Introduction Hydrogen has been successfully used in industry for decades, but current safety codes and standards must be updated for the situations encountered.

Slides:



Advertisements
Similar presentations
Jozef Stefan Institute Plasma laboratory Ljubljana, Slovenia Chemical cleaning with neutral oxygen or nitrogen atoms Miran Mozetič Jozef Stefan Institute,
Advertisements

Review of Chemical Thermodynamics Combustion MECH 6191 Department of Mechanical and Industrial Engineering Concordia University Lecture #1 Textbook: Introduction.
A User-Friendly, Two-Zone Heat Release and Emissions Model Jeremy Cuddihy Major Professor: Dr. Steve Beyerlein.
Chapter 17 Compressible Flow Study Guide in PowerPoint to accompany Thermodynamics: An Engineering Approach, 5th edition by Yunus A. Çengel and.
Choking Due To Friction The theory here predicts that for adiabatic frictional flow in a constant area duct, no matter what the inlet Mach number M1 is,
Heating Control Devices
Some Experiments on Thermo - Acoustics of RIJKE Tube with Geometric Modifications and Forced Vorticity S.D. Sharma Aerospace Engineering Department IIT.
Laminar Flame Theory By Eng. Mohamad Okour UINVERSITY OF JORDAN MECHANICAL ENGINEERING DEPARTEMENT.
AN-NAJAH NATIONAL UNIVERSITY FACULTY OF ENGINEERING DEPARTMENT OF MECHANICAL ENGINEERING Prepared by: Wajdi abu-muhsen Khaled aamer Ahmad Al-Hunate Nabeel.
Flame Stabilization.  In order to accomplish commercial combustion, the supply velocity of the reactant mixture is desired to be extremely high; it is.
Mole Ratio of Reactants Laboratory 35 pts Name: For your laboratory report, please turn in just answers to the questions on the last slide, in addition.
Heat Conduction of Zinc Specimen Femlab Simulation Measurement Calibration Technique: Effects of Heat Loss Through Specimen Surface Area.
1 MAE 5310: COMBUSTION FUNDAMENTALS Adiabatic Combustion Equilibrium Examples September 19, 2012 Mechanical and Aerospace Engineering Department Florida.
Autonomous Vehicle Design Florida Tech AIChE 1999 P. Engel, T. McKenney, M. Mensch.
Gas Welding (Oxy-acetylene)
SAFETY AND PROCEEDURES
Hydraulics.
Forschungszentrum Jülich in der Helmholtz-Gemeinschaft E.-A. Reinecke, S. Kelm, S. Struth, Ch. Granzow, U. Schwarz* Catalytic recombiners Design studies.
Chapter 14 Chemical reactions
Presented to: International Aircraft Systems Fire Protection Working Group By: Date: April 2-3, 2008 Federal Aviation Administration Next-Generation Oil.
Chapter 15 Chemical reactions.  Any material that can be burned to release thermal energy is called a fuel.  Most familiar fuels consist primarily of.
Strategies to Achieve A Fast Cycle with High & Safe Peak Pressure in SI Engines P M V Subbarao Professor Mechanical Engineering Department Fuel Economy.
0 Copyright; 2007 IAE. All rights reserved. 2nd ICHS 11-13/9/2007 Spain Study of Hydrogen Diffusion and Deflagration in a Closed System Yuki Ishimoto 1,
Volkmar Schröder BAM, D Berlin Folie 1 International Conference on Hydrogen Safety, Pisa, September 8-10, 2005 Explosion Characteristics of Hydrogen-Air.
Sensors used in EFI (Electronic Fuel Injection)
Classification of Instruments :
5 Gas Analysis Another Rainharbor Production 1997.
Temperature Measurement
Introduction of jet engine
Centre for Fire and Explosion Studies Numerical Study of Spontaneous Ignition of Pressurized Hydrogen Release through a length of tube with local contraction.
Bilge Albayrak Çeper, S.Orhan Akansu, Nafiz Kahraman INVESTIGATION OF CYLINDER PRESSURE FOR H 2 /CH 4 MİXTURES AT DIFFERENT LOAD Dept. of Mechanical Engineering,
Parameters for the thermal decomposition of epoxy resin/carbon fiber composites in cone calorimeter 4 th ICHS Conference, September 14, 2011 D. Quang Dao.
Introduction What is a sonic orifice? How does it work? What are its uses? How is it applicable to lasers?
Pro-Science 4 th International Conference of Hydrogen Safety, September 12-14, 2011, SAN FRANCISCO, USA EXPERIMENTAL STUDY OF IGNITED UNSTEADY HYDROGEN.
Settings & Adjustments. Settings & Adjustments.
Design & Thermo Chemistry of Turbo Combustor P M V Subbarao Professor Mechanical Engineering Department Design for performance, safety and Reliability…..
Safety Determine conditions where fires and /or explosions can occur.
Figure 6 Voltage transient curve In fig.6, it is obvious that there is a significant voltage drop and transient at 1400s even though the load is not changed.
