Engine Company Operations

Slides:



Advertisements
Similar presentations
Report # Two FFs become disoriented during fire. Report Number: Report Date: 02/23/12 14:43 Synopsis Two FFs become disoriented During fire.
Advertisements

Report # Roof Collapses on FFs During Attack. Report Number: Report Date: 01/22/ :27.
FIRE GROUND STRATEGY AND TACTICS
Strategy and Tactics with Limited Staffing
TRUCK COMPANY OPS Truck company operations are tasks that support the fire attack. Often called Support Functions The engine companies put the fire out.
Apparatus Assignments Presentation January 24, 2011.
Bungay Fire Brigade Tanker Rosenbauer Tanker on a Internationsl chassis. 2,500 gallons of water with a 1,000 GPM midship pump 1,000’ LDH.
Master Streams. Master Stream Training Available...  Awareness and Operations Training  Portable Monitors  Offensive Strategies  Defensive Strategies.
The Cleveland Load.
Blitzfire Deck Gun Ground Monitor
Snohomish County Training Officers nd Quarter.
FIREFIGHTING NOZZLES and FIRE HYDRAULICS
Nozzle Pressure. Designed Nozzle Pressures  Smooth Bore Nozzle - Handline 50 PSI  Smooth Bore Nozzle - Master Stream 80 PSI  Combination Nozzle - (all.
Fire Streams Geronimo Vol. Fire Dept.. Extinguishing Properties of Water G Water extinguishes fires by G Cooling G Remove heat from the fire G Smothering.
1 Engine Company Riding Positions Handline Stretching.
Blackwood Fire Company
Discharging CAF Streams In reality anything that will let the stuff out of the end of the hose will work. The early mantra was that a shut off gate and.
Nozzles and Fire Streams 1. Introduction Fires usually extinguished by water Water delivered using nozzles and fire streams Nozzle selection important.
Riding Assignments Presentation February 28, 2011.
Chapter 8 Portable Fire Extinguishers. Introduction Portable fire extinguishers designed to fight: –Small fires –Unusual fires –Fires that cannot be reached.
Structural Firefighting Search and Rescue
Chapter 8 Portable Fire Extinguishers. Introduction Portable fire extinguishers designed to fight: –Small fires –Unusual fires –Fires that cannot be reached.
State of Kuwait 3rd Intl Fire & Safety Conference & Expo 4-6 March 2014 Building Performance for Emergency Response Incident Examination and Tactical Response.
Pumping Apparatus Driver/Operator
HH H OUSTON H OUSTON F IRE F IRE D EPARTMENT P UMP P UMP O PERATOR O PERATOR P ROGRAM VAL JAHNKE TRAINING FACILITY.
Fire Streams SFFMA Training Objectives: –
Fire Suppression Techniques IFSTA Chapter 14
Nozzles, Fire Streams, and Foam
21 Fire Suppression. 21 Skill Drill 21-1, Fire Fighter II Coordinating an Interior Attack (1 of 4) 1.Don full PPE, including SCBA. Enter the accountability.
C L A S #4 Driver Operator Refresher Training.
Fire vs. Water Flow. What’s the best size for an “attack line?”  Maximum flow  Maximum mobility  Speed-How fast and how much  Ease of deployment and.
Salvage Operations Henderson Truck Company Manual.
HOSE HANDLING.
Instructor: Dan Braitsch
Fairfax County Fire and Rescue Department Risk Benefit Analysis Go or No Go You Make The Call! Fairfax County Fire and Rescue Department.
13 Search and Rescue. 2 Objectives (1 of 2) Define search and rescue. Describe the importance of scene size- up in search and rescue. Describe search.
Fire Department Hydraulics
MODULE:3 FIRE CONFINMENT AND EXTINGUISHMENT. OBJECTIVES Module 3 Select and deploy the appropriate hose lines to accomplish fire confinement and extinguishment.
MODULE:3 FIRE CONFINMENT AND EXTINGUISHMENT. OBJECTIVES Module 3 Overview Select and deploy the appropriate hose lines to accomplish fire confinement.
High Rise October DISPATCH E82, E83, E81, E97, E86, E95, T82, T98, R81, R83, R97, B8, B9, OSO respond to a reported structure fire at 777 W. Lake.
Engine Co. No. 52 “ Hit it, Get it, & Go Home “ Serving the Greater Mondawmin Community.
MODULE 6: PRIVATE DWELLING SIMULATIONS. OBJECTIVES Module 6 Overview Identify the unique construction factors of single-family dwellings. Recognize the.
MODULE 6: PRIVATE DWELLING SIMULATIONS. OBJECTIVES Module 6 Identify the unique construction factors of single-family dwellings. Recognize the basic problems.
Welcome to drill! Hand Tools Village Streets Know Your Trucks What Knots Backdraft Trivia Fire Basics $100 $200 $300 $400 $500.
Search & Rescue Ins and Outs Presented for use by Emory Arnold For.
21 Fire Suppression Skill Drills. 2 Objectives Apply water using the direct, indirect or combination attack. Use a large handline using the one- or two-
Search and Rescue.
State of Georgia BASIC FIRE FIGHTER TRAINING COURSE
FIRE CONTROL State of Georgia BASIC FIRE FIGHTER TRAINING COURSE.
Aerial Apparatus Operator
Attack lines and pumping. What lines to pull?  Engineers should be able to understand what hose lines are for what purpose, what GPM they operate at,
Part C: Class D Fires and Tactical Considerations.
Advanced Search and Rescue
TACTICS & STRATEGY II Fire Suppression.
AFD 20161st Quarter Training
1. 2  Dispatch information  Day of week  Time of day  Pre-incident survey  Observations  Building construction, layout  Bystanders.
FIRE COMMAND 1A Incident Command Project. SYNOPSIS: While operating at a residential structure fire, three firefighters experienced a catastrophic floor.
Types of Fire Apparatus Equipped with a Fire Pump Sugar Land Fire Department Driver/Operator—Pumper Academy Spring 2003.
 Snohomish County Training Officers  2 nd Quarter 2012 Snohomish County Training Officers 2012 Q2.
13 Search and Rescue.
Fire Ground Roles & Responsibilities On scene reports & Truck and seat assignments.
Fire Suppression (Fire Fighter II)
Master Stream Operations
Fire Attack and Foam (Fire Fighter I)
FVCC Fire Rescue Fire Control.
Primary Search and Fire Attack
Fire Hose, Nozzles, Streams, and Foam
Steps to Interior Attack
ENGINE COMPANY OPERATIONS
Bella Vista Fire Department Procedures on Sprinkled Buildings
Presentation transcript:

Engine Company Operations

Objectives: The size up 360 Tools and equipment Fire hose selection Fire streams and nozzles Fire control

SIZE IT UP It begins when the tones go off: Time of day, address, etc. Catch 3 sides, building size, layout, cars in the driveway, smoke/fire conditions. Make the routine jobs, such as pulling a handline, second nature so you can direct your attention to what’s going on with the fire building.

COME OFF WITH STUFF Radio, right TAC channel? Flashlight: it will be dark inside, even in the day time. T.I.C. – I hope the driver checked the batteries. Axe/halligan: to get in, and to get out. Pike pole/truck hook: you will end up pulling ceiling.

THE 360 Paint a picture for the DC. Hazards: pools, dogs, power drop, propane tanks, clues on the building’s contents, FIREFIGHTER EGRESS ! Fire conditions: involvement, location, where’s it going, use the imager, where are we going to enter? Location of utilities. Is quick ventilation possible to the fire room?

Fire Hose

1 ¾” – attack hose 2 ½” – offensive / defensive attack courtyard lays 3” – supply line dumping the tank highrise pack FDC for standpipe and sprinklers 5” – supply line relay pumping FDC for standpipe and sprinklers master streams 6” – capacity hookup

Which line do we pull? As the first line goes, so does the fire ! Typically the 1 ¾” with a fog nozzle at 125 GPM 150 gpm is the national standard for minimum acceptable handline flow for residential fires. 250 gpm is the national standard for minimum acceptable handline flow for commercial occupancies. The fire dictates the size of the hoseline. Think about GPM vs. BTU’s, is the fire load the same as it was 40 years ago? One pound of ordinary combustibles gives off 8,000 BTUs when burned. One pound of plastics gives off 16,000 BTUs when burned. As the first line goes, so does the fire !

