Electrodes and Potentiometry

Slides:



Advertisements
Similar presentations
Review of Analytical Methods Part 2: Electrochemistry
Advertisements

PH measurements. Measuring the pH of Solutions The activity of a single ion cannot be measured Only measure our ‘best approximation’ to the hydrogen ion.
Potentiometric Methods
Potentiometric Methods A.) Introduction:
15-1 Potentiometry Potential measurements of electrochemical cells Ion selective methods §Reference electrode §Indicator electrode §Potential measuring.
Fig. 22-1a (p.629) A galvanic electrochemical cell at open circuit
A galvanic cell is made from two half cells. In the first, a platinum electrode is immersed in a solution at pH = 2.00 that is M in both MnO 4 -
Summary of Potentiometry:
Introduction to Analytical Chemistry
MLAB 2401: C LINICAL C HEMISTRY K ERI B ROPHY -M ARTINEZ Designs in Instrumentation Electrochemistry.
Tracking Reaction Progress via Electrochemical Methods.
Electroanalytical – Introduction Ch 21, 7th e, WMDS)
Measuring concentration using electrodes Indicator electrodes used with reference electrode to measure potential of unknown solution E cell = E indicator.
POTENTIOMETRY 9th lecture
Section 11 Potentiometry. Potentiometric Electrodes Potentiometric electrodes measure: Activity not concentration Concepts to review: Activity and affect.
14-6 Cells as chemical probes
Potentiometry. pH is a Unit of Measurement  pH = Power of Hydrogen (H + )  Defined as the Negative Logarithm of Hydrogen Ion Activity  pH = log (1/H.
Chapter 14 Electrodes and Potentiometry
Chem. 133 – 3/5 Lecture. Announcements Lab –Set 2 Period 2 Labs Set to Finish 3/10 –3/12 will be make up day (for both Period 1 and Period 2 labs) –Set.
Dr. Marc Madou, UCI, Winter 2012 Class V Potentiometric and Amperometric Sensors (I) Electrochemistry MAE-295.
Potentiometry and the Detection of Fluoride
Fall 2014, Prof. JB Lee Ion Sensitive FET (ISFET) - What and Why?
Potentiometric Methods
ANALYTICAL CHEMISTRY CHEM 3811 CHAPTER 15 DR. AUGUSTINE OFORI AGYEMAN Assistant professor of chemistry Department of natural sciences Clayton state university.
THE HYDRONIUM ION The proton does not actually exist in aqueous solution as a bare H + ion. The proton exists as the hydronium ion (H 3 O + ). Consider.
Oxidation-Reduction (Redox) Reactions
Prentice Hall © 2003Chapter 20 Zn added to HCl yields the spontaneous reaction Zn(s) + 2H + (aq)  Zn 2+ (aq) + H 2 (g). The oxidation number of Zn has.
Fundamentals of Electrochemistry Introduction 1.)Electrical Measurements of Chemical Processes  Redox Reaction involves transfer of electrons from one.
POTENTIOMETRY 8th lecture
ANALYTICAL CHEMISTRY CHEM 3811 CHAPTER 14
Electroanalysis measure the variation of an electrical parameter (potential, current, charge, conductivity) and relate this to a chemical parameter (the.
South Fork Instruments Advances in pH/ORP Measurement – Polymeric Sensors Presented by John Daly South Fork Instruments.
1 Oxidation Reduction Equilibria and Titrations. 2 Oxidation - Reduction reactions (Redox rxns) involve the transfer of electrons from one species of.
Fundamentals of Electrochemistry Introduction 1.)Electrical Measurements of Chemical Processes  Redox Reaction involves transfer of electrons from one.
Chapter 22 REDOX.
Electroanalytical methods
Potentiometry and potentiometric measurements. potentiometer A device for measuring the potential of an electrochemical cell without drawing a current.
Potentiometry Dr Hisham E Abdellatef 2010.
Unit 2 Electrochemical methods of Analysis
Coulometric Methods A.) Introduction:
Electrochemistry Physical Chemistry. Daniel Cell 1. Electrochemistry is the study of the interconversion of electrical and chemistry energy. 2. Voltaic.
Announcements Course Evaluations Final is Wednesday Afternoon on May 9 th Homework 14-15, 14-26, 15-6, 16-3, 16-6,
1. Blood or Fluid Analysis Using carried out in central labs with problems of time delay costs and potential misslabeling Drive toward more bedside or.
Chapter 15 Electrode Measurements “Chem 7” test in hospital lab. Na +, K +, Cl -, CO 2, glucose, urea, & creatinine ion-selective electrodes.
Electroanalysis measure the variation of an electrical parameter (potential, current, charge, conductivity) and relate this to a chemical parameter (the.
Electrochemical Methods Dr M.Afroz Bakht. Potentiometry Potentiometry is a method of analysis used in the determination of concentration of ions or substances.
A.) Introduction : 1.) Coulometry: electrochemical method based on the quantitative oxidation or reduction of analyte - measure amount of analyte by measuring.
THE ELECTROD AND REDOX POTENTIIALS.
Electrodes and Potentiometry Introduction 1.)Potentiometry  Use of Electrodes to Measure Voltages that Provide Chemical Information - Various electrodes.
Chem. 133 – 3/3 Lecture. Announcements Homework Set 2 (pass out) Grading –Working to get the Electronics labs and exam 1 graded by next Tuesday Lab –today.
POTENTIOMETRY.
Chapter 21 Potentiometry. Potentiometric methods of analysis are based on measuring the potential of electrochemical cells without drawing appreciable.
Electrode Measurements – Ch 15
Home Reading Skoog et al. Fundamental of Analytical Chemistry. Chapters 18, 19, 21.
Art PowerPoints Harris: Quantitative Chemical Analysis, Eight Edition CHAPTER 14: ELECTRODES AND POTENTIOMETRY.
Ch. 21 Potentiometry 1. General principles
POTENTIALS AND THERMODYNAMICS OF CELLS (1) POTENTIALS AND THERMODYNAMICS OF CELLS (1)
Home Reading Skoog et al. Fundamentals of Analytical Chemistry. Chapter 10, 21.
SCI3023 ELECTROCHEMISTRY Chapter 8e: Potentiometry
Inovace bakalářského studijního oboru Aplikovaná chemie Reg. č.: CZ.1.07/2.2.00/
Potentiometry and Ion-Selective Electrodes 1 Lecture 1.
Chem. 133 – 2/28 Lecture.
Potentiometry and potentiometric measurements
Ion Selective Electrode
Potentiometry Potential measurements of electrochemical cells
Quantitative Chemical Analysis
Fundamentals of Electrochemistry
Tracking Reaction Progress via Electrochemical Methods
Chapter 23 Potentiometry.
Presentation transcript:

Electrodes and Potentiometry Introduction 1.) Potentiometry Use of Electrodes to Measure Voltages that Provide Chemical Information Various electrodes have been designed to respond selectively to specific analytes Use a Galvanic Cell Unknown solution becomes a ½-cell Add Electrode that transfers/accepts electrons from unknown analyte Connect unknown solution by salt bridge to second ½-cell at fixed composition and potential Indicator Electrode: electrode that responds to analyte and donates/accepts electrons Reference Electrode: second ½ cell at a constant potential Cell voltage is difference between the indicator and reference electrode

Potential is proportional to [heparin] Electrodes and Potentiometry Introduction 2.) Example A Heparin Sensor Voltage response is proportional to heparin concentration in blood Sensor is selective for heparin heparin Negatively charged heparin binds selectively to positively charged membrane. Binding generates potential difference. Potential is proportional to [heparin]

Reference electrode, [Cl-] is constant only depends on [Fe2+] & [Fe3+] Electrodes and Potentiometry Reference Electrodes 1.) Overview Potential change only dependent on one ½ cell concentrations Reference electrode is fixed or saturated  doesn’t change! Reference electrode, [Cl-] is constant Potential of the cell only depends on [Fe2+] & [Fe3+] Unknown solution of [Fe2+] & [Fe3+] Pt wire is indicator electrode whose potential responds to [Fe2+]/[Fe3+]

Electrodes and Potentiometry Reference Electrodes 2.) Silver-Silver Chloride Reference Electrode Convenient Common problem is porous plug becomes clogged Eo = +0.222 V Activity of Cl- not 1E(sat,KCl) = +0.197 V

