Cleaning H50/52 Blowers The condition of the blower motor has a direct affect on the operation of an H50/52 fryer.

Slides:



Advertisements
Similar presentations
AIRCONDITIONER ERROR CODES
Advertisements

Understanding the Alternator
Basic Small Engine Maintenance and Repair Projects
MANUAL TRANSMISSION ELECTRICAL. OBJECTIVES n Diagnose electrical problems by logic and symptom description. n Perform troubleshooting procedures using.
Current Meter Maintenance Model OSSPC1 Hydrographic Training Bandar Seri Begawan Brunei August 2010.
“Enerpak” Units » Propeller Type Fan » Size 100 – 400 MBH » 80% Thermal Efficiency » Natural or LP Gas » 10 Year Warranty on Heat Exchanger, Burners,
1 Gas Heat THERMOSTATS. 2 Thermostat A thermostat is a control that is activated by changes in the surrounding air temp.
Refrigerators.
Permission granted to reproduce for educational use only © Goodheart-Willcox Co., Inc. Chapter 12 Air Delivery Systems.
Heating Control Devices
HIGH EFFICIENCY WATER HEATERS - Residential Gas - Polaris ®
Equipment Use Review  What lab equipment is used for handling a hot beaker?  What lab equipment would be used to hold a piece of metal in a flame? 
Laboratory procedures for the Bunsen burner.. Objectives To absorb proper safety technique with the Bunsen burner. To familiarize you with the Bunsen.
FAULT MESSAGES:- Action To Be Taken
Gas Furnace Controls Part 4.
Welcome to Autoescorts Please Press F5 to view & Press Enter to change Slides.
IGNITION SYSTEM SERVICE. TESTING AND REPAIR l Evaluate the symptoms –Narrow down possibilities l Pinpoint to a specific engine system –Compression –Fuel.
Charging System Service
Table of Contents Safety Circuits Induced Draft Motors Gas Valves
1.4b Charging System 1. Charging System Function of the charging system 2 Convert mechanical energy into electrical energy Recharge battery Provide higher.
Iris Range : «Unconventional» conventional detectors.
ELECTRONIC FUEL INJECTION COMPONENTS
Troubleshooting Electric Control Devices
On/Off Temp Holiday Select Fan Air clean Operation Auto SwingRoom Temp Week Select SET/CLR Hour MIN Timer Program Set Fan Speed Jet Cool Cancel RESET E_Heater.
Starter System Service Chapter 33 Page 439. Service Begins with Checking System Check the battery first –Voltage should be 12.6 and while the starter.
CHARGING SYSTEM Major Parts Battery                                               Alternator Regulator.
1 214 Motors Part II. 2 Permanent Split Capacitor Motors In order to increase the starting torque of a motor you can insert a capacitor in series with.
Burners TRAining CEntre. RESIDENTIAL GAS BURNERS R D B R D B series GOALS: KEEP STRONG OUR POSITION ON RESIDENTIAL GAS BURNERS DEDICATED TO OEM’s MARKET.
Air Handler Terminology
Air Handler Terminology
First, let’s review the structure and use of a breadboard.
© Goodheart-Willcox Co., Inc. Permission granted to reproduce for educational use only.
Tempest Blower SECTION: Tools and Equipment ISSUED: REVISED: ##-####
Troubleshooting Small Engine Systems Jason Spurlin 4/10/02 Virginia Tech Edited by the CTAE Resource Network February 2011.
Understanding the                                                                                                                                                                                                                          
Company LOGO SMART Board Troubleshooting Power and Connections.
Why Maintenance Tasks are Important Produced by Joe Marchese.
1 HVAC122 - Gas Gas Valves. 2 Solenoid Gas Valves The solenoid gas valve is the simplest of all valves. This valve has an electrical magnetic coil which.
Oil Heat Oil Burner Parts.
Student Handout Packet – Page A7
Avoid _____________ _____________ _____________ _____________ _____________ _____________.
HOUSE WIRING Final Review. Electricity Electricity = flow of electrons Conductor= electricity passes thru easily - Metal, water, person Insulator = restricts.
We apply 120 VAC to the HM Unit (Remember to check polarity!) Our primary step down T/X provides power to terminal “X” and “COM” on the ignition control.
Vertical Pump Motor Manifold Upgrade. VPMM Replaces Existing Pumps, Motors, Relief Valves, Check Valves, Discharge Filters, Pump Running Pressure Gauges,
Maintenance of, or to Change a faulty MCB (motor control board) 2010 models onwards.
Unit 13 Oil-Burning Equipment
Diagnosing & Repair Late model vehicles (OBD II) can be checked with the scan tool for the following problems: Crankshaft Position Sensor Crankshaft Speed.
Starting System Circuit Operation and Testing
Understanding the Alternator
Automotive Heating And Air Conditioning
E2 Motors and Motor Starting
“Good morning, and welcome to Burner Tutorials!
AC Repair & Furnace Repair - Tips To Consider
Ignition Systems Overview
Furnace Cleaning and Some Tips for Repairs
Subsystems of EFI Chapter 22 Lesson 2.
Most Effective Methods to Clean the Dirty Airflow Mass Sensor.
Essential Tips to Perform Ignition System Checks.
SB Packing Automatic Downpuller Power Unit
CONTROL BOX RMG
350, 350XL ¾”- 1”.
FIGURE 24-1 The two horns on this vehicle were finally located under the front bumper. They were not visible until the vehicle was hoisted.
Error codes for split systems
PLC Front Panel.
Automotive Technology Principles, Diagnosis, and Service
AUTOMATIC AIR-CONDITIONING SYSTEM OPERATION
Presentation transcript:

Cleaning H50/52 Blowers The condition of the blower motor has a direct affect on the operation of an H50/52 fryer.

The blower is easily removed and cleaned. Four bolts hold it in place.

The wiring must be disconnected.

Once removed from the fryer, the blower must be disassembled.

Oil trapped in the fan causes it to hold dust and debris, which erodes its efficiency.

The squirrel- cage fan is readily cleaned at a sink, however, the motor must be protected from water.

Apply a degreasing cleaner to the fan...

…and to the inlet ports on the motor side of the fan.

The blower housing should also be cleaned with degreaser

Rinse both components, reassemble and reinstall

The condition of the blower affects the quality of the flame and the quality of the flame is measured by the fryer. A poor flame can lead to ignition failures. The flame should be adjusted to produce a rich orange burn.

Air enters the blower through adjustable vanes on the side. A rich orange flame can be achieved by adjusting the vane and watching the flame change from blue to orange.

Earlier model H50/52 fryers used a Kooltronics blower, however, the adjustment is the same.

The current produced by the flame is also an indicator of the quality of the burn. An AC signal from the module is grounded by the flame, producing measurable microamps.

A meter capable of reading microamps is placed in series in the spark module with the common lead to the ignitor terminal and the red connected to the white lead from the ignition module. With the fryer out of melt and in full burn, the microamps should rise from 3.5 to 6.5 uA in about a minute.

Faulty flame readings can result from a dirty flame sensor. The device is easily cleaned with emory paper.