Making the stretch How much hose will you need to get to the fire building? How much hose will you need once you’re in the fire building, did you catch 3 sides? For multiple floors add at least one section of hose per floor. Preplanning for courtyard and extended lays.

Positions on the hoseline The driver is generally in charge of the first 50’ The nozzle man is typically in charge of the rest. Start flaking the hose you will need inside at the front door. Bleed the line, check your pattern, check your pressure. EVERYONE check for kinks – never walk past a kinked hose! You will not see fire on every fire call ! If your not the nozzle man, if your not the lieutenant, you should be advancing hose!

Hose management is one of the most important and one of the most forgotten functions on the fire ground!

Good communication between all the members on the attack team is imperative for smooth hose advancement.

Hose streams and nozzle types

The automatic nozzle

Reach Penetration The solidbore nozzle Less nozzle reaction Less thermal layer disruption Less nozzle reaction Limited foam capabilities Poor hydraulic ventilation

Fire Control

The fog nozzle The first United States patent for a fog nozzle was granted to Dr. John Oyston in 1863. In the mid-1930s, Elkhart Brass introduced the first production periphery jet fog nozzle to the American fire service known as the "Mystery" nozzle. Despite their long history, fog nozzles were virtually unknown through the first half of the 20th century and then came Mr. Lloyd Layman . Lloyd Layman was a chief in Parkersburg, West Virginia and also in charge of the Coast Guard's wartime firefighting school at Fort McHenry in Baltimore, Maryland. In 1950 Chief Layman presented a paper entitled "Little Drops of Water" at the FDIC in Memphis, Tennessee which introduced what he termed the indirect method of attack to suppress interior building fires which used large amounts of steam for extinguishment. Most of the theory and methodology of indirect fire attack was based on his Coast Guard experiments and the February 1945 issue of Fire Engineering entitled "Coast Guard Conducts Tests on Ship Engine Room Fires“. Laymen stated, "An indirect attack should always be made from positions that will enable personnel to avoid injuries from super-heated smoke and live steam.” Layman continued by stating that "if possible and practical, an indirect attack should be made from positions outside the involved building by directing fog stream through window openings”. He discouraged the use of doorways for fog application because the outflow of scalding steam would be extremely debilitating to the nozzleman. In the 1960s and 1970s improvements in firefighter protective clothing and SCBA allowed fireman to make interior attacks and the indirect attack method went inside with them. Fog should only be used in a straight stream pattern inside.

Nozzle Facts

The Indirect attack Water converts to steam at 1,700 : 1 at 212 degrees Fahrenheit. Water converts to steam at 4,000 : 1 at 1,000 degrees Fahrenheit. Example: 10 X 10 X 8 (800 cubic foot) bedroom on fire. Wide fog at 125 GPM into the ceiling for 10 seconds. 20.83 Gallons X 1,700 = 35,411 gallons of steam 1 gallon= is approximately 0.13368 cubic feet. 35,411 gallons = 4,733 cubic feet of steam

The direct attack Applying water directly to the fuel/fire interface. Stay low and let it blow. Put the genie back in the bottle. Use as little water as possible , “pencil” technique. Strive for minimal thermal layer disruption.

Summary Pre-arrival information - what building are we responding to, warehouse or mobile home? Size up the building and read the smoke, what size and how much hose will you need to get the job done? – As the first line goes… Did you bring a halligan, axe, pike pole, truck hook, flashlight, radio, T.I.C.? Did you stack enough hose at the door while the officer is doing a 360, check the nozzle pattern, GPM setting, ensure proper pressure? Force the door, stay low let it blow, knock the fire back – don’t cause fireman soup, advance until you find the seat of the fire and extinguish it. Open the ceiling and walls checking for extension, preserve evidence for determination.