Continuous Ammonia Monitoring Jim Schwab, ASRC, University at Albany, SUNY With contributions from many others!

Slides:



Advertisements
Similar presentations
Sampling and Measurement for Volatile Organic Compounds
Advertisements

Lessons Learned from Sarnia Area Monitoring Presented by: Ed Kuley ORTECH Environmental November 6, 2014.
Albert J. Heber, Associate Professor Director, Purdue Agricultural Air Quality Lab Agricultural and Biological Engineering Purdue University Building Environment.
FLAME SPECTROSCOPY The concentration of an element in a solution is determined by measuring the absorption, emission or fluorescence of electromagnetic.
Tekran ® Automated Mercury Speciation F.H. Schaedlich 1, Robert K. Stevens 2, D.R. Schneeberger 2, Eric Prestbo 3, Steve Lindberg 4, Gerald Keeler 5 F.H.
Prototype Compact Denuders for Ambient Air Sampling Misha Schurman(1), Jeffrey L. Collett, Jr. (1), Susanne V. Hering (2), Derek E. Day (3), William C.
Modification of Network Sampling Systems for Measurement of NH 3 Derek Day, Misha Schurman, Katie Beam, Jeff Collett, William Malm MOTIVATION Ammonia (NH.
1 Atomic Absorption Spectroscopy Atomic Emission Spectroscopy Lecture 18.
AAS and FES (Ch 9, 7th e, WMDS)
427 PHC.  Atomic emission spectroscopy (AES) is based upon emission of electromagnetic radiation by atoms.
Criminalistics, 10e Richard Saferstein © 2011, 2007, 2004, 2001, 1998, 1995 Pearson Higher Education, Upper Saddle River, NJ All Rights.
Measurement of NO y During SCOS97-NARSTO Dennis R. Fitz University of California, Riverside College of Engineering Center for Environmental Research and.
QA/QC Considerations for Sampling and Analysis Associated with EPA Method 1631 Chuck Wibby Wibby Environmental Seminar on Low Level Mercury Data and Analyses.
Soot Particle Aerosol Mass Spectrometer: Development, Validation, and Initial Application T. B. Onasch,A. Trimborn,E. C. Fortner,J. T. Jayne,G. L. Kok,L.
How long will the test last?
Picarro Cavity Ring Down Spectrometry (CRDS) for High-Precision Continuous Monitoring of Atmospheric CO 2 and CH 4 Dave Lowry, Rebecca Fisher, Mathias.
© 2011 Cemtek Environmental, Inc. Particulate Matter Monitoring Technologies and Detection Principles CEMTEK Environmental Inc S. Orange Ave. Santa.
 Amino acid analysis refers to the methodology used to determine the amino acid composition or content of proteins, peptides, and other pharmaceutical.
Gas Analyzer Theory of Operation
EPA Precursor Gas Training Workshop Kevin A Cavender EPA-Office of Air Quality, Planning and Standards Precursor Gas Monitoring NO y Monitoring Training.
National Air Monitoring Conference EPA Precursor Gas Training Workshop Dennis K. Mikel EPA - Office of Air Quality, Planning and Standards Technical.
Lesson 5 What devices do we use to measure radon?.
Antek 6200 ® Meet Sulfur Regulations and Control Your Process with Continuous Measurements Product Presentation.
Atomic Emission Spectroscopy
GC-HR-ToF Instrument overview 7/16/2015 JDC. Instrument Systems.
Trends in the Wet and Dry Deposition of Nitrogen and Sulfur Species
TEMPLATE DESIGN © v DIRECT DEMONSTRATION OF THE GREENHOUSE EFFECT Abstract Consider these three “theories:” climate change,
Quality assurance of sampling and analytical instruments
IMPROVE Ion Study Plan Presented by Marc Pitchford to the RPO Technical Groups Dallas, TX 12/3/02.
Your analytical partner ! Company Introduction Company Profile: Experience Customers Products: Reducing Compound Photometer Flame Ionization Detector Span.
1 Saxony-Anhalt EU Twinning RO 04/IB/EN/09 State Environmental Protection Agency Wolfgang GarcheWorkshop European Standards Requirements of.
Development of a Near-IR Cavity Enhanced Absorption Spectrometer for the detection of atmospheric oxidation products and amines Nathan C. Eddingsaas Breanna.
