PERMITS & INSPECTIONS DEPARTMENT 2003 INTERNATIONAL RESIDENTIAL CODE IRC.

Slides:



Advertisements
Similar presentations
7 | Means of Egress (Life Safety Code)
Advertisements

Presents 2012 Revisions to the NC Energy Code For Residential Building started after March 1, 2012.
Guidelines and Required Codes That Affect Building Design
Manufactured Home Installer CE Course Approved by the Department of Safety & Professional Services – Approval # Presented by the Wisconsin Housing Alliance.
DEPARTMENT OF DEVELOPMENT SERVICES BUILDING DIVISION Ronald L. Lynn, Director/Building Official Gregory J. Franklin, Assistant Director Neil Burning, Manager.
Copyright 2006 Assurance Check, LLC ICC Boot Camp Instructor Greg Bell Greg Bell.
Civil Engineering & Architecture 2.3 Residential Design.
State of Virginia’s Adoption Uniform Statewide Building Code –Adopts model codes by reference Family of I Codes 2003 edition NEC 2002 edition –Statewide.
IRC 2009 Habitable Attics.
Michigan Department of Licensing and Regulatory Affairs Bureau of Construction Codes.
Visitability Standards Dan McNabb, Deputy Building Official Planning and Development Review Department.
Oklahoma Uniform Building Code Commission IRC Building Subcommittee Presentation to Commission November 17, 2010.
PowerPoint Presentation
IBC 2006 Chapter 5 Building Height and Areas After determining occupancies, the code analysis determines what height and areas are allowable for the occupancy.
Creating a section view using floor plans
Amendment to GPDO Householder Permitted Development.
Chapter 8 Plot Plans.
2012 International Fire Code Adopted as the minimum fire safety standard by the State of Wyoming City of Sheridan must adopt the minimum standard to retain.
Floor Systems and Foundation Support
ASSIGNMENT Begin on page 197 “The Foundation”.
Architectural Design Construction of a Wall Section Upon completion of this assignment, you will be able to accurately and neatly draw, to scale and limits,
PERMITS & INSPECTIONS DEPARTMENT
Tom Kader Chief Electrical Inspector Spaces About Electrical Equipment Sufficient access and working space shall be provided and maintained about.
PERFORMANCE & CODE ANALYSIS TIMBer Inc. ·Brooke Fedder · Marie Rottschaeffer· Izzie Molinuevo· Tena Pettit·
Construction Residential Houses Definition of a House: A structure serving as a dwelling for one or more persons, especially for a family.
Building Codes and Interior Design
© 2006 ITT Educational Services Inc. CD230 Architectural Design & Drafting: Unit 10 Slide 1 Unit 10 Commercial Construction.
Insulation and Infiltration
State of Virginia’s Adoption Uniform Statewide Building Code –Adopts model codes by reference Family of I Codes 2003 edition NEC 2002 edition –Statewide.
Chapter 32 Floor Systems and Foundation Support. 2 Links for Chapter 32 Slab Construction Reinforcing Concrete Crawl Spaces.
QUIRKY HQS INSPECTIONS Seanna Collins Lincoln Housing Authority September 16, 2015.
Building Codes Intended to protect the public by establishing minimum standards of building safety.
Chapter 23 Elevation Layout and Drawing Techniques.
EDT Elevations1 Weekend Cabin Retreat Project Elevations Sacramento City College EDT 300/ENGR 306.
Competency: Draw wall sections and details
MINNESOTA CHAPTER AUTOMATIC FIRE ALARM ASSOCIATION Requirements of the 2003 Minnesota State Fire Code relating to Group R Occupancies September 14, 2006.
Code Officials and the Code Process.  To design the interior of the building in conjunction with codes, standards and federal regulations required in.
EDT Cabin Design Project - Elevations1 Weekend Cabin Retreat Project Elevations Sacramento City College EDT 300 Kenneth Fitzpatrick, P.E.
Engineering Analysis of NFPA 285 Tested Assemblies
Chapter 28 Structural Components of Framed Construction.
Affordable housing project
Means of Egress Part 3 Chapter 4.
Maine State Fire Marshals Office1 Laws and Codes Relating to Existing Apartment occupancies in the State of Maine Mark Stevens CFI-II, CFPS, CFPE Inspections.
AT – 201 Introduction to Architecture Dan Trent August 28,
ASSIGNMENT 1.Begin on page 177 “The Foundation”. 2.Complete “Footing and Foundation”, “Floor and Wall Frame”, “Roof Frame” 3.Label each part of the diagram.
© Goodheart-Willcox Co., Inc. Permission granted to reproduce for educational use only 1 Learning Objectives Identify the primary features included in.
Fire Resistance Rated Truss Assemblies Educational Overview.
Work Area Method Level 3 Alterations – Chapter 9 prescribes requirements. 50% of Building Area Rule.
2012 Building Codes Take Effect MAY 1st IRC Transition from the 2006 IRC Based on the 2006 International Residential Code ® (IRC ® ), the 2009 International.
VIRGINIA RESIDENTIAL CODE
2012 Building Codes Take Effect MAY 1st
Construction Foundations of Technology Construction © 2013 International Technology and Engineering Educators Association STEM  Center for Teaching and.
Drafting 2 (Arch) Quiz Review #6 Quiz Review. 1.To anchor a stud wall to the subfloor, carpenters nail through the: Sole plate Header Jamb Joists Quiz.
Amendments to the Town and Country Planning (General Permitted Development) Order 2008.
Floor Systems and Foundation Support
IRC 2009 OVERALL. SITE PLAN PROPERTY LINES LOCATION OF BUILDING GRADES STREETS.
CAD-Architecture Inst: Mr. Johnston Logan High School
CITY OF HARARE EMERGENCY SERVICES
Competency: Draw wall sections and details
AR-315 BUILDING CODES & BYE LAWS
Elevation Layout and Drawing Techniques
CEN 180: Civil Engineering Drawing II
Objective 6.02 part 1: Recognize components of construction
Wood Structures Topic 8 Quality Workmanship
Competency: Draw wall sections and details
Elevation Layout and Drawing Techniques
PERMITS & INSPECTIONS DEPARTMENT
Floor Truss Ribbon Board Load Path
Building standards Mr. Da Silva.
© OnCourse Learning.
Presentation transcript:

PERMITS & INSPECTIONS DEPARTMENT 2003 INTERNATIONAL RESIDENTIAL CODE IRC

IMPORTANT DATES New codes will affect all plans submitted after September 1, 2005 Any existing project or plans submitted prior to September 1 will be reviewed and inspected under old codes Inspections for permits issued after September 1 will be conducted under the new codes effective November 1, 2005

IRC 2003 SECTION 100 PLAN REVIEW CERTIFICATION OF MAIN STRUCTUARAL ELEMENTS AND COMPONENTS REQUIRED FOR APPROVAL COMPLETE PLANS MUST HAVE 4 ELEVATIONS FRONT, REAR, & BOTH SIDES CROSS SECTION TO ALLOW FOR ADEQUATE DETAIL FLOOR PLANS FOR ALL LEVELS ONLY MINOR REVISIONS ALLOWED R GARAGE SLABS EXCEEDING REQUIREMENTS MUST BE ENGINEERED >2’CLEAN SAND OR GRAVEL & 6” BASE CODE SECTION DESCRIPTION

IRC 2003 SECTION 100 R105.7 BY LOCAL AMENDMENT THE PERMIT HOLDER OR HIS AGENT SHALL POST THE PERMIT INSPECTION RECORD ON THE JOB SITE IN AN ACCESSABLE AND CONSPICUOUS PLACE TO ALLOW THE BUILDING OFFICIAL TO MAKE THE REUIRED ENTRIES CODE SECTION DESCRIPTION

IRC 2003 SECTION 300 R301.5 DECK LOADS REDUCED FROM 60 PSF TO 40 PSF R303.3 BATHROOM MECHANICAL EXHAUST MINIMUM 50 CFM INTERMITENT MINIMUM 20 CFM CONTINUOUS FANS MUST BE VENTED TO EXTERIOR OF BUILDING THROUGH ROOF OR GABLE END AND TERMINATE WITH AN APPROVED CAP CODE SECTION DESCRIPTION

IRC 2003 SECTION 300 R305 MINIMUM CEILING HEIGHT FOR HABITABLE AREAS REDUCED FROM 7’6” TO 7’0” R308.4 SAFETY GLAZING WINDOWS IN & AROUND STAIRWAYS & LANDINGS WITHIN 60” OF FLOOR R309 GARAGE FIRE SEPARATION ½” DRYWALL STANDARD 5/8” TYPE X ON CEILING WITH ROOM ABOVE PLUS ½” ON ALL SUPPORTING WALLS 4” STEP DOWN IS NO LONGER REQUIRED FLOOR MUST SLOPE TOWARD DOORS OR DRAIN 20 MINUTE RATED DOOR MIN. SELF CLOSING NO LONGER REQUIRED CODE SECTION DESCRIPTION

IRC 2003 SECTION 300 R310 EMERGENCY EGRESS (BEDROOMS) WINDOWS 24” CLEAR OPENING HEIGHT 20” CLEAR OPENING WIDTH 5.7 SQ.FT. NET CLEAR OPENING IRC ADDRESSES SPECIFIC INFORMATION ON DESIGN OF WINDOW WELLS FOR EMERGENCY EGRESS CODE SECTION DESCRIPTION

IRC 2003 SECTION 300 CODE SECTION DESCRIPTION R310 EMERGENCY EGRESS (BASEMENTS) EMERGENCY EGRESS REQUIRED FROM ALL BASEMENT AREAS (FUTURE HABITABLE SPACE) BEDROOMS OR SLEEPING AREAS DOORS, STAIRWAYS, BILCO DOORS, EMERGENCY WINDOWS ARE ALL ACCEPTABLE

THIS IS NOT AN APPROVED MEANS OF EGRESS !!!

