ELECTRIC DRIVES Ion Boldea S.A.Nasar 1998 Electric Drives.

Slides:



Advertisements
Similar presentations
5. PERFORMANCE CHARATERISTICS OF IM
Advertisements

Stator Voltage Control
ENERGY CONVERSION ONE (Course 25741)
ELECTRIC DRIVES Ion Boldea S.A.Nasar 1998 Electric Drives.
AC DRIVES There are two type of AC motor Drives :
ELECTRIC DRIVES Ion Boldea S.A.Nasar 1998 Electric Drives.
9.11. FLUX OBSERVERS FOR DIRECT VECTOR CONTROL WITH MOTION SENSORS
ELECTRIC DRIVES Ion Boldea S.A.Nasar 1998 Electric Drives.
Machine Transformations
ELECTRIC DRIVES Ion Boldea S.A.Nasar 1998 Electric Drives.
Power System Fundamentals
Two-pole,3-phase,wye-connected,salient-pole synchronous machine
Electric Drives FEEDBACK LINEARIZED CONTROL Vector control was invented to produce separate flux and torque control as it is implicitely possible.
Modeling of Induction Motor using dq0 Transformations
ECE Electric Drives Topic 4: Modeling of Induction Motor using qd0 Transformations Spring 2004.
SYNCHRONOUS MACHINES SUBMITTED BY: Ms. APOORVA KANTHWAL
ECE Electric Drives Topic 3: Induction Motor Modeling -
ELECTRIC DRIVES Ion Boldea S.A.Nasar 1998 Electric Drives.
SYNCHRONOUS GENERATORS
ECE Electric Drives Topic 17: Wound-Field Synchronous
Lesson 33 AC Generators.
Induction motor1 AC Machine Stator ‘a’ phase axis ‘b’ phase axis ‘c’ phase axis
Synchronous Generator
ELECTRICAL ENGINEERING: PRINCIPLES AND APPLICATIONS, Third Edition, by Allan R. Hambley, ©2005 Pearson Education, Inc. Chapter 17 AC Machines.
Introduction to Electrical Machines
16.11s June 2006 L s Notes for Lecture 4 Analysis of Induction Machines June 15, 2006 J.L. Kirtley Jr.
Module G1 Electric Power Generation and Machine Controls
Synchronous Induction
Designed by Mr. H.K. Schrage - Swedish Engineer in 1911.
Induction Motor Why induction motor (IM)? –Robust; No brushes. No contacts on rotor shaft –High Power/Weight ratio compared to Dc motor –Lower Cost/Power.
Topic 8: Simulation of Voltage-Fed Converters for AC Drives Spring 2004 ECE Electric Drives.
Fundamentals of Electromagnetics and Electromechanics
Induction Motors.
Dynamic Model of Induction Machine MEP 1522 ELECTRIC DRIVES.
Induction Machine The machines are called induction machines because of the rotor voltage which produces the rotor current and the rotor magnetic field.
Chapter 5. Synchronous Machines.
AC Machines Fundamentals. Introduction Synchronous machines: Motors and generators whose magnetic field is supplied by a separate dc power supply. Induction.
EET 221 Synchronous Machines Rafiqi.
Slide 1Fig 33-CO, p Slide 2Fig 33-1, p the basic principle of the ac generator is a direct consequence of Faraday’s law of induction. When.
Chapter 6 Synchronous Motors
Induction Motors Equations, Performance, Electrical Equivalent Circuits.
Magnetic field due to an electric current
BASIC ELECTRICAL TECHNOLOGY DET 211/3
Dynamic Model of Induction Machine. WHY NEED DYNAMIC MODEL? In an electric drive system, the machine is part of the control system elements To be able.
SMJE 2103 Synchronous Generator. Scope of discussion 1)Construction 2)Rotation speed 3)Generated voltage 4)Equivalent circuit 5)Power and Torque 6)Testing.
Lesson 12a: Three Phase Induction Motors
THREE-PHASE INDUCTION MOTOR
Equations, Performance, Electrical Equivalent Circuits
Electric Motors and Generators
Electric Machine Induction Motor
Module G1 Electric Power Generation and Machine Controls
AC and DC motors.
Dr. Zainal salam; Power Electronics and Drives (Version 2),2002, UTMJB
Wind turbine technology
ELECTRICAL ENGINEERING: PRINCIPLES AND APPLICATIONS, Third Edition, by Allan R. Hambley, ©2005 Pearson Education, Inc. Chapter 17 AC Machines.
Advanced Power Systems
Energy Conversion and Transport George G. Karady & Keith Holbert
Energy Conversion and Transport George G. Karady & Keith Holbert
Utilisation of Electrical Energy
SINGLE PHASE INDUCTION MOTOR.
Induction Motor Drives
TOPIC: ROTATING MAGNETIC FIELD DEPT: EEE
TOPIC: ROTATING MAGNETIC FIELD DEPT: EEE
EET 306 Synchronous Machines
Summary of Material on Electric Drives Covered on July 24, 2019
Electric Machine Design Course
Induction Motors (Lecture 1&2)
Electric Machine Design Course
Electric Machine Design Course
Electric Machine Design Course
Presentation transcript:

ELECTRIC DRIVES Ion Boldea S.A.Nasar 1998 Electric Drives

8. INDUCTION MOTORS FOR DRIVES 8.1. THE STATOR AND ITS TRAVELING FIELD Figure 8.1. Cross section of an induction motor with two poles (8.1) Electric Drives

Figure 8.2. The m.m.f. and airgap flux density of phase a (8.2) (8.3) (8.6) (8.8) (8.9) (8.11) Electric Drives

8.2. THE CAGE AND WOUND ROTORS ARE EQUIVALENT Figure 8.3. Induction motor rotors a.) cage - type rotor b.) wound rotor Electric Drives

8.3. SLOT SHAPING DEPENDS ON APPLICATION AND POWER LEVEL Figure 8.4. Stator or wound rotor slots a.) for low power (semiclosed slots) b.) for high power (open slots) Electric Drives

a.) semiclosed - round for low power and variable frequency motors Figure 8.5. Rotor slots a.) semiclosed - round for low power and variable frequency motors b.) closed - for low noise or high speed motors c.) semiclosed with moderate skin effect and starting torque - constant frequency d.) semiclosed with high skin effect for high starting torque - constant frequency e,f.) double cage - for superhigh starting torque - constant frequency g.) for high speed inverter - fed motors Electric Drives

Figure 8.6. Three phase induction motor with equivalent wound rotor 8.4. THE INDUCTANCE MATRIX Figure 8.6. Three phase induction motor with equivalent wound rotor (8.12) (8.13) (8.14) Electric Drives

The inductances may be now assembled into the so called matrix inductance : (8.18) where: Electric Drives

8.5. REDUCING THE ROTOR TO STATOR (8.19) (8.20) (8.21) (8.22) So the new inductance matrix is similar to that in (8.18), but with . Electric Drives

8.6. THE PHASE COORDINATE MODEL GOES TO 8th ORDER (8.23) (8.24) (8.25) (8.26) (8.27) Using (8.24) in (8.23) - with qer variable in time in any case - we obtain: (8.28) where: (8.29) Electric Drives

The motion equation are: (8.33) (8.30) (8.31) (8.32) The motion equation are: (8.33) Electric Drives

8.7. THE SPACE PHASOR MODEL (8.34) (8.35) (8.36) (8.37) (8.38) Electric Drives

With definitions (8.37) - (8.38), equations (8.35) - (8.36) become: (8.41) With definitions (8.37) - (8.38), equations (8.35) - (8.36) become: (8.42) (8.43) If to (8.42) - (8.43) we add similar equations for phases b, br and c, cr equation (8.23) becomes: (8.44) (8.45) (8.46) Electric Drives

The torque should be calculated from (8.42) with the above notations: (8.48) (8.49) (8.50) (8.51) (8.52) (8.53) The torque should be calculated from (8.42) with the above notations: Electric Drives

We may now decompose in plane the space phasors along two orthogonal axes d and q moving at speed wb [5]: (8.55) (8.56) Electric Drives

[P(qb)] is the Park transformation: Also from (8.49) - (8.50) and (8.47): (8.57) [P(qb)] is the Park transformation: (8.58) The inverse of Park transformation is: (8.59) Electric Drives

