Neonatal Options for the 3100A. VIASYS Healthcare, Inc. Neonatal Options for the 3100A Early Intervention Pro-Active Rescue.

Slides:



Advertisements
Similar presentations
Bronchopulmonary Dysplasia(BPD) Kumari Weeratunge M.D. PL - 2.
Advertisements

Improving Oxygenation
Mechanical Ventilaton Ramon Garza III, M.D.. Indications Airway instability Most surgical patients or trauma Primary Respirator Failure Mostly medical.
David W. Chang, EdD, RRT University of South Alabama.
Educational Resources
CPAP Respiratory therapy EMT-B. CPAP Overview  Applies continuous pressure to airways to improve oxygenation.  Bridge device to improve oxygenation.
Tutorial: Pulmonary Function--Dr. Bhutani Clinical Case 695 g male neonate with RDS, treated with surfactant and on ventilatory 18 hours age:
Mechanical Ventilation in the Neonate RC 290 CPAP Indications: Refractory Hypoxemia –PaO2 –Many hospitals use 50% as the upper limit before changing.
Pulmonary Oedema.
Dr Tristan GR Dyer RCSEd Fellow in Pre-hospital Emergency Medicine.
Respiratory distress Cause of significant morbidity and mortality
3100B Theory of Operation and Controls. VIASYS Healthcare, Inc. 3100B Theory of Operation and Controls Approved for sale outside the US in 1998 for patients.
Respiratory Distress Syndrome
PULMONARY AIR LEAK SYNDROME RT 256. AIR LEAKS: Pathophysiology High transpulmonary pressures applied to the lungs Alveoli overdistend and rupture Air.
3100A Ventilator. VIASYS Healthcare, Inc. 3100A Ventilator Approved in 1991 for Neonatal Application for the treatment of all forms of respiratory failure.
High Frequency Ventilation
MECONIUM ASPIRATION SYNDROME
Chapter 39 Lung Expansion Therapy
Respiratory distress in newborn 4 th year seminar.
Meconium Aspiration Syndrome Edited May  PO 2 L --> R ductus arteriosus shunt Ventilation Remove Placenta Ductus Venosus Closes  Systemic Vascular.
1 HFPV VDR4 ® Definition: “The VDR ® is classified as a pneumatically powered, pressure regulated, time cycled, high frequency flow interrupter.” - Delivers.
3100B Ventilator. VIASYS Healthcare, Inc. 3100B Ventilator Approved for sale outside the US in 1998 for patients weighing > 35 kg failing CMV Approved.
08/14/061 HFOV vs. Conventional Ventilation Latoya Robinson Julie Ordones Joshua Globke Matthew Heaton.
Theory of HFV.
Respiratory Failure Sa’ad Lahri Registrar Dept Of Emergency Medicine UCT / University of Stellenbosch.
Building a Solid Understanding of Mechanical Ventilation
MECHANICAL VENTILATION
1 Elsevier items and derived items © 2010 by Saunders, an imprint of Elsevier Inc. Chapter 19 Mechanical Ventilation of the Neonate and Pediatric Patient.
Ventilators All you need to know is….
Dr Chaitanya Vemuri Int.Med M.D Trainee.  The choice of ventilator settings – guided by clearly defined therapeutic end points.  In most of cases :
1 © 2013 Cengage Learning. All Rights Reserved. May not be copied, scanned, or duplicated, in whole or in part, except for use as permitted in a license.
CPAP Murila fv. Respiratory distress syndrome 28% of neonatal deaths are due to prematurity The most common respiratory disorder in the preterm is Respiratory.
Copyright © 2011, 2007 by Mosby, Inc., an affiliate of Elsevier Inc.
ARTERIAL BLOOD GAS ANALYSIS Arnel Gerald Q. Jiao, MD, FPPS, FPAPP Pediatric Pulmonologist Philippine Children’s Medical Center.
