Iontophoresis Iontophoreis n Introduction of Ions Into The Body Using Direct Electrical Current n Transports Ions Across A Membrane Or Into a Tissue.

Slides:



Advertisements
Similar presentations
Objectives Electrophysiology
Advertisements

MENS and IONTOPHORESIS. MENS No universally accepted definition or protocol & has yet to be substantiated This form of modality is at the sub-sensory.
Pharmacology for Anesthesia I Introduction. What is a Drug?
Experiment #10 Electrochemical Cell.
Science PowerPoint: William Freddy Curle. Definitions Electrode n. 1. A solid electric conductor through which an electric current enters or leaves an.
Iontophoresis Jennifer Doherty-Restrepo, MS, LAT, ATC
Geiger-Muller detector and Ionization chamber
Administration and Absorption of Drugs. Factors that effect the action of a drug 1.Rate of accumulation at its site of action 2.Concentration of the drug.
Passive transdermal administration of drugs, as with a skin patch, is suitable for non-ionized drugs requiring a relatively small dosage. Ionized drugs,
 The strength of dispersion forces between molecules can affect physical properties of the substances they make up.  In other words… the amount of energy.
Basic Electronics. Need to know Definition of basic electrical paramater A set of rules for elementary circuit analysis The means of current flow in circuits.
Voltaic Cells Chapter 20.
ESAT 3640 Therapeutic Modalities
Lesson 2. Galvanic Cells In the reaction between Zn and CuSO 4, the zinc is oxidized by copper (II) ions. Zn 0 (s) + Cu 2+ (aq) + SO 4 2-  Cu 0 (s) +
Asmah Nasser, M.D. Pharmacokinetics.
Pharmacokinetics Chapter 4.
PH0101 UNIT-5 LECTURE 7 Introduction Types of battery Lithium battery
By Dan Janiak and Mark Hanna September Electrokinetics Electroosmosis- Mark Electrophoresis- Dan.
Biochemical instrumental analysis-7 Dr. Maha Al-Sedik.
Cell Biology: Cell Compounds and Biological Molecules
Principles of Electrical Stimulation. Current Types  Direct Current  Alternating Current  Pulsed Current.
ELECTRIC CURRENTS BY B.Nelson.
Chapter 17 Electrochemistry 1. Voltaic Cells In spontaneous reduction-oxidation reactions, electrons are transferred and energy is released. The energy.
Biology: 4.1 Cells and Their Environment
Qualitative Analysis of Product
Pharmacokinetics Based on the hypothesis that the action of a drug requires presence of a certain concentration in the fluid bathing the target tissue.
Electric field Electric field intensity Electric potential Membrane potential Electric fields organs and tissues Electrocardiography.
Electric and magnetic medical equipment
Absorption enhancements
The Chemistry of Life Why are we studying chemistry? Chemistry is the foundation of Biology.
Shortwave and Microwave Diathermy
Swaminarayan college of engineering and technology Topic: BATTERY Prepared by: Anjali Sharma Guide By: Jigna Parmar Shivani Gupta.
CHAPTER 18 & 19 ELECTRIC FIELD, ELECTRICAL ENERGY and CAPACITANCE.
Therapeutic Magnets. © 2005 – FA Davis Description Low-power magnets are placed on the patient’s body Static magnetic fields affect the tissues Normal.
Chemistry of Life Chapter 3 Biology Mr. Gilbertson.
PHARMACOKINETICS CH. 4 Part 2. GETTING IN ABSORPTION Definition – the movement of a drug from the site of administration into the fluids of the body.
Chapter 4 Pharmacokinetics Copyright © 2011 Delmar, Cengage Learning.
The properties of water Life depends on them!. Water is polar Covalent bond.
Polarization.
Chemical Elements and Water
Capillary Electrophoresis (CE) PHAR Lecture Objectives By the end of the lecture, students should be able to: 1.Illustrate the CE instrumental.
Chemistry of Life Chapter 2. Chemical Elements 2.1.
Tuesday, Feb. 22, PHYS Dr. Andrew Brandt PHYS 1444 – Section 02 Lecture #9 Chapter 24 Chapter 25 Tuesday Feb 22, 2011 Dr. Andrew Brandt.
Galvanic Body Treatment
The properties of water Life depends on them!. Water is polar Covalent bond.
Copyright 2004 © Mattioli Engineering All rights reserved Transdermal Delivery Technology.
Cells and Batteries An electrical battery is one or more electrochemical cells that convert stored chemical energy into electrical energy Cells are portable.
Chemistry of Life Chapter 2. Questions 1. What is the difference between an element and an atom? 2. What is makes up the mass of matter?
Shortwave Diathermy Clinical Application. Treatment Dosages Pulse DoseSensationWidthRate (pps) NTNo warmth65 µsec100 – 200 1Mild warmth100 µsec800 2Moderate.
Iontophoresis Chapter 6.
Ultrasound 10cm 2 Ultrasound (US) Therapeutic ultrasound –Uses acoustic energy, delivered at high frequencies for therapeutic purposes Electrical current.
Principles of Drug Action
Iontophoresis Dr/ Amal Mohamed Abd El Baky Mr. Chandrasekar.L
1. 2 Sylvia S. Mader Concepts of Biology © Zanichelli editore, 2012 Sylvia S. Mader Immagini e concetti della biologia.
Biochemistry Blank A little chemistry in Biology.
HYDROCOLLATOR Sekar.L INTRODUCTION  The use of moist heat as a therapeutic agent is one of the oldest forms of medicine.  Commercial hot packs is one.
CHIROPRACTIC PHYSIOLOGICAL THERAPEUTICS MIDTERM REVIEW COURSE #7402.
WELCOME TO THE SEMINAR ON
Chapter 3 PHARMACOKINETICS “What the body does to the drug” Lei Wang
Basic Chemistry, Electrochemistry & Corrosion Theory
Pharmacology I BMS 242 Lecture II (Continued)
Chapter 2 : The Chemistry of Life
Pharmacology I BMS 242 Lecture II (Continued)
Cells and Batteries.
Iontophoresis Vineela.U 08B21A0538 CSE.
Atoms, Molecules, and Life
Pharmacokinetics and Factors of Individual Variation
Drug Delivery Systems Pharmaceutical technology Petra University.
Electrochemistry Lesson 3
DRUGS USED IN CURRENT PHYSICAL THERAPY PRACTICE By Pashmina khan.
Presentation transcript:

Iontophoresis

Iontophoreis n Introduction of Ions Into The Body Using Direct Electrical Current n Transports Ions Across A Membrane Or Into a Tissue n It is a Painless, Sterile, Noninvasive Technique n Demonstrated To Have A Positive Effect On The Healing Process

Iontophoresis vs Phonophoresis n Both Techniques Deliver Chemicals To Biologic Tissues n Phonophoresis Uses Acoustic Energy (Ultrasound) To Drive Molecules Into Tissues n Iontophoresis Uses Electrical Current To Transport Ions Into Tissues

Pharmacokinetics of Ion Transfer Transdermal iontophoresis delivers medication at a constant rate so that the effective plasma concentration remains within a therapeutic window for an extended period of time.  Therapeutic window - the plasma concentrations of a drug which should fall between a minimum concentration necessary for a therapeutic effect and the maximum effective concentration above which adverse effects may possibly occur.

Pharmacokinetics of Ion Transfer Iontophoresis appears to overcome the resistive properties of the skin to charged ions Iontophoresis decreases absorption lag time while increasing delivery rate when compared with passive skin application Iontophoresis provides both a spiked and sustained release of a drug reducing the possibility of developing a tolerance to drug

Pharmacokinetics of Ion Transfer Rate at which an ion may be delivered is determined by a number of factors  The concentration of the ion  The pH of the solution  Molecular size of the solute  Current density  Duration of the treatment

Pharmacokinetics of Ion Transfer Mechanisms of absorption of drugs administered by iontophoresis similar to administration of drugs via other methods Advantages of taking medication via transdermal iontophoresis relative to oral medications  Concentrated in a specific area  Does not have to be absorbed within the GI tract  Safer than administering a drug through injection

Movement of Ions In Solution n Ionization- Soluable compounds dissolve into ions suspended in solutions that are called electrolytes n Electrophoresis- Movement of ions in solution according to the electrically charged currents acting on them.

Movement of Ions In Solution n Cathode = Negatively charged electrode  Highest concentration of electrons  Repels negatively charged ions  Attracts positively charged ions  Accumulation of negatively charged ions in a small area creates an acidic reaction

Movement of Ions In Solution n Anode = Positively charged electrode  Lower concentration of electrons  Repels positively charged ions  Attracts negatively charged ions  Accumulation of positively charged ions in a small area creates an alkaline reaction

Movement of Ions In Solution n Positively charged ions are driven into tissues from positive pole n Negatively charged ions are driven into tissues from negative pole n Knowing correct ion polarity is essential

Movement of Ions In Tissue Force which acts to move ions through the tissues is determined by  Strength of the electrical field  Electrical impedance of tissues to current flow

Movement of Ions In Tissue Strength of the electrical field is determined by the current density  Difference in current density between the active and inactive electrodes establishes a gradient of potential difference which produces ion migration within the electrical field  Active electrode- the one being used to drive the ion into the tissue

Movement of Ions In Tissue Current density may be altered by  Increasing or decreasing current intensity  Changing the size of the electrode Increasing the size of the electrode will decrease current density under that electrode.

Movement of Ions In Tissue Current density should be reduced at the cathode (negative electrode) Alkaline reaction (+ions) is more likely to produce tissue damage than acidic reaction(- ions) Thus negative electrode should be larger (2x) to reduce current density.

