SoftGOT-GOT Link function – Remote Maintenance for GOTs!

Slides:



Advertisements
Similar presentations
Modems Telemetry Products Intelligent Modems. Modems  1. What is an intelligent Modem?  2. Where can they be applied?  3. Are they easy to install?
Advertisements

What we do Larotecs Web2M is an off-the shelf, end-to-end, web-based solution designed to manage multiple widely distributed devices.
VL/WL Software Offerings
ClearCube Data Failover 3.0 Overview and Demonstration Rev
/// MELSEC Safety /// QS001CPU /// QS0J61BT12 /// QS0J65BTB2-12DT /// MELSEC Safety /// Mitsubishi Electric - MELSEC Safety - Training Documentation -
Inputs: Digital and 4 configurable for Digital or 10 bit Analog Outputs:4 - 8 amp Relays or 700ma Transistors (1 PWM) 4 Line by 18 Character fully.
CENTURION™ (C4-SERIES) Erin Cox, Market Research Analyst, Natural Gas Production Controls - Presenter Sanjay Kumar, Market Research Specialist & Product.
Programming A And Q Plc Via HMI Step 1 Set Up The HMI For Transparency.
SLC 500 COMMUNICATIONS 1.
Change | Challenge | Create © 2012 Samsung Electronics America - CONFIDENTIAL Introducing MagicInfo Lite Samsung Digital Signage.
Enhanced Vision controllers SD Cards Utilities. What can I do with an SD card? Use SD Ladder functions to: Log data to OS defined file - up to 2 millions.
KX-NS1000 Initial Set Up For step by step : 16 May,
Lesson 5 – Understanding Network Hardware. Repeaters Hubs and concentrators Bridges Routers Switches Gateways Firewalls Short-haul modems OVERVIEW.
DAKNET Presented By: rreema.
EtherNet/IP Profile Switch Step by Step
6 February LAN-50/500 Ethernet Communication.
A Quick Review of Unit 1 – Recognizing Computers Computing Fundamentals © CCI Learning Solutions.
Mitsubishi Electric – GOT1020 presentation, February 2007 /// HMI /// GT1020 /// HMI /// GT1020 /// HMI /// GT1020 /// HMI /// GT1020 /// HMI /// GT1020.
Building an Application Server for Home Network based on Android Platform Yi-hsien Liao Supervised by : Dr. Chao-huang Wei Department of Electrical Engineering.
2500 Series® HMI Panels.
P.1 Examples of Applications for the tDS-700 Dec.22, 2010.
P.1 Examples of Applications for the tGW-700 Dec.22, 2010.
eAutomation Enabler – Advantech Industrial NETworking
E900/E910 Configuration suggestions E900/E910. E900/E910 Configuration Suggestions The intention of this presentation is to provide some suggestions for.
Ethernet Data Gateway EDG Enables Information Boundary-less Over Ethernet.
Used by employees who work remotely. Diary Management Software.
Video Management Control-Bit Technologies video system manages various types of video inputs; analog or digital, originated in both analog & IP cameras,
AXIS 2460 System Overview  AXIS ETRAX 100LX  ARTPEC-1  4 MB FLASH  32 MB RAM  Up to 4 internal IDE hard disks  Linux 2.4.
Purpose Intended Audience and Presenter Contents Proposed Presentation Length Intended audience is all distributor partners and VARs Content may be customized.
Legacy Remote I/O Upgrade to Ethernet
IRRInet & ICC System Concept
UNITRONICS GPRS.
12-/24-Port Gigabit IEEE 802.3at High Power Injector Hub HPOE-1200G HPOE-2400G.
