Design and Simulation of a MEMS Piezoelectric Micropump Alarbi Elhashmi, Salah Al-Zghoul, Advisor: Prof. Xingguo Xiong Department of Biomedical Engineering,

Slides:



Advertisements
Similar presentations
MICROELECTROMECHANICAL SYSTEMS ( MEMS )
Advertisements

Professor Richard S. MullerMichael A. Helmbrecht MEMS for Adaptive Optics Michael A. Helmbrecht Professor R. S. Muller.
MEMS Rigid Diaphragm Speaker
The «Lab-On-a-Chip» Concept Initiated in the 1990’s, Lab-On-a-Chip (LOC) technology represents a revolution in laboratory experimentation. The main benefits.
Oct 2011ECS Boston 220 Miniaturisation and Integration of a Cantilever based Photoacoustic Sensor into Micro Micromachined Device M.F. Bain 1, N. Mitchell.
Design and Simulation of a Novel MEMS Dual Axis Accelerometer Zijun He, Advisor: Prof. Xingguo Xiong Department of Electrical and Computer Engineering,
MICROFLEX S Beeby, J Tudor, University of Southampton Introduction to MEMS What is MEMS? What do MEMS devices look like? What can they do? How do we make.
MEMS Gyroscope with Electrostatic Comb Actuation and Differential Capacitance Sensing Haifeng Dong, Zheng Yao, Advisor: Xingguo Xiong Department of Electrical.
An Introduction to Electrostatic Actuator
MEMS Tuning-Fork Gyroscope Group 8: Amanda Bristow Travis Barton Stephen Nary.
Project #3: Design of a MEMS Vertical Actuator Jianwei Heng Alvin Tai ME128 Spring 2005.
Applications: Actuated Systems
John D. Williams, Wanjun Wang Dept. of Mechanical Engineering Louisiana State University 2508 CEBA Baton Rouge, LA Producing Ultra High Aspect Ratio.
Figure 7 Design and Simulation of a MEMS Thermal Actuated Micropump Shiang-Yu Lin, Huaning Zhao, Advisor Prof. Xingguo Xiong Department of Biomedical Engineering,
Maastricht, January 25-29, MEMS 2004 Website: Plastic Micropump using Ferrofluid and Magnetic Membrane Actuation C. Yamahata and M.
Micropumps/Microvavles. Outline Different types of micropumps  Mechanic pump Membrane pump Diffuser pump  Non-Mechanic pump Bubble pump Electrohydrodynamic.
Applications: Angular Rate Sensors (cont’d)
Processing and Characterization of Piezoelectric Materials into MicroElectroMechanical Systems Weiqiang Wang.
A NOVE LOW-TEMPERATURE MICROCAP PACKAGING USING SU-8 BONDING Y.K. Kim, S.W. Kim, and B.K. Ju Korea,Chungju National,Chungju and University,KOREA Tranducer.
MEMS Cell Adhesion Device Andrea Ho Mark Locascio Owen Loh Lapo Mori December 1, 2006.
SOIMUMPs Process Flow Keith Miller Foundry Process Engineer.
MEMs Fabrication Alek Mintz 22 April 2015 Abstract
ME381 – Final Project Kenneth D’Aquila and Sean Tseng
Theoretical Analysis of a Nanosensor based on WO 3 coated Carbon Nanotube for Ultra-high Sensitive Breath Acetone Sensing Ming Xia, Advisor: Prof. Xingguo.
Microfluidics: Catalytic Pumping Systems Paul Longwell Hollidaysburg Area High School Summer 2005.
Small Size, Big Impact – Exploring the Potentials of Micro/Nano Technologies Xingguo Xiong Dept. of Electrical & Computer Engineering, University of Bridgeport,
McGill Nanotools Microfabrication Processes
Bidirectional field-flow particle separation method in a dielectrophoretic chip with 3D electrodes Date : 2012/12/24 Name : Po Yuna Cheng( 鄭博元 ) Teacher.
Device Design: Stage 2 (Modified Microchannel Design) Device Objective –To test the viability of a two-level passive micro-fluidic device Modifications.
