CRM-120901-AA NOV2012 Slides adapted from those presented by Arthur J Moss, MD at AHA 2012, Los Angeles, CA USA MADIT Randomized Trial to Reduce Inappropriate.

Slides:



Advertisements
Similar presentations
SMART-AV SmartDelay determined AV Optimization: A Comparison of AV Optimization Methods Used in Cardiac Resynchronization Therapy.
Advertisements

Multicenter Automatic Defibrillator Implantation Trial II
EP Testing and Use of Devices in Heart Failure HFSA 2010 Recommendations.
Cardiac Resynchronization Heart Failure Study Cardiac Resynchronization Heart Failure Study Presented at American College of Cardiology Scientific Sessions.
Cardiovascular Disaster in Hemodialysis patients
Myocardial Ischemia: An Underrated Cause of Sudden Cardiac Death?
Subcutaneous Implantable Cardioverter Defibrillator (S-ICD)
MADIT Randomized Trial to Reduce Inappropriate Therapy (MADIT-RIT) Arthur J. Moss, MD for the MADIT-RIT Executive Committee AHA Late Breaking Trials November.
APPROPRIATE Assessment of Proper Physiologic Response with Rate Adaptive Pacing Driven by Minute Ventilation or Accelerometer.
La stratificazione del rischio aritmico oltre la frazione di eiezione Milano 17 Aprile 2009 Prof. Luigi Padeletti Heart Failure & Co.
Implantable Cardioverter Defibrillators to Prevent Sudden Cardiac Death: Background Frederick A. Masoudi, MD, MSPH Associate Professor of Medicine (Cardiology)
Outcome of Patients with Advanced Heart Failure who Receive Device- Based Therapy for Primary Prevention of Sudden Cardiac Death, G. Amit, N. Samniah,
ICD FOR PRIMARY PREVENTION EVIDENCE REVIEW
PACT Clinical Trial Commentary Dr Eric Topol Chairman and Professor, Department of Cardiology Director of the Joseph J Jacobs Center for Thrombosis and.
CRT-D Effectiveness by QRS Duration and Morphology in the MADIT-CRT Patients Wojciech Zareba, MD, PhD, Helmut Klein, MD, Iwona Cygankiewicz, MD, PhD, W.
Implantable Cardioverter Defibrillator Rebecca Boduch Biomedical Engineering University of Rhode Island.
Cardioversion of Atrial Fibrillation Clinical Issues Christopher Granger, MD Director, Cardiac Care Unit Duke University Medical Center December 2007.
ALTITUDE. DISCLAIMER Boston Scientific Education and Presentation Resources Boston Scientific develops, manufactures and markets a broad array of products.
ICD FOR PRIMARY PREVENTION EVIDENCE REVIEW
Slides adapted from those presented by Ilan Goldenberg, MD at ACC 2014, Washington, DC USA CRM AB Long-Term Survival with Cardiac Resynchronization.
Sudden death as co-morbidity in patients following vascular intervention Sudden death as co-morbidity in patients following vascular intervention Impact.
Heartland Cardiology Dr. John Dongas The Beat Goes On: Biventricular Devices.
Indications of ICD in 2010 Dr Mervat Aboulmaaty Professor of Cardiology Ain Shams University DAF 1 st EP course 2010.
Sudden Cardiac Death in Heart Failure Trial Presented at American College of Cardiology Scientific Sessions 2004 Presented by Dr. Gust H. Bardy SCD-HeFTSCD-HeFT.
SMART-AV SmartDelay determined AV Optimization: A Comparison of AV Optimization Methods Used in Cardiac Resynchronization Therapy.
RYTHMIQ™ INGENIO™ offers RYTHMIQ, which is designed to minimize unnecessary RV pacing without clinically significant pauses.
Alon Barsheshet, MD1, Paul J. Wang, MD2, Arthur J. Moss, MD1, Scott D
RYTHMIQTM for INCEPTA™ Episode Based Education
Cardiac Arrhythmias in Coronary Heart Disease SIGN 94.
Mr. J is a 70 year old man with an ischemic cardiomyopathy who presents with class III CHF and significant dissatisfaction with his functional capacity.
COURAGE: Clinical Outcomes Utilizing Revascularization and Aggressive Drug Evaluation Purpose To compare the efficacy of optimal medical therapy (OMT)
Heart Failure Ben Starnes MD FACC Interventional Cardiology
EP Show – Aug 2003 ICDs – Primary prevention The EP Show: Which ICD for which patient? Part 2: Primary prevention Eric Prystowsky MD Director, Clinical.
RESET Restoration of Chronotropic Competence in Heart Failure Patients with Normal Ejection Fraction.
AICD usage for primary prevention at Mercy Hospital: successes, challenges and next steps Mohammad Tahir PGY-3.
Renal function and clinical outcomes of patients undergoing ICD and CRTD implantation- Data from the Israeli ICD Registry Alon Eisen, Mahmoud Souleiman,