© 2014 Carl Lund, all rights reserved A First Course on Kinetics and Reaction Engineering Class 11.
FIRES AND EXPLOSION LECTURE 10.
Thermal Model of MEMS Thruster Apurva Varia Propulsion Branch Code 597.
Page 1 SIMULATIONS OF HYDROGEN RELEASES FROM STORAGE TANKS: DISPERSION AND CONSEQUENCES OF IGNITION By Benjamin Angers 1, Ahmed Hourri 1 and Pierre Bénard.
Presented to: By: Date: Federal Aviation Administration Burnthrough Test Method for Aircraft Thermal/Acoustic Insulation: Burner Replacement Investigation.
Explosion An explosion is a rapid expansion of gases resulting in a rapid moving pressure or shock wave. The expansion can be mechanical or it can be.
Outline Background Explosion Phenomena Experiments Correlation Conclusion/Summary Questions.
By Dr. Estee Yong Siek Ting
Auto Ignition, Premixed & Diffusive Combustion in CI Engines
Experimental and numerical studies on the bonfire test of high- pressure hydrogen storage vessels Prof. Jinyang Zheng Institute of Process Equipment, Zhejiang.
Chemical Equilibrium Reference: Chapter 9 Reactions Rates and Equilibrium.
Pressure Relief Devices: Calculation of Flammable Envelope and Flame Length Vladimir Molkov Hydrogen Safety Engineering and Research Centre
Kinetics and Reactor Design Kinetics and Reactor Design CHE-402 INSTRUCTOR: Dr. Nabeel Salim Abo-Ghander Chemical Reactions and Rate of Reactions Chapter.
MULTI-COMPONENT FUEL VAPORIZATION IN A SIMULATED AIRCRAFT FUEL TANK C. E. Polymeropoulos Department of Mechanical and Aerospace Engineering, Rutgers University.
Fuel-Air Modeling of Brayton Cycle P M V Subbarao Professor Mechanical Engineering Department Exact Modeling of Cycle is a first step for Energy Conservation…..
Heat Exchangers Results Josué Ortiz #57703 Prof: Eduardo Cabrera Me
Proportional-Integral-Derivative (PID) Temperature Control & Data Acquisition System for Faraday Filter based Sodium Spectrometer Vardan Semerjyan, Undergraduate.
Misuse of Combustible Gas Meters Supervisor Training 1/11/08.
Date of download: 6/23/2016 Copyright © ASME. All rights reserved. From: Design of Bioimpedance Spectroscopy Instrument With Compensation Techniques for.
Compressible Flow in Nozzles Thermal Engineering Lab ME-4111 Professor: Eduardo Cabrera Damian Luna Yetziel Sandoval – Alberto Gonzales –
Damian Luna Yetziel Sandoval – Alberto Gonzales – 80546
Compressive Flow in Nozzles
Problem 1 Diesel fuel (C12H26) at 25 ºC is burned in a steady flow combustion chamber with 20% excess air which also enters at 25 ºC. The products leave.
Low energy nuclear reaction occurring in hydrogen-loaded nickel wire
Date of download: 10/17/2017 Copyright © ASME. All rights reserved.
超臨界CO2在增強型地熱系統儲集層中取熱之研究-子計畫三 CO2在增強型地熱系統取熱模型之建構及效能分析
Fire Study in Multiple Compartments
Height and Pressure Test for Improving Spray Application
ME 475/675 Introduction to Combustion
Design Space for Combustor
Les Shirvill1, Mark Royle2 and Terry Roberts2 1Shell Global Solutions
Presentation transcript:

Introduction Hydrogen has been successfully used in industry for decades, but current safety codes and standards must be updated for the situations encountered during public use of hydrogen fuel cell vehicles. Hydrogen/air mixtures have been found to ignite anywhere between 4%- 75% hydrogen by volume 1. Under normal leak conditions, this is an acceptable risk because the low molecular weight of hydrogen allows quick dissipation below flammability limits. When the leak is confined to a small heated area, the ignition propensity drastically increases since the hydrogen cannot dissipate quickly. A hydrogen leak within a fuel cell vehicle allows for the possibility of trapped gas coming into contact with heated metal surfaces. Certain metals can act as a catalyst to ignite hydrogen/air mixtures, which can be sustained through surface reactions. A system has been designed to determine the critical ignition conditions for hydrogen/air mixtures within heated metal tubes to eventually develop an ignition envelope to aid in the improvement of fire safety standards for hydrogen fuel cell vehicles. Test System Design The test system is designed to flow a specific mixture of hydrogen, oxygen, and nitrogen gas into a heated metal tube to determine the ignition temperature. As seen in figure 1 below, the metal tube is heated by the power supply, and the temperature of the tube is measured at three points using thermocouples and recorded using a National Instruments data acquisition system. Increasing the voltage across the tube increases the temperature by the resistance of the metal. The pressure regulators are used to control the backpressure of the sonic nozzles to set the gas flow rates. The solenoid valves are controlled using a LabView program to switch the flow to allow only nitrogen into the tube to aid in cooling and extinguish self sustaining flames. Elizabeth Ehrke Department of Physics, Case Western Reserve University, Cleveland, OH Research Advisor: Chih-Jen Sung Department of Mechanical and Aerospace Engineering, Case Western Reserve University Catalytic Ignition Conditions of Hydrogen in a Tubular Reactor Conclusions and Future Work The system can accurately determine ignition conditions for various flow rates and equivalence ratios. This system will be used to test the