System Characteristics. Recap SYSTEM CHARACTERISTICS.

Slides:



Advertisements
Similar presentations
It is very difficult to measure the small change in volume of the mercury. If the mercury had the shape of a sphere, the change in diameter would be very.
Advertisements

Instructor: Lichuan Gui
Chapter 1. Basic Concepts of Medical Instrumentation Walter H. Olson
Dept. Of Medical Equipment Huriamila Community College King Saud University 1428 / 1429 Introduction to Medical Equipment (MED 201)
Characteristics of Instruments P M V Subbarao Professor Mechanical Engineering Department A Step Towards Design of Instruments….
Chapter 1 Measurement Systems. Table 1.1 Biomedical engineers work in a variety of fields. Bioinstrumentation Biomaterials Biomechanics Biosignals Biosystems.
Selection of measuring instruments
1 Fourth Lecture Static Characteristics of Measurement Systems (continued) Instrumentation and Product Testing.
Part 1: Basic Principle of Measurements
Presented by- Md. Bashir Uddin Roll: Dept. of BME KUET, Khulna-9203.
Chapter 1. Basic Concepts of Medical Instrumentation Walter H. Olson
bioMEDical Instrumentation system
bioMEDical Instrumentation system
Chapter One Characteristics of Instrumentation بسم الله الرحمن الرحيم.
Classification of Instruments :
Instrumentation and Measurements
V. Rouillard  Introduction to measurement and statistical analysis ASSESSING EXPERIMENTAL DATA : ERRORS Remember: no measurement is perfect – errors.
Basics of Measurement and Instrumentation
SENSORS MEETING THE NEEDS OF THE DAY  A device which converts energy or information in one form to another  In other words, a device which provides.
INTRODUCTION TO MEASUREMENT
1 Passive components and circuits - CCP Lecture 4.
Performance characteristics for measurement and instrumentation system
Part 1: Basic Principle of Measurements
LECTURER PROF.Dr. DEMIR BAYKA AUTOMOTIVE ENGINEERING LABORATORY I.
INTRODUCTION MEASUREMENT STANDARDS AND UNITS.
EKT 451/4 SEM 2 Chapter 6 SENSOR & TRANSDUCER SHAIFUL NIZAM MOHYAR
Biomedical Electrodes, Sensors, and Transducers
Instrumentation and Measurements Class 3 Instrument Performance Characteristics.
MEASUREMENT STANDARDS AND UNITS. Chapter Objectives Contents  To define some measurement terms  To describe basic measurement units and relate to derivative.
MEASUREMENT AND INSTRUMENTATION
Lecture I Sensors.
INSTRUMENTATION Introduction to Instrumentation Syarifah Norfaezah
Module 1: Measurements & Error Analysis Measurement usually takes one of the following forms especially in industries: Physical dimension of an object.
Perceptible output Output display Control And feedback Signal
BME 353 – BIOMEDICAL MEASUREMENTS AND INSTRUMENTATION MEASUREMENT PRINCIPLES.
Measurements Measurements and errors : - Here, the goal is to have some understanding of the operation and behavior of electrical test instruments. Also,
EMT 462 ELECTRICAL SYSTEM TECHNOLOGY Part 2: Instrumentation By: En. Muhammad Mahyiddin Ramli.
Definition of a sensor Def. 1. (Oxford dictionary)
1 5. SOURCES OF ERRORS Disturbances: interference noise 5.6. Disturbances: interference noise Measurement errors can occur due to the undesirable.
Transducers.
1 Chapter 01 Measurement And Error. 2 Summary Instrument – a device or mechanism used to determine the present value of a quantity Measurement – a process.
EKT 314/4 WEEK 2 : CHAPTER 1 INTRODUCTION TO EI ELECTRONIC INSTRUMENTATION.
Biomedical Instruments Design 475 BMIS. Medical Instrumentation Design of instrument must match Measurement needs (environmental conditions, safety, reliability,
Instrument Characteristics  Scientific Instrument: l A device for making a measurement.  Measurement: l An action intended to assign a number as the.
Biomedical Instruments Design
EKT 451 CHAPTER 6 Sensor & Transducers.
1 Transducers EKT 451 CHAPTER 6. 2 Definition of a Transducers   Transducer is any device that converts energy in one form to energy in another.  
Electric Pressure Transducer
Introduction to Sensors and Actuators
Instrumentation & Measurement
TRANSDUCERS PRESENTATION BY: Dr.Mohammed Abdulrazzaq
Biomedical Instruments Design Biopotential Amplifiers
MECH 373 Instrumentation and Measurement
Performance characteristics
M&M/ UNIT- 1 Error types,control,standards/ K.Ragunath, AP/Mech
Lecture 1 Technological Principles of Medical Instrumentation
Lecture 4 Technological Principles of Medical Instrumentation
Technological Principles of Medical Instrumentation
Technological Principles of Medical Instrumentation
Characteristics of measurement systems
INSTRUMENTASI INDUSTRI
BASICS OF MEASUREMENT AND INSTRUMENTATION
Introduction to Instrumentation Engineering
Mechanical Measurements and Metrology
Measurements Measurements and errors :
Biomedical Instruments Design Biopotential Amplifiers 1.
Measurements & Error Analysis
Measurements and Instrumentation
Basic Steps in Development of Instruments
EC 217 MEASUREMENTS AND INSTRUMENTATION
Presentation transcript:

System Characteristics

Recap

SYSTEM CHARACTERISTICS

Medical Measurement Constraints The amplitude and frequency ranges for each parameter are the major factors that affect the design of all instrument components Proper measurand-sensor interface cannot be obtained Medical variables are seldom deterministic External energy must be minimized to avoid any damage Nearly all biomedical measurements depend on some form of energy being applied to the living tissue or to the sensor, for example: X-ray, ultrasonic imaging and electromagnetic or Doppler ultrasonic Blood flow-meters depend on externally applied energy interacting with living tissue Safe level of applied energy is an important consideration Equipment must be reliable

Additional Medical Measurement Constraints Reliable Simple to operate Withstand physical abuse and exposure to corrosive chemicals Electrical safety (minimize electric shock hazard)

Classification of Biomedical Instruments Quantity being sensed: Pressure, flow, temperature, potential, etc. Advantage: easy comparison of different methods for measuring any quantity Principle of transduction: Resistive, capacitive, inductive, ultrasonic or electrochemical Advantages: a. different applications of each principle can be used to strengthen understanding of each concept b. newer applications readily apparent Measurement technique for each physiological system: Cardiovascular, pulmonary, nervous, endocrine Advantage: isolates all important measurements for specialists Disadvantage: considerable overlap of quantities sensed and the principles of transduction used

Classification of Biomedical Instruments... Clinical medicine specialties: Pediatrics, Obstetrics, Cardiology, Radiology, etc. Advantage: valuable for medical personnel interested in specialized instruments

Interfering and Modifying Inputs Desired input: the measurand that the instrument is designed to isolate and measure Interfering inputs: quantities that inadvertently affect the instrument as a consequence of the principles used to acquire & process the desired inputs Modifying inputs: undesired quantities that indirectly affect the output by altering the performance of the instrument itself Modifying inputs can affect processing of either desired or interfering inputs Some undesirable quantities can act as both a modifying input and an interfering input

Example  A simplified ECG recording system provides a good example: In this recording system: The desired input is: V ecg – electrocardiographic voltage between 2 electrodes (RA & LA) The interfering inputs are: 50 Hz or 60 Hz (power-line) noise voltage induced in the shaded loop by ac magnetic fields Also the difference between the currents running through each of the electrodes to the patient and to the ground causes a voltage on Z body

Example... In ECG, the example of a modifying input is the orientation of the patient cables. If the plane of the cable is parallel to the ac magnetic field, magnetically introduced interference is zero. If the plane of the cables is perpendicular to the ac magnetic field, magnetically introduced interference is maximal. Time–dependent changes in electrode impedance Electrode motion