May 2005 EP Show The EP Show COMPANION and CARE-HF Eric Prystowsky MD Director, Clinical Electrophysiology Laboratory St Vincent Hospital Indianapolis,
Author Disclosures Differences in Implantation-Related Adverse Events Between Men and Women Receiving ICD Therapy for Primary Prevention Differences in.
Presenter Disclosure Information John F. Beshai, MD RethinQ Trial Results Disclosures Information: The following relationships exist related to this presentation:
Cardiac Resynchronization Therapy with Implantable Cardioverter Defibrillator (CRT-D) for Mildly Symptomatic Heart Failure.
CONFIDENTIAL SLIDE SET FOR THE CHAIR OF THE ACC08 Late Breaker; embargoed until 1 April 2008 Long-term Cardiac Arrhythmias recorded by Insertable Loop.
INTRODUCTION: INTRODUCTION: implantable cardioverter-defibrillators (ICDs) have clearly demonstrated to terminate an elevated percentage of sustained ventricular.
EP show – June 2004 EP show The EP show: Risk stratification for sudden death Eric Prystowsky MD Director, Clinical Electrophysiology Laboratory St Vincent.
EP Show – Dec 2003 ICDs – Primary prevention The EP Show: Guidelines and reimbursement at the crossroads: Primary prevention with ICDs Eric Prystowsky.
The Case for Rate Control: In the Management of Atrial Fibrillation Charles W. Clogston, M.D. Cardiologist CHI St. Vincent Heart Clinic Arkansas April.
PainFree SST Primary Manuscript Results James Coles, PhD Medtronic, Inc.
Shock Reduction History James Coles, PhD Medtronic, Inc.
Increased Patient Device Concerns But Not General Anxiety in Patients with a Secondary Indication for the ICD Susanne S. Pedersen, Professor of Cardiac.
Date of download: 6/1/2016 Copyright © The American College of Cardiology. All rights reserved. From: Inappropriate Implantable Cardioverter-Defibrillator.
CoRPS Center of Research on Psychology in Somatic diseases Poor health status in implantable cardioverter defibrillator patients: Shock, patient pre implantation.
Real World Performance of Rhythm Discrimination Algorithms in Hard-to-Treat Single Chamber ICD Patients James Coles, PhD Medtronic, Inc.
Date of download: 6/3/2016 Copyright © The American College of Cardiology. All rights reserved. From: ACC/AHA/ESC 2006 Guidelines for Management of Patients.
Ten Year Outcome of Coronary Artery Bypass Graft Surgery Versus Medical Therapy in Patients with Ischemic Cardiomyopathy Results of the Surgical Treatment.
Date of download: 6/25/2016 Copyright © The American College of Cardiology. All rights reserved. From: Indications for Implantable Cardioverter-Defibrillators.
Date of download: 6/26/2016 Copyright © The American College of Cardiology. All rights reserved. From: Clinical Effectiveness of CRT and ICD Therapy in.
Date of download: 6/26/2016 Copyright © The American College of Cardiology. All rights reserved. From: The Effect of Intermittent Atrial Tachyarrhythmia.
Date of download: 7/6/2016 Copyright © The American College of Cardiology. All rights reserved. From: Hypertrophic Cardiomyopathy in Adulthood Associated.
Ventricular Arrhythmias:A General Cardiologist’s Assessment of Therapies in 2004 C.Richard Conti M.D. MACC.
Ethical Scenario: Cardiovascular System
Sudden Cardiac Arrest Morhaf Ibrahim, MD, FHRS Electrophysiology.
Implantable Cardioverter-Defibrillators for Primary Prevention of Sudden Cardiac Death in CKD: A Meta-analysis of Patient-Level Data From 3 Randomized.
Implantable Defibrillator Therapy Post Cardiac Arrest
These slides highlight a presentation at the Late Breaking Trial Session of the American College of Cardiology 52nd Annual Scientific Sessions in Chicago,
Results from the PROVIDE Trial
2) Massachusetts General Hospital, 55 Fruit St, Boston, MA 02114
The following slides highlight a presentation at the Late-Breaking Clinical Trials session of the American Heart Association Scientific Sessions, November.
The most common cause of death in North America is cardiac death and the most common cause of cardiac death is sudden death from ventricular arrhythmias.
The EP show: sudden death, part 1 Director
Gaurav A. Upadhyay, MD, Jonathan S. Steinberg, MD  Heart Rhythm 
The Heart Rhythm Society Meeting Presented by Dr. Johan De Sutter
Presentation transcript:

CRM AA NOV2012 Slides adapted from those presented by Arthur J Moss, MD at AHA 2012, Los Angeles, CA USA MADIT Randomized Trial to Reduce Inappropriate Therapy (MADIT-RIT) Adapted from AHA Late Breaking Trial Results Presented by Arthur J. Moss, MD Professor of Medicine University of Rochester Medical Center November 6, 2012 Los Angeles, CA USA

CRM AA NOV2012 Slides adapted from those presented by Arthur J Moss, MD at AHA 2012, Los Angeles, CA USA MADIT-RIT Background  ICD is highly effective in reducing mortality in high-risk cardiac pts. 1-3  Despite sophisticated device-detection algorithms, 8- 40% of ICD therapies are inappropriate with adverse side effects 4-14  Question: can ICD devices be reprogrammed to reduce inappropriate therapies?

CRM AA NOV2012 Slides adapted from those presented by Arthur J Moss, MD at AHA 2012, Los Angeles, CA USA MADIT-RIT Study Overview Study Hypothesis:Dual-chamber ICD or CRT-D devices with high-rate cutoff (>200bpm), or duration-delay (initial 60sec monitoring plus Rhythm ID® detection will be associated with fewer 1st inappropriate therapies than standard/conventional programming (2.5sec >170bpm) without increase in mortality Study Design: Randomized, 3-arm study of patients randomized 1:1:1 to either conventional, high-rate cutoff, or duration- delay programming Primary Endpoint:First episode of inappropriate therapy (defined as shock or ATP) B arm vs. A arm C arm vs. A arm Secondary Endpoints:All-cause mortality Syncope Number of Patients: 1500 from 98 centers US, Canada, Europe, Israel and Japan Presented By:Arthur J. Moss, MD, AHA 2012

CRM AA NOV2012 Slides adapted from those presented by Arthur J Moss, MD at AHA 2012, Los Angeles, CA USA MADIT-RIT Three Treatment Arms (abbreviated)* Arm A (Conventional) Arm B (High-rate) Arm C (Duration-delay) Zone 1: >170 bpm, 2.5s delay 170 bpm >170 bpm, 60s delay Onset/Stability Detection Enhancements ON Monitor onlyRhythm ID ® Detection Enhancements ON ATP + Shock SRD 3 min initialSRD Off Zone 2: >200 bpm, 1s delay>200 bpm, 2.5s delay>200 bpm, 12s delay Quick Convert TM ATP Shock Quick Convert TM ATP Shock Rhythm ID ® Detection Enhancements ON ATP + Shock SRD Off Zone 3 : >250 bpm, 2.5s delay Quick Convert TM ATP + Shock *All programming is within approved labeling. Rhythm ID® and Quick Convert TM are trademarks of Boston Scientific Corporation For a complete listing of all programming parameters, please contact Boston Scientific at CARDIAC