IRC 2003 SECTION 300 R311 MEANS OF EGRESS ACCESSABLE STORAGE AREAS UNDER STAIRWAYS MUST BE DRYWALLED. NO CHANGE IN STAIR REQUIREMENTS 8 1/4” MAX RISER 9” MAX TREAD R312 GUARD RAILS/ HAND RAILS MAXIMUM OPENING CHANGED FROM 6” TO 4” CODE SECTION DESCRIPTION

IRC 2003 SECTION 300 R313.1 SMOKE DETECTORS MUST BE INSTALLED ON ALL FLOORS IN ALL BEDROOMS VICINITY OF ALL SLEEPING AREAS R321.1 BUILDING ADDRESSES NOW REQUIRED 4” HIGH FOR SINGLE FAMILY 6” HIGH FOR MULTI-FAMILY MUST BE CLEARLY VISIBLE FROM STREET CODE SECTION DESCRIPTION

IRC 2003 SECTION 300 R317 DWELLING UNIT FIRE SEPARATION DUPLEX – 1 HOUR SEPARATION TOWNHOUSES (SEMI DETACHED) 2 HR SEPARATION WALL WITH PARAPET OR INSTALLATION OF FIRE-RETARDENT SHEATHING 4’ ON EITHER SIDE OF SEPARATION WALL NO OPENINGS PERMITTED WITHIN 4’ OF SEPARATION WALL NO SPRINKLER EXCEPTION CODE SECTION DESCRIPTION

IRC 2003 SECTION 400 R FROST DEPTH FOUNDATION NOT REQUIRED FOR FREE STANDING ACCESSORY STRUCTURES <= 400 SQ.FT. PERMITS ARE NO LONGER REQUIRED FOR ACCESSORY BUILDINGS UNDER 200 SQ.FT. CODE SECTION DESCRIPTION

IRC 2003 SECTION 400 R404.1 FOUNDATIONS HOUSE LOCATION SURVEY REQUIRED BEFORE FOUNDATION INSPECTION NEW TABLES BASED ON SOIL TYPE AND BACKFILL HEIGHT SPECIFIC REINFORCEMENT REQUIREMENTS CODE SECTION DESCRIPTION

IRC 2003 SECTION 400 CODE SECTION DESCRIPTION

IRC 2003 SECTION 400 R PIERS MUST BE SUPPORTED BY EARTH ON ALL SIDES IN CRAWL SPACES CANNOT BE FORMED ON TOP OF GROUND CODE SECTION DESCRIPTION

IRC 2003 SECTION 400 R406 WATER/DAMP PROOFING WATERPROOFING ONLY REQUIRED WHEN PROOF OF HIGH WATER TABLE OR SEVERE SOIL CONDITION IS SUBMITTED ENGINEERS REPORT REQUIRED BY OPTION OF BUILDER REQUEST OF INSPECTOR CODE SECTION DESCRIPTION

IRC 2003 SECTION 500 R502.8 SPANS, CUTTING, & NOTCHING BASICALLY THE SAME ONLY MINOR MODIFICATIONS TO TABLES JOIST BLOCKING OVER GIRDERS REQUIRED WHERE JOISTS DO NOT OVER LAP AT LEAST 3” EXAMPLE 12”OC TO 16”OC CODE SECTION DESCRIPTION

IRC 2003 SECTION 600 R602.3 STUD SPACING CODE SECTION DESCRIPTION

IRC 2003 SECTION 600 R STUD SPACING FOR WALLS > 10’ IRC SPECIFIES STUD SIZE & SPACING FOR WALLS GREATER THAN 10’ FOR VARIOUS LOADING SITUATIONS CODE SECTION DESCRIPTION

IRC 2003 SECTION 700 R7 WALL COVERINGS EXTERIOR BRICK VENIER SUPPORT IRC OFFERS ALTERNATIVE DESIGNS THAT IF INSTALLED PER CODE ENGINEERS DESIGN IS NOT REQUIRED CODE SECTION DESCRIPTION

IRC 2003 SECTION 800 R7 RAFTERS AND JOISTS CHANGES IN SPAN TABLES RESULTS ABOUT THE SAME ALLOWS FOR INTERPOLATION CODE SECTION DESCRIPTION

IRC 2003 SECTION 800/900 R TRUSS & WALL CONNECTIONS TRUSS CONNECTIONS REQUIRED DESIGNED TO RESIST MIN. 175 POUNDS OF LIFT R900.0ROOF ASSEMBLIES ICE PROTECTION REQUIRED FOR SLOPES < 4:12 30 LBS FELT OR EQUIVELANT CODE SECTION DESCRIPTION

IRC 2003 ENERGY CODE MARYLAND STATE ENERGY CODE As part of the International Energy Conservation Code the state of Maryland has adopted the Maryland Energy Code with no local amendments allowed. At this time Washington County does not perform energy code inspections, with the exception of verifying proper installation, flame and smoke developed index on exposed insulation, but recognizes the importance of energy conservation. R316.1 FLAME SPREAD INDEX <= 25 SMOKE-DEVELOPED INDEX <= 450 R318.1 VAPOR RETARDER SHALL BE INSTALLED ON THE WARM-IN-WINTER SIDE OF INSULATION CODE SECTION DESCRIPTION