The New Low Lead Regulations 2014 AWWA Meeting February 26, 2014 LAURA A. TAYLOR (334) 271-7820

Slides:



Advertisements
Similar presentations
City of Milwaukee Cross Connection Program Construction Trades Division Cross Connection Section.
Advertisements

Cross-Connections Gary Carlson Drinking Water Program U.S. EPA Region 8.
Do You Comply? On January 4, 2014, water works brass will change forever.
HEADING size 54 Arial TEXT size no small than 28 Arial SUB-HEADING size 44 Arial AS/NZS 4020 Testing of products for use in contact with drinking water.
Backflow Preventers. Cross Connection Direct arrangement of piping which allows the potable water supply to be connected to a line which contains a contamination.
2012 Plumbing Codes International Plumbing Code Uniform Plumbing Code David McCarthy, P.E. City of Phoenix.
September 29-30, 2011 Drinking Water Program Sustained Compliance Workshop Lee Johnson, P.E
Equipment and Facilities. 154 Plan Review The local health department must assess your facility and equipment before: –Beginning construction of a food.
Potential Pathways for Coliform Contamination. Fixing Positive Coliform Results.
Lead-Free Law Overview (and what it means to you) Rick Fields Zurn Wilkins.
How to Identify Lead-Free Certification Marks for Drinking Water System & Plumbing Materials Michelle Latham Biologist  Technical Communications Water.
Gas Transmission Pipelines
POTABLE WATER AND GRAY WATER TRUCKS. VEHICLE HEAVY EQUIPMENT SAFETY INSPECTION CHECKLIST OF 296.
1 Department of Toxic Substances Control - Office of Pollution Prevention and Green Technology Multimedia Products Unit Andre Algazi - DTSC
December 1, 2011 Jeff Hebenstreit - UL
LOCKOUT/TAGOUT.
Al Fuentes Technical Review and Oversight Team Water Supply Di vision Your Public Water System’s Cross- Connection Control Program.
SDWA1 The Safe Drinking Water Act (SDWA) The Safe Drinking Water Act (SDWA)
PRESENTED BY: NAMA’S GOVERNMENT AFFAIRS DIVISION ERIC DELL SENIOR VICE PRESIDENT Reduction of Lead in Drinking Water Act NAMA Webinar.
5.1.2 Student Book © 2005 Propane Education & Research CouncilPage 1 NFPA 58, LP-Gas Code, sets out the minimum valve and fitting requirements for propane.
NSF/ANSI 61 Drinking Water System Components - Health Effects Acceptance criteria….. Regulated contaminants: Includes USEPA and Health Canada regulated.
Adoption and Enforcement of NSF 372 What Devices Need to Comply Presented by: Julius Ballanco, P.E.
"Welder Certification" The purpose of this presentation is to introduce you to the various aspects of welder certification. This is not intended to cover.
Lead Free in 2014 By Darnell Wesson. Lead Free: What is it about? Codes and Standards Bradley and Lead Free Bradley and Lead Free Review Questions & Answers.
WQA Issue Document Electrical Compliance in DWTU Standards NSF/ANSI Standards 42, 44, 55, 62, and 222.
1-1. Key Sanitation condition No. 1:  Safe supply for water that contacts food and food contact surfaces;  Safe water supply for production of ice; and.
Lead Dust Sampling Technician March Chapter 1 Introduction.
Implementing Rain Water Harvesting into Building Construction in VA Presented by: Guy Tomberlin, CBO Code Specialist III Fairfax County DPWES, Land Development.
U D T Workshop on the Pressure Equipment Directive, Warsaw June 2004 INTERFACES BETWEEN NATIONAL LEGISLATION AND DIRECTIVE 97/23/EC SYSTEM OF ENSURING.
Maryland Farmers’ Market Conference: Food Safety Regulations February 28-29, 2012 Sherry Donovan-Morris, REHS/RS Section Head, Division of Facility &
Codes, Standards & Conformity Assessment GP Russ Chaney CEO, The IAPMO Group
FHM TRAINING TOOLS This training presentation is part of FHM’s commitment to creating and keeping safe workplaces. Be sure to check out all the training.
No Lead Laws & Regulations Tampa Bay Area Coop Meeting March 27, 2013.
© 2009 Michigan State University licensed under CC-BY-SA, original at Water Quality.
Air Conditioning International Mechanical Code
NSF International Drinking Water Product Standards.
Centrally Managed POU Treatment for Compliance with the Arsenic Rule Grimes Study USEPA December 1, 2004.
Rigid Plastic Packaging Container (RPPC) Informational Update Permitting and Compliance Committee Meeting February 17, 2009.
Environmental Standards and the GS-37 Revision Cheryl Baldwin, Ph.D. Vice President of Science and Standards Green Seal, Inc. NEWMOA April 1, 2008.
Proposed Rule for Preventive Controls for Animal Food.
Proposed Rule: 21 CFR 507 Proposed Rule for Preventive Controls for Animal Food 1.
Backflow Prevention for Fire Sprinkler Systems State of Illinois Plumbing Code.
Do You Comply? On January 4, 2014, water works brass will change forever.
Introduction to NSF Lead Leaching NSF 61 Safe Drinking Water Act Revision Lead Content Standards – NSF 61-G – NSF 372 Marking.
Purpose of Water Treatment c. Safe Drinking Water Act and SDWA amendments.
Workshop on Permanent Closure of Single-Walled USTs and Funding Opportunities For Closure and Cleanup.
HazCom 30 CFR Part 47 (Interim Final Rule) Telling Miners about Chemical Hazards.
SUPPLEMENTAL ENVIRONMENTAL PROJECTS. KEY CHARACTERISTICS OF A SEP Projects must improve, protect or reduce risks to public health or environment. Projects.
CPSC AND THE POISON PREVENTION PACKAGING ACT John W. Boja, Ph.D. These comments are those of the CPSC staff, have not been reviewed or approved by, and.
JLAB Pressure Systems Considerations Ed Daly. Outline Introduction Federal Law - 10CFR851 Compliance JLAB Pressure Systems Program –Complies with 10CFR851,
Metrology Regulatory and Obsolescence Strategy Andrea DavisBridget Berardinelli.
Aberdeen S.D. Community Meeting Aberdeen S.D. Community Meeting Presenters: Mr. Brad Olson, President Aberdeen School Board Mr. Tom Opstad, Superintendent.
Every employer must ensure, as far as is reasonable practicable, the health, safety and welfare of all his employees More specifically, employers must.
CROSS CONNECTION CONTROL PROGRAM
Outline Background on Lead in Drinking Water How Lead is Regulated
Preventing Exposure to Lead in Drinking Water
Cross Connection Survey Training
Backflow Prevention and Cross Connection Control Update
A Coordinated Approach to Reduce Potential Lead Exposure
Your Public Water System’s Cross-Connection Control Program
Changes to Exempt Categories
Lead in Drinking Water Forum
NSF International Drinking Water Product Standards
Lead Content Calculation
Safe Drinking Water Act (SDWA)
Changes to Exempt Categories
Preventing Exposure to Lead in Drinking Water
RCRA Updates Larry L. Lamberth Enforcement and Compliance Branch
See for Yourself! What’s in Your Water?
Gas Transmission Pipelines
Presentation transcript:

The New Low Lead Regulations 2014 AWWA Meeting February 26, 2014 LAURA A. TAYLOR (334)

Overview Sources of Lead in Drinking Water Health Affects of Lead in Drinking Water Current Safe Drinking Water Act Requirements NSF/ANSI 61 Safe Drinking Water Act Revisions Issues with the Revisions Certification Labeling Examples Questions

Sources of Lead in Drinking Water Sources of lead – Natural deposits – Household plumbing materials – Water service lines – Homes built before 1986 Most common problem – brass or chrome-plated brass faucets and fixtures Lead is rarely found in source water

Health Affects of Lead in Drinking Water Affect on adults – Increase blood pressure – Kidney problems Affect on children – Delays in physical and mental development – Slight deficits in attention span – Learning disabilities

Current SDWA Requirements SDWA 1417(a)(1)(A) – No person may use any pipe, plumbing fixture, solder, or flux that is not lead free, after June 19, 1986 for installation or repair of: any public water system any plumbing in a facility providing water for human consumption

Current SDWA Requirements SDWA 1417(b) State Enforcement – States shall enforce the lead free requirements through State or local plumbing codes, or other such means of enforcement as the State may determine to be appropriate. SDWA 1417(c) Penalties – EPA may withhold up to 5% of Federal funds available to the State under 1443(a) if the State does not enforce the lead free requirements.