Page 1 ADAM-6000 Web-enabled Smart I/O Γιάννης Στάβαρης Technical Manager Ιούνιος 26, 2007.
Chapter 10 PLC Processors.
Page 1 - © Richard L. Goldman Mainframe Networking ©Richard L. Goldman January 7, 2002.
Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.Rev 5058-CO900E PUBLIC INFORMATION Speed Integration with Ethernet-enabled CENTERLINE® MCC,
Tellus&V-Server Data Acquisition And Remote Monitor.
E1 / T1 Series Product Introduction.
Unitronics 2009.
Repeaters and Hubs Repeaters: simplest type of connectivity devices that regenerate a digital signal Operate in Physical layer Cannot improve or correct.
AXIS 2460 Network DVR Håkan Grönte
1 Product & Technology Quality Excellence Support American Global Products Product & Technology TeSysPort Ethernet Interface for TeSys June 5, 2007.
IBM - CVUT Student Research Projects Remote Control of a Furby Toy with BlueTooth Tomáš Kunc
Otasuke GP-EX! Chapter 11 GP-Viewer EX
Panasonic Electric Works Europe AG Hotz Slide 1 Overview Screen creation software designed for the GT series.
Advancing eAutomation 2-port Ethernet to RS-232/422/485 Data Gateway ADAM-4570 Reported by Alex Hsueh IAG Web & Comm. PM
ESTeem Training Class ESTeem Serial Programming. Simple Programming Factory Defaults – Restores all commands in modem to factory defaults – FA Save –
M340 Modbus Plus Proxy Link legacy systems to Ethernet
PrefaceOtasuke GP-EX! Preface Thank you very much for purchasing our seminar textbook “Otasuke GP-EX!” (hereafter, referred to as “this textbook”).
Mitsubishi Electric – GT15 – FTP connection, July 2007 HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000 /// HMI /// GOT1000.
Copyright © 2002 Delmar Thomson Learning Chapter 10 PLC Processors.
1 © 2005 Cisco Systems, Inc. All rights reserved. 111 © 2004, Cisco Systems, Inc. All rights reserved. CNIT 221 Security 2 ver.2 Module 8 City College.
OCS Remote Viewer Release 0.12 March 21, 2007 Confidential.
Virtual Local Area Networks (VLANs) Part II
Programming Fx Plc And HMI Step 1 Set Up The HMI For Transparency.
Cscape 8.6 August 2008 Horner APG. New Workbench Features - New Model – XL6.
4000 Imaje 4020 – Software Imaje 4020 – Content ■ Content of Chapter Software: 1. Flash Up 2. Netcenter 3. FTP 4. Active X 5. XCL commands 6. Exercise.
As a distinctive management software product, DN4 platform can provide useful and convenient remote management and inquiry services. Through DN4, users.
Digital-watchdog.com Complete Megapixel Surveillance Solution DW-VP9xT4P DW-VP12xT8P DW-VP16xT8P Rev : 04/15 Presenter’s Name Title |
Run-time RAM Usage File integrity checking RecipePlus Run-time file to application file conversion Enhanced language switching New FactoryTalk View ME.
Priority PDA module overview Developed in conjunction with organisations who use field service engineers, carrying out on-site installs, repairs or maintenance.
Serial / Ethernet Converter - IE-CS-2TX-XRS232/485
ESTeem 195 Narrowband Series
What is ASEMR /ASKUE/ and the Need for Its Implementation
Reveal™ Touch Screen Product Overview
Haiwell PLC Modules Introduce
Programming Fx Plc Via HMI
Programmable Logic Controllers (PLCs) An Overview.
ETS Inside Product Launch
Presentation transcript:

GOT1000 Series SoftGOT-GOT Link Function for GT15 and GT16 series

SoftGOT-GOT Link function – Remote Maintenance for GOTs! The SoftGOT-GOT link function enables GT SoftGOT1000 to connect the GOT via Ethernet. The function synchronizes SoftGOT1000 data with GOT project data and resource data. This function is available for: (GT12 not supported yet)

Up to 99 GOTs can be monitored on a single PC System overview Interlock operations with GOT and SoftGOT ⇒ Prevent unexpected behaviors!! Up to 99 GOTs can be monitored on a single PC Worksite Office Ethernet HUB HUB Operation interlock GT15/ GT16 Data auto upload SoftGOT Serial/BUS/ Ethernet Automatically upload the project data from connected GOTs ⇒ No need to create the project data for SoftGOT!! QPLC Note! FX PLCs will be supported in one of the next development steps (no schedule yet)

Configuration (Connection Type) 1) QBUS/serial connection between GOT and PLC SoftGOT reads/writes devices in a PLC via GOT. (Ethernet Transparent Function) Worksite Office Read/write devices via GOT Ethernet GT15/GT16 SoftGOT RS232/ RS422/ QBUS QPLC

Configuration (Connection Type) 2) Ethernet connection between GOT and PLC SoftGOT reads/writes devices in a PLC by directly connecting to the PLC via Ethernet, not via GOT. Worksite Office GT15/GT16 SoftGOT RS232/ RS422/ QBUS Read/write devices by directly connecting to PLC QPLC

Data Auto Acquisition Function Features •Project data auto acquisition function SoftGOT automatically acquires GOT screen data (project data). There is no need to create the project data for SoftGOT. •Alarm data auto acquisition function SoftGOT automatically acquires the alarm data of GOT. Alarms that are already restored before connecting to SoftGOT can also be viewed. In both functions, the data stored in SoftGOT will be updated every time the SoftGOT is started up. Data Auto Acquisition Function •Operating authority Either one of SoftGOT or GOT can be operable to prevent the simultaneous operation from both sides that may cause unexpected behaviors. •Operating authority (only GOT side)  A mode to make only GOT operable. Until this mode is cancelled on a GOT, SoftGOT is not operable. Operation Interlock

Operation Interlock – Operating Authority Interlock operations with SoftGOT and GOT to prevent simultaneous operation on both sides. Worksite Office Operation interlock GT15/ GT16 SoftGOT × Not operable (without operating authority) Operable (with operating authority) QPLC Move operating authority Operation is prohibited on the GOT that had operating authority before. Obtain operating authority on the operating authority acquisition screen × Not operable (no operating authority) Operable (with operating authority)

Operation Interlock – Operating Authority Provides a mode to operate PLC only by GOT to prevent the operating authority from being moved to SoftGOT. If operating authority is enabled… Worksite Office Operation interlock GT15/ GT16 SoftGOT × Operable Not operable QPLC Not operable until GOT cancels the operating authority priority SoftGOT cannot enable/cancel the operating authority priority The operating authority can be enabled/cancelled only on the GOT side by using switches or utility functions on the GOT.

Required Hardware All GT15 models plus GT15-J71E71-100 Ethernet module All GT16 models using integrated Ethernet port Any Q CPU (only Q!)

Required Software GT Works 3 V1.10L with GT Designer 3 V1.10L SoftGOT1000 3.10L

OS Installation -> GT15/GT16 Transfer extended OS into GOT!

GT Designer 3 Project Settings Decide how to use the SoftGOT: GOT and SoftGOT should always show the same screen: Use PLC Register (D) as Screen switching device! SoftGOT should act as separate HMI showing different screens as GOT: Use GOT Register (GD) as Screen switching device!

QCPU serial or QBUS connection QCPU Ethernet connection SoftGOT settings Start SoftGOT1000 and open Communication settings QCPU serial or QBUS connection QCPU Ethernet connection

Make sure to enter the IP-address of the GOT (not the PLC!) SoftGOT settings Test GOT Link Make sure to enter the IP-address of the GOT (not the PLC!)

SoftGOT settings Start Monitor SoftGOT will work for 2h without dongle! GOT project will be uploaded to SoftGOT automatically! Monitoring will start

Good to know!

Good to know! Use internal GOT devices to control operation method effectively!

Manual references

Let’s got out to customers promoting and selling it!  This is the first time to have an Ethernet Remote Maintenance function in the GT15/GT16! Let’s got out to customers promoting and selling it! Thank you for your attention