Availability Based Tariff Meter

Slides:



Advertisements
Similar presentations
TURKEY AWOS TRAINING 1.0 / ALANYA 2005 TRAINING COURSE ON AUTOMATED WEATHER OBSERVING SYSTEMS ( AWOS ) MODULE C.2: COMMUNICATION SONER KARATAŞ ELECTRONIC.
Advertisements

سیستم آلارم دیجیتالی مجهز به ثبات خطا
INPUT-OUTPUT ORGANIZATION
Keypad / Display Keypad/Display Mounting 6 wire shielded cable 10’ length 3 twisted pairs Keypad Three function keys Four directions.
Troubleshooting Training Course.  Visual and General Test  Perform System Test (Mode  Perform System Test)  Identify The Error  If you need Technical.
GS3055-I GSM Universal Wireless Alarm Communicator

Metering Regulations alka NPTI, PSTI Bangalore. 1. Short title and commencement. These regulations may be called the Central Electricity Authority (Installation.
Metering & Data Processing
FIU Chapter 7: Input/Output Jerome Crooks Panyawat Chiamprasert
Presents The Silver Family An Integrated Approach to Processors, Data Communication and Head End Integration.
Reference Document1 Noise Cancellation Techniques This presentation is a property of Kaihatsu Techno Centre Pvt. Ltd. This is intended for the restricted.
Serial Communication Buses: I 2 C and SPI By Brody Dunn.
Fluke thermometer 54II Press green button to turn the thermometer on or off. If it does not turn on replace batteries.
Chapter 7 Interupts DMA Channels Context Switching.
7-1 Digital Serial Input/Output Two basic approaches  Synchronous shared common clock signal all devices synchronised with the shared clock signal data.
EET Advanced Digital Chapter 21 Serial Ports.
WIRELESS MODEM for 950 MHz DIGITAL COMMUNICATION Nerdev Sharma
CheckMeter 2.3 Portable Working Standard Page 1 March 2009.
Data Logger for Water Meter Function Continuously counts pulses from pulse output of the water meter (or other meters with pulse output) and periodically.
CheckSystem 2.1 Portable Test Systems Page 1 April 2011.
Make the most of your energy December 2008 PowerLogic Enercept Submetering ….when space is at a premium PowerLogic® Enercept Meter.
Chapter 8 Data Communication. 2 Objectives Explain various ways to connect Data Terminal Equipment (DTE) to Data Communication Equipment (DCE). Describe.
1 CCTV SYSTEMS PAN, TILT AND ZOOM CAMERAS. 2 CCTV SYSTEMS A PTZ camera is a pan, tilt, and zoom camera that is different from a fixed dome camera in that.
Embedded Systems Design
What Is Network ?. A Network is a connected collection of devices and systems, such as computers and servers, which can communicate with each other.
Technology Training that Works Hands of Data Communications, Networking & TCP/IP Troubleshooting.
USART Communication using the RS standard ETEC6416.
Baseboard Aavikkomursu 7.2. Aavikkomursu Micro- controller Extension port for programming microcontroller and sensor input Resistor RS485 interface chip.
TRANSMILLE PATs The New Alternative To Fast, Easy & Efficient Portable Appliance Testing.
1 Input/Output. 2 Principles of I/O Hardware Some typical device, network, and data base rates.
Arctic Control Introduction V 1.0. Arctic Control The Arctic Control is a device with integrated wireless communications for controlling medium-voltage.
1.Meter installation database and its up-dating on a regular interval. 2.Meter testing details and last testing done 3.Downloading of data and transmission.
PROFIBUS wiring/installation can be done with:
1. 2 ENERGY MANAGEMENT SYSTEM AN OVERVIEW AN OVERVIEW.
Cisco 1 - Networking Basics Perrine. J Page 19/14/2015 Chapter 3 Which of the following describes a network interface card? 1.Large circuit board that.
| IPV-MUX-S | IP Gateway. |2|2 | IPV-MUX-S IP Gateway Line Ports | 10/100BaseT Ethernet auto-negotiation | Fiber Optic Module, 100BaseFX |1300nm Multimode.
I Power Multimedia Technology Technologies. Higher USB The Universal Serial Bus is a means of connecting external devices such as scanners, keyboards,
1. WHAT IS METER ? A device which measures, indicates and records certain measurable quantity. 2. WHAT IS ENERGY METER ? A device which measures, indicates.
Metering & Data Processing
Line Coding, Modem, RS232 interfacing sequences.
Gauge Operation and Software by Scott A. Ager. Computer Recommendations 750 MHz Pentium III 64 Meg SRAM 40 Gig Hard Drive 1024 x 768 graphics CD Writer.
Current operation (black keys) Descriptions Parameter / protection setting (blue keys) Main points to remember A B C D ? SEPAM UMIs SEPAM UMI OPERATION.
TYPICAL SCADA SYSTEM FIELD UNIT SCADA H/W & S/W C TX O RX M E M Q N P
SPECIAL ENERGY METER STORES STORES THE FOLLOWING DATA DURING THE 10 DAYS PERIOD (i)15 MIN. BLOCKWISE ACTIVE ENERGY FOR 10 DAYS (ii)15 MIN. BLOCKWISE AVERAGE.
GS3055-I GSM Universal Wireless Alarm Communicator
Modem A Presentation Department of Computer Engineering,
GS3055-I Installation Process
© 2007 Ideal Industries 1 of 32 Intro To Ideal 800 Power Analyzer Basics of IDEAL Industries 800 Series Power Analyzer.
Introduction to RS485 Author: Zhu Tao Date:
Chapter 5 Input/Output 5.1 Principles of I/O hardware
Programmable Logic Controllers LO1: Understand the design and operational characteristics of a PLC system.
MECH1500 Chapter 3.
CheckMeter 2.1 Portable Working Standard Page 1 March 2009.
24 Feb 2009ITCN 1 Introduction to Computer Networking M Clements.
Activity 1 5 minutes to discuss and feedback on the following:
Modem. Introduction: A modem [Modulator -Demodulator] is a device. Data communication means transmitting digital information form one computer to other.
Communication.
Electricity and Circuits
Electricity and Circuits
CMV-NET Chigo VRF Network Centralized Control System
What is ASEMR /ASKUE/ and the Need for Its Implementation
Site Controller Unit and Trunk Interface Unit
Power meter SB-DN-PM1P03 SB-DN-PM3P02.
Modem A Presentation Department of Computer Engineering,
McCrometer Nano Board Test Procedure
METER SPECIFICATIONS.
PowerLogic™ offer for the basic metering market
724 Temperature Calibrator
Presentation transcript:

Availability Based Tariff Meter ER300P LARSEN & TOUBRO LIMITED

Features of ABT Meter The Meter measures Active/Reactive energy on 3 phase, 4 wire principle, Computes the active energy import /export from the substation bus bars during each successive 15 minutes block and stores it in its Memory. Integrates the reactive energy algebraically into two separate registers, A) One for the period for which the average RMS voltage is 103% or higher (High VARh), B) The other for the period for which the average RMS voltage is below 97.0% or lower (Low VARH).

Features of ABT Meter Average frequency for each successive 15-min block, as a 2-digit code Original Frequency = 49 + 0.02*2-digit code. Net Wh transmitted during each successive 15-minute block, upto second decimal, with plus/minus sign Cumulative Wh transmitted at each midnight, in six digits including one decimal Cumulative VARh transmitted for voltage high condition, at each midnight in six digits including one decimal

Features of ABT Meter Cumulative VARh transmittal for voltage low condition, at each midnight, in six digits including one decimal Date and time blocks of failure of VT supply on any phase, as a star (*) mark The meters shall store all the listed data in their memories for a period of ten days Battery back-up for data viewing display.

Basic Technical Specifications . Accuracy Class : 0.2 INTERFACE : WITH RS485 Reference Voltage(Vref) : 110V.(P-P) Rated Current ( Ib) : 5A or 1A. Operating Voltage :+20% to -30% of Vref. Operating Current : 0.2% to 200% of Ib

Display List ii) Date (year month day) :081112 d i) Meter Serial No :NP5001A ii) Date (year month day) :081112 d iii) Time ( hour min. sec. ) :151030 t iv) Cumulative Wh reading :12345.6 C v) Average frequency of the last block :49.89 F vi) Net Wh transmitted in last block :28.75 E vii) Average % voltage :99.2 U viii) Reactive power (VAR) :106.5 r ix) Voltage - high VARh register reading :01234.5 H x) Voltage - low VARh register reading :00123.4 L xi) Low battery indication

Data Collecting Device LARSEN & TOUBRO LIMITED

DCD Main Window (D) COLL. SELECTED DATA (U) PC COMMUNICATION (P) PROGRAMMING MODE (O) MEMORY STATUS CHECK (R) ACCURACY

Data Collecting Device Press (D) for Collecting of Meter Dada Press (U) for damping the data from DCD to PC 3. Press (P) for enter into Programming Mode i.e only for time adjustment for 1 minute 4. Press (O) for Memory status check

Time adjustment through DCD After connecting the Optical Port to the meter and DCD following step to be done for Time adjustment. 1. Press “P” in DCD to enter in Programming mode. 2. Enter the Password: XMISSION

Time adjustment through DCD 3. Press Enter after typing the “XMISSION” in DCD 4. Following Manu will come after pressing enter in DCD : (A) Advance (R) Retard (X) back to Manu

Time adjustment through DCD 5. i) Press “A” if the meter time is slow ii) Press “R” if the meter time is fast N.B : Program/ time adjustment (only for 1 minute) can be done one in a week. ii) Time taken to adjustment one min. 1 hrs. 30 min i.e. 6 Blocks iii) Time adjustment can be done only on power On conditions

Do’s & Don'ts with DCD Don’t keep the DCD in Suspended mode To save the battery life switch off the DCD properly DCD battery should be charged at least twice in a week Charging time is 3 hours

RS485 Network Serial Port, Local Area Communication Two-wire, multidropping Uncomplicated hardware No distance limitation within a premises

Hardware Required We have used IEC 1107 protocol for RS 485 communication. Recommended hardware is mentioned below : 1. Twisted pair with foil shielding and a drain wire Make : Belden ( Product Code 9841/8162/9501) cost Rs. 49,000 per 305m or equivalent local cable cost Rs. 2,000 per 100m. Characteristic Impedance : 120 Ohms Twist/Feet : 10 2. RS 485 to RS 232 Converter Make : Moxa Model No : Transio A53 3. PSTN Modem : Used for data transfer on PSTN Line from S/S to LDC Make : Multitech 33.6 Kbps Model No : MT2834ZDXB

The System Meter RS232 D+ Collection Point RS232 to RS485 Converter D-