Chemigation. Chemigation Chemigation is the process of applying pesticides and fertilizer through irrigation waterChemigation is the process of applying.

Slides:



Advertisements
Similar presentations
Inspect Water Distribution EO Air Gaps, Vacuum Breaker, and Back Flow Preventers TP 8 50 min.
Advertisements

DRIP DISPERSAL SYSTEMS Problems and Solutions Presented by Keith Surface.
Fluid Power Symbols.
Irrigation Savings: Tips for Water Conservation Melissa Baum Haley Michael D. Dukes Agricultural & Biological Engineering University of Florida.
UL/FM Fire Pump Systems Lunch & Learn 04/18/05
September 29-30, 2011 Drinking Water Program Sustained Compliance Workshop Lee Johnson, P.E
Microirrigation design Oregon NRCS Engineering Meeting January 11-14, 2005 Natural Resources Conservation Service NRCS United States Department of Agriculture.
Backflow Training Introduction to Backflow For Irrigation Systems.
Suction Pumps.
Simple Carburettor Fuel System for a Piston Engine
Turbine Protection and Control System
Proper Pump Installation Practices
State of Ohio Class A Drinking Water Operator Certification Program This course includes content developed by the Ohio Environmental Protection Agency,
HYDRAULIC DESIGN.
Select the Appropriate Pumps and Controls. © Irrigation Association Understanding Basic Pump Selection Considerations Matching the pump and system Flat.
Application Equipment and Calibration G. S. Manual - Chap. 7 Workbook - pp Application Calibration & Calculations
Injecting Chemicals into Drip Irrigation Systems Pierce’s Disease Research Symposium Flat Creek Estates May 22, 2007 Guy Fipps Professor and Extension.
Regulation of Chemigation in California: Challenges and Changes John Troiano: Mark Pepple:
Michigan Water Policy Report water use from all withdrawal – priority for withdrawals constructed prior to February Register new withdrawal constructed.
Actuators.
Installing & Maintaining Irrigation Systems Ms. Gripshover Landscaping Unit 15.
Product Introduction.
Backflow Prevention.
Equipment Methods The Basic Function of a Sprayer: Distribution & Metering Apply a dilute amount of herbicide (Rate) in a determined volume of water.
ELECTRONIC FUEL INJECTION COMPONENTS
Chemigating with Confidence Tom Hoffmann Technical Assistance Specialist Byron Fitch Chemigation Compliance Specialist Tom Hoffmann Technical Assistance.
© Irrigation Association Designing for Chemigation Equipment.
FUEL INJECTION SYSTEM OPERATION
Water Handling Operations
Fire Pump Functions The main function of a fire pump is to increase the pressure of the water that flows through it. Inadequate or nonexistent municipal.
Overlap of multiple irrigations. 3-D Uniformity Simulation.
HVAC523 Basic Subsystems.
Microirrigation Management in Grapes Mike Kizer, Extension Irrigation Specialist Mike Kizer, Extension Irrigation Specialist.
Pumps and Lift Stations. Background Fluid Moving Equipment Fluids are moved through flow systems using pumps, fans, blowers, and compressors. Such devices.
Hydraulic Symbols. Piping and Tubing Symbols Normal working line Flexible working line Pilot line Drain line Enclosure outline Direction of flow.
SESSION THREE State of Ohio Class A Drinking Water Operator Certification Program This course includes content developed by the Ohio Environmental Protection.
MECH1300 Pneumatic Power Supply Topics Compressor Types Compressor Sizing Vacuum Pumps Chapter 11.
Application Concerns for Control of Invasive Species ‘A focus on Equipment & Calibration’
NA62 – GTK Cooling Station 1 Main characteristics Fluid: C 6 F 14 (fluorocarbon) Operating temperature: -30 °C ÷ -10°C Temperature precision: ±1 K Temperature.
Specification & Installation pitfalls “Getting it right to ensure safe drinking water”
Chemigating with Confidence Class Exercise. Guidelines Work in teams Use your notes Calculate injection rate Set injection pump Work in teams Use your.
Backflow Prevention for Fire Sprinkler Systems State of Illinois Plumbing Code.
PISTON ENGINE PROPULSION Chapter 5 Fuel Systems 1933 Alvis Engine 2014 Hyundai Engine Simple Carburettor Fuel System for a Piston Engine.
Calibration of your Field Sprayers using Shortcut Methods
OILGEAR PVV PUMPS PVV 200 Performance Curves.
Cecil Tharp MSU Pesticide Education Program Pesticide Education Specialist Department of Animal and Range Montana State University.
Discover the Dosmatic Difference Trouble Shooting your Dosmatic injector for years of service.
Welcome Growers Discover the Dosmatic Difference Installing your Dosmatic injector for years of service.
Small Engines Ag  Identify basic terms and definitions associated with carburetion  List and identify individual engine parts related to carburetion.
Air Compressors Capacity Horsepower Pressure Duty Cycle.
MixRite Water Driven Injectors Training
Vertical Pump Motor Manifold Upgrade. VPMM Replaces Existing Pumps, Motors, Relief Valves, Check Valves, Discharge Filters, Pump Running Pressure Gauges,
Irrigation Management Practices Cropping A*Syst Katie L. Droscha 01/14/ /15/2013.
H & P Formulas Engineering II – August The parts and values of concern…. D 1 = diameter of cylinder (in) D 2 = diameter of piston rod (in) P 1 =
Microirrigation design Oregon NRCS Engineering Meeting January 11-14, 2005 Natural Resources Conservation Service NRCS United States Department of Agriculture.
Engineering II – August 2016
HYDRAULIC & PNEUMATIC CIRCUITS
GOVERNMENT ENGINEERING COLLEGE DAHOD
14 Refrigerant Recovery, Recycling, and Recharging.
Troubleshooting Hydraulic Pumps
Water Use & Irrigation Management
In order to design a sprinkler or drip irrigation system for the lawn, we must first know how much flow is available in gallons per minute from the water.
SB Packing Automatic Downpuller Power Unit
Fuel Supply System Service
Pumps and Lift Stations
Flow Control Valves & Pressure Relief valves
Presentation transcript:

Chemigation

Chemigation Chemigation is the process of applying pesticides and fertilizer through irrigation waterChemigation is the process of applying pesticides and fertilizer through irrigation water EPA regulations require that the water source be protected from contamination by chemical solutions in case of unscheduled system shutdownEPA regulations require that the water source be protected from contamination by chemical solutions in case of unscheduled system shutdown Only products specifically labeled for chemigation may be applied in this mannerOnly products specifically labeled for chemigation may be applied in this manner

Chemigation System Requirements Irrigation System Backflow Prevention The system must contain a functional check valve, vacuum relief valve, and low pressure drain appropriately located on the irrigation pipeline to prevent water source contamination from backflow.The system must contain a functional check valve, vacuum relief valve, and low pressure drain appropriately located on the irrigation pipeline to prevent water source contamination from backflow.

Chemigation Check Valve Check Valve Vacuum Relief Valve Inspection Port Low Pressure Drain

Backflow Prevention Public Water Systems Chemigation check valve is not adequate protection for public water systemsChemigation check valve is not adequate protection for public water systems Gooseneck pipe loop with PVBGooseneck pipe loop with PVB Reduced Pressure Zone Device (double check valve w/ low pressure drain)Reduced Pressure Zone Device (double check valve w/ low pressure drain)

Gooseneck pipe loop w/ PVB backflow preventer 2 ft min. above highest outlet Pressure Vacuum Breaker

Reduced Pressure Zone (RPZ) Backflow Preventer

Chemigation System Requirements Pesticide System Backflow Prevention The pesticide injection pipeline must contain a functional, automatic, quick- closing check valve to prevent the flow of fluid back toward the injection pump.The pesticide injection pipeline must contain a functional, automatic, quick- closing check valve to prevent the flow of fluid back toward the injection pump.

Chemigation System Requirements Pesticide Pipeline Interlock The pesticide injection pipeline must also contain a functional, normally closed, solenoid-operated valve located on the intake side of the injection pump and connected to the system interlock to prevent fluid from being withdrawn from the supply tank when the irrigation system is either automatically or manually shut down.The pesticide injection pipeline must also contain a functional, normally closed, solenoid-operated valve located on the intake side of the injection pump and connected to the system interlock to prevent fluid from being withdrawn from the supply tank when the irrigation system is either automatically or manually shut down. Pesticide injection pipeline check valve with a 10 psi minimum opening pressure is an acceptable alternative device.

