Mechanical AST5300 is a wet / wet differential pressure transmitter Compatible with liquids or gases on both the high pressure and low pressure process.

Slides:



Advertisements
Similar presentations
Flow Control Valves Series FC
Advertisements

Load Cell &DP Cell 2007-CHEM-17.
Drilling Engineering – PE311 Circulating System
Water and Wastewater Focus Wireless Sales Push 2009.
Barksdale is an ISO 9001 registered manufacturer of controls for industrial applications, specializing in Pressure, Temperature, Transmitters, and Positional.
Competition Other types of flow meters Thermal Mass flow competition.
Chemigation. Chemigation Chemigation is the process of applying pesticides and fertilizer through irrigation waterChemigation is the process of applying.
4-1 Chapter 4 Overview b The DCM is very complex Mechanical, electrical, hydraulic and safety systems all work together Mechanical, electrical, hydraulic.
SS/L-TRXXXX 20 April Capacitance Manometer Transducer Bryn Asher October 19, 2009.
1 Expansion Tanks. 2 3 Expansion Tanks WHY USE THEM TYPES LOCATION SIZING.
Expect More. World’s leader in pressure technology NA Sales Training Rev B – 10/10/13.
Glycol Pumps Operating Pressure: 100 to 1500 psi Circulation Rate: 3 to 450 gph.
ECO ® Series Air Filtration Products Introducing the New ECO III Heavy Duty Air Filtration System.
VALVES TYPE & FUNCTION VALVES.
Hydraulics.
Sintering By Robert Hamilton. Introduction Sintering is a method for making objects from powder, by heating the material in a sintering furnace below.
Lubrication is the lifeblood of industry Protect your priceless assets … … AMP UP TODAY! Lubrication of the future … today! AMP Advanced Maintenance Program.
You Can Measure the Benefits… Training Course Introduction to SmartScan.
Pressure Sensors.
Actuators.
TH-57 Transmission / Hydraulic Review
Asahi/America Constant Flow Valves. Spring Orifice Plug Spring Orifice Plug 1/2”,3/4” 1”,2”,3”,4” Asahi/America Constant Flow Valves In Line Type Y Type.
Classification of Instruments :
Distributor Training Session – Planetary Speed Reducers.
October 2009 Custom Products & OEM Opportunities.
Updates to Our NACE Offering
Submersible Seal Top Down DP Level Assembly. DP Level Solution for Top-Down Level Measurement Applications Challenge: Many tanks go un-instrumented in.
Lease Automatic Custody Transfer
MOST RELIABLE COMBINATION MASTER VALVE, WATER METER AND FLOW SENSOR
Submersible Level Transmitters The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and.
You can Measure the Benefits… Training Course SolidScan’s products.
Control of Particulate Matter from a Sabatier Catalyst Bed HSL 126 Loel Goldblatt, Hamilton Sundstrand Space Systems International, Inc. Karen Murdoch,
Week 1 Unit Conversions Conservation of Mass Ideal Gas Newtonian Fluids, Reynolds No. Pressure Loss in Pipe Flow Week 2 Pressure Loss Examples Flow Measurement.
March 2010 Hastings Product Training Flow Products Overview.
Gasoline fuel supply systems Function: store, transport, Pressurize and filter gasoline going to carburetor or fuel injection system.
CHAPTER 9 Control System Instrumentation
Calibration Savvy. Calibration and Conformance  Calibration: Check a measurement against a known universally recognized standard to determine any deviation.
Use of Residual Pressure Valves - Challenges and Opportunities for Indian subcontinent. Presented By: Rohit Behani.
Calibration PT Honeywell Chapter 7 InstrumentationELC-213Today Presentation by Clifford T. Johnson, PE, Control Systems Engineer Honeywell Primer Auxiliaries.
WORKSHOP PRACTICE SAFETY VALVE.
Ultrasonic Level Transmitters The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and.
Industrial Pressure Transmitters The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers.
Differential Pressure ATEX Enclosures The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers.
Filter Sizing. Pressure drop determines filter size.
Why HIPPS ?? We have 600# (high pressure bearing) pipeline from well pads till production header. After that, we have 150# (low pressure bearing) pipeline.
Pressure Transmitters The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and current.
Hydro Multi-B – (2) or (3) CME Pumps in Parallel
Pressure Transmitters and Switches The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers.
社内資料社内資料 E-P Regulator for High Pressure up to 5.0MPa ITVX Series * This product is only for blowing, and does not have sufficient control for other application.
Valves In Industry (Part 1)
Discover the Dosmatic Difference Maintaining your Dosmatic injector for years of service.
1 Field Devices – Sales and Marketing Conference – April 2015 Field Devices 2014 BR - Confidential 1 Field Devices Foxboro® “S” Series Pressure April 2015.
ACT20X Ex isolator/ amplifier. Page 2 ACT20X (Ex isolators family) Overview - Connects to process equipment in Class/Div, or Zone 0 - Zone 2 areas - ACT20X.
BASIC AUTOMATIC CONTROLS UNIT 16 ADVANCED AUTOMATIC CONTROLS
MECH1300 Pneumatic Components Topics Pneumatic Cylinders Pneumatic Motors Other Pneumatic Actuators Pneumatic Directional Control Valves Pneumatic Flow.
BY- NAGENDRA PRATAP SINGH (TECHNICAL TRAINING ANALYST)
H & P Formulas Engineering II – August The parts and values of concern…. D 1 = diameter of cylinder (in) D 2 = diameter of piston rod (in) P 1 =
Engineering II – August 2016
Electronic Control Systems Week 3 – Switches and Sensors
Cylinder Cushioning mechanism
Asahi/America Constant Flow Valves
HOUGHTO-MIX Coolant Mixing and Supply Unit Rainer Hoerbst
Subsea 100 Global Services Products Presentation
FlexfloTM Surge Relievers
SB Packing Automatic Downpuller Power Unit
Prepared by Dr. Mohamed Ahmed Awad
Asahi/America Constant Flow Valves
Fuel Supply System Chapter 21 Lesson 1.
Cu67 Isotope Radiator & Target
Presentation transcript:

Mechanical AST5300 is a wet / wet differential pressure transmitter Compatible with liquids or gases on both the high pressure and low pressure process connections Metals that will come into contact with the liquids and gases are 316L and Inconel x750

Mechanical Uses LVDT technology A rod is connected to a corrugated diaphragm and moves up and down as the pressure changes LVDT’s are one of the oldest, yet most accurate sensor technologies in the world To learn more, visit: utorial.html utorial.html

Mechanical In order to protect against extreme over pressures, the main sensor body features an over-travel stop, so the diaphragm cannot extend beyond its normal operating conditions. The current design offers a 1500 PSI maximum line pressure across both process connections. If pressure is applied to one port first, it is recommended that pressure is kept below 500 PSI. See the datasheet for further details if pressure exceeds 500 PSI.datasheet

Mechanical The standard Process connection is 1/4" NPT Female. The upstream pressure is marked “H” and the downstream pressure is marked “L”. You will notice a hole above the H and below the L. These are cleaning ports meant only for operation at the factory. The process connections also have a miniature sintered filter. If the customer requires a new filter, they can contact the factory.

Mechanical The combination of the LVDT and the diaphragm has the following benefits: Eliminates oil-filled cavities Operates at colder temperatures No risk of process contamination as with an oil filled sensor Over pressure protection on either side prevents field failure

Electrical The AST5300 is based on the same electronics platform as the AST46HA family, using a digital ASIC to calibrate and program the transmitter over pressure and temperature. The AST5300 is programmed over pressure and temperature to remove inaccuracies. Standard output signals are available: V ratiometric, 1-5V, 0-5V, 4-20mA

Electrical

Approvals A wide variety of approvals are available. For a copy of the CSA certificate, contact the factory: Explosion Proof / AST53ED  Class I, Div. 1, Groups A, B, C, D  Class II, Div. 1, Groups E, F and G  Class III, Div. 1  Ex d IIC Non-Incendive / AST53EN  Class I, Div. 2, Groups A, B, C, D,  Ex nA IIC

Measurement Range For our initial product launch, we are offering a 0-10 PSID measurement range. AST is capable of offering other ranges, so please contact the factory with opportunities. (973)

Who Will Need It? Differential pressure transducers are commonly used for flow monitoring and filtration systems. Given the hazardous area approvals, the AST53ED or AST53EN are a natural fit for oil and gas applications. From filtration to flow monitoring, the AST5300 can be a cost effective alternative.

Who Will Need It? Non-hazardous environments, such as water and hydraulic fluid filtration systems can also be an excellent target for the AST5300, given the turn-down ratio of the line pressure to the DP range. Sealed tanks such as cryogenic liquid tanks, measure level using differential pressure transmitters. AST can provide the added service of cleaning the product to Praxair GS-38.

How do customers benefit? Price Reduction in the number of expensive 5-way valves Operating temperatures No Contamination

How much is it? Standard pricing is published on the price sheet. OEM business is our ultimate goal and the price sheet reflects our capabilities for higher volumes.

What is the lead time? Lead time is dependent on the quantity. AST has sub-assemblies in stock to manage prototype order quantities. For 100 pc releases, the first release could be 10 weeks.

Who is the competition? Rosemount Yokogawa Siemens Dwyer Ashcroft Honeywell Viatran GE Druck Endress & Hauser ABB United Electric Foxboro