Cross Hole Resistivity Survey Crinum Mine ACARP Project C12041 Demonstration of Electrical Resistivity Imaging of Coal Seams
Seismic Line Surface Resistivity line BoreholePoint on Seismic Line Seismic LineSurface ERI Line Approximate Fault One Surface Electrical Resistivity Line was surveyed using a Pole-dipole array Six cross-hole panels were surveyed using Pole-Pole array The Boundary Fault is down thrown 40 metres to the west.
You can see how seams are still aligned across the fault EG Corvus to Lilyvale Teiri 1 to Corvus Aquila to Teiri 1 A previously acquired Seismic Line has also been interpreted It gives a good indication of the complex fault-related structures at this site Note the base of Teritary (BUTE) is relatively shallow and irregular
Following the Lilyvale seam from shows it ends about here Following the Corvus seam from shows it ends about here Following the Tieri 2 seam from shows it ends about here Following the Tieri 1 seam from shows it ends about here Following the Aquila seam from shows it ends about here Following the Pliedes seams from shows they end about here Doing the same for gives: Which puts the fault at about here Keep Clicking to see the interpretation