3100B Theory of Operation and Controls. SensorMedics 3100B u Electrically powered, electronically controlled piston-diaphragm oscillator u Paw of 5 -
Gabriella Bluett-Mills March 8,  Usually right sided  Generally involves 7-10 vertebrae  >100 causes severe cardiac and respiratory dysfuction.
Neonatal Ventilation: “The Bivent”
Part V Chest and Pleural Trauma
Pandemic [H1N1] 2009 RT Education Module 2 Lung Protection.
Pulmonary Function David Zanghi M.S., MBA, ATC/L, CSCS.
Respiratory Respiratory Failure and ARDS. Normal Respirations.
Respiratory support and respiratory outcome in preterm infants PD Dr. med. Ulrich Thome Division of Neonatolgy and Pediatric Critical Care University Children’s.
Mechanical Ventilation Mary P. Martinasek BS, RRT Director of Clinical Education Hillsborough Community College.
Respiratory Distress Syndrome (RDS)
Nonatology: Neonatal Respiratory Distress Lecture Points Neonatal pulmonary function Clinical Manifestation The main causes Main types of the disease.
Prevention and Treatment of Ventilator-Induced Lung Injury with
CLINICAL ALGORITHM FOR THE MANAGEMENT OF INTUBATED PATIENTS PRESENTING WITH CHANGES VISSIBLE ON CxR Next step in the algorithm.
HIGH FREQUENCY VENTILATION (HFV)
Getting Inspired by High Frequency Jet Ventilation Clinical Applications and Optimization.
Clinical Simulations for the Life Pulse HFJV IMPORTANT: Tap or click on the slide to advance. Do not use the navigation arrows.
Lung Protective Jet Ventilation Basic Lung Protective Strategy for Treating RDS and Air Leaks with HFJV.
Respiratory Distress Syndrome Hyaline Membrane Disease
Is the failure of pulmonary gas exchange to maintain the normal arterial O2 and CO2 level. It is divided in to type I and II in relation to the presence.
BY: NICOLE STEVENS.  Primary objective of mechanical ventilation is to support breathing until neonates own respiratory efforts are sufficient  First.
1 Elsevier items and derived items © 2010 by Saunders, an imprint of Elsevier Inc. Chapter 20 Neonatal and Pediatric High-Frequency Ventilation.
3 nd LECTURE VENTILATORS Part One. Ventilators One of the major life support systems. Ventilators take over the vital role of the respiratory muscles.
Copyright © 2006 by Mosby, Inc. Slide 1 PART IX Diffuse Alveolar Disease.
A&E(VINAYAKA) MECHANICAL VENTILATION IN ARDS / ALI Dr. V.P.Chandrasekaran,
Several types of HFV  HFPPV  HFJV  HFOV. Principles of Oscillation Richard F. Kita BS, RRT, RCP Edited by Paula Lussier, CRT, NPS, RCP, BS.
HIGH FREQUENCY OSCILLATORY VENTILATION
Respiratory Distress in the Newborn
PRESSURE CONTROL VENTILATION
Copyright © 2006 by Mosby, Inc. Slide 1 Chapter 44 Postoperative Atelectasis Figure Alveoli in postoperative atelectasis. A, Total alveolar collapse.
Ventilator-Induced Lung Injury N Engl J Med 2013;369: Arthur S. Slutsky, M.D., and V. Marco Ranieri, M.D 호흡기 내과 / R4 이민혜 Review Article.
High frequency oscillation in patients with ALI & ARDS : systematic review and meta-analysis Sachin Sud, Maneesh Sud, Jan O Friedrich, Maureen O Meade,
Invasive Mechanical Ventilation
Ventilation Strategies in Newborn
Richard Ditsch, BS, RRT, RCVT Clinical Education Specialist
Abdallah aljazzazi Pneumothorax.
MECHANICAL VENTILATION
Presentation transcript:

Neonatal Options for the 3100A

VIASYS Healthcare, Inc. Neonatal Options for the 3100A Early Intervention Pro-Active Rescue

VIASYS Healthcare, Inc. Neonatal Options for the 3100A Rescue - is a term used to describe the infant that has failed all CMV strategies, and gas exchange continues to deteriorate; or develops airleak and is then transitioned to the oscillator.

VIASYS Healthcare, Inc. Neonatal Options for the 3100A Pro-Active - is a term applied to the infant on CMV that reaches specific thresholds and is then transferred to the 3100A prior to the onset of barotrauma or airleak.

VIASYS Healthcare, Inc. Pro-Active Establish institutional threshold or guideline as to when the 3100A will be implemented. For example: FiO 2 requirement of 60% or greater PIP requirement equal to or approaching the child’s gestational age (e.g. a 24 wk infant should not require greater pressures than the low 20’s without a concern about resulting airleak.) Deterioration of ABG’s without improvement following ventilator changes

VIASYS Healthcare, Inc. Neonatal Options for the 3100A Early Intervention - is a term used to describe the application of HFOV to an infant within the first 4 hours of life, or one that has not been conventionally ventilated. Application is usually applied to infants with RDS.

VIASYS Healthcare, Inc. Neonatal Strategies Preterm RDS (Diffuse Alveolar Disease) –Paw set at 1-2 cmH 2 O higher than CMV’s Paw –Frequency of 15 Hz for less than 1000 gms –Power of 2.0 and then adjust for minimum CWF Term or Near Term RDS –Paw set at 2-4 cmH 2 O higher than CMV’s Paw –Frequency of 10 Hz –Power of 2.0 and then adjust for adequate CWF

VIASYS Healthcare, Inc. Neonatal Strategies Airleak (Premature Infant less than 1000 gms) –Pulmonary Interstitial Emphysema (PIE) Paw set at 1 cmH 2 O less or equal to CMV’s Paw Frequency 15 Hz Power of 2.0 and then adjust for minimal CWF –Gross Airleak Paw set equal to or 1cmH 2 O higher than CMV’s Paw Frequency 15 HZ Power of 2.0 and then adjust for adequate CWF

VIASYS Healthcare, Inc. Neonatal Strategies Airleak (Term or Near Term Infant) Gross Airleak with poor inflation Paw initiated at equal to or 1-2 cmH 2 O > than CMV’s Paw Frequency at 10 Hz Power of 2.5 and then adjust for adequate CWF Gross Airleak with adequate inflation Paw set equal to or 1cmH 2 O < than CMV’s Paw Frequency at 10 Hz Power of 2.5 and then adjust for adequate CWF

VIASYS Healthcare, Inc. Neonatal Strategies Focal Pneumonia (non homogeneous) Paw equal to or 1 cmH 2 O > than the Paw in CMV Frequency of 10 down to 8 Hz Power of 2.5 and then adjust for a good CWF Infants that present with a patchy or lobar pneumonia on CXR, may not respond as well as those with diffuse lung involvement. If they present with hyperinflation, they may be at risk for airleak.

VIASYS Healthcare, Inc. Neonatal Strategies Meconium Aspiration Syndrome (Diffuse Haze) Paw at 2-4 cmH 2 O higher than CMV’s Paw Frequency of 10 down to 6 Hz Power at 2.5 and then adjust for good CWF This type of MAS will respond well to an HFOV trial. The lung is affected by the meconium liquid and produces a chemical pneumonitis/ RDS picture

VIASYS Healthcare, Inc. Neonatal Strategies Meconium Aspiration Syndrome (air trapping) Paw set equal to Paw of conventional Frequency of 8 Power of 2.5 and then adjust for good CWF Because of the presence of air trapping in this case, too aggressive use of the Paw, can further aggravate it and result in PIE or pneumothoraces. PPHN may also complicate this picture.

VIASYS Healthcare, Inc. Neonatal Strategies Congenital Diaphragmatic Hernia (CDH) Paw equal to or 1-2 cmH 2 O > than CMV’s Paw Dependent predominantly on inflation of lung on non-hernia side. Frequency 10 Hz Power of 2.5 and then adjust for adequate CWF Do not place infant on “HFOV Long Term” if it must transfer to another facility for surgery or ECMO.