Movement of Ions In Tissue Higher current intensities necessary to create ion movement in areas where skin and fat layers are thick further increasing chance of burns around negative electrode Sweat ducts are primary paths by which ions move through the skin and act to decrease impedance facilitating the flow of direct current as well as ions

Movement of Ions In Tissue The quantity of ions transferred into the tissues through iontophoresis is directly proportional to  Current density at the active electrode  Duration of the current flow  Concentration of ions in solution

Movement of Ions In Tissue Once the ions pass through skin they recombine with existing ions and free radicals in the blood thus forming the necessary new compounds for favorable therapeutic interactions

Iontophoresis Techniques

Iontophoresis Generators  Produce continuous direct current *  Assures unidirectional flow of ions – *One study has shown that drugs can be delivered using AC current

Iontophoresis Generator  Intensity control  1 to 5 mA  Constant voltage output that adjusts to normal variations in tissue impedance thus reducing the likelihood of burns  Automatic shutdown if skin impedance reduces to preset limit

Iontophoresis Generator  Adjustable Timer  Up to 25 min

Iontophoresis Generator  Lead wires  Active electrode  Inactive electrode

Current Intensity Low amperage currents appear to be more effective as a driving force than currents with higher intensities Higher intensity currents tend to reduce effective penetration into the tissues Recommended current amplitudes used for iontophoresis range between 3-5 mA

Current Intensity Increase intensity slowly until patient reports tingling or prickly sensation If pain or a burning sensation occur intensity is too great and should be decreased When terminating treatment intensity should be slowly decreased to zero before electrodes are disconnected

Current Intensity Maximum current intensity should be determined by size of the active electrode Current amplitude usually set so that current density falls between mA/cm 2 of the active electrode surface

Treatment Duration Treatment duration ranges between minutes with 15 minutes being an average Patient should be comfortable with no reported or visible signs of pain or burning Check skin every 3-5 minutes looking for signs of skin irritation Decrease intensity during treatment to accommodate decrease in skin impedance to avoid pain or burning

Traditional Electrodes Older electrodes made of tin, copper, lead, aluminum, or platinum backed by rubber Completely covered by a sponge, towel, or gauze which contacts skin Absorbent material is soaked with ionized solution Ion ointment should be rubbed into the skin and covered by some absorbent material.

Commercial Electrodes Sold with most iontophoresis systems Electrodes have a small chamber covered by a semipermiable membrane into which ionized solution may be injected The electrode self adheres to the skin

Electrode Preparation To ensure maximum contact of electrodes skin should beshaved and cleaned prior to attachment of the electrodes Do not excessively abrade skin during cleaning since damaged skin has lowered resistance to current and a burn might occur more easily

Electrode Preparation n Attach self-adhering active electrode to skin

Electrode Preparation n Attach self-adhering active electrode to skin n Inject ionized solution into the chamber

Electrode Preparation n Attach self-adhering active electrode to skin n Inject ionized solution into the chamber n Attach self-adhering inactive electrode to the skin and attach lead wires from generator to each

Electrode Placement n Size and shape of electrodes can cause variation in current density (smaller = higher density) n Electrodes should be separated by at least the diameter of active electrode  Wider separation minimizes superficial current density decreasing chance for burns

Selecting the Appropriate Ion Negative ions accumulating at the positive pole or anode  Produce an acidic reaction through the formation of hydrochloric acid  Produce softening of the tissues by decreasing protein density-useful in treating scars or adhesions  Some negative ions can also produce an analgesic effect (salicylates)

Selecting the Appropriate Ion Positive ions that accumulate at the negative pole  Produce an alkaline reaction with the formation of sodium hydroxide  Produce hardening of the tissues by increasing protein density

Selecting the Appropriate Ion n Inflammation  Dexamethasone (-)  Hydrocortisone (-)  Salicylate (-) n Spasm  Calcium (+)  Magnesium(+) n Analgesia  Lidocaine (+)  Magnesium (+) n Edema  Hyaluronidase(+)  Salicylate (-)  Mecholyl(+) n Open Skin Lesions  Zinc(+) n Scar Tissue  Chlorine(-)  Iodine(-)  Salicylate(-)

Treatment Precautions Problems which might potentially arise from treating a patient using iontophoresis may for the most part be avoided if the athletic trainer  Has a good understanding of the existing condition which is to be treated  Uses the most appropriate ions to accomplish the treatment goal  Uses appropriate treatment parameters and equipment set-up

Chemical Treatment Burns Most common problem is a chemical burn which occurs as a result of direct current itself and not because of the ion being used  Continuous direct current creates migration of ions which alters the normal pH of the skin  Chemical burns typically result from accumulation of sodium hydroxide at cathode  Alkaline reaction causes sclerolysis of local tissues  Decreasing current density by increasing size of cathode can minimize potential for chemical burn

Thermal Treatment Burns Thermal burns may occur due to high resistance to current flow created by poor contact of the electrodes with the skin  Electrodes are not moist enough  Wrinkles in the gauze or paper towels impregnated with the ionic solution  Space between the skin and electrode around the perimeter of the electrode  Body weight resting on top of electrode