Example 8.1. The space phasor of sinusoidal symmetric currents. Consider three symmetrical sinusoidal currents and show how their complex space phasor in time through 6 instants. Give a graphical description of this process in time. Solution: The three phase currents may be written as: (8.61) The space phasor in stator coordinates is, (8.37),: (8.62) with (8.63) (8.62) becomes: (8.64) Electric Drives

The position of the space phasor for is shown in figure 8.7. Figure 8.7. The space phasor of sinusoidal three phase currents Electric Drives

8.8. THE SPACE PHASOR DIAGRAM FOR ELECTRICAL TRANSIENTS The space phasor model equations (8.51) - (8.53) may be represented on a space phasor diagram in the d - q plane with axes d and q rotating at speed wb = w1 (figure 8.8). Let us consider . Figure 8.8. The space phasor diagram of induction motor valid for transients (for steady d/dt = 0) in synchronous coordinates (cage rotor: ) Electric Drives

For this case the torque expression (8.54) becomes: (8.68) d/dt = j(w1 - wb). (8.66) Also for steady state of rotor flux the rotor flux equation (8.52) becomes: (8.67) Only for (short - circuited, cage, rotor) the rotor current and flux space phasors are orthogonal to each other. For this case the torque expression (8.54) becomes: (8.68) Electric Drives

8.9. ELECTRICAL TRANSIENTS WITH FLUX LINKAGES AS VARIABLES (8.69) (8.70) (8.71) equations (8.51) - (8.53) become: (8.72) (8.73) Electric Drives

and as variables; random speed (wb) coordinates. with (8.74) While ts, tr are the stator and rotor time constants, ts’ and tr’ are transient time constants of rotor and stator.The structural diagram corresponding to (8.72) - (8.73) is shown on figure 8.9. Figure 8.9. Structural diagram of induction motor with stator and rotor flux and as variables; random speed (wb) coordinates. Electric Drives

8.10. COMPLEX EIGEN VALUES FOR ELECTRICAL TRANSIENTS Equations (8.72) - (8.73) imply a second order complex - variable system with only two complex eigen values corresponding to the determinant: (8.75) The complex eigen values from (8.75) depend on the reference system speed wb and on rotor speed wr, but their real part is, in general, negative suggesting attenuated periodic response.[4,6] Example 8.2. For an induction motor with the data rs = 0.5W, rr = 0.60W, Ls = Lr = 0.08H, Lm = 0.075H, p = 2pole pairs calculate the complex eigen values for constant speed, in synchronous coordinates (w1 = 2p60) for n = 0 and n = 1800 rpm. Electric Drives

Solution: The value of wb = w1 = 2p60 rad/s. s, ts’, tr’, Ks, Kr are now calculated from (8.71) - (8.74): (8.76) (8.77) Also (8.78) Electric Drives

Now we rewrite (8.75) in a canonical form: (8.79) (8.80) For n = 0 (8.81) For n = 30rps (1800rpm): (8.82) Electric Drives

8.11 ELECTRICAL TRANSIENTS FOR CONSTANT ROTOR FLUX (8.83) Using (8.83) in (8.73): (8.84) It is more convenient to use synchronous coordinates for equations (8.72): (8.85) Equations (8.84) - (8.85) lead to a simplification in the structural diagram of figure 8.9. as the derivative term in the rotor disappears (figure 8.10). Electric Drives

Figure 8.10. Structural diagram of induction motor with constant rotor flux and speed in synchronous coordinates (wb = w1) Electric Drives

8.12. STEADY STATE: IT IS D.C. IN SYNCHRONOUS COORDINATES Steady state means in general that the three phase voltages are symmetric and sinusoidal: ; i = 1, 2, 3 (8.86) The voltage space phasor in random coordinates is: (8.87) with (8.86): (8.88) For steady state: (8.89) Consequently: (8.90) Electric Drives

It is obvious that for steady state the currents in the model have to have the voltage frequency, which is: . Once again for steady state we use (8.51), with d/dt = as inferred in (8.66). Consequently from (8.51): (8.91) In the flux equations (8.52) - (8.53) we may separate the main (airgap) flux linkage : (8.92) (8.93) Equations (8.91) - (8.93) lead to the standard equivalent circuit of figure 8.11. Electric Drives