Electrodes and Potentiometry Reference Electrodes 3.) Saturated Calomel Reference Electrode (S.C.E) Saturated KCl maintains constant [Cl-] even with some evaporation Standard hydrogen electrodes are cumbersome Requires H2 gas and freshly prepared Pt surface Eo = +0.268 V Activity of Cl- not 1E(sat,KCl) = +0.241 V

Electrodes and Potentiometry Reference Electrodes 4.) Observed Voltage is Reference Electrode Dependant The observed potential depends on the choice of reference electrode Silver-silver chloride and calomel have different potentials Use Reference Scale to convert between Reference Electrodes Observed potential relative to Ag|AgCl Observed potential relative to SCE Observed potential relative to SHE

Electrodes and Potentiometry Junction Potential 1.) Occurs Whenever Dissimilar Electrolyte Solutions are in Contact Develops at solution interface (salt bridge) Small potential (few millivolts) Junction potential puts a fundamental limitation on the accuracy of direct potentiometric measurements Don’t know contribution to the measured voltage Different ion mobility results in separation in charge Again, an electric potential is generated by a separation of charge

Electrodes and Potentiometry Indicator Electrodes 1.) Two Broad Classes of Indicator Electrodes Metal Electrodes Develop an electric potential in response to a redox reaction at the metal surface Ion-selective Electrodes Selectively bind one type of ion to a membrane to generate an electric potential Remember an electric potential is generated by a separation of charge

Electrodes and Potentiometry Indicator Electrodes 2.) Metal Electrodes Platinum Most common metal indicator electrode Inert: does not participate in many chemical reactions Simply used to transmit electrons Other electrodes include Gold and Carbon Metals (Ag, Cu, Zn, Cd, Hg) can be used to monitor their aqueous ions Most metals are not useable Equilibrium not readily established at the metal surface Example: ½ Reaction at Ag indicator electrode: E+o = +799 V ½ Reaction at Calomel reference electrode: E(sat,KCl) = +0.241 V Cell Potential from Nernst Equation: Potential of Ag indicator electrode Cell voltage changes as a function of [Ag+]

Electrodes and Potentiometry Indicator Electrodes 3.) Example A 10.0 mL solution of 0.0500 M AgNO3 was titrated with 0.0250M NaBr in the cell: S.C.E. || titration solution | Ag(s) Find the cell voltage for 10.0 mL of titrant

Electrodes and Potentiometry Indicator Electrodes 4.) Ion-Selective Electrodes Responds Selectively to one ion Contains a thin membrane capable of only binding the desired ion Does not involve a redox process Membrane contains a ligand (L) that specifically and tightly binds analyte of interest (C+) The counter-ions (R-,A-) can’t cross the membrane and/or have low solubility in membrane or analyte solution C+ diffuses across the membrane due to concentration gradient resulting in charge difference across membrane Potential across outer membrane depends on [C+] in analyte solution A difference in the concentration of C+ exists across the outer membrane. Remember an electric potential is generated by a separation of charge

Electrodes and Potentiometry Indicator Electrodes 4.) Ion-Selective Electrodes Responds Selectively to one ion Contains a thin membrane capable of only binding the desired ion Does not involve a redox process C+ diffuses across the membrane due to concentration gradient resulting in charge difference across membrane A difference in the concentration of C+ exists across the inner membrane. Potential across inner membrane depends on [C+] in filling solution, which is a known constant Electrode potential is determined by the potential difference between the inner and outer membranes: where Einner is a constant and Eouter depends on the concentration of C+ in analyte solution Remember an electric potential is generated by a separation of charge

Electrodes and Potentiometry Indicator Electrodes 4.) Ion-Selective Electrodes Responds Selectively to one ion Contains a thin membrane capable of only binding the desired ion Does not involve a redox process Electrode Potential is defined as: where [C+] is actually the activity of the analyte and n is the charge of the analyte

Electrodes and Potentiometry pH Electrodes 1.) pH Measurement with a Glass Electrode Glass electrode is most common ion-selective electrode Combination electrode incorporates both glass and reference electrode in one body Ag(s)|AgCl(s)|Cl-(aq)||H+(aq,outside) H+(aq,inside),Cl-(aq)|AgCl(s)|Ag(s) Outer reference electrode [H+] outside (analyte solution) [H+] inside Inner reference electrode Glass membrane Selectively binds H+ Electric potential is generated by [H+] difference across glass membrane