CRM AA NOV2012 Slides adapted from those presented by Arthur J Moss, MD at AHA 2012, Los Angeles, CA USA MADIT-RIT Eligibility Inclusion Criteria  Primary prevention patients with no Hx of VT/VF  Sinus rhythm at enrollment; Hx PAF ok  Pt. on stable, optimal pharmacologic therapy  Age >21 yrs; informed consent Exclusion Criteria  Pt. with pacemaker, ICD or CRT-D device  CABG or PTCA in past 3 months  MI (enzyme +) or AF in past 3 months  2nd or 3rd degree heart block  NYHA IV  Chronic AF  Renal disease: BUN>50mg/dlor Creatinine>2.5mg/dL

CRM AA NOV2012 Slides adapted from those presented by Arthur J Moss, MD at AHA 2012, Los Angeles, CA USA MADIT-RIT Pre-specified End Points Primary (90% power for hazard ratio 0.5 at p<0.05)  First episode of inappropriate therapy (defined as shock or ATP) - B arm vs. A arm - C arm vs. A arm  Rationale for first inappropriate therapy (IT) - Expect reprogramming to be common after IT - Protocol allows reprogramming after IT Secondary  All-cause mortality  Syncope

CRM AA NOV2012 Slides adapted from those presented by Arthur J Moss, MD at AHA 2012, Los Angeles, CA USA Baseline Demographic and Clinical Characteristics Therapy Group ABC Conventional ≥170bpm High-rate ≥200bpm Duration-Delay ≥170bpm n=514n=500n=486 Age, yrs Male, % Ischemic, % EF, %26 No significant differences in 22 variables among the 3 Rx groups

CRM AA NOV2012 Slides adapted from those presented by Arthur J Moss, MD at AHA 2012, Los Angeles, CA USA Cumulative Probability of First Inappropriate Therapy by Treatment Group

CRM AA NOV2012 Slides adapted from those presented by Arthur J Moss, MD at AHA 2012, Los Angeles, CA USA Cumulative Probability of Death by Treatment Group

CRM AA NOV2012 Slides adapted from those presented by Arthur J Moss, MD at AHA 2012, Los Angeles, CA USA Frequency and Hazard Ratios for Inappropriate Therapy, Death, and Syncope by Treatment Group Treatment GroupsTreatment Group Comparisons # of patientsB vs AC vs A ABC Hazard Ratio P-value Hazard Ratio P-value Eventsn=514n=500n=486 1 st Inapp Therapy < <0.001 Death st Syncope

CRM AA NOV2012 Slides adapted from those presented by Arthur J Moss, MD at AHA 2012, Los Angeles, CA USA Arrhythmias Triggering First Inappropriate Therapies Treatment Group ABC Arrhythmias# Patients 1 st Inappropriate Therapies At Fib/Flut24115 Regular SVT78917 Other314 Note: marked reduction in patients with1st inappropriate therapies in High-rate (B) and Duration-delay (C) groups for At Fib/Flut and Regular SVT when compared to Conventional therapy (A).

CRM AA NOV2012 Slides adapted from those presented by Arthur J Moss, MD at AHA 2012, Los Angeles, CA USA Any Appropriate and Inappropriate Therapy by Treatment Group Treatment Groups # of Patients (% of Rx Group) ABC n=514n=500n=486P-Value Any Appropriate Therapy B vs AC vs A Shock 28 (5)26 (5)19 (4) ATP111 (22)38 (8)20 (4)<0.001 Any Inappropriate Therapy Shock31 (6)14 (3)15 (3) ATP104 (20)20 (4)25 (5)<0.001

CRM AA NOV2012 Slides adapted from those presented by Arthur J Moss, MD at AHA 2012, Los Angeles, CA USA MADIT-RIT Summary Improved ICD programming to high-rate (>200 bpm) or 60sec duration-delay is associated with: 1)~75% reduction in 1st inappropriate therapy; 2)~50% reduction in all-cause mortality Dr. Moss and his co-authors speculated that the decrease in mortality in this trial could have been related to the reduction in inappropriate shock and ATP therapies