The torque expression (8.54) with (8.91) and Vr0b = 0, yields: (8.94) Figure 8.11. Space phasor steady state equivalent circuit of induction machine The torque expression (8.54) with (8.91) and Vr0b = 0, yields: (8.94) Electric Drives

Consequently the electromagnetic torque Te is: (8.96) From (8.92): (8.95) Consequently the electromagnetic torque Te is: (8.96) Using the equivalent circuit of figure (8.11) and (8.95) we may obtain the conventional torque expression: (8.97) with (8.98) Electric Drives

8.13. NO LOAD IDEAL SPEED MAY GO UNDER OR OVER CONVENTIONAL VALUE w1 The no load ideal speed (slip S0) corresponds to zero torque, that is, (8.91), zero rotor current: (8.99) Only for short - circuited rotor windings (or passive impedance at rotor terminals) ( ) the ideal no load slip S0 = 0 and wro = w1. When the induction machine is doubly fed ( ) the ideal no load slip is different from zero and the no load ideal speed is, in general,: (8.100) Example 8.3. For steady state, calculate the stator voltage, stator flux, current, power factor, torque of an induction motor at 10% ideal no load (synchronous) speed w1 and S = 0.02. The motor data are: rs = 0.5W, rr = 0.6W, Ls = Lr = 0.08H, Lm = 0.075H, lr0 = 0.8Wb, w1 = 2p60 rad/s, p = 2 pole pairs, Vrb = 0 (cage rotor). Electric Drives

Solution: First we have to calculate the initial conditions, which are implicitly steady state. Let us use synchronous coordinates: (8.101) So (8.102) The torque (Te) is, (8.96),: (8.103) From (8.72) - (8.73) with d/dt = 0 and Vrb = 0 we may now calculate the stator flux : (8.104) Notice that the motor parameters are as in example 8.2 and thus tr’ = 0.01614s, ts’ = 0.01937s, Ks = Kr = 0.9375, s = 0.1211. (8.105) Electric Drives

Let us consider the d axis along the rotor flux and thus = . Now from (8.72) with we may find the stator voltage : (8.106) The motor phase voltage (r.m.s. value): (8.107) The stator current is obtained from (8.69): (8.108) Electric Drives

The rotor space phasor is (8.95): (8.109) The amplitude of the stator current . The results are illustrated by the space phasor diagram in figure 8.12. The power factor angle j1 is: (8.110) Finally cosj1 = 0.633. Figure 8.12. Steady state space phasor diagram in synchronous coordinates (wb = w1): d.c. quantities Electric Drives

Figure 8.13. Induction motor energy conversion Example 8.4. Loss breakdown A high efficiency induction motor with cage rotor has the data: rated power Pn = 5kW, rated line voltage (rms) VL = 220V (star connection), rated frequency f1 = 60Hz, number of pole pairs p = 2, core loss (Piron) = mechanical loss Pmec = 1.5% of Pn, additional losses padd = 1%Pn, stator per rotor winding losses pcor/pcos = 2/3, rated efficiency hn = 0.9 and power factor cosjn = 0.88. Calculate all loss components, phase current (rms), then rated slip, speed, electromagnetic torque, shaft torque and stator current (as space phasors). Solution: The loss breakdown diagram of the induction motor is shown in figure 8.13. Figure 8.13. Induction motor energy conversion Electric Drives

The phase current In (rms) is: (8.112) The input power Pin is: (8.111) The phase current In (rms) is: (8.112) The total losses are: (8.113) Consequently: (8.114) (8.115) So (8.116) (8.117) (8.118) Electric Drives

The rotor winding loss pcor is: (8.122) and thus the rated slip is: The electromagnetic power Pe is the active power that crosses the airgap: (8.119) (8.120) (8.121) The rotor winding loss pcor is: (8.122) and thus the rated slip is: (8.123) The rated speed nn is: (8.124) The shaft torque Tn is calculated directly from mechanical power Pn: (8.125) Finally the amplitude of the stator current , in synchronous coordinates (d.c. quantities) are: (8.126) Electric Drives