Field Analytical Methods. Considerations for Field Analytical Methods Which parameters are anticipated to occur at the site? What media will be analyzed?
Field Methods of Monitoring Atmospheric Systems Measurement of Air Pollution Copyright © 2009 by DBS.
Mass Spectroscopy 1 Mass Spectroscopy (Mass Spec) Applying Atomic Structure Knowledge to Chemical Analysis.
Ammonia Measurement Techniques Ji-Qin (Jee-Chin) Ni, Ph.D. Dept. of Agricultural and Biological Engineering Purdue University October 21, 2008 Albuquerque,
1 Introduction to Atomic Spectroscopy Atomic Absorption Spectroscopy Lecture 12.
Field Methods of Monitoring Atmospheric Systems Remote Sensing Copyright © 2006 by DBS.
MS Calibration for Protein Profiles We need calibration for –Accurate mass value Mass error: (Measured Mass – Theoretical Mass) X 10 6 ppm Theoretical.
N 2 O-Measurement Methods Folie 1 Nitrous Oxide/Laughing Gas Molar mass: 44,013 kg/kmol Gas density at 0°C and 1,013 bar: 1,9781 kg/m³ Gas density in relation.
Chebatoris, A.W., Harvey, J.W., Hess, B.T., Krepps, J.P., O’Brien, K.A., Short, D.B., and Spaulding, R.E. Abstract Nitrogen dioxide is a criteria air pollutant.
Linhan Shen1, Thinh Bui1, Lance Christensen2, Mitchio Okumura1
A second, but different NBL case Seasonal Variation Diurnal Variation Continuous Tower-Based Ozone Measurements L.C. Patrick 1, S.J. Oltmans 2, J.C. Williams.
Impact of Temporal Fluctuations in Power Plant Emissions on Air Quality Forecasts Prakash Doraiswamy 1, Christian Hogrefe 1,2, Eric Zalewsky 2, Winston.
Aerosol Chemical Speciation Monitor ACSM Instrument description and sample data N.L. Ng, T. Onasch, A. Trimborn, S. Herndon, M. Canagaratna, D. Sueper,
Dieterich, M.F., Gieseler, M.E., Short, D.B., and Signorelli, R.T. Abstract Nitrogen dioxide is a criteria air pollutant regulated by the Federal Government.This.
Introduction Instruments designed and fabricated at the Desert Research Institute, Reno Emphasis on the Integrating Nephelometer for scattering measurements.
Hygrometry Part 2.
Office of Research and Development National Risk Management Research Laboratory, Air Pollution Prevention and Control Division Photo image area measures.
Update on CASTNET Modernization Air Monitoring Steering Committee Meeting May 4, 2006 Larry Kertcher Office of Atmospheric Programs (OAP)
Chapter 1: The Nature of Analytical Chemistry
Melinda Beaver 1, Keith Kronmiller 2, Rachelle Duvall 1, Surender Kaushik 1, Timothy Morphy 3, Patrick King 3, and Russell Long 1 1 US EPA Office of Research.
Review of Federal Reference Method for Ozone: Nitric Oxide-Chemiluminescence Office of Research and Development National Exposure Research Laboratory April.
AIR CLIMATE & ENERGY RESEARCH PROGRAM B U I L D I N G A S C I E N T I F I C F O U N D A T I O N F O R S O U N D E N V I R O N M.
이 장 우. 1. Introduction  HPLC-MS/MS methodology achieved its preferred status -Highly selective and effectively eliminated interference -Without.
Determinations and Interpretations of FTIR Detection Limits
Determination of TKN by Subtraction using ASTM D and ASTM D
Quality is a Lousy Idea-
An in-depth look at trace metallic impurity determination by ICP-OES
LIAISON®: Instrument Overview
Donna Kenski Lake Michigan Air Directors Consortium, Des Plaines, IL
Strategies for Eliminating Interferences in Optical Emission Spectroscopy Best practices to optimize your method and correct for interferences to produce.
Introduction to Atomic Spectroscopy
Quality is a Lousy Idea-
Unmanned Aircraft Systems (UAS)
Preliminary Results: HONO and HNO3 from the MC/IC.
Continuous measurement of airborne particles and gases
A Review of Time Integrated PM2.5 Monitoring Data in the United States
Eiko Nemitz Centre for Ecology and Hydrology (CEH) Edinburgh, U.K.
Comparison of NH3/NH4 and HNO3/NO3 measurements with DELTA minidenuders and impregnated filter methods Robert Gehrig / Christoph Hüglin / Andrea Fischer.
Presentation transcript:

Continuous Ammonia Monitoring Jim Schwab, ASRC, University at Albany, SUNY With contributions from many others!

Additional Contributers Eric Edgerton, ARA, Cary, NC Minsuk Bae, Yongquan Li, Ken Demerjian, John Spicer – ASRC Sara Pryor – Indiana University Bjarne Jensen - Danish National Environmental Research Institute Jian Hou, Xianliang Zhou – University at Albany School of Public Health Donna Kenski - LADCO

Continuous Methods Potential Routine Methods –Chemiluminescence SEARCH TRN API Model 201E or Thermo Model 17C (1 ppb LDL) –Ion Mobility Spectrometer –Laser Acousto-Optical Detection –AiRRmonia – ECN, Netherlands, Mechatronics Instruments, b.v. Research Methods –Tunable Diode Laser – TDLAS –Wet Effusive Diffusion Denuder (WEDD) –Wet Scrubbing Long Path Absorption Spectrometer – WS-LOPAP –Wet Scrubbing IC analysis (URG AIM 9000) –MARGA – Steam Jet Collection – IC

SEARCH Continuous NH 3 Method (TRN) 2-channel oxidized AND reduced nitrogen chemiluminescence analyzer Channel 1 samples ambient air through a sodium carbonate denuder (TN), then two heated converters Channel 2 samples ambient air through dual sodium carbonate and citric acid denuders (TN* ), then through a single moly converter NH 3 operationally defined as TN-TN*

Total Reduced Nitrogen (TRN) Analyzer 650º C Pt Converter 350º C Moly Converters Total Reactive Nitrogen after Na 2 CO 3 denuder Total Oxidized Nitrogen after Na 2 CO 3 and citric acid denuders

NH 3 and NH 4 + during CFPP Plume Event NH 4 + increases; NH 3 disappears; NH x conserved

Method 2 - IMS Candidate for routine monitoring IMS – Ion Mobility Spectrometer (AirSentry-IMS Ammonia Analyzer, Particle Measuring Systems, Boulder, CO) Ionization based time-of-flight technique performed at atmospheric pressure Instruments are targeted to a specific molecule in a specific concentration range Range for this instrument: 0–300 ppb (Lab Intercomparison); ppb (Field Deployment) Cost (with OBC) ~ $26 K

Operational Details Requires up to 5 li/min of clean, dry instrument air (dewpoint ≤ -40º C) Internal sample pump option Factory default “Smoothing Factor” (8) should be increased for minute (or longer) averaged data Optional “On Board Calibration” - integral permeation oven set up (recommended) Nickel 63 sealed radioactive source (less than.005 microcuries) – ionization source