Microfluidic System for Automatic Cell Culture Chun-Wei Huang, Song-Bin Huang, Gwo-Bin Lee Department of Engineering Science, National Cheng Kung University,
Salem Cherenet, Kyle Jacobs, Keng Hsu, Nicholas Fang Department of Mechanical Engineering, College of Engineering, University of Illinois at Urbana-Champaign.
1 MEMS (Microelectromechanical Systems) Growing in a Shrinking World A Seminar on.
Microfluidics Propulsion & System Integration in MEMS Devices.
指導老師:許藝菊 學生:邱建龍 介電電泳(DEP)基於微流體粒子分離器Dielectrophoresis (DEP) Based Microfluidic Particle Separator.
2005 년 1 학기 논문세미나 A Novel Micromachined Pump Based On Thick-Film Piezoelectric Actuation Michael Koch, Nick Harris, Alan G. R. Evans, Neil M. White and.
Figure 17.1: Evolution from MEMS to NEMS to molecular structures. Nanostructures may have a total mass of only a few femtograms. In the nanomechanical.
Introduction to CMOS VLSI Design CMOS Fabrication and Layout Harris, 2004 Updated by Li Chen, 2010.
BIOPARTICLE SEPARATION AND MANIPULATION USING DIELECTROPHORESIS Advisor: Yi-Chu Hsu Student: Le Van Cong ( 黎 文 功 ) Date: 11/04/2011.
And are the standard deviation of the mass fraction of species at the inlet and outlet of micromixer, is the mass fraction of species at the inlet. Assume.
Device Design: Stage 2 (Modified Microchannel Design) Device Objective –To test the viability of a two-level passive micro-fluidic device Modifications.
1 M. Chitteboyina, D. Butler and Z. Celik-Butler, Nanotechnology Research and Teaching Facility University of Texas at Arlington
Modeling and Design Diaphragm Micropump
Longitudinal Motion Characteristics between a Non- Matched Piezoelectric Sensor and Actuator Pair Young-Sup Lee Department of Embedded Systems Engineering,
Optimization of T-Cell Trapping in a Microfluidic Device Group #19 Jeff Chamberlain Matt Houston Eric Kim.
CMOS VLSI Fabrication.
Electrochemical Bubble Valves Center for Bio-Mems,State University of NewYork at Buffalo.
Optimization of T-Cell Trapping in a Microfluidic Device Group #19
C A microfluidic device was created in order to mix the contents of two reservoirs through a 200um-wide, 30mm-long diffusion channel. Flow Characterization.
MICROCHANNEL DESIGN ISSUES Susan Beatty Anne Samuel Kunal Thaker.
Integrated Microfluidic Systems for Automatic Glucose Sensing and Insulin Injection 1 Chao-June Huang, 2 Chih-Hao Wang, 3 Yi-Hsin Chen, 3 Tse-Chuan Chou.
In this poster, a reconfigurable microvalve array for BioMEMS lab-on-a-chip application is proposed. The device is connected to one inlet port and multiple.
Date of download: 7/8/2016 Copyright © ASME. All rights reserved. From: Dynamic Characterization of a Valveless Micropump Considering Entrapped Gas Bubbles.
Utah Nanofab Design Review Meeting Device Architecture (Top View Layout and Layer Cross Section) Recipes & Settings Standard Concept Equipment & Tools.
Objective Functions for Optimizing Resonant Mass Sensor Performance
Roer Eka Pawinanto, Jumril Yunas and Burhanuddin Yeop Majlis
Etching Processes for Microsystems Fabrication
SELF-FOLDING TECHNIQUE
MEMS, Fabrication Cody Laudenbach.
11th International Conference on Mechanical Engineering (ICME2015)
Characterisation of the back-etched stack
Tong Zuo, Xiaoliang Li, Soumil Shah, Advisor: Prof. Xingguo Xiong
MEMS IN AEROSPACE APPLICATIONS
Xiaoxiao Sheng, Xingguo Xiong
Process flow part 2 Develop a basic-level process flow for creating a simple MEMS device State and explain the principles involved in attaining good mask.
