January 12, 2013 G460 PID sensor performance and maintenance Slide 1 G460 PID sensor performance and maintenance GfG Instrumentation, Inc. 1194 Oak Valley.

Slides:



Advertisements
Similar presentations
OPERATION AND MAINTENANCE
Advertisements

Filter Changing Procedures For TEOM Series 1400ab and Model 8500 FDMS (B & C Types)
Student Overview MMS Wireless Mobile Lab. Removing the laptops from the cart Each laptop is numbered. Each slot in the cabinet is numbered. Pick up your.
Each laptop is numbered Each slot in the laptop cabinet is numbered. Be sure to pick up the laptop that has been assigned to you! Getting the Laptops.
Engine Tune-Up By Jonathan Rollins.
SECTION 11 LEVEL B SUIT OUT. SECTION 12 AIR MONITORING.
ELITE XR THERMAL IMAGER
Bump-test and Calibration Procedures
Using the MiniRAE 3000.
AnaSonde Assembly. What is the AnaSonde? *Reads temperature, pressure, and humidity data from the atmosphere *After it is sent into the atmosphere, it.
Digital StarLab Set-Up, Operation, Maintenance, and Teacher Manual for the Digital StarLab are in the links below or on the training tab in the BlackBoard.
Company Confidential © 2005 All Rights Reserved. What is it? State-of-the-art: microprocessor-based, wall-mount gas monitor Easy installation and operation:
PN: TM rev:3 Preventive Maintenance Course.
January 7, 2013 Changing or replacing G460 sensors Slide 1 November 9, 2012 Changing or replacing G460 sensors.
Hemoglobin Testing Using the HemoCue. Instrument calibration At the beginning of each survey day, check the instrument accuracy using the calibrator cuvette.
1 USDOC41 Rev 0 1/04 Training and Education Program ©2004 HemoCue, Inc. HemoCue ® Training and Education Program The HemoCue Hb System.
1 Tire repair procedures This presentation has been prepared from copyrighted materials from REMA TIP TOP / North America and is reproduced with their.
4Identifying Leakage Source (Mech/ Elec) 4Mechanical Air Leak- Down 4Mechanical Air Leak- Up 4Electronic Drift- Up/ Down 4Load Cell Operation 4Understanding.
860 21/2”-10”. Modification Overview  Production of the 2½” – 10 sizes began in  Lead free version (LF860) was introduced in Parts do not.
Clean Air Box Usage & Care CABs RAMs CO Monitors.
F LOTEC Training Presentation for Authorized Repair Centers This presentation is designed to supplement M-Service Manual InGage Regulator.doc Flotec, Inc.
4135 Bluebonnet Dr. Stafford, TX
ISE eFleet Suite Software Installation Manual
(Smart Loop System) Installation Guide. Rev B Shipping Box Contains Everything that is included in the box being shipped to a customer should contain.
Altair® 5X MultiGas Detector Altair® 5X MultiGas Detector The ALTAIR 5X MultiGas Detector is to be used when performing a hazard assessment.
Introduction to Measuring Tools Rice Air Curriculum Teacher Training.
Gage Blocks.
PPE Use Standard (SSP-0011) Y Full Face Shield / Goggles Hood Clothing—Chemical Protection Gloves—Chemical Personal Fall Protection Respirator / Filter.
How To Replace Your Fuel Filter On a 1998 Mustang GT.
Tru Count Air Clutch Maintenance
Chapter Five Maintaining a Computer Part I: Cleaning a Computer.
Respirator Safety This Training Covers Respirator Inspection User Fit Checks Respirator Cleaning Respirator Storage.
WELCOME TO Gas Tester Training O2, LEL Monitoring
Maintenance Course Preventive Maintenance Course.
Reducing risk with Exposure Monitoring Equipment.
Heat Fire Working with or Heat or Fire When working with heat or fire, you will need to wear safety goggles. To move hot objects you will need to use.
Removing and Replacing the Battery Cover 1. Ensure the phone is turned off. 2. Press the Battery cover locker; lift the battery cover up and away from.
MX6 iBrid Multi-Gas Monitor
Gage Blocks Unit 12.
MSA Five Star 4-Gas Monitor Air Monitoring Instrumentation.
PH: Opening Page – On a colour 7” touch screen monitor. (Acdat – Active Data) which is mounted within the operators vision of the cab.
E VERY L IFE H AS A P URPOSE… Toxgard ® II Gas Monitor.
Troubleshooting Windows Vista Lesson 11. Skills Matrix Technology SkillObjective DomainObjective # Troubleshooting Installation and Startup Issues Troubleshoot.
TM Revision 2 Preventive Maintenance Course.
L2000 Technical Training 5. Installation and Servicing.
BMC Medical Co., Ltd. Nov Training Course. 1 Table of Contents 1. CATALOGUE 2. INSTALL& DISASSEMBLE 3. SET UP.
EGA Technical World Leaders in Combustion Management Solutions Mk7 EGA.
ACCU-CHEK Inform II Operator Training
EGA Technical World Leaders in Combustion Management Solutions Mk7 EGA.
World Leaders in Combustion Management Solutions Module Gas Setup Introduction The Mk7 E.G.A Cell Status Further Information.
LF866 2½”-10”. Product Overview  Production of the 2½” – 10” sizes began in  The LF866 utilizes a Type 2 bypass (Model LF619 single check).
© MSA 2015 Because every life has a purpose… Altair 5X with PID and Xtirpa Fall Protection Solutions 11/9/15 – Airgas Joe Gormley / Andy DeLair– MSA Safety.
F-900 PORTABLE ETHYLENE ANALYZER INSTRUMENT TRAINING
Rapid Change Technology The following is a presentation to aid Technicians in the replacement of the Rapid Change Technology Block.
Misuse of Combustible Gas Meters Supervisor Training 1/11/08.
© 2006 Plano ISD, Plano, TX. Heat Fire Working with or.
Svara Functional overview
QuickServe Online Service Training
Jim Vermeulen MSA Territory Manager
Tips to Download or Install Norton Security to Computer Device.
Module 9: Microscope Maintenance
Bob Henderson, BS, MBA GFG Instrumentation Inc. Ann Arbor, MI
G450 and G460 battery pack maintenance
LIFEPAK® 1000 Defibrillator Orientation Guide
Updating instrument firmware
URINALYSIS DIPSTICK TESTING
880V 21/2”-10”.
The bios.
QuickServe Online Service Training
QuickServe Online Service Training
Presentation transcript:

January 12, 2013 G460 PID sensor performance and maintenance Slide 1 G460 PID sensor performance and maintenance GfG Instrumentation, Inc Oak Valley Drive, Suite 20 Ann Arbor, Michigan Toll free (USA and Canada): (800) Direct: Service Internet: Technical documentation and download site:

January 12, 2013 G460 PID sensor performance and maintenance Slide 2 G450 / G460 Advanced Service Procedures WARNING: Advanced service procedures should only be undertaken by authorized personnel

January 12, 2013 G460 PID sensor performance and maintenance Slide 3 G460 Smart Sensor PID PID Smart-Sensor Broad range VOC measurement Extremely sensitive Available in two ranges: 0.5 – 2,000 ppm (Standard PID sensor) 0.1 – 500 ppm (Optional high resolution PID sensor)

January 12, 2013 G460 PID sensor performance and maintenance Slide 4 PID range and resolution Two versions of the PID sensor available for G460: “Standard” PID provides 0.5 ppm resolution over 0 – 2000 ppm (isobutylene scale) “High Resolution” PID provides 0.1 ppm resolution over 0 – 500 ppm (isobutylene scale) “VOC” choice allows the user to specify custom correction factor for a gas not included in the standard on-board library The full range for the gas selected depends on the relative response of the sensor to the target gas compared to isobutylene For instance, when “NH3” (ammonia) is selected, because of the lower relative response to ammonia compared to isobutylene, the full range is expanded from 0 – 2000 (iso scale) to 0 – 6000 ppm (NH3 scale)

January 12, 2013 G460 PID sensor performance and maintenance Slide 5 PID sensor menu  PID sensor choices include "Range and Gas"  Use to choose correction factor for new gas from PID library  PID readings displayed in measurement units of gas selected  Name of gas selected will appear in the sensor menu PID position  In normal operation screen will show name of new gas Range and Gas ppm iButyln ppm Gasolin ppm MIBK ppm Acetone ppm Deether ppm Propyln ppm iButyln CH4 CO iButyln

January 12, 2013 G460 PID sensor performance and maintenance Slide 6 PID sensor “Gas and Unit” library choices PID Gas List Abbreviations Common NameRange with 0 – 2000 ppm full range PID (ISO) Range with 0 – 500 ppm full range PID (ISO) iButylnIsobutylene0 – – 500 VOCGeneric VOC with user assigned CF0 – – 500 GasolinGasoline0 – – 500 MIBKMethyl-iso-butyl-ketone0 – – 500 Acetone 0 – – 500 DeetherDiethylether0 – – 500 PropylnPropylene0 – – 500 MEKMethyl-ethyl-ketone0 – – 375 Diesel 0 – – 375 TrClEynTrichloroethylene0 – – 250 Benzene 0 – – 250 Toluene 0 – – 250 Xylene 0 – – 250 Styrene 0 – 8000 – 200 JetfuelJet fuel (JP-8)0 – 8000 – 200 nButnoln-Butyl-alcohol0 – – 1500 EtActatEthyl acetate0 – – 1500 nHexanen-Hexane0 – – 1500 NH3Ammonia0 – – 1500 cHexaneCyclo hexane0 – – 750 VyChlrdVinyl chloride (VCM)0 – – 750 MeBromdMethyl bromide0 – – 750 nNonanen-Nonane0 – – 750 Octane 0 – – 750 Heptane – 750

