Kara Hoffman Mark Oreglia Students: David Billmire Steve Olmschenk.

Slides:



Advertisements
Similar presentations
MSD1 Senior Design Project- Oxygen Gas Sensor
Advertisements

Radiopharmaceutical Production Target Foil Characteristics STOP.
Bulk Micromegas Our Micromegas detectors are fabricated using the Bulk technology The fabrication consists in the lamination of a steel woven mesh and.
KT McDonald Target Studies Weekly Meeting July 10, Power Deposition in Graphite Targets of Various Radii K.T. McDonald, J. Back, N. Souchlas July.
Tungsten wire & VISAR Goran Skoro 24 October 2008.
Semiconductor Light Detectors ISAT 300 Foundations of Instrumentation and Measurement D. J. Lawrence Spring 1999.
M. Palm, CERN1 Performance test of ACEM-detector (Aluminum Cathode Electron Multiplier) Marcus Palm AB-ATB-EA.
Directional Detectors and Digital Calorimeters Ed Norbeck and Yasar Onel University of Iowa For the 25 th Winter Workshop on Nuclear Dynamics Big Sky,
Slide 1 Diamonds in Flash Steve Schnetzer Rd42 Collaboration Meeting May 14.
Design and test of a high-speed beam monitor for hardon therapy H. Pernegger on behalf of Erich Griesmayer Fachhochschule Wr. Neustadt/Fotec Austria (H.
Kara Hoffman The University of Chicago Enrico Fermi Institute and the MuCool Collaboration May 14, 2004 A brief history and first results.
TOF at 10ps with SiGe BJT Amplifiers
Radiation Detection and Measurement II IRAD 2731.
4/11/2006BAE Application of photodiodes A brief overview.
Topic 28: Direct Sensing 28.1 Sensing devices
3/26/2003BAE of 10 Application of photodiodes A brief overview.
LASER BEAM MACHINING BY S.PREMKUMAR.
KT McDonald MAP Spring Meeting May 30, Target System Concept for a Muon Collider/Neutrino Factory K.T. McDonald Princeton University (May 28, 2014)
1 cm diameter tungsten target Goran Skoro University of Sheffield.
 A GEANT4-based simulation was performed of the production target, solenoid, selection channel, and spectrometer.  The acceptance was found to be 8.3x10.
Design of the Photon Collimators for the ILC Positron Helical Undulator Adriana Bungau The University of Manchester Positron Source Meeting, July 2008.
Beijing, Feb 3 rd, 2007 LEPOL 1 Low Energy Positron Polarimetry for the ILC Sabine Riemann (DESY) On behalf of the LEPOL Collaboration.
Kara Hoffman The University of Chicago Enrico Fermi Institute.
Target & Capture for PRISM Koji Yoshimura Institute of Particle and Nuclear Science High Energy Accelerator Research Organization (KEK)
Status of Hybrid target R&D at KEK-LINAC T.Takahashi Hiroshima University LCWS/ILC10 Beijing Collaborators: V. Strakhovenko O. Dadoun, R. Chehab, A.Variola,
A Comparison between Electroluminescence Models and Experimental Results D. H. Mills 1*, F. Baudoin 2, G. Chen 1, P. L. Lewin 1 1 University of Southampton,
Study of Pion Capture Solenoids for PRISM H.Ohnishi AB M. Aoki C, Y. Ajima A, N. Fukasawa AD, K. Ishibashi B, Y. Kuno C, T. Miura A, K. Nakahara C, T.
Muon Detector Jiawen ZHANG Introduction The Detector Choices Simulation The structure and detector design The Expected performance Schedule.
Progress in UCSD Chamber Simulation Experiments – Initial Results from Fast Thermometer Farrokh Najmabadi Sophia Chen, Andres Gaeris, John Pulsifer HAPL.
Status of Beam loss Monitoring on CTF3 Results of Tests on LINAC and PETS as R&D for TBL Anne Dabrowski Northwestern University Thibaut Lefevre CERN CTF3.
Luminosity Monitor UKNF Meeting 7 June 2010 Paul Soler, David Forrest Danielle MacLennan.
