Lecture 12 Molecular Photophysics

Slides:



Advertisements
Similar presentations
Big Question: We can see rafts in Model Membranes (GUVs or Supported Lipid Bilayers, LM), but how to study in cells? Do rafts really exist in cells? Are.
Advertisements

Fluorescence Fluorescent corals.
Chemistry 2 Lecture 13 Everything. Learning outcomes from lecture 12 Be able to explain Kasha’s law by describing internal conversion Be able to define.
HPLC Detectors UV-Vis Fluorescence Derek Jackson CHM410/1410 October 22, 2009
Multi-Photon Principles - topics- l Confocal complements Multi-Photon. l What is an emission event ? l Single photon event. l Stokes’ shift and what you.
OPTICAL ABSORPTION.
Molecular Fluorescence Spectroscopy
1 Molecular Luminescence Spectroscopy Lecture 31.
The iron content of runoff from a banana ranch is a necessary analytical parameter to analyze. A 25.0mL sample of the runoff was acidified with HNO3 and.
Fluorescence Spectroscopy
Electronic Spectra: Ultraviolet and Visible Spectroscopy Ultraviolet and visible light give rise to electronic excitations. Spectroscopy of organic.
Lecture 3 Kinetics of electronically excited states
Luminescence (Miklós Nyitrai; 27 th of February, 2007)
Methods: Fluorescence Biochemistry 4000 Dr. Ute Kothe.
Lecture 11 Electronic spectroscopy of polyatomic molecules
Molecular Luminescence
Molecular Luminescence Spectrometry
Molecular Luminescence Spectrometry Chap 15. Three Related Optical Methods Fluorescence Phosphorescence Chemiluminescence } From excitation through absorption.
METO 621 LESSON 7. Vibrating Rotator If there were no interaction between the rotation and vibration, then the total energy of a quantum state would be.
Light and Fluorescence
MMP+ Chapter 5 Photophysical Radiationless Transitions Kathy-Sarah Focsaneanu November 28, 2002.
Chapter 15 Molecular Luminescence Spectrometry Molecular Fluorescence  Optical emission from molecules that have been excited to higher energy levels.
INTRO TO SPECTROSCOPIC METHODS (Chapter 6 continued ) Quantum-Mechanical Properties Of Light Photoelectric Effect Photoelectric Effect Energy States of.
Molecular Luminescence
METO 637 LESSON 3. Photochemical Change A quantum of radiative energy is called a photon, and is given the symbol h Hence in a chemical equation we.
Photochemistry Lecture 2 Fates of excited states of polyatomic molecules.
Lecture 4 Intramolecular energy transfer
Wickstrom PR 613 Fluorescence. Source Dispersing Sample Detector Computer Lens Dispersing Instrumentation.
Dr. Hisham E Abdellatef 2. Spectrofluorimetry Dr. Hisham E Abdellatef
RamanRaman. Scattering Tyndall scattering – if small particles are present During Rayleigh scattering (interaction of light with relatively small molecules)
IPC Friedrich-Schiller-Universität Jena 1 6. Fluorescence Spectroscopy.
Electronic Spectroscopy
 Instructor:  Dr. Marinella Sandros 1 Nanochemistry NAN 601 Lecture 7: Quantum Chemistry_Fluorescence.
Chapter 15 Molecular Luminescence Spectrometry. A very sensitive and selective instrumental technique with some of the lowest LOD's for molecules that.
19 장 Fundamentals of Spectrophotometry Fundamentals of Spectrophotometry –19-1Properties of Light –19-2Absorption of Light –19-3 The Spectrophotometer.
Using molecules to capture solar energy
Chemistry 2 Lecture 11 Electronic spec of polyatomic molecules: chromophores and fluorescence.
Fluorescence Absorption of light occurs within ~ seconds, leaving a molecule in an excited state What happens next? –If no photon is re-emitted,
Fluorometric Analysis
Fluorescence: Quenching and Lifetimes
Chapter 15 Molecular Luminescence Spectrometry Three types of Luminescence methods are: (i) molecular fluorescence (ii) phosphorescence (iii) chemiluminescence.
How Do Materials Emit Light? Incandescence Atomic Emission Molecular Fluorescence Phosphorescence Photoluminescence.
The iron content of runoff from a banana ranch is a necessary analytical parameter to analyze. A 25.0mL sample of the runoff was acidified with HNO3 and.
Fluorescence Spectroscopy
MODULE 26 (701) RADIATIONLESS DEACTIVATION OF EXCITED STATES We have used terms such as "internal conversion" and "intersystem crossing" without thinking.
Chapter 3. Light emitting diod
1.1Excited electronic states Each electron has unique set of quantum numbers (Pauli Exclusion Principle) n principle (1s, 2s, 3s,…) langular momentum (l.
Fluorescence, Phosphorescence, & Chemiluminescence
23.7 Kinetics of photochemical reactions
Electronic Spectroscopy Hitachi-HiTec. Electronic Excitation Model A ~ X ~  Excitation (Absorption) Radiationless decay (vibrational relaxation)  Fluorescence.
Ch 10 Pages ; Lecture 24 – Introduction to Spectroscopy.
Fluorescence spectroscopy, Einstein’s coefficients Consider a molecule with two energy levels S a and S b The rate of transition.
UV SPECTROSCOPY Absorption spectra.
Electronic Spectroscopy – Emission ( ) Fluorescence is the emission of light by a molecule in the excited state Fluorescence – Decay occurs between.
1 Molecular Luminescence Spectroscopy Lecture 29.
Lecture 36 Electronic spectroscopy. Electronic spectroscopy Transition energies between electronic states fall in the range of UV/vis photons. UV/vis.
Photochemistry Photochemistry is the study of the interaction of electromagnetic radiation with matter resulting into a physical change or into a chemical.
PHCM561t WS Lecture 4 LUMINESCENCE Quinine Dr. Rasha Hanafi
The antibonding orbital is designated by an asterisk. Thus, the promotion of an electron from a π-bonding orbital to an antibonding (π *) orbital is indicated.
Molecular Fluorescence Spectroscopy
Chem. 133 – 3/9 Lecture.
Ultrafast Spectroscopy
Transient Absorption (Courtesy of Kenneth Hanson, Florida University): The technique applied to molecular dynamics Source hn Sample Detector.
Lecture 4 Intramolecular energy transfer
UV SPECTROSCOPY Absorption spectra.
The absorption spectrum of chlorophyll
Chemistry 2 Lecture 13 Everything.
For B.Pharm IIIrd yr students
Illustration of Jablonski Diagram
Overview of spectroscopy transitions
Presentation transcript:

Lecture 12 Molecular Photophysics Chemistry 2 Lecture 12 Molecular Photophysics

Learning outcomes from lecture 11 Be able to use S, D and T to label the spin multiplicity of an electronic state Be able to describe how energy is lost after absorption by radiative transitions and non-radiative transitions Be able to explain the “mirror symmetry” and Stokes shift of absorption and fluorescence spectra explained using a Jablonski diagram Assumed knowledge Electronic states are labelled using their spin multiplicity with singlets having all electron spins paired and triplets having two unpaired electrons. After absorption, energy is lost by radiative transitions and non-radiative transitions. Fluorescence spectra are red-shifted compared to absorption spectra but commonly have “mirror symmetry”

(light absorber in eye) last lecture… S1 T1 O CH3 trans-retinal (light absorber in eye) S0

Absorption spectrum of a dye 200 S3 150 S2 S3 Absorbance 100 S2 S1 50 S1 400 450 500 550 600 S0 Wavelength (nm)

Absorption to several electronic states Benzene

Showing singlet and triplet absorption Triplet states S3 S2 T2 S1 T1 S0 Absorption to triplet states from single states is formally forbidden, thus very weak.

Fluorescence spectrometer Key features: Two monochromators are needed - one to select a single wavelength to excite the molecule - the other to resolve the emitted wavelengths Excitation and detection occur at 90 to each other - this minimises the amount of incident light gets into the detector.

Fluorescence spectrometer Two types of spectra: Fluorescence spectrum - select excitation l with mono #1 - scan mono #2 to measure fluorescence spectrum Excitation spectrum - later

Real data… Absorption Fluorescence 500 550 600 650 700 Wavelength (nm) Absorption Fluorescence - Fluorescence is always to longer wavelength - Stokes shift = (absorbance max) – (fluorescence max) = 50 nm here - Mirror symmetry

Fluorescence spectrum  f(lexc) NRD Note: the non-radiative decay (NRD) only occurs in the condensed phase, where the fluorophore can transfer vibration energy to the solvent.

A bigger Stokes shift will produce more dissipation of heat Absorption The shift between lmax(abs.) and lmax(fluor) is called the STOKES SHIFT A bigger Stokes shift will produce more dissipation of heat

Franck-Condon Principle (in reverse)

Franck-Condon Principle (in reverse) Note: If vibrational frequencies in the ground and exited state are similar, then the spectra look the same, but reversed -> the so-called “mirror symmetry”

Absorption spectrum of another dye Excite dye at different wavelengths 400 450 500 550 600 50 100 150 200 Absorbance Wavelength (nm) l = 550 nm l = 440 nm l = 400 nm What will emission (fluorescence) spectra look like?

The emission is the same! lex= 400 nm lex = 440 nm lex = 550 nm * * * 400 450 500 550 600 650 700 750 800 Wavelength (nm)

Kasha’s Law: “Emission always occurs from the lowest excited electronic state” Internal Conversion (IC) S2 NRD S1 Emission S0 “Internal conversion (IC)” is the spontaneous relaxation of an electron to a lower energy state, accompanied by a simultaneous increase of vibrational energy of the molecule. IC is a non-radiative process.

Born-Oppenheimer Breakdown Terms in the Hamiltonian operator which are ignored when making the BO approximation promote transitions between states of the same energy in the molecule. Small energy gap = Good Franck-Condon factor Large energy gap = Bad Franck-Condon factor A molecule can make a non-radiative transition to an isoenergetic state. If this state can then lose vibrational energy to the solvent, it is irreversible.

