Olszewski-Day 3 The Analyzer The analyzer is where the beam of ions generated in the ion source is separated into multiple beams each representing a single.

Slides:



Advertisements
Similar presentations
Ion Sources Some characteristics of ion sources (especially in high precision work): It should have high efficiency in generating ions of the element of.
Advertisements

Electron Optics.
 In our analysis of the double slit interference in Waves we assumed that both slits act as point sources.  From the previous figure we see that the.
Resident Physics Lectures
Diffraction of Light Waves
With Lenses Created by Derek J. Wells. Under the expressed written consent of Derek J. Wells in accordance with the rules and by-laws of Derek J. Wells.
Suppose that you hold the transparency in the photograph below in front of a mirror. How will its reflection appear? Is the image: (1) inverted top-to-bottom?
Chapter 31 Images.
Chapter 32 Magnetic Fields.
Chapter 23 Mirrors and Lenses.
Chapter 36 Image Formation.
Chapter 26 Geometrical Optics. Units of Chapter 26 The Reflection of Light Forming Images with a Plane Mirror Spherical Mirrors Ray Tracing and the Mirror.
Chapter 32Light: Reflection and Refraction. Electromagnetic waves can have any wavelength; we have given different names to different parts of the wavelength.
DEMONSTRATE UNDERSTANDING OF WAVES AS 2.3 LIGHT 4 WEEKS WAVES 4 WEEKS.
Chapter 23 Mirrors and Lenses. Notation for Mirrors and Lenses The object distance is the distance from the object to the mirror or lens Denoted by p.
Chapter 23 Mirrors and Lenses.
Reflection and Refraction. Reflection  Reflection occurs when light bounces off a surface.  There are two types of reflection – Specular reflection.
Light: Geometric Optics
© 2005 Pearson Prentice Hall This work is protected by United States copyright laws and is provided solely for the use of instructors in teaching their.
© 2014 Pearson Education, Inc. This work is protected by United States copyright laws and is provided solely for the use of instructors in teaching their.
IVA. Electromagnetic Waves and Optics
Copyright © 2009 Pearson Education, Inc. Chapter 32 Light: Reflection and Refraction.
Chapter 23 Mirrors and Lenses.
Copyright © 2009 Pearson Education, Inc. Lecture 8 - Magnetism.
INTRODUCTION TO INORGANIC ISOTOPE RATIO MASS SPECTROMETRY
Ultrasound – Physics & Advances
Types of Analyses Single Collector –Uses only one collector or detector –This is the case with a Daly or EM Advantages: –Need only one detector –Peaks.
Linear Momentum and Collisions
ELECTRICITY PHY1013S ELECTRIC FIELDS Gregor Leigh
© 2005 Pearson Prentice Hall This work is protected by United States copyright laws and is provided solely for the use of instructors in teaching their.
Chapter 25 Optical Instruments.
1 GEOMETRIC OPTICS I. What is GEOMTERIC OPTICS In geometric optics, LIGHT is treated as imaginary rays. How these rays interact with at the interface of.
© 2005 Pearson Prentice Hall This work is protected by United States copyright laws and is provided solely for the use of instructors in teaching their.
Copyright © 2010 Pearson Education, Inc. Lecture Outline Chapter 26 Physics, 4 th Edition James S. Walker.
Chapter 23 Mirrors and Lenses.
Transmittance Measurement Presented by Dr. Richard Young VP of Marketing & Science Optronic Laboratories, Inc.
Possible Spectrometer for eA Collider Seigo Kato Faculty of Science, Yamagata University, Yamagata , Japan Presented to the workshop "Rare-Isotope.
Chapter 13 The Characteristics of light. Objectives Identify the components of the electromagnetic spectrum. Calculate the frequency or wavelength of.
Sphere Standards and Standard Spheres Dr. Richard Young Optronic Laboratories, Inc.
Simulations of the double funnel construction for LET. Comparison with a single funnel The aim was to optimise the double funnel configuration to give.
MS Intro. MS requires gas-phase ions, why? MS uses magnetic and electric fields to control the path of a compound based on mass to charge ratio (m/z)
Wave superposition If two waves are in the same place at the same time they superpose. This means that their amplitudes add together vectorially Positively.
Physics: Principles with Applications, 6th edition
Light Reflection and Mirrors.  The Law of Reflection  When a wave traveling in two dimensions encounters a barrier, the angle of incidence is equal.
Book Reference : Pages To understand that the path of a charged particle in a magnetic field is circular 2.To equate the force due to the magnetic.
Lab 9: Geometrical optics Only 3 more labs to go!! Today we are going to do three experiments: 1. Measure the intensity of light as a function of distance.
Optics (Lecture 2) Book Chapter 34,35.
1 The law of reflection: The law of refraction: Snell’s Law Image formation.
Chapter 22 Electric Fields The Electric Field: The Electric Field is a vector field. The electric field, E, consists of a distribution of vectors,
PHY 102: Lecture Wave Fronts and Rays 9.2 Reflection of Light
Refraction and Lenses. Refraction is the bending of light as it moves from one medium to a medium with a different optical density. This bending occurs.
Part 10 Optics --Mirrors and Lenses Chapter 24 Geometric Optics.
Copyright © 2009 Pearson Education, Inc. Chapter 35-Diffraction.
Chapter 32Light: Reflection and Refraction LC Oscillations with Resistance (LRC Circuit) Any real (nonsuperconducting) circuit will have resistance.
Geometrical Optics.
Geometrical Optics.
Chapter 35-Diffraction Chapter 35 opener. Parallel coherent light from a laser, which acts as nearly a point source, illuminates these shears. Instead.
Optics: Reflection, Refraction Mirrors and Lenses
Acknowledgements Slides and animations were made by Dr. Jon Karty Mass Spectrometry Facility Indiana University, Bloomington.
Shear in Straight Members Shear Formula Shear Stresses in Beams
Chapter 32Light: Reflection and Refraction
Wave superposition If two waves are in the same place at the same time they superpose. This means that their amplitudes add together vectorially Positively.
Wave superposition If two waves are in the same place at the same time they superpose. This means that their amplitudes add together vectorially Positively.
PRESENTATION ON MEASUREMENT AND GAUGING
Compensation of Detector Solenoid with Large Crossing Angle
LEAD Tutors/Peer Instructors Needed!
Fraunhofer Diffraction
DIFFRACTION AND INTERFERENCE
Presentation transcript:

Olszewski-Day 3 The Analyzer The analyzer is where the beam of ions generated in the ion source is separated into multiple beams each representing a single charge to mass ratio (ideally). We will deal mainly with magnetic sector instruments here although we will talk briefly about other separation methods later. Remember from our discussion of ion sources that our ion beam is a roughly rectangular shaped beam that is diverging in the y–direction (beam coordinates). Divergence or convergence in the z-direction need not concern us for the moment.

Olszewski-Day 3 An ion beam that continually diverged would result in poor separation of mass. Fortunately, however, most magnetic and electric shapes have some focusing properties (just as most random pieces of glass will focus some light). Just as in the case with light some shapes are better than others. By shaping the magnetic field (I will deal mainly with magnetic separation for the moment) properly it is possible to refocus the separated ion beams and thus maximize the mass separation.

Olszewski-Day 3 Is there an ideal shape? Sort of! The shape shown below will focus a highly divergent ion beam to a perfect focus.

Olszewski-Day 3 However, there are some restrictions: It only works for mono-energetic ions with the same m/q ratio. Variations in energy will cause blurring of the focal point and different m/q values will follow different paths. It assumes the ion source is a point. If the ion source has some dimension in the y-direction (again in beam coordinates) the focal point will not longer be a point (it will be both larger and blurrier). It assumes a perfect magnet, that is, the magnetic field starts and stops abruptly at the pole faces and has a value of zero outside the magnet and a constant value inside the pole faces.

Olszewski-Day 3 Real Magnets In light of the previous restrictions and the fact that the ideal shape is not easy to machine, real magnetic sector mass spectrometers are a compromise. They usually are an approximation to some segment of the ideal shape This means that the focusing is never perfect, the ion beam focuses to a fuzzy image of the exit slit Factors that affect the size, or fuzziness, of the image: Size of the source exit slit Divergence angle Magnet geometry Miscellaneous effects

Olszewski-Day 3 Nier Geometry The Nier Geometry has been the “workhorse” of magnetic sector mass spectrometry for many years Characteristics: Magnet poles are sectors of a circle (the traditional sectors have been 60 o and 90 o ) The ion beam nominally enters and exits the magnet at 90 o Assuming an ideal magnet, the object focus (the exit slit of the source) and the image focus lie on a horizontal line that passes thru the apex of the magnet