Working Principle and Structural Design Conclusions and Further Work
Memscap - A publicly traded MEMS company
Active Reciprocating Compressor Valve Assembly P16452
MicroElectroMechanical Systems
SILICON MICROMACHINING
BONDING The construction of any complicated mechanical device requires not only the machining of individual components but also the assembly of components.
Presentation transcript:

Design and Simulation of a MEMS Piezoelectric Micropump Alarbi Elhashmi, Salah Al-Zghoul, Advisor: Prof. Xingguo Xiong Department of Biomedical Engineering, University of Bridgeport, Bridgeport, CT Abstract MEMS micropumps are important components for many bioMEMS devices such as Micro Total Analysis System (μTAS), Lab-on-a-chip, and microdrug delivery systems. Many activation techniques can be used in pumping the microfluid in MEMS pumps; among them, piezoelectric activation is an attractive one due to its low cost and simple fabrication. In this poster, the design and simulation of a MEMS piezoelectric micropump is proposed. The device consists of top and bottom silicon structures that are bonded together. Two valves are embedded in the pump on the both side: one inlet, and one outlet. In addition, the piezoelectric material is bonded on the diaphragm on the top part. When voltage is applied to the piezoelectric actuator, the membrane bends down and up, which makes the inlet and outlet valves open and close, with both valves moving in the same direction. Hence, fluid is pumped into the chamber from the inlet valve and pumped out from the outlet valve. A theoretical model is used to analyze the working principle of the micropump. Based on analysis, a set of optimized design parameters are suggested. ANSYS simulation has been used to verify the function of the device. A fabrication flow has been suggested for the fabrication of the micropump. The proposed micropump can be used for various bioMEMS applications. Micropumps are MEMS (Microelectromechanical Systems) actuators used to drive microfluid to flow toward certain destination. Micropumps usually refer to the pumps that are fabricated on the scale of microns (1μm=10 -6 m). Various micropumps based on different actuation techniques have been reported, such as electrostatic micropumps, piezoelectric micropumps, thermodynamic micropumps, smart polymer micropump, magnetic micropumps, etc. Among them, piezoelectric micropumps are attractive designs due to their easy operation and large pumping force. In a piezoelectric micropump, a pumping chamber is connected to inlet and outlet ports, with one-way microvalves to regulate the pumping flow direction. The pumping chamber is sealed by top diaphragm, with a piezoelectric actuator deposited on top of it. When AC driving voltage is applied, piezoelectric actuator will expand and shrink periodically, causing the diaphragm to bend up and down. Hence the microfluid is sucked into the chamber from inlet, and pumped out from outlet periodically. Due to their small size, low cost, low power consumption, and high efficiency, micropumps have been widely used in many applications in the field of Biomedical Engineering such as Micro Total Analysis System (μTAS), Lab-on-a-chip, and micro drug delivery systems. Introduction Piezoelectric Micropump Design Based on theoretical analysis, we derived a set of optimized design parameters of the piezoelectric micropump, as shown in Table 1. According to the design parameters, the piezoelectric micropump has the intrinsic vibration frequency of 60 Hz. ANSYS FEM simulation is used to extract the vibration modes as well as the stress distribution of the device. The bending shape of the diaphragm structure under given voltages can also be observed. The ANSYS simulation results are in good agreement with theoretical prediction. The first five vibration modes and the corresponding resonant frequencies of the micropump are shown in Figures 5 – 9. Conclusions and Future Work In this project, a bulk-micromachined piezoelectric micropump design is proposed. The working principle of the micropump is analyzed in details. The bending of diaphragm and pumping rate of the micropump are derived. Based on the analysis, an optimized design is suggested. ANSYS simulation is used to verify the performance of the device. The fabrication flow of the device is also proposed. The