March 2005 International Medcom 707-823-0336 www.medcom.com How to Use the Inspector.

Slides:



Advertisements
Similar presentations
January 2012International Medcom, Inc How to Use the Radalert 100.
Advertisements

January 2012International Medcom, Inc How to Use the Inspector Alert.
QUARTERLY SCBA Practice Part 1
SECTION 11 LEVEL B SUIT OUT. SECTION 12 AIR MONITORING.
ELITE XR THERMAL IMAGER
DP-IR Detecto-Pak Infrared
Olympus DM-20 Digital Voice Recorder We’re high tech now, baby!
Components: Sansa Clip Mp3, earbuds, USB cable, Quick Start Guide.
(PLEASE SWITCH TO THE SLIDE SHOW MODE)
TLA. Replacing The Battery On the Back of the pager press in this button while moving the door away from the pager, then lift up. On the Back of the pager.
Training for Radiation Pagers Training for Radiation Pagers Berkeley Nucleonics Corporation 2955 Kerner Blvd. San Rafael, CA
M100 M100 Overview Preparation & Testing. M100 Overview  The M100 is a computerized tabulator that optically reads then counts and totals specially designed.
Personal Surveyor 200 (PS200) Series
N105 Lindquist Center Documentation This document includes: 2 - Teacher Station Control Panel 3 - Student Table Controls 4 - Lighting Controls 5 - Faculty.
 Description of PressurePro System  Identify system components  Display and Operational Modes  Sensor alerts  Checking of tire pressures  Manual.
In this presentation you will:
Detects Alpha (α) Beta (β) Gamma (γ) and X-Ray (χ) Alpha – radioactive particles. Stopped with paper Beta – particles and low energy waves. Stopped with.
Radiation Safety Course Radiation Monitoring Heath de la Giroday Dispensing Chemist Radiation Safety Officer.
March 2006 Berkeley Nucleonics Corporation How to Use the palmRAD 907.
© 2008 Masimo Corporation Includes a review on Carbon Monoxide Poisoning For Emergency Responders V.8 1 May 2011 Monitoring CO Poisoning with the Rad-57.
Nuclear Radiation Basics. Copyright © 2011International Medcom Contents What is Radiation? What is Radiation? Instruments that Measure Nuclear.
Familiarization and Operation
Clean Air Box Usage & Care CABs RAMs CO Monitors.
MySOS User Guide.
MSA - ALTAIR 4X Gas Meter.
Radiological Equipment - Advanced. Objectives For each radiation detection instrument: −Perform advanced operating procedures −Become familiar with software.
AccuMax Multi-Point Injection Mechanics
M40M Multi-Gas Monitor. Checking instrument: A. Checking instrument: 1.Turn the instrument on by pressing the power button on the control face panel for.
Introduction ► Scope:- Service Diagnostics Routines can use for XXL, Side by Side products with STEALTH user interface with single evaporator fan product.
Paver System Five Control Box Overview Aug 2009 Control Box Overview Paver System Five.
MEK-6400 series Technical seminar Sensors adjustment.
SOLDIER BIOLOGICAL CHEMICAL COMMAND (SBCCOM)
International Medcom How to Use the Radalert 50 March 2005 International Medcom
Control Panel Overview. Purpose of the Control Panel  The Control Panel allows you to choose what you want your projector to display on the screen.
© 2008 Masimo Corporation RAD-57 EMS Carry Case Lightweight: 13 oz. Small: 6.2” x 3.0” x 1.4” Portable: operates on 4 “AA” batteries Supplied with high-visibility,