catalytic ignition propensity of several metal materials that are likely to come into contact with leaking hydrogen gas. The affect of residence time and equivalence ratio on ignition temperature will be investigated to determine critical ignition conditions. This data can then be used to help develop improved codes and standards to increase the fire safety of hydrogen fuel cell vehicles. Acknowledgements I would like to thank the NIST Fire Safety Laboratory for funding this project. I would also like to express my gratitude to Kyle Brady for his help on the design and construction of the system. References 1.J.L. Alcock, L.C. Shirvill, R.F. Cracknell, “ Compilation of Existing Safety Data on Hydrogen and Comparative Fuels,” Deliverable Report EIHP2, (2001) Abstract Widespread use of hydrogen fuel cell vehicles can potentially decrease national energy use and reduce harmful emissions. One of the main obstacles to public release is the development of validated safety codes and standards. A tubular reactor system was developed to test the ignition propensity of hydrogen/air mixtures for fire safety applications. The simulated hydrogen/air mixture enters a heated metal tube, which acts as a catalyst to ignite the hydrogen at a specific temperature. The mixture composition and flow rate can be varied to test the affect of equivalence ratio and residence time on ignition propensity. Initial testing shows that ignition occurred in a.4 mm diameter platinum tube with varied flow parameters. The temperature of ignition is unique to the specific flow rate and mixture composition. Future testing using this system will record complete ignition profiles for multiple materials, which can be used to identify high-risk leak situations and improve safety standards for hydrogen-powered devices. Testing A flow rate and equivalence ratio ( ϕ ) were set using the linear fits of each gas to specify the backpressure. The flow was allowed to stabilize then the tube temperature was incrementally increased by increasing the voltage until ignition was observed. Ignition is observed by a large sudden increase in temperature due to exothermic surface reactions. Three thermocouples recorded temperature with number 1 being closest to the tube entrance. Initial tests of the tubular reactor show that ignition has occurred in a 14 cm long,.4 mm diameter platinum tube. Variation of the flow rate and equivalence ratio resulted in different ignition locations and temperatures. Sonic Nozzle Calibration Sonic nozzles are used to set the specified flow rate and equivalence ratio ( ϕ ). They allow low flow rates, which are needed due to the small diameter tubes used in the system. Small tubes are used to prevent gas phase reactions, which release too much heat and could melt the tube, connections, or thermocouples. The flow through the nozzle is choked, so only changes in backpressure will affect the flow rate through the nozzle. Each nozzle was calibrated using a bubble meter which measures the flow volume over time. As expected, the flow rates for hydrogen, oxygen, and nitrogen were linearly proportional to the nozzle backpressure. Volumetric flow rate Q of a choked flow through a nozzle is determined by (1) where P o is the backpressure, A * is the throat area, ρ is the gas density, T o is the gas temperature, R is the specific gas constant, and γ is the ratio of specific heats. The theoretical and experimental pressure dependence of the hydrogen sonic nozzle is shown in figure 2 below. The linear fit is well within the error on the calibration data. The calibration is consistent with theory when adjusting for the assumptions made. The linear fit is used to determine the backpressure for the desired flow rate. On/Off Valve Pressure Regulator and Sonic Nozzle H2H2 O2O2 N2N2 Chamber Pressure Gauge Thermocouple Solenoid Valve Power Supply Computer Figure 1: Schematic of test system including flow structure and tubular reactor Figure 2: Pressure dependence plot of hydrogen flow rate through choked nozzle including experimental calibration, linear fit, and theoretical data plot Figure 3: Plots of the applied voltage and temperature of the platinum tube at three locations with respect to time. Two different trials are shown with ϕ =.4 and.5. The arrows indicate manual voltage increases to increase the tube temperature. The red circles indicate the spontaneous ignition temperature. Results and Discussion Catalytic ignition was observed for multiple test parameters. Figure 3 shows the temperature and voltage plots of two tests with ϕ of.4 and.5. The arrows show the manual voltage increases. The red circles show the ignition temperature. The large temperature spikes do not correspond to a voltage increase, which indicates catalytic ignition through surface reactions. Ignition occurs at about 900 K for ϕ =.4 and about 1000 K for ϕ =.5. The temperature spike is the flame front moving past thermocouple 1 to the entrance of the tube. After the voltage is turned off the temperature stays elevated, which indicates that the flame is self sustaining. The ignition plots and their differences demonstrate the system is functioning correctly, and it is possible to characterize the critical ignition conditions for a range of initial parameters.