Preliminary data: do not cite or quote! IMS Field Data

Pranalytica Nitrolux NH3 Analyzer Photoacoustic spectroscopy CO2 laser Low-noise microphone In-line particle filter (40 µm) LDL and cost depend on model Model 1000 – LDL ~ 1 ppb; Cost ~$24K Model 200 – LDL ~ 0.2 ppb; Cost ~$38K Model 100 – LDL ~ 0.1 ppb; Cost ~$72K Note: Instrument used was one of the first sold by Pranalytica and company claims to have made significant improvements to later (i.e. current) instruments

Laboratory Intercomparison September 12-30, 2005 at ASRC Six measurement Methods – seven instruments in all (Chemiluminescence method not included because instrument was not configured properly – my error) Heated glass manifold for uniformity of sampling environment Synthetic air and calibration system “Ambient” sample for two extended periods

Method Characteristics Tested during Intercomparison Response to known [NH 3 ] – accuracy and precision of calibration Time Response – to step changes and “spikes” Comparability during ambient sampling Potential interferences

Preliminary data: do not cite or quote!

Sampling and response time This is an important issue for gaseous ammonia measurement – it clearly affects methods detecting gaseous ammonia directly and ammonium after scrubbing. The TDL is the system of choice for quick and accurate response – but it is not a “routine” method!

Spring 2006 Measurements – Pinnacle State Park, Addison, NY NH 3 measured with AirSentry IMS HNO 3 with denuder difference chemiluminescence method NH 3 HNO 3 Mean1.06 ppb0.66 ppb Standard Dev.0.77 ppb0.62 ppb Median0.87 ppb0.48 ppb Maximum5.82 ppb5.75 ppb Est. MDL0.3 ppb0.2 ppb Completeness90.1%85.4%

Response Time – Memory Effect Note that on previous slide the HNO 3 drops below 1 ppb each night However, NH 3 does not drop very low between peaks We believe this is due – at least in part – to changing uptake and release of NH 3 on the sample inlet, the switching valves, and the sample handling lines in the instrument

Candidate Methods for Monitoring – and their Major Shortcoming(s) (Editorial Opinions!) ARA TRN (chemiluminescence) –Not ammonia specific –Three heated converters – difference method AirSentry IMS (Particle Measuring) –Response Time Problem Nitrolux 200 (or 100) (Pranalytica) –Response Time (worst of all tested instruments, but should be better in current versions) –Cost – Highest of “routine monitoring” candidates (for sufficiently low LDL) AIRRmonia, URG AIM, MARGA – need liquid reagents

Recommendation ARA TRN (chemiluminescence) –Custom implementation of proven analyzer –Response time issue minimized (eliminated?) since there is no “handling” of ammonia –EPRI is considering commercialization of converter technology

Acknowledgements Funding from –EPA –NYSERDA –NYSDEC Although the research described in this article has been funded in part by the U.S. Environmental Protection Agency, it has not been subjected to the Agency’s required peer and policy review and therefore does not necessary reflect the views of the Agency and no official endorsement should be inferred should be inferred.

End of Presentation

Nitric Acid Measurement Denuder difference in conjunction with NO y TECO 42S low-level chemiluminescence analyzer – operates with two measurement channels and one background (“prereactor zero”) channel Both measurement channels preceded by external heated molybdenum converters “Base” channel is NO y Second channel uses a NaCl coated denuder as inlet – this channel measures NO y – HNO 3 Difference of channels is HNO 3

Schematic of HNO 3 Method SS NEMA box mounted outside (5 m agl) Heated Mo converter Gas lines NaCl coated denuder PFA Teflon Tube OUTSIDEINSIDE Model 42S chemiluminescence analyzer Mode switching valves Power and signal wires BYPASS PUMP

1-minute NH 3 and WD at Yorkville Spikes between 90 and 180 degrees suggest nearby NH 3 sources.

Local Sources of NH 3 at YRK Poultry operations within several km line up with NH 3 spikes. 2.6 km 1.5 km 3.3 km