Materials used for pipes: Sewers are made from: 1- Concrete 2- Reinforced concrete 3- Vitrified clay 4- Asbestos cement 5- Cast iron (lined with cement).

Slides:



Advertisements
Similar presentations
2.2 STRUCTURAL ELEMENT BEAM
Advertisements

Design of foundation for Fattouh building in Nablus
2.2 STRUCTURAL ELEMENT Reinforced Concrete Slabs
Reinforced Concrete Design-8
Lecture 9 - Flexure June 20, 2003 CVEN 444.
SEMINAR IN ADVANCED STRUCTURE analysis and design of box culvert
PIPE CULVERT By CH. VENKATARAMAIAH.
STATICALLY DETERMINATE STRESS SYSTEMS
Foundations and basements
ONE-WAY SLAB. ONE-WAY SLAB Introduction A slab is structural element whose thickness is small compared to its own length and width. Slabs are usually.
Presentation about Reinforced concrete
Designing for Stiffness
Consolidation Theory Examples.
BEARING OR CRUSHING Bearing Stresses (Compression Perpendicular to the Grain) Allowable stresses for compression perpendicular to the grain are available.
CM 197 Mechanics of Materials Chap 14: Stresses in Beams
ERT352 FARM STRUCTURES RETAINING WALL DESIGN
GEO-MECHANICS (CE2204) Shear Strength of Soils
EXTERNAL STABILITY The MSE wall system consists of three zones. They are: 1. The reinforced earth zone. 2. The backfill zone. 3. The foundation soil zone.
Assignment No. 1 [Grup 8] Figure below shows a portion of a hydraulic circuit. The pressure point B must be 200 psig when the volume flow rate is 60 gal/min.
MECHANICS OF MATERIALS 7th Edition
Course No: CE 4000 INVESTIGATION ON THE PERFORMANCE OF BAMBOO REINFORCED CONCRETE BEAMS Supervised By: MUHAMMAD HARUNUR RASHID Presented By: MOHAMMAD TAREQ.
1 Design and drawing of RC Structures CV61 Dr. G.S.Suresh Civil Engineering Department The National Institute of Engineering Mysore Mob:
1 Design and drawing of RC Structures CV61 Dr. G.S.Suresh Civil Engineering Department The National Institute of Engineering Mysore Mob:
1 Design and drawing of RC Structures CV61 Dr. G.S.Suresh Civil Engineering Department The National Institute of Engineering Mysore Mob:
Lec.16 Underground pipeline irrigation system - structures for underground pipelines.
University of Palestine
Scaling Three-Dimensional Figures 9-9 Warm Up Warm Up Lesson Presentation Lesson Presentation Problem of the Day Problem of the Day Lesson Quizzes Lesson.
CTC 450 Review 1  WW Characteristics. Objectives 2  Understand the basics of storm drainage systems  Understand the basics of sewer systems.
Subsurface drainage – Investigations
Stick This in Your Pipe. Information Found at the Following Website
FOOTINGS. FOOTINGS Introduction Footings are structural elements that transmit column or wall loads to the underlying soil below the structure. Footings.
Session 15 – 16 SHEET PILE STRUCTURES
Settlement Criteria  f f f for clays, silty clays, plastic silts: Chapter 5 (short term) Chapter 7 (long term, i.e., consolidation)  i i i in this.
University of Palestine
ENT 153 TUTORIAL 1.
Network Appurtenances Major operations within a water transport and distribution systems are: 1. Transmission. 2. Storage. 3. Pumping.
Chapter 13 Concrete Form Design. SLAB FORM DESIGN Method WALL AND COLUMN FORM DESIGN DESIGN OF LATERAL BRACING.
Session 19 – 20 PILE FOUNDATIONS
1.Initial setting time of cement:  40 to 60min  30 to 60min  15 to 60min  35 to 60min.
4. Properties of Materials Sediment (size) Physical States of Soil Concepts of Stress and Strain Normal and Shear Stress Additional Resistance Components.
Components of Water Networks Eng. Mona Al-Gharbawi Eng. Ayman Al-Afifi
SOIL MECHANICS AND FOUNDATION ENGINEERING-II (CE 311)
CTC 450 Review 1  WW Characteristics. Objectives 2  Understand the basics of storm drainage systems  Understand the basics of sewer systems.
PILE FOUNDATIONS UNIT IV.
The Hoover - USA. The Three Gorges - China Thrust on an immersed plane surface P5calculate the resultant thrust and overturning moment on a vertical.
Problems H.P. : 신재혁.
AR362 - Structural Systems In Architecture IV Lecture : Foundations
Sanitary Engineering Lecture 13
SOIL MECHANICS AND FOUNDATION ENGINEERING-III (CE 434)
EAS 453 Pre-stressed Concrete Design Stress Limit of Pre-stressed Concrete 1Dr. NORAZURA MUHAMAD BUNNORI (PhD), USM.
SOIL MECHANICS AND FOUNDATION ENGINEERING-II (CE 311)
Dr Badorul Hisham Abu Bakar
Sanitary Engineering Lecture 10 Revision
26 – Wastewater Conveyance System Design 2
Poisson’s Ratio For a slender bar subjected to axial loading:
Behaviour of Reinforced Concrete Beams Under Bending
FOR 5TH SEMESTER DIPLOMA IN CIVIL ENGINEERING
Structure II Course Code: ARCH 209 Dr. Aeid A. Abdulrazeg
Surface Drainage: Slope and Velocity of Overland Flow.
Warm Up Problem of the Day Lesson Presentation Lesson Quizzes.
Structure II Course Code: ARCH 209 Dr. Aeid A. Abdulrazeg.
History of Design Methodology
Reinforced Concrete Pipe
2.2 STRUCTURAL ELEMENT Reinforced Concrete Slabs
Copyright ©2014 Pearson Education, All Rights Reserved
Reinforced concrete column
Chapter 13 Concrete Form Design.
Graduation Project Bracing system for deep excavation.
Structural Design I Course Code: CIVL312 Dr. Aeid A. Abdulrazeg.
Presentation transcript:

Materials used for pipes: Sewers are made from: 1- Concrete 2- Reinforced concrete 3- Vitrified clay 4- Asbestos cement 5- Cast iron (lined with cement). 6- Ductile iron (lined with cement). 7- Steel (lined with cement). 8- PVC, UPVC 9- GRB (fiber glass). Factors effecting the selection of materials: 1- Chemical characteristics of wastewater and degree of resistance to acid, base, solvents, 2- Resistance to scour and flow (friction coefficient). 3- External forces and internal pressures. 4- Soil conditions. 5- Type of backfill 6- Useful life 7- Strength and water tightness of joints and effective control of infiltration and inflow. 8- Availability in diameter, length, and ease of installation. 9- Cast of construction and maintenance. Pipes Materials and loads

Loads on pipes When pipes are buried, many forces affect them. The following are the main forces expected to affect buried pipes:

Example (1) Calculate the backfill load on a 610 mm pipe given the following information: Backfill depth (H) = 3.6 m Trench width at the top of the pipe is 1.2 m Backfill is saturated clay, P = 1920 kg/m3 Solution H/B d = 3.6/1.2 = 3 from the figure C d =2.2 Or you can calculate C d from the equation = 6082 N/m

B. Wheel loads from trucks Wheel loads from trucks and vehicles transmit live loads to buried sewer lines. When the sewer is deep, only a small portion of the load is transmitted to the sewers. Equations to compute live loads are very complex that’s why designers pre-calculated data as illustrated by tables Table gives the highway truck loads transmitted to buried circular pipe in kN/m. The information needed are: Pipe diameter (d). Height of fill (H) above pipe (m). Note: The load is based on (71.17 kN dual-tire wheel load). If the cover fill is less than ( 1m ) the value obtained from table Should be multiplied by an impact factor obtained from next table.

Example (2) Calculate the wheel load on a 610 mm pipe that has a backfill cover of 0.8 m. Solution From the table the wheel load is kN / m (by interpolation) Since H = 0.80 m and in the range (0.61 m – 0.90 m) use table to find the impact factor of 1.1 Truck load = X 1.1 = KN/m.

C- Superficial loads on buried pipes: Superficial loads are produced by buildings and other structures crossing the trench or built along the trench. The proportion of superficial loads that reach the pipe is estimated in tables 1 and 2; the forces are divided into two types: Long superficial → Length of Application > trench Width. Short superficial → Length of Application ≤ trench Width. To find the portion of superficial load transmitted to the pipes from tables 1 and 2 one should know : a. Depth of trench b. Width of trench c. Soil type For table 2, the minimum values are for → Note: [The truck load can be also estimated as a superficial load]. [Long superficial load] [Short superficial load] L L W W Trench Structure

Table 1. Proportion of long superficial loads reaching pipe in trench Table 2. Proportion of short superficial loads reaching pipe in trench Max when L=W Min when L=<0.1 W

Example (3) A concrete structure 0.91 m wide with a weight of 1340 kg/m crosses a trench 1.22 m wide in damp clay. The structure bears on the soil 1.83 m above the top of the pipe. Find the load transmitted to the pipe. Solution The load applied by the structure is 1340X1.22= 1635 kg The pressure applied to the soil above the pipe is P= 1635/0.91= 1795 kg/m The ratio of depth to the width is 1.83/1.22= 1.5 From table 2, the maximum proportion of the load reaching the pipe will be Therefore the load reaching the pipe will be P = 1795X0.51=915 kg/m W=1.22 m L= 0.91 m Trench Structure

Strength of pipes: The crushing strength of sewer pipes is determined by the three-edge bearing test. The pipe is stressed until failure occurs. Table (3) gives the minimum crushing strength for clay pipes. Strength requirements for reinforced concrete pipes are given in table 4, for this table the crushing force correspond to 0.25mm crack. The values in the table are pre mm diameter, that’s why they are called D-Loads (KN/m.mm) The pipe strength in supporting loads depends –on the method of pipe bedding : - Class (D) bedding support the three bearing load only. - Class(C) support (1.5) the three edge load (1.5 = Load factor) - Class (B) bedding has a load factor of Class (A) bedding has a load factor of 2.3 to Other pipe material has similar tables to estimate their strength The three- edge bearing test

3 4

Example (4) A 610 mm concrete pipe is subjected to a load of 40 KN/m (backfill and wheel load). The D-load of the pipe to produce 0.25 mm crack is 38.3N/m.mm (The three edge test strength). The pipe bedding is Class A with a load factor of 3.4. a)What is the strength of this pipe b)Is the strength enough to resist the applied load if the minimum factor of safety is 1.5 c)What is the final factor of safety in this case Solution a) Strength of the pipe= the three edge test strength X bedding load factor = (38.3X610)X3.4= N/m = 79.4 KN/m b) Factored applied stress = applied stress X load factor = 40X 1.5= 60 KN/m. c) Since the strength is 79.4 KN/m > factored applied stress (60 KN/m), so the strength is enough. Factor of safety = pipe strength/ applied stress= the three edge test strength X bedding load factor/ applied stress.