Olszewski-Day 3 Consequences of Nier Geometry Object and image focal points lie a distance D from the magnet given by: Where R is the radius of curvature, and  is the sector angle. So for  = 90 o R= D The Nier geometry achieves first order focusing Other masses come to focus on a curved focal plane that passes through the axial focal point

Olszewski-Day 3 Nier Geometry continued Advantages of Nier Geometry Simple to machine and set up Very compact footprint especially at 90 0 Other sources of aberration can usually be ignored Disadvantages Focal plane curved, hard to set-up multiple detectors Mass separation poor at high masses especially for small magnets First order focusing limits resolution (typical beam width at focal point is 50% larger than width at source exit slit To get around some of these problems we can go to what is known as extended geometry

Olszewski-Day 3 Extended Geometry By rotating the entrance and exit pole faces of the magnet so that the entrance and exit angles are no longer 90 0 we can improve things: The focal plane becomes flat (or near flat) over a wide mass range The effective radius of curvature increases becoming twice the true radius at an angle of 26.5 o This doubles the separation between masses and doubles the distance of the focal points from the magnet Most importantly we achieve second order focusing, the beam width increasing by about 15%

Olszewski-Day 3 Advantages of Extended geometry: 1.Focal plane is relatively flat, multiple detectors easier to use 2.Twice the mass separation for the same size Nier magnet 3.Second order focusing improves mass resolution Disadvantages: 1.Footprint larger 2.Focal plane at an angle to the incoming beams, detectors must be staggered “en echelon” 3.Other aberrations must be considered Disadvantage 2 can be gotten around, that is the focal plane can be made to intersect the beams at a right angle (for the axial beam)

Olszewski-Day 3 Extended Geometry as practiced by GV and precursors By shaping the pole faces and making the exit face angle adjustable it is possible to bring the focal plane at right angles to the axial beam:

Olszewski-Day 3 The Z-direction and Fringe Fields If there is no z-focusing in the ion lens the ions diverge in the z-direction The flight tube internal dimension at the magnet pole gap determines the beam’s z dimension and divergence

Olszewski-Day 3 Z-focusing With Z-focusing lenses we can confine the beam to the pole gap However, Z-focusing is complicated by fringe fields and other factors

Olszewski-Day 3 Fringe Fields The magnetic field of the magnet extends outside of the pole face: Characteristics of fringe field: Strongly curved outside of magnet and just inside pole face Lower field just inside pole face Strength depends on magnetic properties Of magnet material and pole gap

Olszewski-Day 3 Effects of Fringe field In Nier magnet the fringe field moves the focal points and adds aberrations from a z component to the magnetic force –These aberrations can be mitigated somewhat by z-focusing In extended geometry the fringe field can be used to focus in the z-direction especially when combined with z-focusing lenses Still produces small amount of aberration

Olszewski-Day 3 Dispersion is the actual physical distance between the focal points of two adjacent masses at the focal plane. Where d is the dispersion. Dispersion

Olszewski-Day 3 Dispersion continued For a symmetrical mass spectrometer (i.e., where object and image distances are the same) there is a relatively simple equation to calculate dispersion: where R eff is the effective radius of curvature of the magnet (for a Nier magnet this is the actual radius of curvature, for extended geometry it is twice the real radius), m is the axial mass and  m is the difference in mass. Note this equation is a simplification of a more complex equation and is not exact for a number of reasons but is very close as long as  m is not too large.

Olszewski-Day 3 Dispersion For example, an extended geometry magnet with an R eff of 540 mm has a dispersion at mass 88 of mm per amu but only mm per amu at mass 238. These would be one half these numbers for a Nier magnet. Dispersion is also sometimes given as ppm of the effective radius, i.e.: For the examples above: At mass 88 the dispersion is ppm. At mass 238 the dispersion is 4202 ppm. Note that the dispersion is independent of the magnet angle and ion energy. This equation can also be used for calculating any physical distance at the focal plane or converting a distance to mass equivalent. We will see more of this when we discuss resolution.

