Abstract Overview Analog Circuit EEG signals have magnitude in the microvolt range. A much larger voltage magnitude is needed to detect changes in the.

Slides:



Advertisements
Similar presentations
ECG Biopotential Amplifier ASHLEY MULCHRONE ZEXI LIU.
Advertisements

Digital Coding of Analog Signal Prepared By: Amit Degada Teaching Assistant Electronics Engineering Department, Sardar Vallabhbhai National Institute of.
Active Filters: concepts All input signals are composed of sinusoidal components of various frequencies, amplitudes and phases. If we are interested in.
ELECTROCARDIOGRAM (ECG)
Vital Signs Monitor UConn BME 4900 Vital Signs Monitor Purpose As the population ages, many people are required by their doctors to take vital signs.
Lecture 31 Electrical Instrumentation. Lecture 32 Electrical Instrumentation Electrical instrumentation is the process of acquiring data about one or.
Lecture161 Instrumentation Prof. Phillips March 14, 2003.
Digital Voice Communication Link EE 413 – TEAM 2 April 21 st, 2005.
Integrated Circuits Design for Applications in Communications Dr. Charles Surya Department of Electronic and Information Engineering DE636  6220
1 CMPT 371 Data Communications and Networking Spread Spectrum.
1 ECE 3336 Introduction to Circuits & Electronics MORE on Operational Amplifiers Spring 2015, TUE&TH 5:30-7:00 pm Dr. Wanda Wosik Set #14.
Chapter 13: Operational Amplifiers
Introduction to Op Amps
Lecture 29 Review: Frequency response Frequency response examples Frequency response plots & signal spectra Filters Related educational materials: –Chapter.
Chapter 8 Copyright © The McGraw-Hill Companies, Inc. Permission required for reproduction or display.
Electromyography: Recording D. Gordon E. Robertson, Ph.D. Biomechanics Laboratory, School of Human Kinetics, University of Ottawa, Ottawa, CANADA.
Self-Calibrating Audio Signal Equalization Greg Burns Wade Lindsey Kevin McLanahan Jack Samet.
For 3-G Systems Tara Larzelere EE 497A Semester Project.
Artifacts In Wearable Photoplethysmographs During Daily Life Motions and Their Reduction With Least Mean Square Based Active Noise Cancellation Method.
Chapter 8 Copyright © The McGraw-Hill Companies, Inc. Permission required for reproduction or display.
EE513 Audio Signals and Systems Digital Signal Processing (Systems) Kevin D. Donohue Electrical and Computer Engineering University of Kentucky.
Lecture 1. References In no particular order Modern Digital and Analog Communication Systems, B. P. Lathi, 3 rd edition, 1998 Communication Systems Engineering,
Chapter 14: Operational Amplifiers. Copyright ©2009 by Pearson Education, Inc. Upper Saddle River, New Jersey All rights reserved. Electronic Devices.
The Illinois Society of Electroneurodiagnostic Technologists (ISET) Fall Meeting: Electronics Crash Course for Technologists Saturday, November 9, 2013.
SIGMA-DELTA ADC SD16_A Sigma-Delta ADC Shruthi Sujendra.
EEG Detection and Recording Instructor: S. M. Fakhraie Presented by: Hamed Dorosti All materials are copy right of their respective authors as listed in.
Final Project Review Team Vibraid April Vibraid Michael Balanov (Mike) EE Spyridon Baltsavias (Spiros) EE Reona Otsuka (Leo) EE Andrew Woo (Andy)
Biomedical Instrumentation I
Senior Project – Electrical Engineering – 2005 Wireless Baby Monitor Nelson Rosario, Farida Siddiqi Advisors: Professor Ekram Hassib Professor Emad A.
Vital Signs Monitor UConn BME 4900 Vital Signs Monitor Purpose As the population ages, many people are required by their doctors to take vital signs.
ELECTRONIC INSTRUMENTATION & PLC DKT Signal Conditioning Circuits.
