SQUID NMR Measurements in nEDM experiment -- how to get a big signal & how to operate SQUIDs in High Voltage Environments Chen-Yu Liu.

Slides:



Advertisements
Similar presentations
5 Current Field Measurement 5.1Alternating Current Field Measurement 5.2Direct Current Potential Drop 5.3Alternating Current Potential Drop.
Advertisements

Magnetic fields R&D update B. PlasternEDM November 2007 Collaboration Meeting Results from prototype studies of a 1/6-scale B 0 coil with Results from.
Magnetic shielding calculations and also Petr Volegov Andrei Matlashov Michelle Espy LANL, P-21, SQUID team Igor Savukov.
September 23, 2004Univeristy of Twente1 Superconducting Gravity Gradiometry State of the Art.
WHAT IS SUPERCONDUCTIVITY?? For some materials, the resistivity vanishes at some low temperature: they become superconducting. Superconductivity is the.
The electron EDM search in solid ferroelectric Eu 0.5 Ba 0.5 TiO 3 Alex Sushkov Steve EckelSteve Lamoreaux.
Page 1 © J.Paul Robinson - Purdue University Cytometry Laboratories BMS 631 – LECTURE 8 Flow Cytometry: Theory J.Paul Robinson Professor of Immunopharmacology.
What are we measuring with EEG and MEG James Kilner.
Superconducting Quantum Interference Device SQUID C. P. Sun Department of Physics National Sun Yat Sen University.
Faraday’s Law  produces an induced current Lenz’s Law: Induced current is in a direction so as to produce a B opposing the change in magnetic flux, 
1 Progress Report on A New Search for a Permanent Electric Dipole Moment of the Electron in a Solid State System 13 th SUSY Conference, Durham UK, July.
Briefing about SQUIDGeneral Applications Our Application to NDT in Aluminum Plates.
Progress report on the HV-SQUID Compatibility Test
Magnetic Field Lines for a Loop Figure (a) shows the magnetic field lines surrounding a current loop Figure (b) shows the field lines in the iron filings.
Detection of 3He with SQUIDs. Experimental parameters For B=300 Gauss The expected signal is 220 fT (specific geometry is taken into account), while the.
Nov PHYS , Dr. Andrew Brandt PHYS 1444 – Section 003 Lecture #20, Review Part 2 Tues. November Dr. Andrew Brandt HW28 solution.
Electromagnetic shielding of the SQUID in the nEDM Experiment: Bolts and Nuts Andrei Matlashov, Michelle Espy, LANL, P What happens when SQUID is.
MICE CM30 Magnetic Shielding Update Mike Courthold 6 th July
DHB, nEDM Collab. Mtg, 15/16 Apr 04 UIUC Test System (Beck, Chandler, Hertzog, Kammel, Newman, Peng, Sharp, Williamson, Yoder; Blackburn, Kenyon, Thorsland)
The International Workshop on THIN FILMS APPLIED TO SUPERCONDUCTING RF AND NEW IDEAS FOR PUSHING THE LIMITS OF RF SUPERCONDUCTIVITY M. Valentino, Padova-Italy,
Chapter 22 Magnetism and Its Uses.
1 Paolo Falferi - ET WG2 meeting - Glasgow, 22/7/2010 Actuator magnetic noise measurement and possible developments Paolo Falferi CNR-FBK Trento and INFN.
A Portable Ultrasensitive SERF Atomic Magnetometer for Biomagnetic Measurements R Wyllie, 1 Z Li, 2 R Wakai, 3 N Proite, 1 P Cook, 1 T Walker 1 1 – Department.
HTc-SQUID Beam Current Monitor at the RIBF T. Watanabe*, N. Fukunishi, M. Kase RIKEN Nishina Center S. Inamori, K. Kon TEP Corporation IBIC September.
Michelle Espy SQUID NMR Signal Outline Overview of SQUIDs in EDM: present thinking - experimental design ideas - expected signal,
Ampere’s Law The product of can be evaluated for small length elements on the circular path defined by the compass needles for the long straight wire.
1 W.Ootani ICEPP, University of Tokyo MEG experiment review meeting Feb , PSI W.Ootani ICEPP, University of Tokyo MEG experiment review meeting.
Lecture 14 Magnetic Domains Induced EMF Faraday’s Law Induction Motional EMF.
Background from the NIST test The pencil neutron beam (1 mm 2 ) with intensity about 7000 n/sec The beam was completely absorbed in the beam stop with.