Chemigation System Requirements Pesticide Injection Pump Interlock The system must contain functional interlocking controls to automatically shut off the pesticide injection pump when the water pump motor stops.The system must contain functional interlocking controls to automatically shut off the pesticide injection pump when the water pump motor stops.

Chemigation System Requirements Irrigation System Low Pressure Shutdown The irrigation line or water pump must include a functional pressure switch which will stop the water pump motor when the water pressure decreases to the point where pesticide distribution is adversely affected.The irrigation line or water pump must include a functional pressure switch which will stop the water pump motor when the water pressure decreases to the point where pesticide distribution is adversely affected.

Chemigation System Requirements Pesticide Injection Devices Systems must use a metering pump, such as a positive displacement injection pump (For example, a diaphragm pump) effectively designed and constructed of materials that are compatible with pesticides and capable of being fitted with a system interlock

Chemical Injection Pump positive displacement piston pump

Venturi Chemical Injector Bypass venturi injection device for injection of liquid chlorine, liquid fertilizer or acid. Cutaway of a venturi injector cross-section. throttling valve chemical suction port

Hydraulic Powered Chemical Injector drive water inlet & filter chemical solution intake chemical solution injection port drive water exhaust port

Chemigation System Requirements Monitoring Weather Conditions Do not apply when wind speed favors drift beyond the area intended for treatment.Do not apply when wind speed favors drift beyond the area intended for treatment.

Chemigation Safety Equipment for Engine-Driven Irrigation System

Chemigation Safety Equipment for Electric Irrigation System

Chemigation Proper system calibrationProper system calibration “The Label is the Law”“The Label is the Law” Certification is required for pesticide applicators (chemigation, conventional ground application systems, and aerial)Certification is required for pesticide applicators (chemigation, conventional ground application systems, and aerial) OSU Extension Entomologists offer applicator certification programs at several locations around the stateOSU Extension Entomologists offer applicator certification programs at several locations around the state

Chemigation Calibration Batch System A sprinkler irrigation zone covers a total area of 1.2 acres with a flow rate of 145 gpm. You want to apply a pesticide product that has a concentration of 41% ai (active ingredient). The manufacturer’s label recommends a rate of 2.5 pints ai/acre with a 0.25 inch total water application, with 0.05 inch of irrigation water applied after the product injection is complete. What chemical injection rate and injection time should be used for this product? How long should the system run after injection is complete? Application Rate, A r (in/hr): = 96.3 Q(gpm) / A(ft 2 ) = (96.3x145) / (1.2x43560) = 0.27 in/hr Total Application Time: =0.25 in / 0.27 in/hr = hr x 60 min/hr = min 

Chemigation Calibration Batch System, Continued Injection Time: 0.25 in – 0.05 in (after injection) = 0.20 in during injection time 0.20 in/0.27 in/hr = 0.74 hr x 60 min/hr = 44.4 minutes  Application amount: 2.5 pts ai/acre x 1.2 acres = 3 pts ai 3 pts ai / 0.41 ai conc. = 7.3 pts of product to be applied  Injection rate: 7.3 pts of product / 44.4 minutes = pts/min  Post-injection on-time: 0.05 inch of water applied after injection / 0.27 in/hr A r = hr hr x 60 min/hr = 11.1 min. 

Chemigation Calibration Continuously Moving System A center pivot irrigation system covers a total area of 125 acres with a flow rate of 750 gpm. The system makes a complete circuit of the field in 22 hours at the 100% speed setting. You want to apply a pesticide product that has a concentration of 36% ai (active ingredient). The manufacturer’s label recommends a rate of 1.5 pints ai/acre with a 0.50 inch total water application. What percent speed setting should be used during application? What chemical injection rate and injection time should be used for this product? Application Time, T a, for 0.50 inch depth: T a = 453 d A / Q = (453 x 0.50in x 125A / 750gpm = hr  Percent Setting, P, for hr travel time: P = 100 (T min )/ T a = 100(22hr) / 37.75hr = 58% 

Chemigation Calibration Continuously Moving System, Continued Amount of product to apply: 1.5 pts ai/A x 125 A = pts ai pts ai / 0.36 ai conc. = pts of product for 125 A  Product injection rate: pts / (37.75 hr x 60 min/hr) = 0.23 pt/minute 