Augmenting Fire Standpipe Systems

Slides:



Advertisements
Similar presentations
Sprinkler Systems and Standpipe Operations
Advertisements

$200 $300 $400 $500 $100 $200 $300 $400 $500 $100 $200 $300 $400 $500 $100 $200 $300 $400 $500 $100 $200 $300 $400 $500 $100 Tip SizesNozzlesPotpourriFormulas.
Fire Protection Systems
Learning Objective 1 Describe the safety considerations taken when service testing a fire hose.
The Cleveland Load.
Chapter 13 Lesson Goal After completing this lesson, the student shall be able to use various hose appliances and tools, prepare a test site for service.
City of Black Hawk Water HammerSeptember 2002 Arber Water Hammer Travis Meyer, P.E. Richard P. Arber Associates.
Adapted From Cody Fire School Presentations Amsterdam Fire Regular Fire Training February 16, 2009.
PAPER ROCKET LAUCNHER Bob Galliher Hobart Middle School 705 e.4 th St. Hobart, In
FIRE HOSE AND APPLIANCES
Fire Hose and Appliances
CAFS On-Line Orientation
Nozzle Pressure. Designed Nozzle Pressures  Smooth Bore Nozzle - Handline 50 PSI  Smooth Bore Nozzle - Master Stream 80 PSI  Combination Nozzle - (all.

Fire Streams Geronimo Vol. Fire Dept.. Extinguishing Properties of Water G Water extinguishes fires by G Cooling G Remove heat from the fire G Smothering.
State of Georgia BASIC FIRE FIGHTER TRAINING COURSE
Hydraulic Calculations
For The Driver Operator
Tie Rod Case Study.
BS9990 : 2015 Updates and/or Changes
Experiment 8 : Minor Losses
4/15/2017 7:34 AM Fire Sprinkler Systems Prepared by Thomas Bartsch Chief Fire Inspector (ret) Former Chief of Department, Valley Stream, NY © 2007.
Pumping Apparatus Driver/Operator
CVFD Training – Water Supply SFFMA Training Objectives: –
HH H OUSTON H OUSTON F IRE F IRE D EPARTMENT P UMP P UMP O PERATOR O PERATOR P ROGRAM VAL JAHNKE TRAINING FACILITY.
Fire Streams SFFMA Training Objectives: –
Automatic Sprinkler System. Importance of Sprinklers First line of protection – small fires Enhanced protection Business protection – less interruption.
FIREFIGHTER I LESSON 15. SPRINKLER SYSTEM DESIGN AND OPERATION Series of sprinklers arranged to automatically distribute enough water to extinguish or.
March 2001 Training Hillcrest Fire Department. Before we get started Pair up with someone Take and record their vitals.
WATER FOR FIRE PROTECTION (Chapter 26) Basic factors of fire – Rapid oxidation of combustible materials – A combination of oxygen, fuel, and heat is required.
WATER SUPPLY Copyright© Delmar is a division of Thomson Learning.
Purpose of Standpipe and Hose Systems
NOTRE DAME FIRE SCHOOL 2004 FIRE PUMPS 101 CAPTAIN TROY KERCKHOVE SOUTH BEND FIRE.
C L A S #4 Driver Operator Refresher Training.
Pumping Apparatus Driver/Operator
Pipe Fittings. Purpose of Pipe Fittings  Plumbing fittings have different shapes which allow rigid straight pipe to change both direction and diameter.
Augmenting Sprinkler Systems
Module C Sprinkler systems (4-20)
Fire Hoses, Nozzles, Portable lighting, appliances, and ladders.
Fire Hose, Nozzles, Streams, and Foam
Learning Objective 1 Explain the ways water supply system components are used by firefighters.
Dewatering Equipment.
Instructor Lee Lautzenheiser
FIREFIGHTER II LESSON 12. TYPES OF VALVES Ball — Ball — Controls nozzle flow and pump discharge rates Gate — Gate — Controls hydrant flow Butterfly.
1402 Hybrid Firefighter II 6th Edition Chapter 15 — Fire Hose South Carolina Fire Academy.
CHAPTER 9 Copyright © 2007 Thomson Delmar Learning 9.1 Water Supply.
Pumping Apparatus Driver/Operator
MODULE:3 FIRE CONFINMENT AND EXTINGUISHMENT. OBJECTIVES Module 3 Select and deploy the appropriate hose lines to accomplish fire confinement and extinguishment.
Water Supply Skill Drills.
Fire Stream and Line Selection Firefighter II. Copyright © Texas Education Agency All rights reserved. Images and other multimedia content used.
MODULE:3 FIRE CONFINMENT AND EXTINGUISHMENT. OBJECTIVES Module 3 Overview Select and deploy the appropriate hose lines to accomplish fire confinement.
Mahoney, Hannig, Fire Department Hydraulics, 2nd Ed. ©2009 by Pearson Education, Inc., Upper Saddle River, NJ Fire Department Hydraulics Chapter 8 Required.
CHAPTER 12 Copyright © 2007 Thomson Delmar Learning 12.1 Protective Systems.
Job Performance Requirement Soft-Sleeve Hydrant Connection.
Firefighter III Module B Water Supply (4-19) (4-19)
Achieving Maximum Flows The Water Triangle.... The FIRE Tetrahedron.
15 Water Supply. 15 Objectives (1 of 2) Discuss rural water supplies. Describe how portable tanks are used to supply water for firefighting. Describe.
IRRIGATION SYSTEMS. OBJECTIVES 1. Describe irrigation & its purpose 2. Explain preparation for irrigation systems 3. Calculate GPM 4. Identify & explain.
Fire Hose, Nozzles, and Streams
Pipe Fittings Purpose of Pipe Fittings  Plumbing fittings have different shapes which allow rigid straight pipe to change both direction and diameter.
Operating Fire Pumps Sugar Land Fire Department Driver/Operator—Pumper Academy Spring 2003.
Welcome To High Rise Operations ! Like The Jefferson's...
Dual Pumping Definition: An operation where a strong hydrant is used to supply two Engines by connecting the Engines intake-to-intake. The second Engine.
Water Supply (Fire Fighter I)
Fire Attack and Foam (Fire Fighter I)
Pipe Fittings.
Essentials of Fire Fighting
Harwich Fire Department
Fire Hose, Appliances, and Nozzles
Bella Vista Fire Department Procedures on Sprinkled Buildings
Presentation transcript:

Augmenting Fire Standpipe Systems

Importance of To provide independent and redundant primary or secondary water supply. Floor outlets eliminate the need to stretch hose lines from the pumper to the upper floors or deep inside a larger area building.

Principles To properly supply a standpipe system, the following principles are involved; Nozzle pressure and friction loss in the attack line, Head pressure due to elevation, Friction loss in the system, Friction loss in the supply line from the pumper to the FDC.

FD Operational Variations

Fire Department Variations: Attack and Supply lines; Some FD’s use a smooth bore or a combination (fog & straight stream) nozzle with 1 ½”, 1 ¾”, or 2” hose with lengths up to 150’, Some FD’s use 150’-200’ of 2 ½” hose with a smooth bore or a combination nozzle, Some FD’s use a short length of 3” hose off the outlet, then connect a gated wye,

Different strokes for different folks Some FD’s use 50’ of 2 ½” hose to a gated wye, supplying two 100’ lengths of 1 ½” – 2” hose with combination nozzles, One large metropolitan FD use 3 ½” hose with 3” couplings to supply the FDC, Some FD’s use LDH with Storz couplings to supply the FDC or as a temporary backup for the system,

Storz Connections

LDH used as replacement to system Reasons for use: 1.Damaged, inoperable or defective standpipe system. 2. Pressure Restricting Valves or Pressure Reducing Valves (PRV’s) that cannot be overridden. 3. Heavy volume of fire requiring greater fire flow.

Hypothetical Situation

Scenario Fire is on the eighth floor of a high rise. For the purpose of this presentation, we will assume the use of 200 ‘ of 2 ½” hose for the attack line, with a 1 1/8” smooth bore nozzle. Supply to the FDC is two individual 50’ lengths of 2 ½” hose.

