectroscopy and Time Series Observations with NIRSpec
Diagnostic Radiology II X-ray Tubes. Anode angle Anode angle defined as the angle of the target surface with respect to the central ray in the x-ray field.
Linescanner MP150 Infrared Temperature Measurement for Quality Control and Process Automation Raytek Confidential 10/2010, Rev. B.
Astronomical Spectroscopic Techniques
iSHELL Design Review Cryostat & Optics Bench
Henry Heetderks Space Sciences Laboratory, UCB
Considerations about triangular and L-shaped detectors
Presentation transcript:

Engineering performance of IRIS2 infrared imaging camera and spectrograph V. Churilov, J Dawson, G. Smith, L Waller, J Whittard, R Haynes, A Lankshear, S Ryder, C Tinney The IRIS2 instrument is a near infrared (λ = 0.9 to 2.5 μm) imager and spectrograph for use on the Anglo Australian Telescope (AAT). Primarily it is used at the Cassegrain focus, with the telescope in the F/8 wide field configuration (8 x 8 arcminutes). It may also be used in the F/15 and F/36 Cassegrain configurations providing different image scales and field sizes. At F8 it has a single 1arcsecond slit, and 3 multislit stations offering multiple 1 arcsecond slits on specially produced masks. Structure. The potential for misalignment caused by structural deflections led to a scheme for the internal structure where the plate (main structural plate) between the main and fore vessels was the common foundation for a pair of hexapod trusses (Stewart platforms). The truss within the main vessel carries the wheels housing, to which the collimator and camera assemblies and the detector are attached. This housing contains the filter, cold stop and grism wheels. The truss in the fore vessel carries the slit wheel housing. The lengths and angles of the truss members are determined by the locations of the wheel housings relative to the main structural plate. However, inspired by Serrurier, the cross sections of these truss members have been proportioned so the transverse deflections of the fore and main vessel wheel housings are identical and there will be no relative motion, and thus minimal drift of the slit image on the detector. The housings also remain parallel to one another and to the main structural plate. The success of this design has been ratified by deflection tests, where the flexure of components in the slit wheel have been examined with respect to the detector. A matrix mask, comprised of a grid of 75μm holes on a 3mm pitch, was placed in the slit wheel. This showed that the slit wheel moved relative to the detector by approximately by 0.5 pixels (~9μm) when the telescope is moved from Zenith to 60° in an East-West (E-W) direction. No perceptible flexure can be seen when the telescope is slewed in the North-South (N-S) direction. The external structure for attachment to the Cassegrain focus was designed and built in a similar manner to the internal structure. IRIS2 Internal IRIS2 External Mechanisms. To accurately position the wheels a worm and gear system was developed, utilising stepper motors adapted for vacuum cryogenic operation. The worms are mounted on a flexure assembly that allow the worms to be deflected, preventing excessive loads, during cooling as the shell of the assembly contracts at a faster rate than the gear wheel. Solenoids control the gear set engagement, the solenoid is engaged to drive the gear, pulling the worm slightly away from the wheel thus allowing it to drive on one active flank. Once at position the solenoid is disengaged and the worm locks the combination in position. The solenoids themselves are also mounted on flexures that allow them to be deflected during the cooling process. The worm assembly flexure mechanism is designed to give an effective centre of rotation at its centre of mass, so the worm engagement is independent of instrument orientation. An encoding system using infrared sensors in a non-standard manner, to allow cold operation, provides feedback for the wheel drive system. To trim focus of the instrument a detector translator is provided, which compensates for drifts due to thermal effects and small errors in manufacture or assembly. This mechanism, implemented using flexures, translates the detector assembly  0.4mm along the optical axis from the nominal focus position. The repeatability of the wheel repositioning, as proven with tests on the slit wheel, has been demonstrated to be within 0.1 arcseconds (7μm) of the previous position. All mechanisms have proven extremely reliable in service with no instrument downtimes being attributable to the drive mechanisms. Thermal and Vacuum. Refrigeration for the two vessels is provided by Gifford-McMahon cryorefrigerator. The detector operates at 66K and is controlled by over cooling and then using a strain gauge heater to maintain the stabilized temperature. The main vessel wheels and housing, collimator and camera, and various baffles operate between 75K and 100K. The slit wheel and its housing operates at around 110K and can be controlled via a similar heating system as employed on the detector Image Quality. With a matrix mask (75μm holes on a 3mm pitch) installed in the slit wheel it was possible to test the intrinsic image quality of the IRIS2 optical train. Although manufacturing tolerances meant that there is some variation in the diameters of these mask holes, the mask permits precise evaluation of IRIS2's image quality as a function of camera focus across the whole field. While there is some curvature of the IRIS2 focal plane at the detector, this is sufficiently small that a best focus can be achieved delivering images of <1.2 pixels Full Width Half Maximum (FWHM) over the whole field. Given the mask itself delivers pixel (FWHM) images, the image quality of the IRIS2 optical train is clearly excellent - better than 0.3 arcseconds over the whole field. Best camera focus seems to decrease by ~35 motor micro-steps (22μm) when the telescope is moved off the vertical (in any direction) by a Zenith Distance (ZD) of 41°. However tests have shown that adjustments of up to 75 motor micro steps have very little impact and can be neglected. Mode Read Time (s) Gain (e/adu) Read Noise (e) Typical Read Noise (e) Full Well (ke-) Non- linearit y (at Full Well) DRM (2 reads) 180 ~1% MRM (61reads) 75 ~0.3% Detector Performance. IRIS2 uses a HAWAII   m pixel HgCdTe detector, driven by the AAO’s new generation AAO2 Optical Detector Controllers (ODC). The detector performance of the combined HAWAII1 and AAO2 system delivers is summarized in the Table below. The detector is used in two modes: for high background imaging observations where readout speed is critical, a Double Read Mode (DRM) is employed. In low-background spectroscopic applications, where exposures are longer and read noise is critical, Multiple Read Mode (MRM) is employed. The array is reset and then non-destructively read repeatedly throughout the specified exposure time Measured dark current performance is typically e-/s. The cosmetic quality of the array as delivered by the AAO2 ODC is excellent (see below right). These combined parameters give IRIS2 excellent read-noise/dark current performance for observing in low- background applications such as R=2400 spectroscopy in the J and H passbands. Main Wheel Assembly Detector PerformanceDRM Mode MRM Mode The wide field-of-view and collimator-camera design of IRIS2 naturally raised the prospect of multi-object spectroscopy early in the instrument’s planning phase. So a system for installing up to 3 Multi-Object Spectroscopy (MOS) masks in the slit wheel was implemented. The multi-slit masks for IRIS2 are laser cut from 100  m thick, chemically-blackened brass sheet (see above). Differential contraction between the brass masks and the aluminium wheels could result in buckling of the masks as they are cooled to their working temperature. To prevent this, the mask is mounted in a brass frame of two parts: a clamping plate; and a carrier plate. Differential thermal contraction is accommodated by incorporating three flexures in the carrier plate. All masks are manufactured with an asymmetric set of holes around their perimeters so that they cannot be incorrectly loaded in their frames. The three masks can be exchanged on a timescale of days, allowing for the vessel to be warmed and re-cooled. 1. Main structural plate 2. Detector assembly 3. Wheels assembly (filter, cold stop and grism wheels) 4. Slit wheel assembly 5. Anti-vibration mounts 6. Cryocoolers 7. Camera assembly 8. Collimator assembly 9. Field lens 10. Window 11. Multilayer insulation 12. Detector controller 13. Electrical connectors Multislit Mask Assembly Mask CuttingMOS Mask Image of ρ Ophiuchus Obtained with IRIS2