Current SDWA Requirements 1417(d) Definition of lead free – Solders and flux cannot contain more than 0.2% lead – Pipe and fittings cannot contain more than 8.0% lead The standard for lead free plumbing fittings and fixtures is established in Section 9 of NSF/ANSI Standard 61

NSF/ANSI Standard 61- Scope Pipes and Related Products (pipe, hose, fittings) Protective and Barrier Materials (cements/coatings) Joining and Sealing Materials (gaskets, adhesives, lubricants, solvent cements) Process Media (activated carbon, filter media) Mechanical Devices (water meters, valves, filters) Mechanical Plumbing Devices (faucets, drinking fountains, and components)

NSF/ANSI 61 lead content restrictions There should be no lead added as an intentional ingredient in any product, component, or material submitted for evaluation to this standard, with the following exceptions: – Brass or bronze meeting the definition of “lead free” – Materials of components with a diluted surface area less than or equal to in 2 /L

NSF Standards Development Process

Certification Marks

Safe Drinking Water Act Revisions Overview Amends SDWA Section 1417 – Creates exemptions – Changes the definition of lead free Reduces lead content from 8.0% to a weighted average of 0.25% in the wetted surface material (primarily affects brass/bronze). – Eliminates provision that certain products comply with voluntary standards for lead leaching. – Establishes statutory requirement for calculating lead content – Effective date January 4, 2014

Safe Drinking Water Act Revision Exemptions 1417(a)(4)(A) – pipes, pipe fittings, plumbing fittings, or fixtures, including backflow preventers, that are used exclusively for non-potable services such as manufacturing, industrial processing, irrigation, outdoor watering. – or any other uses where the water is not anticipated to be used for human consumption

Safe Drinking Water Act Revision Exemptions 1417(a)(4)(B) – toilets, bidets, urinals, fill valves, flushometer valves, tub fillers, shower valves, – service saddles, or water distribution main gate valves that are 2 inches in diameter or larger. Note: Any item covered by either exemption can have any amount of lead. Also, meters have not been exempted.

Safe Drinking Water Act Revision Exemptions Fire Hydrants Fire Hydrants has been exempted. – Became Public Law on 12/20/2013 – Community Fire Safety Act of 2013 – H.R. 3588

Safe Drinking Water Act Revisions Definitions 1417(d) Definition of lead free – Revises lead content from 8% to not more than a weighted average of 0.25% with respect to the wetted surfaces of pipes, fittings, and fixtures. – Provides calculation procedure for determining the weighted average lead concentration of a product from the components that make up the product. – Eliminates requirement that certain products comply with standards for lead leaching (NSF/ANSI Standard 61 Section 9)

NSF Evaluations

Safe Drinking Water Act Revision Lead Content Calculation Core requirement: Weighted average lead content < 0.25% Formula:

Sample Faucet

Example weighted average lead content calculation

Safe Drinking Water Act Revisions Effective Date Effective Date January 4, 2014 – A product introduced into commerce legally on January 3, 2014 can’t be used on January 4, 2014 – The effective date will affect plumbers, plumbing product retailers, developers, schools and water systems – Any inventory that does not meet 0.25% lead free calculation cannot be installed after January 3, 2014, unless it is exempt from the prohibitions.

Issues With the Revisions Overview Demonstrating that products are lead free Scope of the exemptions Identifying non-potable products if dual product lines are allowed Identifying lead free products Calculating lead content Repairing and returning products to service

Demonstrating Products are Lead Free Should manufacturers be required to demonstrate that a product is lead free and if so how? Potential approaches – Require manufacturers to have products certified by a qualified independent third party (e.g., NSF/ANSI Standard 372 certification)

Scope of the Exemptions To qualify for the “used exclusively for non- potable services,” must the product be physically incapable of use in potable services or could it be physically capable of use in potable services? Potential approaches – Allow interchangeable dual product lines labeling the non-potable version as “not for potable use.” – All interchangeable products must meet the new lead free content limit.

Identifying Non-Potable Products if Dual Products Lines are Allowed If dual product lines are allowed, what kind of label should be used? Potential approaches – Require labeling of package – Require labeling of product – Require labeling of package and product

Identifying Lead Free Products How can consumers know if a product meets the revised lead free definition? Potential approaches – Require independent third-party certification including certifier’s mark – Require manufacturers to label products if certification is not done via a third-party certification – Do not require labeling of lead content Just label as non-potable

Calculation of Lead Content What constitutes the lead content of the material used to produce wetted components? Potential approaches – Lead content at the surface of the product is used – Lead content of the alloy used to produce the wetted component is used and not just the lead at the surface layer Acid washing issue Coating erosion issue This approach is consistent with NSF/ANSI Standard 372

Repairing and Returning Products to Service Can a product in the system be repaired using lead free component parts and returned to service even if other component parts were not repaired and are not lead free? Potential approaches – Entire unit would need to meet lead free requirement – Only components replaced would need to meet lead free requirement

Certification Labeling Examples

Questions Laura A. Taylor Drinking Water Branch - ADEM (334)