January 12, 2013 G460 PID sensor performance and maintenance Slide 7 G460 Interchangeable Smart Sensors Five Smart Sensor positions on PCB: All you need to do is plug the sensor into a position designed for that type of sensor EC 1: COSH EC 1, 2, 3: CO, H2S, O2, NH3, SO2, H2, PH3, HCN EC 2, 3: NO, NO2, CL2, HCL, ETO, O3, ClO2, HF EC 2: PID PL: 1 – 100% LEL “pellistor” sensor IR: Vol % CO2; 0 – 100% LEL combustible; 0 – 100% vol combustible

January 12, 2013 G460 PID sensor performance and maintenance Slide 8 G460 Main PCB: Five Smart Sensor Positions EC1 (Lower Left) EC2 / PID (Lower Right) EC3 (Upper Left) IR (Center) PL (Upper Right)

January 12, 2013 G460 PID sensor performance and maintenance Slide 9 The G460 PID is protected by both external and internal filters Because gas diffuses into and out of the sensor (rather than using a pump to pull the atmosphere across the lamp and electrodes) the system is less prone to particulate contamination Note: The PID lamp and electrodes should only be cleaned when needed! The primary symptoms that indicate the need to clean the lamp are: 1.Unstable readings 2.Oversensitivity to humidity 3.Failure to calibrate G460 PID maintenance

January 12, 2013 G460 PID sensor performance and maintenance Slide 10 G460 PID Maintenance The following slides show the step-by-step procedure for cleaning the G460 PID The manufacturer of the PID lamp (Baseline-MOCON, Inc.) has also posted a training video at the following link: The password is: baseline11 G460 PID cleaning kit (PN ): includes replacement filters, lamp polishing pads, tweezers and compressor stick Note: The appearance of the Baseline-MOCON “PID Plus” sensor in the video is slightly different from the GfG PID version. The procedure for disassembly and cleaning the lamp is exactly the same, however.

January 12, 2013 G460 PID sensor performance and maintenance Slide 11 G460 PID Maintenance Kit Lamp polishing pad Padded stick Outer filter (moisture barrier) Inner filter PID maintenance kit components

January 12, 2013 G460 PID sensor performance and maintenance Slide 12 Wear gloves when handling or disassembling PID G460 PID Maintenance Cautions Note: Direct contact between fingers and PID lamp, electrodes and other components can leave oils and contaminants behind that can degrade performance

January 12, 2013 G460 PID sensor performance and maintenance Slide 13 G460 PID Maintenance Make sure instrument is turned off! Remove battery, open housing, and CAREFULLY remove main board and display assembly exposing sensors Remove PID sensor PID sensor

January 12, 2013 G460 PID sensor performance and maintenance Slide 14 G460 PID Maintenance Use tweezers to pry the top off of the sensor Position the tweezers next to the cap opening Remove the sensor cap

January 12, 2013 G460 PID sensor performance and maintenance Slide 15 G460 PID Maintenance Remove filters (inner and outer) Remove spacer

January 12, 2013 G460 PID sensor performance and maintenance Slide 16 G460 PID Maintenance Gently remove sensor PCB Grip at back of board (near pins)

January 12, 2013 G460 PID sensor performance and maintenance Slide 17 G460 PID Maintenance Use tweezers to GENTLY pry the lamp out of the sensor Do not touch window or body of lamp with naked fingers

January 12, 2013 G460 PID sensor performance and maintenance Slide 18 G460 PID Maintenance Use circular motion to polish face of lamp window with polishing pad

January 12, 2013 G460 PID sensor performance and maintenance Slide 19 G460 PID Maintenance Clean any lamp, pin, or electrode PCB surfaces that have come into contact with naked skin with alcohol before reassembling Make sure that all components are COMPLETELY air-dried before reassembly Do not use blowers or heated air sources to speed up drying!

January 12, 2013 G460 PID sensor performance and maintenance Slide 20 G460 PID Maintenance Metal pads Metal contacts Insert lamp back into PID sensor assembly NOTE: Metal pads in PID lamp MUST line up with contacts in socket of sensor assembly

January 12, 2013 G460 PID sensor performance and maintenance Slide 21 G460 PID Maintenance Use padded stick to press lamp into place

January 12, 2013 G460 PID sensor performance and maintenance Slide 22 G460 PID Maintenance Reassemble: Sensor PCB Spacer Filters (2) Sensor cap Plug PID sensor back into instrument Calibrate the PID sensor before returning the G460 to service!

January 12, 2013 G460 PID sensor performance and maintenance Slide 23 Returning the instrument to service Calibrate ALL sensors in the instrument (whether or not they have been changed) before returning the instrument to service It is best to let new sensors stabilize in the instrument for 30 minutes prior to calibration

January 12, 2013 G460 PID sensor performance and maintenance Slide 24 Questions?