CRM AA NOV2012 Slides adapted from those presented by Arthur J Moss, MD at AHA 2012, Los Angeles, CA USA References 1. Moss AJ, Hall WJ, Cannom DS, et al. Improved survival with an implanted defibrillator in patients with coronary disease at high risk for ventricular arrhythmia. Multicenter Automatic Defibrillator Implantation Trial Investigators. N Engl J Med. 1996;335: Moss AJ, Zareba W, Hall WJ, Klein H, Wilber DJ, Cannom DS, Daubert JP, Higgins SL, Brown MW, Andrews ML. Prophylactic Implantation of a Defibrillator in Patients with Myocardial Infarction and Reduced Ejection Fraction. New Engl J Med. 2002;346: Bardy GH, Lee KL, Mark DB, et al. Amiodarone or an implantable cardioverter-defibrillator for congestive heart failure. N Engl J Med. 2005;352: Poole JE, Johnson GW, Hellkamp AS, Anderson J, Callans DJ, RaittMH, Reddy RK, Marchlinski FE, Yee R, Guarnieri T, Talajic M, WilberDJ, Fishbein DP, Packer DL, Mark DB, Lee KL, Bardy GH: Prognosticimportance of defibrillator shocks in patients with heart failure. N EnglJ Med 2008;359: Daubert JP, Zareba W, Cannom DS, McNitt S, Rosero SZ, Wang P, Schuger C, Steinberg JS, Higgins SL, Wilber DJ, Klein H, Andrew ML, Hall WJ, Moss AJ: MADIT II Investigators. Inappropriate implantablecardioverter-defibrillator shocks in MADIT II: Frequency, mechanisms, predictors, and survival impact. J Am Coll Cardiol 2008;51: Ellenbogen KA, Levine JH, Berger RD, Daubert JP, Winters SL, Greenstein E, Shalaby A, Schaechter A, Subacius H, Kadish A: Defibrillatorsin Non-Ischemic Cardiomyopathy Treatment Evaluation (DEFINITE) Investigators. Are implantable cardioverter defibrillator shocks a surrogate for sudden cardiac death in patients with nonischemic cardiomyopathy? Circulation 2006;113: Wilkoff BL, Williamson BD, Stern RS, Moore SL, Lu F, Lee SW, Birgersdotter-Green UM, Wathen MS, Van Gelder IC, Heubner BM, Brown ML, Holloman KK: PREPARE Study Investigators. Strategic programming of detection and therapy parameters in implantablecardioverter-defibrillators reduces shocks in primary prevention patients: Results from the PREPARE (Primary Prevention Parameters Evaluation) study. J Am Coll Cardiol 2008;52: Grimm W, Flores BF, Marchlinski FE. Electrocardiographically documented unnecessary, spontaneous shocks in 241 patients with implantable cardioverter defibrillators. Pacing Clin Electrophysiol. 1992;15: Schmitt C, Montero M, Melichercik J. Significance of supraventricular tachyarrhythmias in patients with implanted pacing cardioverter defibrillators. Pacing Clin Electrophysiol. 1994;17: Theuns DA, Klootwijk AP, Simoons ML, et al. Clinical variables predicting inappropriate use of implantable cardioverter- defibrillator in patients with coronary heart disease or nonischemic dilated cardiomyopathy. American Journal of Cardiology. 2005;95: Schron EB, Exner DV, Yao Q, et al. Quality of life in the antiarrhythmics versus implantable defibrillators trial: impact of therapy and influence of adverse symptoms and defibrillator shocks. Circulation. 2002;105: Namerow PB, Firth B, Heywood GM, et al. Quality of life six months after CABG surgery in patients randomized to ICD versus no ICD therapy: findings from the CABG Patch Trial. PACE. 1999;22: Irvine J, Dorian P, Baker BM, et al. Quality of life in the Canadian Implantable Defibrillator Study (CIDS). Am Heart J. 2002;144: Klein RC, Raitt MH, Wilkoff BL, et al. Analysis of implantable cardioverter defibrillator therapy in the Antiarrhythmics Versus Implantable Defibrillators (AVID) Trial. Journal of Cardiovascular Electrophysiology. 2003;14:

CRM AA NOV2012 Slides adapted from those presented by Arthur J Moss, MD at AHA 2012, Los Angeles, CA USA CRT-D Systems from Boston Scientific Indications and Usage These Boston Scientific Cardiac Resynchronization Therapy Defibrillators (CRT-Ds) are indicated for patients with heart failure who receive stable optimal pharmacologic therapy (OPT) for heart failure and who meet any one of the following classifications:  Moderate to severe heart failure (NYHA Class III-IV) with EF ≤ 35% and QRS duration ≥ 120 ms  Left bundle branch block (LBBB) with QRS ≥ 130 ms, EF ≤ 30%, and mild (NYHA Class II) ischemic or nonischemic heart failure or asymptomatic (NYHA Class I) ischemic heart failure Contraindications There are no contraindications for this device. Warnings Read the product labeling thoroughly before implanting the pulse generator to avoid damage to the system. For single patient use only. Do not reuse, reprocess, or resterilize. Program the pulse generator Tachy Mode to Off during implant, explant or postmortem procedures. Always have sterile external and internal defibrillator protection available during implant. Ensure that an external defibrillator and medical personnel skilled in CPR are present during post-implant device testing. Advise patients to seek medical guidance before entering environments that could adversely affect the operation of the active implantable medical device, including areas protected by a warning notice that prevents entry by patients who have a pulse generator. Do not expose a patient to MRI device scanning. Do not subject a patient with an implanted pulse generator to diathermy, Do not use atrial-tracking modes in patients with chronic refractory atrial tachyarrhythmias. Do not use atrial-only modes in patients with heart failure. LV lead dislodgment to a position near the atria can result in atrial oversensing and LV pacing inhibition. Physicians should use medical discretion when implanting this device in patients who present with slow VT. Do not kink, twist or braid the lead with other leads. Do not use defibrillation patch leads with the CRT-D system. Do not use this pulse generator with another pulse generator. Precautions For specific information on precautions, refer to the following sections of the product labeling: clinical considerations; sterilization, storage and handling; implant and device programming; follow-up testing; explant and disposal; environmental and medical therapy hazards; hospital and medical environments; home and occupational environments. Advise patients to avoid sources of electromagnetic interference (EMI) because EMI may cause the pulse generator to deliver inappropriate therapy or inhibit appropriate therapy. Potential Adverse Events Potential adverse events from implantation of the CRT-D system include, but are not limited to, the following: allergic/physical/physiologic reaction, death, erosion/migration, fibrillation or other arrhythmias, lead or accessory breakage (fracture/insulation/lead tip), hematoma/seroma, inappropriate or inability to provide therapy (shocks/pacing/sensing), infection, procedure related, and component failure. Patients may develop psychological intolerance to a pulse generator system and may experience fear of shocking, fear of device failure, or imagined shocking. In rare cases severe complications or device failures can occur. Refer to the product labeling for specific indications, contraindications, warnings/precautions and adverse events. Rx only. (Rev. Q)

