KENTAMED Radio B is a cutting-edge technology 4MHz radiofrequency surgery unit. It combines the well-known tissue spearing effects of the radiofrequency.

Slides:



Advertisements
Similar presentations
Effect of Electricity on Living Tissue
Advertisements

INTRODUCTION APPLICATION IN THE DRIVING SEAT THE DOCTOR WILL SEE WIRED WEARABLES DO NOT KEEP YOUR EYES ON ROAD ADAPTIVE CRUISE CONTROL(A.C.C.) WORKING.
New! KENTAMED RF-B 4MHz surgery 4 MHz radiofrequency surgery
Compression 1. Effects of External Compression Improved Venous and Lymphatic Circulation Limits the Shape and Size of Tissue 2.
Surgical Diathermy Machine
Kenny Low Dec 2009 Urology registrar Thursday teaching
EE 4BD4 Lecture 25 Electrosurgery Biomedical Device Technology: Principles and Design, Charles C. Thomas Publisher 2007 Anthony K. Chan 1.
Shortwave and Microwave Diathermy part(2). Induction Electrodes (Drum Electrode) One Or More Monopolar Coils Rigidly Fixed In A Housing Unit May Use More.
T. E. Potok - University of Tennessee Software Engineering Dr. Thomas E. Potok Adjunct Professor UT Research Staff Member ORNL.
1 Engine Protector Safe Rider Vehicle Technologies (Pty) Ltd PO Box 11376, Rynfield South Africa Tel./ fax Cell:
Page 1 of 28 Modular Instruments for Suction and Irrigation Versatile and Precise Presentation Suction- and Irrigation Systems presents:
Solar Home UPS 850VA & 1400VA India’s first Sine wave inverter with in built Solar Charge Controller and Controlled DC Load Output. Simultaneous Charging.
Minimally Invasive Surgical Techniques and Instruments David Ramsay.
This presentation may contain some forward looking statements, particularly regarding operational prospects in 2008 and beyond, which involve a number.
MULTI-FREQUENCY MICROWAVE GENERATOR CONTROLLED BY COMPUTER AND HAVING COMPLEX CHARACTERISTICS OF TIME AND AMPLITUDE FOR EXAMINATION OF CHAOS IN ELECTRONIC.
Model Continuous Workstation Monitor, Dual Wire ©Copyright 2003 DESCO INDUSTRIES INC.
Fastener Division Proprietary and Confidential Plastic Staple® ST9500 TM Patents Pending Plastic Staple ® ST9500 TM System Overview
Access Business Development Division ThyssenKrupp A Division of ThyssenKrupp Access Ltd Flow 2 Introduction.
What is electrosurgery?
Diathermy.
Without reference, identify principles about Electrosurgical Units with at least 70 percent accuracy.
PME100 - height limiter with optional 2D dig depth capability SPECIFICATION SHEET Functions: Suitable for: ////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////
NAVIGATOR™ Portable Balances
◦ What is an Operating System? What is an Operating System? ◦ Operating System Objectives Operating System Objectives ◦ Services Provided by the Operating.
Copyright Silca S.p.A Marker Copyright Silca S.p.A MARKER 2000: Electronic micro-point marking machine for keys and cylinders Marker.
TRS series Vegetable Slicers USA range. TRS Vegetable Slicer Models 1-Speed 400 rpm 370 W/500 W/750 W 2-Speed 400/800 rpm 750 W Multi-purpose vegetable.
Shortwave and Microwave Diathermy
F. 1 Design and Technology
LESSON 8 CONTROLLING BLEEDING 8-1.
BASICS OF ELECTROSURGERY
Motor-driven pumps  Sigma/ 1  Sigma/ 2  Sigma/ 3.
Electrosurgery & Gyn Surgery: Get the Point Across
COPYRIGHT SILCA SpA 2007 Bravo ProfessionalSilca S.p.A. Bravo Professional.
Nuclear Magnetic resonance (NMR). Nuclear Magnetic Resonance NMR works by getting hydrogen nuclei in the body to emit radio waves. Analysis of this radiation.
Computer controlled I NSTANT R ESPONSE ™ system provides safer and more precise electrosurgery. TM.
Electro-acupuncture Lecturer:Qu Hongyan Teaching objects 1 . Concept and characteristics of electro- acupuncture; 1 . Concept and characteristics of.
The Epidermis Skin Pigments – Nevi (“birthmarks” or moles) are chronic lesions of the skin – they are, by definition, benign. – Malignant melanoma is a.
Argon Enhanced Electrosurgery. Characteristics of argon gas (helium, neon, freon etc. also possible, but.....) inertnon-explosive heavier than air not.
3.1.1 – The demands of performance – aerobic and anaerobic exercise Learning objectives To describe the difference between aerobic and anaerobic respiration.
MATRIX series.
YXLON YXLON International is an innovative High-Tech company, rich in great traditions. Founded in spring 1998, YXLON International is the direct successor.
The Electromagnetic Spectrum & Properties of Waves Sections 10.4 and 10.5.
Electro surg i cal unit  PURPOSE ESU are used for surgical cutting and for controlling bleeding by causing coagulation “ hemostasis ” at the surgical.
Wireless TL70 Sure Cross ® Wireless TL70 Tower Lights combine the best of Banner’s popular Tower Light family with the reliable, field-proven, Sure Cross.
Need Statement and Need Criteria. Need Statement To prevent the reoccurrence of stenosis in coronary arteries. More specifically, to create a solution.
This presentation may contain some forward looking statements, particularly regarding operational prospects in 2009 and beyond, which involve a number.
Shortwave Diathermy Clinical Application. Treatment Dosages Pulse DoseSensationWidthRate (pps) NTNo warmth65 µsec100 – 200 1Mild warmth100 µsec800 2Moderate.
Electrosurgical Unit.
RadioFrequency In Arthroscopy By Chuckie Slater. RadioFrequency ●The use of Plasma heat generated from a probe's electrodes to ablate(remove) tissue or.
 There are three main types of blood vessels in the mammalian circulatory sys: 1. Arteries (smaller ones are called arterioles) 2. Veins (smaller ones.
Front loaders boasting top performance Cold milling machines W 100 F, W 120 F, W 130 F.
Solar Power Charge Controller. Solar Power Charge Controller Introduction  A charge controller, or charge regulator is basically.
Facelift Surgery Procedure in Hyderabad
SAFE USE OF DIATHERMY RACHEAL AFOLABI, RN, RM, H. Dip. PERI-OPERATIVE NURSING, H.Dip. HEALTH SYSTEM MANAGEMENT.
(Formally Kormara Midi)
Microwave diathermy.
National Highway Institute 5-1 REV-2, JAN 2006 EQUIPMENT FACTORS AFFECTING INERTIAL PROFILER MEASUREMENTS BLOCK 5.
Shahzad Pirzada and Genadyne Biotechnologies Inc. have the solution for your long-term and home-based pressure ulcer care.
TouchView™ Ultrasound Imaging System Combining Vision with Insight.
DIATHERMY Diathermy was once one of the most popular modalities used in rehab. Became less popular with development of more modern tech like US and because.
Electro surgical unit.
automatic recognition of load-type superior functionality
Acti-Lance Safety Lancet
Where You can Go For Get Infini Acne Scars Removal.
SURGICAL DIATHERMY.
SURGICAL DIATHERMY.
Diathermy and its safe use
Welcome to Jeopardy!.
Fundamental Use of Surgical Energy
Presentation transcript:

KENTAMED Radio B is a cutting-edge technology 4MHz radiofrequency surgery unit. It combines the well-known tissue spearing effects of the radiofrequency with revolutionary innovations of the wave form characteristics. KENTAMED Radio B has an extremely wide spectrum of clinical applications and it guarantees quick tissue healing and patient recovery.. The output power is sufficient for veterinary surgery KENTAMED Radio B 4MHz surgery 4 MHz radiofrequency surgery 90 Watts maximal output power Soft and Forced coagulation modes Fine and Heavy Cutting modes Bipolar coagulation mode Finger switch and foot switch activation High level of patient safety New!

Modes of operation: Fine cutting – For fine and gentle cuts with minimal necrosis, which helps quick healing. This mode is also suitable for skin incisions when using needle type electrodes. The maximum output power is 80 Watts. Heavy Cutting – For deep cuts through muscle, fat and fibrosis. Even though yellow light may be visible around the active electrode, the carbonization on both size of the cut is minimal due the radio frequency. The maximum output power is 90 Watts. Soft Coagulation – Also called “white coagulation”. It results in a while elastic coagulation cap that prevents recurrent bleeding over a long period of time after surgery. The maximum output power is 75 Watts. Forced Coagulation – This is a powerful sparking coagulation that results in a carbonized coagulation cap (crust). It is very effective for rapid coagulation of capillary bleeding. The maximum output power is 45 watts. Bipolar Coagulation – Soft and powerful coagulation, capable of vessel sealing. It can seal blood vessels wit diameter of 3-4 mm. This mode also has sub-mode called “Micro”. This allows the user to have in the memory two different settings for the preset output power. The maximum output power is 75 Watts (30 Watts in Micro mode). User friendly and intuitive interface: KENTAMED Radio B is an extremely easy to use machine. Every mode can be selected with only one touch. The settings of each mode are stored independently and they are kept even when the unit is switched off. The output power can be adjusted with precision of 1 Watt and the indicators show the actual setting in Watts (not percentage).

Great variety of accessories: KENTAMED Radio B comes with many different accessories in correspondence with the versatile functionality of the unit. These accessories cover a spectrum of clinical procedures, performed in either monopolar or bipolar modes. KENTAMED Ltd. constantly adds new types of electrodes to its product list. Manufacturer: KENTAMED Ltd., 43 Nestor Abadjiev Str., POB 203, Plovdiv 4023, Bulgaria tel/fax: ; mobile: ; Distributor: Safe for the patient and the personnel: KENTAMED Radio B has several features like the Neutral electrode monitoring system (NEMSY), the Output power failure detection system, etc. that ensure patient’s and personnel’s safety of highest standards. The software tracks the actions of the user and prevents any harmful activities. The unit also protects itself against overheating.