Gary O’ Donoghue Electronic & Computer Engineering, National University of Ireland, Galway Final Year Project A small number of consumer electronics.
Chapter 11 Amplifiers: Specifications and External Characteristics.
Fundamentals of Electric Circuits Chapter 5 Copyright © The McGraw-Hill Companies, Inc. Permission required for reproduction or display.
ECE 4710: Lecture #7 1 Overview  Chapter 3: Baseband Pulse & Digital Signaling  Encode analog waveforms into baseband digital signals »Digital signaling.
Introduction to MicroElectronics
Operational Amplifiers Op Amps – a useful building block K. El-Ayat 11.
The ECG UConn BME 290. Buffers What is a buffer? –Non-inverting amplifier with a gain of 1 Why use a buffer? –Buffers provide a high input impedance.
1 William Stallings Data and Computer Communications 7 th Edition Chapter 9 Spread Spectrum.
Variable-Frequency Response Analysis Network performance as function of frequency. Transfer function Sinusoidal Frequency Analysis Bode plots to display.
Networks and Mobile Systems Research Group MIT Laboratory for Computer Science nms.lcs.mit.edu RadioActive Networks: Robust Wireless Communications John.
EE101-Lecture 8 Operational Amplifier Basics of amplifiers EE101 Fall 2012 Lect 8- Kang1 Noninverting amplifier & Inverting amplifier.
Muscle Fatigue Interface Final Presentation Shay Chen, Tushar Bhushan, Roman Levitas TA: Lydia Majure ECE 445: Senior Design Project #30 April 1, 2013.
Walking Stick With Heart Attack Detection
TUNALIData Communication1 Spread Spectrum Chapter 9.
Electromyography E.M.G..
On-Site HotBox Calibration System Team 2 Pourya Assem & Paul Lupas Prof. A.C.Singer ECE 445 – Fall 2012.
 Sensor (S)–converts arbitary physical quantity into electric signal  Adaptor (A)–provides signal amplification to a required level; expands a dynamic.
EXAMPLE 2 – PHOTODIODE A photodiode is a semiconductor device that converts light into current. The current is generated when photons are absorbed in the.
Basics of Bypass Capacitor, Its Functions and Applications.
Results from Mean and Variance Calculations The overall mean of the data for all features was for the REF class and for the LE class. The.
Electronic Devices and Circuit Theory
SIGNAL CONDITIONING Signal conditioning is stage of instrumentation system used for modifying the transduced signal into a usable format for the final.
BIOELECTRONICS 1 Lec 9: Op Amp Applications By
MECH 373 Instrumentation and Measurements
Fundamentals of Electric Circuits Chapter 5
MECH 373 Instrumentation and Measurements
MECH 373 Instrumentation and Measurements
MECH 373 Instrumentation and Measurements
Industrial Instrumentation: Transmitters
Sampling rate conversion by a rational factor
Electromyography E.M.G..
Lesson 6: Sampling Analog Signals
Instrumented Walker Project Manager : Jairus Potts Rockwell Shields
Electromyography E.M.G..