8.14. MOTORING, GENERATING, A.C. BRAKING The equivalent circuit for steady state (figure 8.11) shows that the active power in the rotor (the electromagnetic power Pe), is: (8.127) This expression is valid for the cage rotor (Vrb = 0). Motoring mode is defined as the situation when the torque has the same sign as the speed: (8.128) For generating the torque is negative (S<0) in (8.127) but the speed is positive: (8.129) The generator produces braking (Te < 0, wr > 0) but the energy transfer direction in the motor is reversed. The energy is pumped back into the power source through the stator. Electric Drives

We may synthesize the results on operation modes as in table 8.1. Braking is obtained when again (Te > 0, wr < 0) (or Te < 0, wr > 0) but still the electromagnetic power is positive: (8.130) We may synthesize the results on operation modes as in table 8.1. Table 8.1. Operation modes (cage rotor) Electric Drives

The torque slip (speed) curve is shown in figure 8.14. (8.131) (8.132) The torque slip (speed) curve is shown in figure 8.14. Figure 8.14. Torque - speed curve of induction motors for constant voltage and frequency Electric Drives

8.15. D.C. BRAKING: ZERO BRAKING TORQUE AT ZERO SPEED For moderate braking requirements d.c. braking is commonly used in modern electrical drives. To calculate the d.c. braking torque we redraw the space phasor equivalent circuit in figure 8.11, but with a d.c. stator current source space phasor in figure 8.15. Figure 8.15. Equivalent circuit for d.c. braking - stator coordinates - in space phasors; steady state Electric Drives

The electromagnetic torque is still computed from (8.94): (8.134) with (8.135) Finally: (8.136) The peak torque is obtained for wrk: (8.137) and its value is: (8.138) Electric Drives

Figure 8.16. D.c. braking torque of induction motors (8.139) The torque speed curve for d.c. braking is shown in figure 8.16. Notice also that the rotor kinetic energy is dumped into the rotor resistor and that for zero speed the braking torque is zero. Also above wrk (which is fairly small in high efficiency motors) the torque is again rather small. Figure 8.16. D.c. braking torque of induction motors Electric Drives

8.16. SPEED CONTROL METHODS Variable speed is required in many applications. It has to be performed at high energy conversion rates. The no load ideal speed wr0 is ((8.100) with (8.99)): (8.140) Evidently for the cage rotor = 0 and thus or (8.141) w2 is the frequency of the rotor current (or of - rotor P.E.C.). There are three essential methods to vary speed by varying the no load ideal speed (as the rated slip is small) as suggested by (8.140): stator frequency f1 variation; pole number (2p) changing; wound rotor supply (or rotor frequency f2 variation). Electric Drives

constant (controlled) rotor flux (lr) vector control; Stator frequency control is far more frequently used especially for wide speed control range. However the level of flux depends on the current in the machine. Especially on the magnetisation current (8.142) Consequently it is crucial to control Im properly to avoid excessive magnetic saturation, while varying frequency f1. V1/f1 - scalar control; constant (controlled) rotor flux (lr) vector control; constant (controlled) stator flux (ls) - vector control. Here only the torque / speed curves obtainable with the above methods are given. Notice that in all these cases the P.E.C. voltage supplying the induction motor is voltage limited with the maximum voltage reached at base speed wb. Electric Drives

8.17. V1/f1 TORQUE - SPEED CURVES V1/f1 control means that: (8.143) (8.144) Figure 8.17. Torque / speed curves for (V1/f1 control) a.) V1/f1 dependences b.) Te/wr curves Electric Drives

8.18. ONLY FOR CONSTANT ROTOR FLUX TORQUE - SPEED CURVES ARE LINEAR (8.146) Figure 8.18. Torque - speed curves for constant rotor flux lrb = ct. up to base frequency w1b; constant voltage and variable frequency above w1b Electric Drives

8.19. CONSTANT STATOR FLUX TORQUE - SPEED CURVES HAVE TWO BREAKDOWN POINTS (8.147) (8.148) This expression has extreme (critical) values for: (8.149) (8.150) Electric Drives

(8.151) Figure 8.19. Torque - speed curves for constant stator flux amplitude ls up to w1b and constant voltage above w1b Electric Drives