Olszewski-Day 3 At the focal plane Beams are isolated at focal plane by slits Slits must be wider than beam width at focal plane to allow total beam to reach detector and also to allow for variations in magnetic field and ion energy (Flat Topped Peaks) The ability to resolve two closely spaced peaks depends on the dispersion, the beam width at the focal plane and the collector slit width

Olszewski-Day 3 Cross Section of Beam Intensity at the Focal Plane These are cross sections through the beam at the focal plane along the medial plane First Order Focusing Second Order Focusing Ideal Focusing

Olszewski-Day 3 What do we see at the detector? Observed peak is wider than beam Peak top is flat (intensity does not change) while beam is in slit Intensity of Peak is the beam integrated over its whole width Collector Slit

Olszewski-Day 3 Calculating beam parameters Beam WBWB Slit WSWS Observed Peak WPWP WTWT

Olszewski-Day 3 Some Examples For W B = 0.35 mm and W S = 1.0 mm –W T = 0.65 mm and W P = 1.35 mm Note that these values are mass independent However, in terms of amu these values will vary depending on the mass we are looking at: –At mass 88 W B = amu, W S = amu, W T = amu and W P = amu –At mass 208 W B = amu, W S = amu, W T = amu and W P = amu W P represents the minimum spacing between two peak before they overlap at the baseline level, W P / 2 represents the spacing at which two peaks overlap at peak top center We can now look at mass spectrometer resolution

Olszewski-Day 3 Resolution Resolution is a measure of the ability to distinguish two closely spaced ion beams. Resolution is usually defined as: where R is the resolution, m is the mass whose resolution is being measured and  m 10% is the mass change necessary to get the peak intensity down to 10% of its maximum intensity.

Olszewski-Day 3 Resolution continued The mass at 10% intensity can be hard to calculate, it is sometimes more useful to use the baseline width calculated above: –For Sr: 88/0.11 = 800 –For Pb: 208/0.260 = 800 Notice that this is also the radius of curvature (effective) divided by one-half the peak width (W P ) So for example at mass 208 we could have two peaks separated by amu and still measure the correct beam intensity (just barely) if we centered on the peak top of each peak However, in mass spectrometers with multiple detectors the limiting factor is usually how close we can get the detectors to one another.

Olszewski-Day 3 Even with perfect focusing we would find a widening of the beam width at the focal plane, especially on the low mass side of the beam This is because of interactions between the ion beam and residual air in the mass spectrometer We can distinguish two end member types of interaction (with most interactions falling in between): Head-On Collision: Glancing Collision: Abundance Sensitivity AIR + +

Olszewski-Day 3 Head-On Collisions Direction of motion of ion changed little, some energy is lost by the ion however If this occurs after the ion has passed through the magnet, No Problem If it occurs before or during passage through the magnet the path of the ion will be different from the ions of the same mass that have not lost energy. The effect is greatest when the energy loss is high or if the loss occurs early in the flight path. Energy loss causes the ion to behave like a slightly less massive ion, so it will reach the focal plane at a mass position slightly lower than its true mass This produces a tail on the low mass side of an ion beam which for intense ion beams can be significant evens a few amu away. This makes it difficult to measure a very small beam on the low mass side of a very intense beam For example: 234 U next to 235 U, 236 U and 237 U next to 238 U 230 Th next to 232 Th

Olszewski-Day 3 Glancing Collisions Ion loses little energy but its direction of travel can change significantly The effect is greatest if it occurs early in the flight path Changes in direction are symmetric The result is to produce tails on both the high and low mass sides of the beam, or alternatively to widen the base of the beam Abundance Sensitivity Abundance sensitivity is a measure of the extent of this effect and is defined as: Where A = abundance sensitivity in ppm, I M-1 is the intensity 1 amu below the main peak at mass M and I M is the intensity of the main peak

Olszewski-Day 3 Abundance Sensitivity Depends on the quality of the vacuum in the mass spectrometer For machines like the Sector 54, Isolab or Triton with only a magnetic sector at a pressure of torr the typical abundance sensitivities are 1 to 10 ppm This means that isotope ratios lower than a few times would be difficult to measure It is difficult to get vacuums much below torr with machines this size (and for other reasons) So how can we improve abundance sensitivity?

Olszewski-Day 3 Improving Abundance Sensitivity In lieu of a perfect vacuum there are ways to improve abundance sensitivity Add an electrostatic filter: Magnet Source Electrostatic Filter Works reasonably well, usually gives a factor of 10 or so improvement in Abundance sensitivity Disadvantages: Bends beam Still lets through range of energies Does little to remove glancing collision particles

Olszewski-Day 3 Improving Abundance Sensitivity continued WARP, RPQ filters Both use an aperture to pass only ions that have lost less than a certain amount of energy: A quadrupole or long aperture is used to remove ions entering at high angle (the glancing collisions) V +8KeV ion V Ion