CRM AA NOV2012 Slides adapted from those presented by Arthur J Moss, MD at AHA 2012, Los Angeles, CA USA CRT-D Systems from Boston Scientific – PUNCTUA, ENERGEN, and INCEPTA IIndications and Usage The PUNCTUA TM, ENERGEN TM, and INCEPTA TM Cardiac Resynchronization Therapy Defibrillators (CRT-Ds) are indicated for patients with heart failure who receive stable optimal pharmacologic therapy (OPT) for heart failure and who meet any one of the following classifications:  Moderate to severe heart failure (NYHA Class III-IV) with EF ≤ 35% and QRS duration ≥ 120 ms  Left bundle branch block (LBBB) with QRS ≥ 130 ms, EF ≤ 30%, and mild (NYHA Class II) ischemic or nonischemic heart failure or asymptomatic (NYHA Class I) ischemic heart failure Contraindications There are no contraindications for this device. Warnings Read the product labeling thoroughly before implanting the pulse generator to avoid damage to the system. For single patient use only. Do not reuse, reprocess, or resterilize. Program the pulse generator Tachy Mode to Off during implant, explant or postmortem procedures. Always have external defibrillator protection available during implant. Ensure that an external defibrillator and medical personnel skilled in CPR are present during post- implant device testing. Advise patients to seek medical guidance before entering environments that could adversely affect the operation of the active implantable medical device, including areas protected by a warning notice that prevents entry by patients who have a pulse generator. Do not expose a patient to MRI device scanning.. Do not subject a patient with an implanted pulse generator to diathermy, Do not use atrial-tracking modes in patients with chronic refractory atrial tachyarrhythmias. Do not use atrial-only modes in patients with heart failure. LV lead dislodgment to a position near the atria can result in atrial oversensing and LV pacing inhibition. Physicians should use medical discretion when implanting this device in patients who present with slow VT. Do not kink, twist or braid the lead with other leads. Do not use defibrillation patch leads with the CRT-D system. Do not use this pulse generator with another pulse generator. For DF4-LLHH or DF4-LLHO leads, use caution handling the lead terminal when the Connector Tool is not present on the lead and do not directly contact the lead terminal with any surgical instruments or electrical connections such as PSA (alligator) clips, ECG connections, forceps, hemostats, and clamps. Do not contact any other portion of the DF4-LLHH or DF4-LLHO lead terminal, other than the terminal pin even when the lead cap is in place. Precautions For specific information on precautions, refer to the following sections of the product labeling: clinical considerations; sterilization and storage; implantation; device programming; follow-up testing; explant and disposal; environmental and medical therapy hazards; hospital and medical environments; home and occupational environments; and supplemental precautionary information. Advise patients to avoid sources of electromagnetic interference (EMI) because EMI may cause the pulse generator to deliver inappropriate therapy or inhibit appropriate therapy. Potential Adverse Events Potential adverse events from implantation of the CRT-D system include, but are not limited to, the following: allergic/physical/physiologic reaction, death, erosion/migration, fibrillation or other arrhythmias, lead or accessory breakage (fracture/insulation/lead tip), hematoma/seroma, inappropriate or inability to provide therapy (shocks/pacing/sensing), infection, procedure related, and component failure. Patients may develop psychological intolerance to a pulse generator system and may experience fear of shocking, fear of device failure, or imagined shocking. In rare cases severe complications or device failures can occur. Refer to the product labeling for specific indications, contraindications, warnings/precautions and adverse events. Rx only. (Rev. A)

CRM AA NOV2012 Slides adapted from those presented by Arthur J Moss, MD at AHA 2012, Los Angeles, CA USA ICD Systems from Boston Scientific ICD Indications and Usage ICDs are intended to provide ventricular antitachycardia pacing and ventricular defibrillation for automated treatment of life-threatening ventricular arrhythmias. ICDs (i.e. Vitality AVT) with atrial therapies are also intended to provide atrial antitachycardia pacing and atrial defibrillation treatment in patients who have or are at risk of developing atrial tachyarrhythmias. Contraindications Use of ICD systems are contraindicated in: Patients whose ventricular tachyarrhythmias may have reversible cause, such as 1) digitalis intoxication, 2) electrolyte imbalance, 3) hypoxia, or 4) sepsis, or whose ventricular tachyarrhythmias have a transient cause, such as 1) acute myocardial infarction, 2) electrocution, or 3) drowning. Patients who have a unipolar pacemaker. Warnings Read the product labeling thoroughly before implanting the pulse generator to avoid damage to the ICD system. For single patient use only, Do not reuse, reprocess, or resterilize. Program the pulse generator ventricular Tachy Mode to Off during implant, explant or post- mortem procedures. Always have external defibrillator protection available during implant. Ensure that an external defibrillator and medical personnel skilled in cardiopulmonary resuscitation (CPR) are present during post-implant device testing. Patients should seek medical guidance before entering environments that could adversely affect the operation of the active implantable medical device, including areas protected by a warning notice that prevents entry by patients who have a pulse generator. Do not expose a patient to MRI device scanning. Do not subject a patient with an implanted pulse generator to diathermy. Do not use atrial tracking modes (or an AVT device) in patients with chronic refractory atrial tachyarrhythmias. Do not use this pulse generator with another pulse generator. Do not kink, twist or braid lead with other leads.. Precautions For specific information on precautions, refer to the following sections of the product labeling: clinical considerations; sterilization and storage; implantation; device programming; environmental and medical therapy hazards; hospital and medical environments; home and occupational environments follow-up testing; explant and disposal; supplemental precautionary information. Advise patients to avoid sources of electromagnetic interference (EMI). Potential Adverse Events Potential adverse events from implantation of the ICD system include, but are not limited to, the following: allergic/physical/physiologic reaction, death, erosion/migration, fibrillation or other arrhythmias, lead or accessory breakage (fracture/insulation/lead tip), hematoma/seroma, inappropriate or inability to provide therapy (shocks/pacing/sensing), infection, procedure related, psychologic intolerance to an ICD system – patients susceptible to frequent shocks despite antiarrhythmic medical management/imagined shocking, and component failure. In rare cases severe complications or device failures can occur. Refer to the product labeling for specific indications, contraindications, warnings/ precautions and adverse events. Rx only. (Rev. P)