Fluorescence spectrometer Two types of spectra: Fluorescence spectrum - select excitation l with mono #1 - scan mono #2 to measure fluorescence spectrum Excitation spectrum - select fluorescence l with mono #2 - scan excitation l using mono #1. Under what conditions will the excitation spectrum resemble the absorption spectrum?

Excitation Spectroscopy Absorption is a DIRECT technique for measuring an electronic transition – the direct loss of transmitted light is measured. There are other techniques to infer the absorption of light: - fluorescence excitation - phosphorescence excitation - resonant ionisation - photofragment excitation

Explanation of fluorescence excitation Because the fluorescence is the same no matter where the molecule is excited, then any (or all) fluorescence transitions can be monitored. N (fluorescence photons)  N (absorbed photons) N (fluorescence photons) = ff x N (absorbed photons) The proportionality constant, ff is called the “fluorescence quantum yield” ff can vary between 0 and 1 If ff is constant with l, then fluorescence excitation spectrum has the same shape (intensity vs l) as the absorption spectrum

Comparison of Absorption and Excitation Spectra Note the extended p-chromophore, which is responsible for the absorption. Multiple electronic states Rhodamine 6G

When absorption  excitation… Especially note this difference?? Pyrenesulfonic acid

More on Internal Conversion IC S2 Smaller energy gap IC S1 Larger energy gap IC is usually very fast between excited states and slower between S1 and the ground state. S0 Internal conversion is the relaxation of the electron to a lower level, but, accompanied by no radiation, the equivalent amount of energy is converted to vibrational energy. IC is a radiationless process

Intersystem Crossing (ISC) and Phosphorescence NRD & IC S1 ISC T1 Phosphorescence S0 “Intersystem crossing” is the flipping of an electron spin so that the molecule changes from singlet to triplet state (or vice versa). ISC is a non-radiative process and is typically 106 times slower than IC, other things being equal.

More on phosphorescence T1 T2 Triplet states S2 S1 Fluorescence Phosphorescence S0 The lowest triplet is nearly always below the first excited singlet state. Therefore phosphorescence is nearly always “red shifted” (i.e. at lower energy) than fluorescence. It is formally forbidden and about 106 times slower than fluorescence.

Everything together… ISC IC S2 T2 ISC IC S1 ISC T1 Phosphorescence S0 Absorption S2 T2 ISC IC S1 Fluorescence ISC T1 Phosphorescence S0

Phosphorescence in research Absorption spectrum phosphorescence S1←S0 S2←S0 This porphyrin molecule exhibits a huge p-system and absorbs across the visible region. The palladium metal centre promotes intersystem crossing. The molecule was synthesized in the Crossley group, and used by Schmidt’s group in solar research.

Ultrafast fluorescence Using ultrafast lasers, we can observe the porphyrin in the act of fluorescing. Here, after excitation at 300 nm, fluorescence at 680 nm builds up within 3 ps but gone after only 20 ps after which the molecules which are left are all in the T1 state and then phosphoresce on the 20 ms timescale.

How fast? One picosecond is one millionth of one millionth of a second. There are as many picoseconds in a second as there have been seconds since our species invented shoes, 40000 years ago. The bisporphyrin below has a very low S1 state. Ultrafast transient absorption experiments show that it does not undergo ISC, but rather IC is complete in 50ps. This experiment is 2 weeks old. S1←S0

Learning outcomes Be able to explain Kasha’s law by describing internal conversion Be able to define fluorescence quantum yield Be able to describe intersystem crossing and how it leads to phosphoresence Be able to explain why the phosphorescence occurs at lower energy (“red-shifted”) and is slower than fluorescence

Next lecture Week 13 homework Course wrap up Week 13 homework Electronic spectroscopy worksheet in the tutorials Complete the practice problems at the end of the lectures Note: ALL of the relevant past exam problems have been used as practice problems. Other questions on past papers include parts which are no longer part of the course.

Practice Questions The figure opposite shows the absorption, fluorescence and phosphorescence spectra of a common organic dye. Why is the phosphorescence spectrum significantly red shifted compared to the fluorescence spectrum? The spectra below show the fluorescence excitation (blue) and fluorescence emission spectrum (red) of two large molecules. Explain, the following features of the spectra, using a Jablonski diagram to illustrate your answer. The Stokes shift is quite different for molecules A and B. Explain how this difference arises, and give an example of what molecular property might give rise to a large Stokes shift. Molecule B in particular is a nice example of “mirror symmetry” between excitation and emission spectra. How does this mirror symmetry arise?

Practice Questions The two spectra below show the fluorescence excitation and absorption spectra of pyrenesulfonic acid. In addition to the identified electronic origin transitions, there are other peaks in the absorption spectrum, as indicated by “a)” in the figure. Using a Jablonski diagram, explain how these other peaks arise. In the absorption spectrum, for the S1 and S2 transitions, the origin band is stronger than the two satellite bands marked by “a)”. In the S3 transition, the origin band is weaker than the satellite, marked by “b”. Explain, using the Franck-Condon principle, how this arises. Using a Jablonski diagram, describe one such process that can give rise to the observed difference in the relative intensities of the fluorescence excitation and absorption spectra at λ < 245 nm