Hydraulics

Attack Line using a Smooth Bore 1 1/8” nozzle with 50 psi nozzle pressure. Formula: GPM= 29.7*(D2)*Sqrt of the Nozzle Pressure. 29.7*1.265652*7.0710678= 265.8 (266 GPM)

Friction loss in attack line of 200’ of 2 ½” hose: Formula per 100’: FL= C*Q2 / 10000 2 * 2662 /10000 = 14.1512 * 2 = 28.3024 Friction Loss 200” 2 ½” hose= 28 psi

Elevation (head pressure): 5 psi per floor * 8 floors = Elevation = 40 psi.

Friction loss in the standpipe system: Friction loss in system = 25 psi. Note: With the various size of riser pipes, (4”, 5”, 6”) it is a generally accepted practice to use 25 psi friction loss in the system to make it easier to calculate desired engine pump pressure.

Friction loss in two individual 50’ lengths of 2 ½” hose supply line; Formula per 50’: FL = C*Q2 / 2 / 10000 2* 133/2/10000 = 1.7689 Friction Loss in Supply line = 2 psi

Calculations Nozzle Pressure (50 psi nozzle) 50 psi Friction loss in attack line 28 psi Elevation 40 psi Friction loss in standpipe system 25 psi Friction loss in supply line 2 psi Total 145 psi

Engine Pump Pressure = 145 psi

General Operations

To ensure adequate water: Supply the system from two pumpers, if possible, If the system has interconnected standpipe FDC, supply them both, If only one FDC present, supply 1st floor hose outlet with additional line, If building is equipped with a separate sprinkler and a standpipe system FDC, supply the standpipe first.

Supply the Standpipe 1st

If the standpipe is equipped with pressure-reducing hose valves, the valve acts as a check valve, prohibiting pumping into the system when the valve is open, A supplementary single-inlet FDC or hose valve with female threads at an accessible location on the standpipe allows pumping into that system.

Operations

Engine Co. Chauffer Test the hydrant before connecting, let Engine Officer and/or IC, know if the hydrant is not operational, thereby causing a delay in supply, Try to keep supply line to FDC not more than 100 feet, Remove kinks and sharp bends, Supply the FDC with the largest available hose, Increase pump pressure slowly to avoid pressure surges at the nozzle.

Use at least two supply lines to FDC if; more than one attack line being used from the standpipe or, indications from attack crew not enough water volume or pressure. Use the floor outlet(s) to supply the system if; leak in the piping at any point below grade allowing water to drain off, foreign matter pushed in the FDC, FDC inoperative.

FD Connection

FDC Safety consideration: Do not put your hands in the FDC to clear debris out, because it may have the presence of: broken glass, sharp metal, used drug needles.

Cans, bottles, balls, metals and drug needles have been shoved into FDC

Difficulties may be encountered with FD connections. These difficulties may include: missing caps, defective or incompatible threads, debris stuffed into the connection, tight caps, female swivels out-of-round, frozen female swivels, and clappers either broken or jammed open.

Many FDC’s are equipped with either metallic or plastic vandal proof caps, these caps are usually attached with screw eyes placed over the pin lugs on the female swivel, both metal and plastic caps are removed by striking the center of the cap with a tool, caps can also be removed by prying one of the screw eyes off the pin lug.

Some FD’s use security caps, responding via mutual aid, without the key, you will not be able to remove the cap…….. therefore, you will have to supply the system through floor outlets.

Knox registered FD ‘s should request extra keys for their mutual aid departments FDC Plug Key

Summary Test hydrant before committing, Use largest adaptable hose to supply system, Don’t put your hands into FDC, If FDC is inoperative, don’t waste time, supply system thru floor outlet(s), If supplying floor outlet(s), remember proper fittings, If your FD has security caps/plugs, make sure responding FD’s have keys provided to them.

Prepared by Thomas Bartsch Chief Fire Inspector (ret)