Cations (Na+) bind oxygen in SiO4 structure Electrodes and Potentiometry pH Electrodes 2.) Glass Membrane Irregular structure of silicate lattice Cations (Na+) bind oxygen in SiO4 structure

Electrodes and Potentiometry pH Electrodes 2.) Glass Membrane Two surfaces of glass “swell” as they absorb water Surfaces are in contact with [H+]

Electrodes and Potentiometry pH Electrodes 2.) Glass Membrane H+ diffuse into glass membrane and replace Na+ in hydrated gel region Ion-exchange equilibrium Selective for H+ because H+ is only ion that binds significantly to the hydrated gel layer Charge is slowly carried by migration of Na+ across glass membrane Potential is determined by external [H+] Constant and b are measured when electrode is calibrated with solution of known pH

Electrodes and Potentiometry pH Electrodes 3.) Calibration A pH electrode should be calibrated with two or more standard buffers before use. pH of the unknown should lie within the range of the standard buffers Measured voltage is correlated with a pH, which is then used to measure an unknown.

Electrodes and Potentiometry pH Electrodes 4.) Errors in pH Measurements Standards pH measurements cannot be more accurate than standards (±0.01) Junction potential If ionic strengths differ between analyte and standard buffer, junction potential will differ resulting in an error of ±0.01 Junction Potential Drift Caused by slow changes in [KCl] and [AgCl] re-calibrate! Sodium Error At very low [H+], electrode responds to Na+ and the apparent pH is lower than the true pH Acid Error At high [H+], the measured pH is higher than actual pH, glass is saturated Equilibration Time Takes ~30s to minutes for electrode to equilibrate with solution Hydration of glass A dry electrode will not respond to H+ correctly Temperature Calibration needs to be done at same temperature of measurement Cleaning Contaminates on probe will cause reading to drift until properly cleaned or equilibrated with analyte solution

Electrodes and Potentiometry pH Electrodes 4.) Errors in pH Measurements pH measurements are accurate to ± 0.02 pH units Larger errors occur at high and low pH readings

Electrodes and Potentiometry Other Ion-Selective Electrodes 1.) Solid-State Electrode Based on an inorganic crystal Fluoride electrode: LaF3 crystal doped with Eu2+ F- migrates across crystal by “jumping” into crystal vacancies caused by Eu2+ Potential caused by charge imbalance from migrating ion across membrane

Electrodes and Potentiometry Other Ion-Selective Electrodes 2.) Liquid-Based Ion-Selective Electrodes Similar to solid-state electrode Hydrophobic membrane impregnated with hydrophobic ion exchanger Hydrophobic ion exchanger selective for analyte ion Binds Ca+2 Hydrophobic counter-ion Hydrophobic solvent

Electrodes and Potentiometry Other Ion-Selective Electrodes 2.) Liquid-Based Ion-Selective Electrodes Remember: ion-selective electrodes create a potential from a charge imbalance caused by analyte ion migration across membrane

Electrodes and Potentiometry Other Ion-Selective Electrodes 3.) Compound Electrodes Conventional electrode surrounded by a membrane that isolates or generates the analyte to which the electrode responds pH electrode surrounded by membrane permeable to CO2. As CO2 passes through membrane and dissolves in solution, pH changes. pH change is an indirect measure of CO2 concentration

Electrodes and Potentiometry Other Ion-Selective Electrodes 4.) Standard Addition Corrects for analyte dissolved in complex or unknown matrix Blood, urine, biomass, etc Procedure: Measure potential for unknown analyte solution Add small (known) volume of a standard solution Measure new potential Repeat and graph data y b m x where: Vo is the initial volume Vs is the added volume E is the measured potential cx is the unknown concentration cs is the standard concentration s is a constant (bRT/nF)ln10

Electrodes and Potentiometry Other Ion-Selective Electrodes 4.) Standard Addition Corrects for analyte dissolved in complex or unknown matrix Blood, urine, biomass, etc Procedure: 5. x-intercept yields the unknown (cx) concentration Only unknown