fabrication is based on Si DRIE etching and silicon direct bonding (SDB) techniques. In the future work, we will further improve the device’s performance, such as increasing the pumping flow rate and reducing the driving voltage of the micropump. In this poster, a bulk-micromachined piezoelectric micropump is proposed. The proposed micropump consists of two parts: top and bottom silicon structures with piezoelectric material located in the top diaphragm. Both top and bottom structures are shown in Figure 1. In the top silicon structure, it is a square shape that has a gap in the middle. The square shape also has two inlet and outlet valves. In the bottom silicon structure, it has a gap in the middle with two openings. Both top and bottom structures are bonded together via silicon direct bonding technique. When the piezoelectric material bends the diaphragm down, the outlet valve will open to allow fluid to exit the system while the inlet valve will be closed and vice versa. Figure 1. 3D view of the structure of a MEMS Piezoelectric Micropump Figure 5. First vibration mode of micropump (f = 0.634kHz) Figure 10. Sensitivity analysis when experiencing pressure of 10 MPa Figure 11. Stress contour plot when experiencing pressure of 10 MPa Device Fabrication The device is fabricated with bulk-micromachining process, as shown in Figure 12. The top and bottom silicon structures are fabricated with DRIE (Deep Reactive Ion Etching) etching separately. Aluminum is used as etching mask for Si DRIE etching. After that, the top and bottom structures are aligned and bonded together with Silicon Direct Bonding (SDB) technique. The steps are listed as follow: (1) deposit Al layer on Si wafer; (2) photolithography to define the chamber and valves; (3) etching a small area to define the chambers of the pump; (4) Remove Al layer and re-deposit Al layer as etching mask; (5) Use photolithography to define the valves (6) mask-less etching until the valves structure are formed (7) the bottom structure will follow the same steps. (8) top and bottom structures are aligned and bonded together with silicon fusing bonding, device is fabricated. For each selective silicon etching, it has seven sub-steps: (1) Oxidation; (2) Photoresist spinning; (3) Photoresist patterning; (4) Al etching; (5) Photoresist removal; (6) Silicon DRIE etching; (7) Al removal. During the bonding process, precise alignment is required to ensure the proper function of the device. Assume the diameter, thickness, and operation voltage of the PZT material are d, h and u separately, the frequency of operation is f (~60 Hz). The resulted flow rate of the micropump can be derived by calculating the stroke volume. Since the PZT material in design has a square shape, we can approximate the diameter by calculating the volume of a cube and comparing it with the volume of a cylinder. In our micropump design, the diameter is µm. V stroke = 8 x x (d / h) x u V stroke = 4.15 x µL Flow rate = V stroke × f = 4.15 x X 60 = 2.49 µL/sec = µL/sec Table 1. The optimized design parameters of the MEMS Piezoelectric Micropump Figure 4. Dimensions of the top view Piezoelectric Micropump Design Optimization and Simulation Figure 6. Second vibration mode of micropump (f = 0.641kHz) Figure 2. Undeformed shape of the micropump (top structure) Figure 3. Undeformed shape of the micropump (bottom structure) Figure 7. Third vibration mode of micropump (f = 0.817kHz) Figure 8. Fourth vibration mode of micropump (f = 0.826kHz) Figure 9. Fifth mode of piezoelectric micropump (pumping mode, f = 0.862kHz) 2000um 600um 800um 1200um 4000um 1200um 400um Diaphragm 2 - Piezoelectric Actuator 3 - Top cover 4 - Valve 5 - Chamber 6 - Bottom Structure Theoretical Analysis Measurement VariablesValues Width of valve (μm) 2000 Length of valve (μm) 210 Thickness of pump wall (μm) 400 Width of pump (μm) 4000 Length of pump (μm) 4000 Thickness of PZT (μm) 8 Length of PZT (μm) 800 Width of PZT (μm) 800 Height of pump (μm) 610 Driving voltage (v) 50 Operating frequency (Hz) 60 Flow rate (µL/min) Deposit Al layer2. Photolithography3. DRIE etching of Si 4. Deposit Al layer5. Photolithography4. DRIE etching of Si Fabrication process of top structure Fabrication process of bottom structure Bonding of top and bottom structures Figure 12. Fabrication flow of the micropum (cross-sectional view)