Latin America Training. ROSS Electrodes Training.

Slides:



Advertisements
Similar presentations
HORIBA Portable Meter Line-up
Advertisements

HA H + + A - B + H + BH + Acid Base Conjugate Base Conjugate Acid acid: donates protons (H + ) base: accepts protons (H + ) strong acid/base completely.
Water Quality Testing Made Easy GPS Aquameter and Multiparameter Aquaprobe The perfect solution for your water quality testing needs.
IC Controls 855 & 802 ppm Dissolved Oxygen System pH / ORP Conductivity Dissolved Oxygen Chlorine Standards R1.0 © 2004 IC CONTROLS.
DRIP DISPERSAL SYSTEMS Problems and Solutions Presented by Keith Surface.
1. 2 ❶ A complete nipple drinker range -Nipples: -2 activation ways: Feather Soft + Vertical -2 types of housing: Metal + Plastic -2 flow rates: 130 ml/min.
IC Controls Quality Water Solutions for pH pH / ORP Conductivity Dissolved Oxygen Chlorine Standards R1.0 © 2004 IC CONTROLS Concerns.
Electrodes and Potentiometry
File Name: pH.pptFeb 2001 pH Theory Applied to Proper Hardware Selection.
Potentiometry. pH is a Unit of Measurement  pH = Power of Hydrogen (H + )  Defined as the Negative Logarithm of Hydrogen Ion Activity  pH = log (1/H.
The world leader in serving science Technical pH Seminar.
PH Study General Chemistry 101/102 Laboratory Manual University of North Carolina Wilmington.
1 AHT's Technology Amorphous material - a solid with the internal structure of a liquid. Created by accelerated cooling process (1,500,0000°C/sec) of the.
IC Controls 865 ppb Dissolved Oxygen System pH / ORP Conductivity Dissolved Oxygen Chlorine Standards ppb Galvanic Dissolved Oxygen.
Monroe L. Weber-Shirk S chool of Civil and Environmental Engineering pH measurements The probe, from chemistry to voltage to a number + + V.
PH probe
Monroe L. Weber-Shirk S chool of Civil and Environmental Engineering pH measurements The probe, from chemistry to voltage to a number + + V.
PH In the Laboratory. Ionization of Water Equllibrium Constant, K eq.
Sanitation and HACCP Monitoring with the LIGHTNING MVP BioControl Systems, Inc.
Sensor Systems for CPI Sensor Transmitter temperature sensors
Kuskokwim Watershed Council Water Quality Training Workshop
Electrochemistry in Today’s Lab FUEL ETHANOL LABORATORY CONFERENCE November 12, 2013 Don Ivy Western US and Canada Sales Manager Thermo Scientific – Orion.
© DIAMOND SA / / 1 DIAMOND AVIM Connector Fiber optic connector for aero-space applications.
Hanna Instruments International Sales Division July 2011.
South Fork Instruments Advances in pH/ORP Measurement – Polymeric Sensors Presented by John Daly South Fork Instruments.
IC Controls Quality Water Solutions for pH pH / ORP Conductivity Dissolved Oxygen Chlorine Standards R1.0 © 2004 IC CONTROLS Concerns.
Nutrition for a Healthy Lifestyle. Objectives Upon completion of this session, you will: Understand the components and importance of a healthy diet Learn.
2005 Planning Meeting Introducing the WCP Range The New Standard in Call Point Technology.
Aqueous Corrosion Data Corrosion performed with ~1cm 3 samples in 100mL of DI water, 1mM NH 4 OH, or 1mM HCl The lowest dissolution rates occur at neutral.
VULCAN ENGINEERING LIMITED VISIT OUR TELEPHONE : +44 (0) FAX : +44 (0)
Today’s topic RTD D1&D2 Today I will talk about something of RTD and use D1 light to take the AFP Sweep.
Endura pH TBX587 Retractable Sensor
1 pH observed with Honeywell pH electrodes Current Plan for Calibration and Cleaning Gel replacement Checking with Buffers pH: SATURN-03; SATURN-04.
THE MEASUREMENT OF pH. I GENERAL PRINCIPLES Convenient way to express hydrogen ion concentration, or acidity pH = - log[ H +
Energy and Matter Including Unique Water Properties.
Optimization of the production and insertion of 3-dimensional polyimide electrodes into rats Lab of Professor Patrick Rousche Hananeh Esmailbeigi Daniela.