Monday, Apr. 17, 2006PHYS , Spring 2006 Dr. Jaehoon Yu 1 PHYS 1444 – Section 501 Lecture #20 Monday, Apr. 17, 2006 Dr. Jaehoon Yu Transformer Generalized.
New Low-Frequency GW Detector with Superconducting Instrumentation
SQUID Performance in a HV Environment
It is sometimes difficult to find the polarity of an induced emf. The net magnetic field penetrating a coil of wire results from two factors.
Chapter 22 Magnetism and its uses Characteristics of Magnets Greeks experimented more than 2000 years ago with a mineral that pulled iron objects.
HV-SQUID Compatibility Test Study the SQUID performance in a HV environment. Study the HV breakdown –in superfluid under pressure. –using different materials.
雜訊測量及分析實驗. Sources of electronic noises The two most commonly encountered types of noise are thermal noises and shot noises. Thermal noise arise from.
DOE 2/11/05 #1 EDM R&D Progress Steve Lamoreaux, Los Alamos Co-spokesperson for the EDM Project for presentation to The Department of Energy Cost & Schedule.
Tuesday April 19, PHYS , Dr. Andrew Brandt PHYS 1444 – Section 02 Lecture #18 Tuesday April 19, 2011 Dr. Andrew Brandt Chapter 29 Lenz Law.
3/17/2014 PHYS , Dr. Andrew Brandt 1 PHYS 1442 – Section 004 Lecture #15 Monday March 17, 2014 Dr. Andrew Brandt Chapter 21 Generator Transformer.
22.7 Source of magnetic field due to current
Electron EDM Measurement using a Paramagnetic Crystal Chen-Yu Liu and S. Lamoreaux (P-23) M. Espy and A. Matlachov (P-21) 6/2/03.
C. Lu, K.T. McDonald RPC Connections October 27, RPC Module Signal and HV Connections (October 27, 2008) Changguo Lu, Kirk T. McDonald Princeton.
Optical Receivers Theory and Operation
Ultra-low Field Nuclear Magnetic Resonance Measurements with SQUIDs
Study of T 1 relaxation time A proposal to test T 1 using a dilution fridge and SQUID NMA at Royal Hollow University,London.
Monday, April 23, PHYS , Spring 2007 Dr. Andrew Brandt PHYS 1444 – Section 004 Lecture #19 Monday, April 23, 2007 Dr. Andrew Brandt Inductance.
EDM Engineering Issues General Mechanical Considerations EDM Cryostat Plan D ANSYS EMAG Calculations ANSYS MECH Calculations 3 June ‘03 J. Boissevain.
Electric Energy Notes.
Conceptual Design of the Neutron Guide Holding Field Christopher Crawford, Yunchang Shin University of Kentucky nEDM Collaboration Meeting
EDMEDM LANL Review of EDM Cost and Schedule Jan Boissevain, P-25 February 11, 2005, Los Alamos National Laboratory EDM Reference Design Tour of the Reference.
The force on a current-carrying wire A magnetic field exerts a force on a single moving charge, so it's not surprising that it exerts a force on a current-carrying.
A Portable Ultrasensitive SERF Atomic Magnetometer for Biomagnetic Measurements R Wyllie, 1 Z Li, 2 R Wakai, 3 N Proite, 1 P Cook, 1 T Walker 1 1 – Department.
The Fate of Silicon Technology: Silicon Transistors Maria Bucukovska Scott Crawford Everett Comfort.
The Different Types of Inductors and Their Affecting Factors
Patterns of Fields: Gauss’ Law, Ampere’s Law M&I Chapter 22.
1 The control of the Virgo mirrors is realized using coil-magnet actuators Can this technique be used in ET, from room to cryogenic temperatures? Is the.
SQUID applications in the SNS nEDM Experiment
WHAT IS SUPERCONDUCTIVITY?? For some materials, the resistivity vanishes at some low temperature: they become superconducting. Superconductivity is the.
Neutral current is zero
Magnetization, AC Loss, and Quench in YBCO Cables”
PHYS 1444 – Section 02 Lecture #19
Mike Sumption, M. Majoros, C. Myers, and E.W. Collings
MiniGRAIL “Extreme Make-over” Giorgio Frossati
PHYS 1444 – Section 003 Lecture #21
The force on a current-carrying wire
Precision Beam Monitors for COSY Jülich
MEG fundamentals.
Arian Lalezari 22 September 2004 Modeling in Applied Math
Noise I Abigail Firme.
Creepage and Clearance for MVDC Power Electronics
Presentation transcript:

SQUID NMR Measurements in nEDM experiment -- how to get a big signal & how to operate SQUIDs in High Voltage Environments Chen-Yu Liu

He 3 Spin Measurement ● How big is the magnetic field signal? – 2.76x gauss on the edge of the cell, where x is the He3 concentration. – X= → field signal = 2.76 fT – With a pick-up coil of 10cmx20cm, F= 1.5×10 -8 gauss-cm 2 =70m F 0. ● We have the option of gradiometer & magnetometer.

50 µ F 0 (coil)→0.5µ F 0 (SQUID) with 1% coupling efficiency 13.5 m F 0 (coil)→135µ F 0 (SQUID) with 1% coupling efficiency Magnetometer/gradiometer=270

Understanding the Magnetic Field Profile in the geometry of nEDM experiment ● A detailed magnetic field modeling is required to guide us in positioning and designing the pick-up coils. ● Available resources: – A Matlab finite element code in P-21 group. (S/C. Shield, no F/m shield) – Ansys: 3D finite element analysis – Radio (mathematica): 3D (no S/C shield) – Poisson Superfish: 2D – Other Commercial Codes

Vibration B 0 =1mG Assume a position fluctuation (due to vibration) of 1µm over a 10 cm length. The flux fluctuation into a magnetometer pick-up coil of 10cmx20cm is A gradiometer can cancel the DC field to 10 4, and the vibrational coupled flux is reduced to 10m F 0. Comparable to the He3 signal! Challenging!

Options on pickup coils – Wire-wound magnetometer ● Coils can be made as big as you want. (big signal!) ● Subject to all environmental noise and vibration induced ac noise. – Wire-wound gradiometer ● 1:100 balancing between 2 opposite wound coils. ● Coupled to a SQUID outside the field region. – On-chip PhotoLithography gradiometer ● best matching 1:10,000 ● area is limited by the size of substrate (Si wafer). (Smaller signal, but better immunity to vibrational noise and RFI.) ● Convinent, commercially available.

R 1 =2cm R 2 =2cm R 3 =  (R 1 2 +R 2 2 )=3.42cm L G =700nH for 10  m dia. wire =500nH for 100  m dia. Wire (Nb superconducting wire) Electrodes and Magnetic flux pick-up coils (planar gradiometer) for eEDM experiment Common mode rejection of external uniform B field and fluctuations. Enhancement of sample flux pick-up. + _ 0 5” 2.5” CMRR = 238  0.4% area mismatch