Model 1621M Trainer’s Guide. General Overview Model 1621M is a Geiger Meuller based Personal Radiation Detector (PRD) Complies with ANSI Used for.
Connecting and Configuring Clickers. InterWrite PRS - Clicker 2-line LCD Display See data entered Confirmation answer received Variety of question types.
Scout Pro Training Introducing the Scout Pro Portable Balance: 7 Models From 200g x 0.01g to 6000g x 1g 5 Application Modes Optional USB or RS232 Interface.
GCS 300 System Operation Application – Level 1.
HPT001.xxx Rev. x Page 1 of xx TP-1 TVAN Technical Training Health Physics (RADCON) Initial Training Program ACADs (08-006) Covered Keywords Detectors,
TI – 83 Plus1 A Quick Reference Presentation for AMSTI Year 1 Training.
1 THE VICTOR READER WAVE ● Plays DAISY books as well as music and books on MP3 or audio CD ● Powerful navigation features ● Go directly to any page number.
1. Enter service mode and scroll to the Calibrate menu option What is Rider Calibration? This feature enables a rider to calibrate the Watt sensor before.
Cypress-Fairbanks I.S.D. 04/04/05 SLAT Ablenet Switch Latch and Timer Training Module.
Detecting Instruments (For Contest Work Only) MSA Passport Personal Alarm.
Programming 101 The Common Palette Content provided by Connor Statham (9 th Grade Student) Formatting by Shannon Sieber.
Click the pictures to advance to next slide Use the left arrow to go back.
HPT001.xxx Rev. x Page 1 of xx TP-1 TVAN Technical Training Health Physics (RADCON) Initial Training Program HPT001.xxx Rev. x Page 1 of xx TP-1 TVAN Technical.
Geiger counter NTHU General Physics Laboratory
InnoSys Park Brake Tool Master Control Panel Screens Revision A, 12Dec /12/20071.
Spring Hill Assembly1 InnoSys Park Brake Tool Master Control Panel Screens 1 3-Mar-2008.
Last updated: 6/6/2016www.alto-shaam.com Halo Heat Training Cook & Hold OvensHolding Cabinets.
NN-CS596S Steam Microwave Oven. NN-CS596S Oven Specification.
All Freezer Advance. When the Freezer is first supplied with power or if a power outage occurs, the display will indicate this by flashing the temperature.
MSA Passport  Personal Alarm Combustible gases and vapors Oxygen enriched Oxygen deficient Specific Toxic gases Alarm levels are set at the factory.
To Respond to Questions ANS: Your Class’s Name ANS: A Received ANS: A Enter Answer 1. Enter the answer and press send. 2. Once received you can answer.
Detects Alpha (α) Beta (β) Gamma (γ) and X-Ray (χ) Alpha – radioactive particles. Stopped with paper Beta – particles and low energy waves. Stopped with.
Dry contact sensor HDL-MSD04.40 HDL-MSD08.40.
How to Fix HP BIOS Application Selected Is Corrupt or Missing Problem?
सोलर पॅनेलचा उपयोग करुन रीचर्जेबल टॉर्च बनवणे.
McCrometer Nano Board Test Procedure
C140 Navigation System Upgrade Manual
Alcohol Screening Program
How to Use the Inspector Alert
First Quartile- Q1 The middle of the lower half of data.
2. ATP INITIALIZATION PLACE ATP SWITCH TO “1” OR “NORMAL” POSITION A
724 Temperature Calibrator
C140 Navigation System Upgrade Manual
Nellcor™ Bedside SpO2 Patient Monitoring System, PM100N - Home use
Presentation transcript:

March 2005 International Medcom How to Use the Inspector

March 2005International Medcom This presentation is intended to give the user a brief overview of how to operate the Inspector. For a complete understanding of this instrument please refer to the operating manual.

March 2005International Medcom What the Inspector Does The Inspector measures the rate of the following types of nuclear radiation The Inspector measures the rate of the following types of nuclear radiation Alpha Alpha Beta Beta Gamma Gamma X-radiation X-radiation The Inspector measures the amount of nuclear radiation in The Inspector measures the amount of nuclear radiation in Counts per minute (CPM) Counts per minute (CPM) Counts per second (CPS) Counts per second (CPS) MilliRoentgens per hour (mR/hr) MilliRoentgens per hour (mR/hr) MicroSeiverts per hour MicroSeiverts per hour (µSv/hr) (µSv/hr)

March 2005International Medcom How to Turn On the Inspector Turn the Inspector on by moving the lower switch from to or. Turn the Inspector on by moving the lower switch from Off to On or Audio. --The Inspector is measuring radiation but there is no audio. On--The Inspector is measuring radiation but there is no audio. --The Inspector is measuring radiation, and beeping with each count of radiation that is detected. Audio--The Inspector is measuring radiation, and beeping with each count of radiation that is detected. When the Inspector is first turned on it does a 3 second system check, displaying all the indicators and numbers. When the Inspector is first turned on it does a 3 second system check, displaying all the indicators and numbers. After the system check is finished the Inspector shows the current level of nuclear radiation. After the system check is finished the Inspector shows the current level of nuclear radiation. The Inspector updates its visual display once every three seconds. The Inspector updates its visual display once every three seconds.

March 2005International Medcom How to Select the Operating Mode Move the upper switch to Move the upper switch to Total/Timer (counts per minute or counts per second) CPM/CPS (counts per minute or counts per second) or (milliRoentgen per hour or microSeivert per hour). mR/hr or µSv/hr (milliRoentgen per hour or microSeivert per hour). In mode the Inspector starts totaling the counts it registers, and the numeric display is updated each time a count is registered. In Total mode the Inspector starts totaling the counts it registers, and the numeric display is updated each time a count is registered. The mode is the easiest to understand for the layperson. The CPM mode is the easiest to understand for the layperson.

March 2005International Medcom How to Switch the Mode To switch the mode from to and from to : To switch the mode from mR/hr to µSv/hr and from CPM to CPS: Turn the Inspector off. Turn the Inspector off. Hold down the button on the end panel while turning the Inspector on. Hold down the + button on the end panel while turning the Inspector on. Scroll through the numbers on the screen until you get to. Scroll through the numbers on the screen until you get to 2. Press the button on the end panel. Press the CAL button on the end panel. Use the or button on the end panel to toggle between settings. Use the + or - button on the end panel to toggle between settings.

March 2005International Medcom What is Background Count? The background count is the normal level of nuclear radiation that is occurring at a given time and place. The background count is the normal level of nuclear radiation that is occurring at a given time and place. Some sources of background radiation are: Some sources of background radiation are: The sun The sun Minerals in the earth Minerals in the earth Residual radiation from nuclear testing and other man made sources Residual radiation from nuclear testing and other man made sources Nuclear radiation is a naturally occurring phenomenon. When the Inspector is on it is normally measuring the background count. Nuclear radiation is a naturally occurring phenomenon. When the Inspector is on it is normally measuring the background count. A user should determine the normal background count in case abnormal levels of nuclear radiation occur. A user should determine the normal background count in case abnormal levels of nuclear radiation occur. The mesh screen covers the end window of the Geiger-Mueller sensor.

March 2005International Medcom How to Determine the Average Background Count Turn the Inspector, and put it in Total mode. Turn the Inspector On, and put it in Total mode. Set the switch on the end panel to. Set the Timer switch on the end panel to Set. Press the button until the display reads 00:10 (this means ten minutes). Press the + button until the display reads 00:10 (this means ten minutes). Set the switch to. The Inspector beeps three times and starts counting. Set the Timer switch to On. The Inspector beeps three times and starts counting. At the end of the ten minutes, the Inspector beeps three times, and repeats beeping several times. Note the total reading. At the end of the ten minutes, the Inspector beeps three times, and repeats beeping several times. Note the total reading. Divide this number by ten for the average count per minute which is the average background count per minute. Divide this number by ten for the average count per minute which is the average background count per minute.

March 2005International Medcom How to Change the Battery Turn the Inspector over. Turn the Inspector over. Remove the battery cover. Remove the battery cover. Detach the 9 volt battery from the wire connector and replace. Detach the 9 volt battery from the wire connector and replace. The battery life for the Inspector is approximately 200 hours. The battery life for the Inspector is approximately 200 hours.