The ZEUS Hadron-Electron-Separator Performance and Experience Peter Göttlicher (DESY) for the ZEUS-HES-group Contributions to HES Germany, Israel, Japan,
8 July 1999A. Peisert, N. Zamiatin1 Silicon Detectors Status Anna Peisert, Cern Nikolai Zamiatin, JINR Plan Design R&D results Specifications Status of.
Neutron detection in LHe ( HMI run 2004) R.Golub, E. Korobkina, J. Zou M. Hayden, G. Archibold J. Boissevain, W.S.Wilburn C. Gould.
At the HERA collider in Hamburg an experiment (ZEUS) has been built to study electron-proton collisions. For the near future an upgrade of this experiment.
Apollo Go, NCU Taiwan BES III Luminosity Monitor Apollo Go National Central University, Taiwan September 16, 2002.
October 2005 Qweak Collaboration Meeting Detailed Design of Shield House and Collimators wrt Backgrounds Yongguang Liang Just getting started – will probably.
DØ Central Tracker Replaced with New Scintillating Fiber Tracker and Silicon Vertex Detector The DØ Central Detector Upgrade The DØ Detector is a 5000.
Review of synthesis of super heavy elements: reactions, decays and characterization. Experimental Setup of MASHA. Results of first experiments. study.
X-ray microanalysis in the electron microscope
Possible calibration methods for the final LXe calorimeter A. Papa 02/11/
FSC Status and Plans Pavel Semenov IHEP, Protvino on behalf of the IHEP PANDA group PANDA Russia workshop, ITEP 27 April 2010.
Schottky Barrier Diode One semiconductor region of the pn junction diode can be replaced by a non-ohmic rectifying metal contact.A Schottky.
LHCb Vertex Detector and Beetle Chip
DIGITAL CAMERAS THE IMAGE SENSORS. CCD: Charged Coupled Device CMOS: Complementary Metal Oxide Semiconductor The differences between these two sensors.
Update on the HBD Craig Woody BNL DC Meeting May 11, 2005.
GRAN SASSO’S HADRON STOP Temperature’s behaviour under specified beam conditions Barbara Calcagno.
Measurements of Intense Proton Beams using Optical Transition Radiation Vic Scarpine, Fermilab TIPP 2011 Chicago, IL June 10, 2011.
Infrared Laser Test System Silicon Diode Testing 29 May 2007 Fadmar Osmić Contents: Setup modifications new amplifier (Agilent MSA-0886) new pulse generator.
 Heat travels from hot to cold  The bigger the temperature difference the faster the rate of transfer.
Present status of production target and Room design Takashi Hashimoto, IBS/RISP 2015, February.
Measurement of coating mechanical loss Junko Katayama, K.Craig, K.Yamamoto, M.Ohashi ICRR 0.
Upgrade of the MEG liquid xenon calorimeter with VUV-light sensitive large area SiPMs Kei Ieki for the MEG-II collaboration 1 II.
Application of photodiodes
Solid-State Cameras for LHC instrumentation
FCAL R&D towards a prototype of very compact calorimeter
Radiation hardness tests of GaAs and Si sensors at JINR S. M
National Research Center” Kurchatov Institute”
Graeme Stewarta, R. Batesa, G. Pellegrinib, G. Krambergerc, M
ROX sensor packaging and mounting scheme for use on dilution STM sample plates Ben MacLeod Jan
PIN DIODE.
GOVT WOMEN ENGINEERING COLLEGE AJMER
Update on GEp GEM Background Rates
CMS ECAL Calibration and Test Beam Results
LHCb VErtex LOcator For precision measurements of CP-violation at CERN (GENEVE) HALF of DETECTOR Si strip detector Read-out electronics Secondary vacuum.
GEANT Simulations and Track Reconstruction
Performance test of ACEM-detector (Aluminum Cathode Electron Multiplier) Marcus Palm AB-ATB-EA M. Palm, CERN.
P2 - Physics Circuits.
Gain measurements of Chromium GEM foils
CLIC luminosity monitoring/re-tuning using beamstrahlung ?
Presentation transcript:

Kara Hoffman Mark Oreglia Students: David Billmire Steve Olmschenk

Bolometric Materials We ’ ve Tested Cernox brittle – won’t flex with window “cernox” (we’re not allowed to know what that really is) is deposited on thick sapphire backing bare chip difficult to work with expensive greatest sensitivity Nickel same geometry as a strain gauge with polyimide encapsulation also made by measurements group works right out of the box Graphite “homemade”- either painted colloidal carbon or cut by hand from a thick foil we are trying to develop some more precise milling techniques for a more uniform response, but crude ones work

Janis continuous flow tunable temperature cryostat Sample Holder

Our current laboratory setup Xe flashlamp Laser diode photodetector lenses cryostat filter Flashlamp- high power, long time constant We also just received a new YAG laser. Light sources electronics

0.8 V 0.8 V 10 ms First results at LH2 temperature 0.8 V 0.8 V 20 ms Nickel Carbon Signal from a xenon flashlamp. Note that the peaks have a different polarity. Carbon’s electrical resistivity increases with temperature, while nickel’s decreases. Time constants are decreased with respect to previous measurements made at room temperature.

Origin of secondary peak? Simulated here for electrons (not photons) in the Nickel bolometer. Large amount of energy deposited in polyimide encapsulating material, owing to it ’ s thickness. Calculated temperature rise in kapton is on the same order of magnitude as the Nickel. Polyimide introduces an additional time constant.

10 ms 10V 10V Cernox First results at LH2 temperature (continued) We had proof of principle, both at room temperature, and cryogenic temperatures, and we had materials that had an adequate thermal response at 20K. We needed to demonstrate that it would work for a charged particle beam (muons?). Note different scale, and this was with a lower intensity photon beam to prevent saturating the amplifier.

Energy deposited (per particle) in Nickel film by various beams GeV MeV protons 20 MeV electrons 200 MeV muons Nickel film of cm thickness Amount of energy deposited by 200 MeV muons is roughly the same as for 20 MeV electrons Fortuitously, there is a 20 MeV electron beam available at Argonne Anything sensitive to 200 MeV muons will also be sensitive to MeV protons

1 cm Disadvantage: e ’ s scatter easily & cryostat introduces a lot of material

Transfer line Flanges w/ multipin connectors Radiation shield Cu cold finger Quartz windows Cryostat Blueprint (not to scale)

Beamtest: First Try Hz short pulse duration: ~10 ’ s ns /pulse

Silicon Diode Temperature Sensor +/ K sensitivity down to 2 K Problem 1: We don ’ t know the temperature Thermometer failed sometime during the first set of measurements made at cryogenic temperatures. In retrospect a thermometer based on a p-n junction was perhaps not the best choice. It later came back to life (after beam test was over, of course). Signal or background? One way to gain insight is to look for thermal dependence (i.e. change in time constant). Signal or background? One way to gain insight is to look for thermal dependence (i.e. change in time constant). Worst case scenario: take data at 4K.

Full beam at 4.2 K… …with 2” inch steel block in front. We later found that the connection with the electronics was poor.

5.97 mm 3.18 mm active area GEANT3 Simulation Idealized beam from a point source 10 cm in front of window Actual beam profile in plane of front window quartz window Optical hole in cold finger Simulation Problem 2: Beam profile is larger than active area of the bolometer

Beamtest: Try Again copper block with 1/8 ” hole added to mask off beam and shield the thermometer also modified electronics elongate pulses to lower instantaneous current

T=300K T=20K?? Thermometer died again At 20 K we expect a temperature rise of ~2K. Results are consistent with expectations.

Available thermometric films Note different horizontal scales! Nickel: cm thick Graphite: cm thick Platinum: cm thick the thicknesses shown for nickel and graphite are the actual thicknesses used in our lab Note that additional thickness doesn ’ t = greater sensitivity, since additional thermal mass is added We haven ’ t tested platinum (we are now tackling the problem of how to mill a foil) but it ’ s shown for comparison because (with it ’ s higher Z) it has a very high dE/dx = more sensitivity

Idea: Separate the noise response from the thermometric component by aligning two bolometers with oppositely signed signals back to back.

Beamtest: 3 rd try? We’ve learned a lot about our setup -or- Hindsight is 20/20 Ideally, the beam should be contained within the active area of the bolometer. Since quartz scatters the beam, the copper aperture may be only part of the solution. Replace quartz windows with a material that ’ s more transparent to electrons. Work on beam alignment. Use two different bolometers with oppositely signed response to separate signal from noise. Purchase thermometer more suitable for these conditions.

We have proof of principle, and several materials that will work at 20 K. Our calculations/simulations indicate that we can make bolometry work in a charged particle beam. Our “ prototypes ” however, provide a much smaller target than in a cooling channel, and our cryostat introduces a lot of material. Beam tests are consistent with expected results, but inconclusive, however we have ideas on how to resolve this (shortly).