Chapter 11 Amplifiers: Specifications and External Characteristics
Naoki Watanabe et al. BTS 2017;2:
8.4 Advanced RC Filters high pass filter including gain and Bode plots
Fundamentals of Electric Circuits Chapter 5
Chapter 5 Operational Amplifiers
Presentation transcript:

Abstract Overview Analog Circuit EEG signals have magnitude in the microvolt range. A much larger voltage magnitude is needed to detect changes in the signal. We used an instrumentation amplifier with R g = 560Ω to get a gain of The Arduino Mini Pro analog inputs accept voltages in the 0 – 5V range. Since EEG signals can have negative voltages, this poses a problem for the Arduino during reading. To get around this, we use a non-inverting summing circuit to shift the EEG signal from the -2.5 – 2.5V range into the 0 – 5V range. The summing circuit is currently unity gain, but offers another stage for us to introduce more gain if we need to in the future. Shielded wire does not eliminate all of the noise present in our signal. In the next analog stage, we implement a low pass filter to eliminate frequencies outside our desired range. As mentioned previously, our frequency range of interest is the 1 – 30 Hz range. The second order filter has a cutoff frequency of 29Hz. Following the low pass filter, we have a unity gain buffer that transforms the high impedance input into a low impedance input before we enter the Arduino. It has been well established that sleep is a crucial factor for productivity and even health. While ideally people should sleep for at least 8 hours a day, modern changes in work habits and cultural stresses has significantly affected not only how much we sleep, but also how we sleep. HypnoLarm targets this issue, and strives to make the most out of the sleep we get by addressing the problem from a modernistic ergonomic viewpoint. It has been proven that waking up during different sleep stages has profound and significant effects on an individual’s alertness and energy levels. HypnoLarm is a sleep optimization system that aims to use “free-form” electroencephalography (EEG) to continuously track and analyze a user’s sleep stage in real time. It can then optimizes waking for users around their desired set time through a combination of sleep stage detection and prediction. The HypnoLarm design comprises two separate modules operating in tandem with each other through a wireless communications protocol: 1.The sensor sheet An array of dry EEG sensors encased in foam to accurately record EEG signals during sleep. 2.The alarm module Processor unit which receives EEG data wirelessly from the sensor sheet, and analyzes the signals to identify sleep stages. The algorithm tracks the user’s sleep over the entire night, and determines an optimal time to wake the user around his or her desired time through a combination of sleep stage prediction and detection. EEG Signal Collection For this project, we used the Biopac Ag-AgCl dry EEG electrodes. Using CAD and 3D printing, we designed and printed electrode caps to cover and attach the shielded wire leads to the electrodes. Biopac electrode Sensor SheetAlarm module Two-stage analog and digital filtering to effectively eliminate EEG signal noise without distorting signals in spectrums of interest. Accurately extract EEG signal features of interest for determination of sleep stage. Multiplex EEG sensors to identify and select single channel with best signal quality for sleep stage analysis. Perform time continuous reading of EEG signals while performing analysis in real- time. Maintain constant sampling rate of each EEG sensor’s signal. Stable wireless communication protocol of sufficiently large data rate. Design Requirements Methodology 1.Analog low pass filtering of EEG signals in the 1 – 30 Hz range. 2.Multiplexing and sampling of EEG data using Arduino Mini processor unit. 3.Digitally filter signal at cutoff of 30Hz. 4.Cluster analysis of EEG signals using frequency domain parameters for sleep stage identification. Instrumentation AmplifierSumming Circuit Final Stage Insulative polyurethane foam ensures only voltage data from the user’s scalp is recorded. EEG electrodes spaced 1 inch apart, center-to-center in order to best replicate a clinical EEG setting. Central Arduino microprocessor unit performs multiplexing and digital low-pass filtering of EEG sensor reading, then sends data array to alarm module via Bluetooth. Sensor Sheet Final Design Alarm Algorithm During the course of this project, a cluster-analysis method was chosen to identify sleep stages from EEG data samples. This method allows for an abstraction of using signal properties to determine state. The clustering method first receives instruction for EEG signal feature parameters to extract, which may or may not be deterministic in sleep stage identification. A set of pre- scored EEG sleep data is then fed into the algorithm, and their features extracted. The algorithm then categorizes the feature vector values based on the sleep stage (cluster) for that particular sample. This is followed by PCA analysis which identifies and calculates 3 eigenvectors, from the feature parameters, that provide the greatest intra-cluster differentiation. Each sample is then plotted on a 3-D vector space and color coded for its corresponding sleep stage, with the 3 eigenvectors as the axis. Visible clusters of points for each stage of sleep is formed, and sleep stage can be identified by the cluster a sample point falls into. Sleep Stage Clusters Formed Using Pre-scored Sleep EEG Data Stage Scoring Using Clusters Overall Alarm Algorithm flow chart