Lead Box Star Cryoelectronics 1165 DC SQUID Closed Pb box, containing a SQUID (solder sealed) To pickup coil To PFL circuit box, Outside the cryostat SQUID in Pb box Connection box (RF shielded) HV lines Star Cryoelectronics 1165 SQUID: Fails after a few thermal cycles. Current lock mode built-in Quantum Design DC SQUID, Model 50: Very sturdy Flux lock mode

1/f corner of SQUID (QD-50)

First-Order Planar SQUID Gradiometers with Long Baseline Robin Cantor, J. Ad Hall, Andrei. N. Matlachov and Petr L. Volegov ● Developed by Star Cryoelectronics. ● “…. The white flux noise of the improved gradiometer with 3.6 cm baseline is as low as 2.4 µ Ѱ 0 / √ Hz(rms), and the magnetic field sensitivity referred to one pickup loop is 0.63 nT/ Ѱ 0. This results in a magnetic field gradient noise of 0.42 fT/cm- √ Hz.” ● “ All of the gradiometers cold easily be operated without magnetic shielding in a typical laboratory environment without losing lock using only a Mylar film with a thin Au coating for rf shielding. Operated unshielded, the rms flux noise at 10kHz tended to be roughly two times higher.” ● Could make it 4 times bigger.

SQUID Friendly Environment ● RF shielded environment – Faraday Cage: absolutely necessary – Superconductor: only necessary around the SQUID package. ● With a samll gradiometer, S/C shield is not required. – All current, voltage leads going into the field region should be low pass filtered.

Noise in SQUID measurements ● Predictable Noise – Johnson noise (white) from nearby conductors ● Electrodes (Material still yet to be decided). ● Ferromagnetic Shields ● Excessive noise – Vibrations. – Micro-discharge in dielectrics under HV (White or pink?) ● More importantly, it imposes a critical practical issue of how to keep SQUID operational with RFI produced by micro-discharges? – Leakage current. (Continuous current flow or pulsed?)

SQUID Noise Spectrum in eEDM experiment -MACOR electrode with AeroDag coating -Pb shield 2 layers of Pb superconducting foil Vibrational peaks are suppressed. Background ~ 2x Intrinsic SQUID noise Baseline: 27.5  0 /rtHz Baseline: 5.8  0 /rtHz Vibrational peaks A proper S/C shield reduces the vibrational noise in eEDM experiment. However, this will not solve the vibrational noise in nEDM experiment, because the B field is internal.

SQUID under High Voltage Insufficient RF shield? Limits the application of field to only 3kV/cm! Effects of RFI due to micro-discharges???

Leakage current I B~ fT (contribution from 1 side of the wall) at 5cm away from the cell. This is comparable to the If the gradiometer is right in the center of symmetry, there is no field inside the pickup coil. If the leakage current is making fraction of a turn from one electrode to the other, there could be finite contribution into the pickup coil. The size of the signal depends on the exact current path. The gradiometer configuration does not cancel this field produced by local source.

SQUID R&D plan ● SQUID sensors & Pickup coil test (P-21) – Reliability tests (thermal cycles) & intrinsic noise measurements. – Sensitivity characterization of various designs of pickup coil (full size model). – Mitigate the vibration issue through proper design of a gradiometer. – Help with low concentration He 3 NMR measurements (with Tito). ● Johnson noise measurement of electrode and cell material (P-21, IU) ● HV compatibility test (IU) – Same technical issues faced in the eEDM experiment.

HV-SQUID Compatibility Tests at IU ● Scaled down HV cell – Study breakdown properties of various electrode materials of interests, with different degree of surface polish. – Effect of pressurization on breakdown in liquid helium in normal state and superfluid state. – Leakage current in different cell materials of interests. ● SQUID – Study effects of (micro-) discharge on SQUID performance. – Mitigate RFI ● by, for example, placing the pickup coil inside a thin-metal foil faraday cage with a price of increased Johnson noise. ● Low pass filter – Measure leakage current with SQUID. – Attempt to detect trapped flux inside superconducting shields??? – Possibility of using SQUID as electron detector???