Elimination of Interfering and Modifying Inputs  To reduce or eliminate the effects of most interfering and modifying inputs we have two alternatives:  1. Alter the design of essential instrument components (preferred, but hard to achieve)  2. Add new components to offset the undesired inputs

Compensation Methods 4 Types  1. Inherent sensitivity All components only respond to desired inputs: make G i and G m,d = 0 In the ECG recording problem, Figure 1.3 of Webster: twist the electrode wires: this makes G i →0 (remember from Physics: v in ~B (magnetic field density). A (area subtended by the mag. Field). N (number of wire turns) By twisting the wires we make A→0! Therefore v int = 0! Minimize electrode motion → this makes G m,d →0  2. Negative feedback – when the modifying input can not be removed or avoided, we should – minimize the effects of the transfer function of the instrument system on the output.

Compensation... Filtering: For example a notch filter can remove the 60Hz component of the inputs signal. A filter is a device or program that separates data or signals based on a specific criteria. Filtering is an extensive topic. Opposing inputs: Make an additional input that opposes the unwanted input. Example: We can use thermistors (temperature dependent resistors) to counteract the unavoidable temperature-dependent changes in the characteristics of the active elements of the circuits.

Sensor characteristics Static characteristics The properties of the system after all transient effects have settled to their final or steady state Accuracy, Discrimination, Precision, Errors, Drift, Sensitivity, Linearity, Hysteresis (backslash) Dynamic characteristics The properties of the system transient response to an input Zero order systems First order systems Second order systems

Accuracy & discrimination Accuracy is the capacity of a measuring instrument to give RESULTS close to the TRUE VALUE of the measured quantity Accuracy is related to the bias of a set of measurements (IN)Accuracy is measured by the absolute and relative errors More about errors in a later Discrimination is the minimal change of the input necessary to produce a detectable change at the output Discrimination is also known as RESOLUTION When the increment is from zero, it is called THRESHOLD

Precision The capacity of a measuring instrument to give the same reading when repetitively measuring the same quantity under the same prescribed conditions Precision implies agreement between successive readings, NOT closeness to the true value Precision is related to the variance of a set of measurements Precision is a necessary but not sufficient condition for accuracy Two terms closely related to precision Repeatability The precision of a set of measurements taken over a short time interval Reproducibility The precision of a set of measurements BUT taken over a long time interval or Performed by different operators or with different instruments or in different laboratories

Example Shooting darts Discrimination The size of the hole produced by a dart Which shooter is more accurate? Which shooter is more precise? Shooter A Shooter B

Accuracy and Errors Systematic errors Result from a variety of factors Interfering or modifying variables (i.e., temperature) Drift (i.e., changes in chemical structure or mechanical stresses) The measurement process changes the measurand (i.e., loading errors) The transmission process changes the signal (i.e., attenuation) Human observers (i.e., parallax errors) Systematic errors can be corrected with COMPENSATION methods (i.e. feedback, filtering) Random errors Also called NOISE: a signal that carries no information True random errors (white noise) follow a Gaussian distribution Sources of randomness: Repeatability of the measurand itself (i.e., height of a rough surface) Environmental noise (i.e., background noise picked by a microphone) Transmission noise (i.e., 60Hz hum) Signal to noise ratio (SNR) should be >>1 With knowledge of the signal characteristics it may be possible to interpret a signal with a low SNR (i.e., understanding speech in a loud environment)

Example: systematic and random errors

More static characteristics Input range The maximum and minimum value of the physical variable that can be measured (i.e., - 40F/100F in a thermometer) Output range can be defined similarly Sensitivity The slope of the calibration curve y=f(x) An ideal sensor will have a large and constant sensitivity Sensitivity-related errors: saturation and “dead-bands” Linearity The closeness of the calibration curve to a specified straight line (i.e., theoretical behavior, least-squares fit) Monotonicity A monotonic curve is one in which the dependent variable always increases or decreases as the independent variable increases Hysteresis The difference between two output values that correspond to the same input depending on the trajectory followed by the sensor (i.e., magnetization in ferromagnetic materials) Backslash: hysteresis caused by looseness in a mechanical joint