Introduction to Truck 3 Pierce 105’ Aerial

Slides:



Advertisements
Similar presentations
Montgomery County Fire Rescue Medical Ambulance Bus 20 Patient Capacity.
Advertisements

General Safety Overview and Information
Kawasaki Mule Trans 4X4.
Dennis Fire Appliances Operations & use. PTO Step 1 Move slide cover towards the drivers seat to lock out the gearbox Step 2 Select drive on the gear.
What Goes Up… Must Come Down Portable Ladder Safety
Bungay Fire Brigade Tanker Rosenbauer Tanker on a Internationsl chassis. 2,500 gallons of water with a 1,000 GPM midship pump 1,000’ LDH.
Stanley HP-1 Compact Power Unit.
Morgan City Rentals Diesel Jet Pump 6 x 6 Peerless Safe Operating Practices and Procedures.
Basic Vehicle Control Chapter 3.
The Truckee Meadows Fire Protection District Presents.
Motorized Tongue Jack Owners Manual Model SAFETY WARNINGS * Read, understand and follow all instructions before installing and/or using product.
E – gpm Pump / 500 gallon Tank / 1,000’ 5” Hose.
Aerial Apparatus Operator
CAFS On-Line Orientation
ET ,000 Gallons of Water GPM Pump.
DAILY PRE-TRIP.
STOKES BASKET SOG /08 PIERCE TRACTOR DRAWN AERIALS
Blackwood Fire Company
Driver Recert 2013 Topics Review of Water Supply SOG’s MAWW Main St. Tank OOS BlitzFire Deployment with Water Thief Tower Operations Foam System Review.
Water supply and drafting. Objectives Understand and be able to demonstrate the different hydrant lays and hook ups Explain/demonstrate how to operate.
Aerial Familiarization
Driver Recert 2012 Topics Update on Fire Hose Friction Loss Coefficients Fire Flow Through Long LDH Supply Lines Rural Water Supply Flow Rates Booster.
AO-AD Unit 41 NYS Department of State Office of Fire Prevention & Control APPARATUS OPERATOR AERIAL DEVICE Outreach Training Course 79.
LoneStar Fire Specialties
1B-1 Fire Engine Maintenance Unit 1B – Pump Inspections and Maintenance.
Pumping Apparatus Driver/Operator
Categories of Aerial Ladders Aerial Ladders Aerial Platforms Telescoping Aerial Platform Tele-Squirt Articulating Aerial Platform Quint.
1A-1 Fire Engine Maintenance Unit 1A Vehicle Inspections.
Fire Apparatus Familiarization
Bothell Fire and E.M.S. INTRO TO PUMP OPERATIONS Written and Produced by Jon Troglia Jon Troglia Bothell Fire and EMS.
C L A S #4 Driver Operator Refresher Training.
Aerial Apparatus Operator Types and Construction of Aerial Apparatus.
Types of Fire Apparatus
Fire vs. Water Flow. What’s the best size for an “attack line?”  Maximum flow  Maximum mobility  Speed-How fast and how much  Ease of deployment and.
C L A S #2 Driver Operator Refresher Training. Operating Emergency Vehicles Class #2 Henderson Fire Department Defensive Driver Refresher Training.
Fire Pump Functions The main function of a fire pump is to increase the pressure of the water that flows through it. Inadequate or nonexistent municipal.
Instructor Lee Lautzenheiser
C L A S #5 Driver Operator Refresher Training.
APPROVED TRAINING MANUAL’S LESSON PLANS AND COURSEWARE STAR MARIANAS AIR, INC. Recurrent – Flight Crew Part III – Aircraft Ground Training Section 2 –
EZ Reach 40 Training & Procedure Manual. Unit Capacity One of the most important considerations when operating this machine is the Bucket Capacity of.
FAMA Technical Committee FDIC FAMA Technical Committee FDIC ‘08 Carl E. Peterson, Director NFPA Public Fire Protection Division
Water Supply Skill Drills.
Water Supply. Basics: Such as standing BEHIND the hydrant when you open it can save your life!
Pumps and Lift Stations. Background Fluid Moving Equipment Fluids are moved through flow systems using pumps, fans, blowers, and compressors. Such devices.
Fire Service Pump Operator ch 02 Types of Fire Apparatus
5 Pumper Apparatus Overview. 5 Knowledge Objectives (1 of 2) Explain the importance of understanding the fire pump and its systems. Describe the exterior.
Unit - #6 Air Brake System
Section 703 Apparatus Inspection. Procedures The driver/operator should follow a systematic procedure for inspecting apparatus This ensures that all important.
Tweety Operation Manual. Refurbish History Motor 1) Cummings Diesel (V6), ) Red Line 3000 (hums at 2800) 3) Top Speed 60 MPH.
Welcome to drill! Hand Tools Village Streets Know Your Trucks What Knots Backdraft Trivia Fire Basics $100 $200 $300 $400 $500.
Vehicle Characteristics/Pre-Checks/ Driving/Winching
Aerial Apparatus Operator Positioning Aerial Apparatus.
S PARTAN ERV 8415 NEW VEHICLE INFORMATION. Spartan ERV 8415 Diesel Exhaust Fluid – Location, maintenance, indicator faults Exhaust Regeneration – What.
Deck Crane.
Red/Green Fire Fighting Systems Fi Fi Mains ●Red System: Port Side Fire Main supplies two Monitors. M7 (6000) gpm on centerline on the fwd Wheelhouse top.
Engine Speed Amps Engine Temp. Engine Oil Pr. Trans. Fluid Pr. Battery overheat Engine overheat Exhaust hose overheatExhaust overheat Low oil pressure.
LOS ALAMOS FIRE DEPARTMENT
Montgomery County Fire Rescue Medical Ambulance Bus 20 Patient Capacity.
Types of Fire Apparatus Equipped with a Fire Pump Sugar Land Fire Department Driver/Operator—Pumper Academy Spring 2003.
Hydraulic Pressure Control
Tractor Safety, Operation, and Maintenance
Fire Service Pump Operator - 05 Pumper Apparatus Overview.
VACTOR COMBO FAN | jjei.com CHASSIS BODY BODY
Tractor Safety, Operation, and Maintenance
Troubleshooting Hydraulic Pumps
MVP vs PUC Custom Chassis Ferrara MVP – Extruded Cab & Body Pierce PUC
750# with optional front jacks & waterway in rescue mode
Hydraulic Pressure Control
Pumps and Lift Stations
BALTIMORE COUNTY FIRE-RESCUE ACADEMY Brush Unit Overview.
Presentation transcript:

Introduction to Truck 3 Pierce 105’ Aerial Ladder 29 Introduction to Truck 3 Pierce 105’ Aerial

Quint According to Fire Department Aerial Apparatus, First Edition. Quints : Apparatus equipped with pumps, water tanks, ground ladders, and hose beds in addition to the aerial device.

How is L29 equipped? PUMP: 1500 GPM Waterous pump TANK: 200 gallon water tank LADDERS: 35’ Extension 24’ Extension 14’ Extension 16’ Roofer (qty: 2) 10’ Attic

Cont. HOSE BED: 5” LDH Total = 860 ft 800’ of LDH supply 30’ pony at front LDH intake 30’ pony at Officers rear compartment 1 3/4” hose Total = 800 ft 200’ Drivers preconnect (qty: 2) 150’ Apartment bundle (qty: 2) 100’ Rolled in crows nest

Cont. HOSE BED: 2 1/2” hose Total = 330 ft 300’ of 2 ½” Reverse 30’ pony in Drivers jump seat AERIAL DEVICE: 105’ Hydraulic ladder Max horizontal length = 100 ft Max weight rating at full horizontal extension = 450 lbs dry / 250 lbs wet

Cont. AERIAL DEVICE: 105’ Hydraulic ladder Max vertical height = 106 ft Max weight rating at 70° to 75° = 500 lbs dry/ 500 lbs wet

Overview 450 Hp Detroit Diesel Single chassis Triple axle 105’ Telescoping Aerial ladder Box type stabilizers Back-up 12 Vdc hydraulic pump Weight = 33 tons

Key items to note Stabilizer Beam Control Drivers front & rear Officers front & rear Order of controllers In / Out are outside levers Up / Down are inside levers front –rear rear-front

Key items cont. Stabilizer Control Panel HI - IDLE Kicks up rpms for more power to hydraulic pump Makes Stabilizer or Aerial functions quicker

Key items cont. Stabilizer control panel AERIAL DIVERTER Switches hydraulic power between Stabilizers and Aerial device Should only be used with motor at idle Exception is when apparatus pump is operating

Key items cont. Stabilizer control panel Back up emergency pump EMERGENCY HYDRAULIC POWER Back up emergency pump Electric motor powered by 12 Vdc truck batteries Use switch and hydraulic valve at same time Use 1 min on 1 min off for proper cool down until aerial is bedded

Key items cont. Stabilizer control Panel STABILIZER NOT FULLY EXTENDED OVERRIDE Allows for short jacking Must have one side fully extended Takes 2 FF to operate Hold until aerial unbedded Operate over extended side only

Key items cont. Stabilizer control panel ROTATION LIMIT OVERRIDE Allows aerial to be rotated over short jacked side It is against dept PPG to operate over short jacked side. IT SAYS NEVER!

Key items cont. Stabilizer Control Panel INDICATOR LIGHTS

Aerial control pedestal Important switches Nozzle master Aerial remote master High idle Hydraulic emergency pwr

Aerial control pedestal Other items Nozzle controls Aerial controls Stability indicator Water flow indicator System pressure gauge Other indicators

Apparatus rear Level indicators Max front to rear deg° = 6 ½ ° Max side to side deg° = 5 ½ ° Aerial waterway drain Emergency override switch

Officers side Hydraulic oil reservoir Primer fluid

Officers side cont. Oil and Trans. fluid Primer fluid

Pinnable waterway Two positions Fly- water tower operations Mid- rescue operations

Pinnable waterway cont. Always pinned in rescue position

Stabilizers Box style Must extend prior to putting down Must use pads Must use pins

Things not discussed Ladder operations Pump panel Questions?