CRM AA NOV2012 Slides adapted from those presented by Arthur J Moss, MD at AHA 2012, Los Angeles, CA USA ICD Systems from Boston Scientific – PUNCTUA, ENERGEN, and INCEPTA ICD Indications and Usage PUNCTUA TM, ENERGEN TM, and INCEPTA TM ICDs are intended to provide ventricular antitachycardia pacing and ventricular defibrillation for automated treatment of life-threatening ventricular arrhythmias. Contraindications Use of these ICD systems are contraindicated in: Patients whose ventricular tachyarrhythmias may have reversible cause, such as 1) digitalis intoxication, 2) electrolyte imbalance, 3) hypoxia, or 4) sepsis, or whose ventricular tachyarrhythmias have a transient cause, such as 1) acute myocardial infarction, 2) electrocution, or 3) drowning. Patients who have a unipolar pacemaker. Warnings Read the product labeling thoroughly before implanting the pulse generator to avoid damage to the ICD system. For single patient use only. Do not reuse, reprocess, or resterilize. Program the pulse generator ventricular Tachy Mode to Off during implant, explant or post-mortem procedures. Always have external defibrillator protection available during implant. Ensure that an external defibrillator and medical personnel skilled in cardiopulmonary resuscitation (CPR) are present during post-implant device testing. Patients should seek medical guidance before entering environments that could adversely affect the operation of the active implantable medical device, including areas protected by a warning notice that prevents entry by patients who have a pulse generator. Do not expose a patient to MRI device scanning. Do not subject a patient with an implanted pulse generator to diathermy. Do not use atrial tracking modes in patients with chronic refractory atrial tachyarrhythmias. Do not use this pulse generator with another pulse generator. Do not kink, twist or braid lead with other leads. For DF4-LLHH or DF4-LLHO leads, use caution handling the lead terminal when the Connector Tool is not present on the lead and do not directly contact the lead terminal with any surgical instruments or electrical connections such as PSA (alligator) clips, ECG connections, forceps, hemostats, and clamps. Do not contact any other portion of the DF4-LLHH or DF4-LLHO lead terminal, other than the terminal pin even when the lead cap is in place. Precautions For specific information on precautions, refer to the following sections of the product labeling: clinical considerations; sterilization and storage; implantation; device programming; environmental and medical therapy hazards; hospital and medical environments; home and occupational environments follow-up testing; explant and disposal; supplemental precautionary information. Advise patients to avoid sources of electromagnetic interference (EMI). Potential Adverse Events Potential adverse events from implantation of the ICD system include, but are not limited to, the following: allergic/physical/physiologic reaction, death, erosion/migration, fibrillation or other arrhythmias, lead or accessory breakage (fracture/insulation/lead tip), hematoma/seroma, inappropriate or inability to provide therapy (shocks/pacing/sensing), infection, procedure related, psychologic intolerance to an ICD system – patients susceptible to frequent shocks despite antiarrhythmic medical management/imagined shocking, and component failure. In rare cases severe complications or device failures can occur. Refer to the product labeling for specific indications, contraindications, warnings/ precautions and adverse events. Rx only. (Rev. A)