VIASYS Healthcare, Inc. Neonatal Strategies Pulmonary Hypoplasia ( i.e., uniform Hydrops) Paw equal to the same Paw of CMV Increase Paw until maximum saturation of 93% Frequency of 15 Hz for < 1000 gms Frequency of 10 Hz of > 1000 gms Power of 2.0 and then adjust for minimal CWF

VIASYS Healthcare, Inc. Neonatal Strategies Prior to the use of the 3100A for Lung Hypoplasias, assess: CXR for the degree of lung inflation ABG’s for indication of gas exchange Determine if PPHN exists and to what degree Cardiac status Access to ECMO

VIASYS Healthcare, Inc. Neonatal Strategies REMEMBER- The 3100A requires use of disease specific strategies Application for diseases other than those indicated and application of an inappropriate strategy, will not result in positive outcomes. CWF stands for Chest Wiggle Factor, which may be described as a visible vibration of the chest wall from the shoulders to the umbilicus % Inspiratory Time is set to 33% for all strategies. Increasing the % I-Time may increase gas trapping.

VIASYS Healthcare, Inc. Clinical Tips for Neonatal Strategies Guideline is for initial starting point. If O 2 saturation does not improve within 5-10 min., increase the Paw until the saturation is 88-93%. Increase Paw until you see a rise in CVP or signs of decreased systemic blood flow Obtain a Chest X-Ray for observation of lung expansion to 8-9 posterior ribs or decreased opacification

VIASYS Healthcare, Inc. Clinical Tips for Neonatal Strategies Once oxygenation improves, maintain that Paw and monitor the child for changes in perfusion. Wean FiO 2 to 60% or less, re-check x-ray if diaphragm expansion is 9 rib level or more, decrease the Paw 1 cmH 2 O if diaphragm expansion is 8 to 8-1/2 rib level, continue to wean FiO 2 and monitor hemodynamics

VIASYS Healthcare, Inc. Clinical Tips for Neonatal Strategies Initial Paw in airleak is dependent on the inflation of the non air leak lung. The unaffected lung must be normalized for volume expansion. Accept less than optimal ABG’s UNTIL the airleak resolves. May see some evidence of atelectasis with the low lung volume strategy. Once no further leak from the chest tube is seen for 24 hrs, gently recruit the collapsed lung and begin weaning.

VIASYS Healthcare, Inc. Clinical Tips for Neonatal Strategies The use of Transcutaneous CO 2 is extremely helpful for preventing hyperventilation and dropping the CO 2 too rapidly. Infants less than 1000 gms will often hyperventilate at 10 Hz and minimal Chest Wiggle. If so, increase the frequency. Hypoventilation - increase amplitude by 2 cmH 2 O increments until the Chest Wiggle is optimal or decrease frequency. The Chest Wiggle should be limited to the thorax.

VIASYS Healthcare, Inc. Clinical Tips for Neonatal Strategies Use the 3100A to treat PIE the moment it is suspected or evidence of PIE on CXR is seen. The earlier application has better outcomes than following severe bilateral involvement. DO NOT aggressively increase Paw. This results in further worsening of PIE and trapped gas. Accept saturations of % initially and use higher FiO 2 ’s and PaCO 2 ’s until evidence of PIE resolution is seen.

VIASYS Healthcare, Inc. Clinical Tips for Neonatal Strategies The CDH patient with high PaCO 2 ’s may be initially stabilized on the oscillator until the child can be transported for ECMO and/or surgery. CXR rib inflation criteria normally used, does not apply to hypoplastic syndromes. Acceptable inflation may be as low as 6 ribs. Look at lung fields for lucency, and diaphragms for flatness. –e.g. Lung fields clear, diaphragms slightly flattened at 7 ribs, Paw should be left alone or decreased

VIASYS Healthcare, Inc. Clinical Tips for Neonatal Strategies A chest x-ray is needed prior to the initiation of HFOV, to assure that the appropriate strategy is applied for an MAS patient. ECMO needs to be immediately available if the patient fails HFOV. The onset of PPHN, airleak, or decreased CO may prevent a positive outcome with HFOV alone.

VIASYS Healthcare, Inc. Clinical Tips for Neonatal Strategies The oscillator is used for hypoplasia syndrome to protect the abnormally developed, small lungs and maintain ventilation. A transient improvement may be seen and then failure, which may be due to an insufficient amount of lung tissue or the onset of PPHN. HFOV as a rescue tool may not be effective in cases of hypoplasia. Early management with HFOV, to prevent barotrauma and acidosis, may improve outcomes.