Lab Equipment. Beaker Holding liquids may be graduated (sometimes in two directions) has a white spot for labeling various sizes including 50, 150, 250,
Beaker Beakers hold solids or liquids that will not release gases when reacted or are unlikely to splatter if stirred or heated.
FlexLink – your dairy production logistics expert New levels for dairy production logistics.
Lab Equipment. Beaker Holding liquids may be graduated (sometimes in two directions) has a white spot for labeling various sizes including 50, 150, 250,
Selling Against Belanger Touch Free February 23, 2006.
Potentiometric titrations. Principle It mesures the change in potential, can be used for all kinds of titration : It mesures the change in potential,
Lab Equipment Subtitle. Beakers and Graduated Cylinders Beakers hold solids or liquids that will not release gases when reacted or are unlikely to splatter.
Ch. 4. Measurements (on Site) in Field  pH 와 E H  Basic water quality parameters  Definitions  pH = -log 10 a H+ (logarithmic value of the reciprocal.
Free Residual Chlorine Measurement
Commercial Use of Enzymes
Ch. 21 Potentiometry 1. General principles
PH meter Bushra mubarak. pH pH is defined as the negative logarithm of the hydrogen ion activity aH. Unit of measure which describes the degree of acidity.
POTENTIALS AND THERMODYNAMICS OF CELLS (1) POTENTIALS AND THERMODYNAMICS OF CELLS (1)
Air condition installation
By Suhas Dhenge.  To study the electrical activity of individual cell microelectrodes are employed.  This type of electrode must be small with respect.
Experiments in Analytical Chemistry
Preventative Maintenance For Water Treatment Systems Presented by:
Magnetic Drilling Machines
Conductivity Lecture.
Designed to win the air-cooled market!
Acid - Base Titrations They are an application of acid-base neutralization reactions that require the use of an indicator. 1.
Applied to Proper Hardware Selection
PH meter.
New Air Handler Platform
Properties of Water! Why Water is Special.
Electrode Training HORIBA Instruments, Inc. Pamela Millett Scientific
YES Background Knowledge Quality Management
HORIBA Portable Meter Line-up
Electrodes: 3 types Types: Micro electrode Depth & needle electrodes
Intellical Red-ROD technology
Chapter 23 Potentiometry.
Chapter – Properties of Water.
Custom Switch and Value Added Capabilities
Presentation transcript:

Latin America Training

ROSS Electrodes Training

3 ROSS Electrodes Premium pH electrode available Specially formulated reference system provides quickest response at temperature changes Offer less drift and greater stability than other pH electrodes Double junction reference system Can be used with biotech & TRIS samples Ability to use different fill solutions based on sample composition Environmentally friendly Also available as Triode

4 ROSS Electrode Specifications Drift: Less than pH units/day, minimizes restandardization Accuracy of measuring a pH 6.86 buffer after standardization at 25°C: Accurate within 0.03 pH for buffer at any temperature between °C using automatic temperature compensation. Speed of response in 6.86 buffer going from 25° C to 75°C: Response stable to 0.01 pH within 30 seconds. Speed of response between 6.86 and 4.01 buffers at 25°C: Response stable to pH within 15 seconds. Precision: 0.01 pH Triode temperature accuracy: Accurate to +/- 1 o C within 2 minutes

5 ROSS Temperature Response ROSS reference system uses iodide/iodine which is water soluble. ROSS reference system is independent of temperature changes. Platinum in reference system prevents junction problems caused in conventional electrodes by temperature changes

6 ROSS pH Electrode Families Standard ROSS electrodes Wide variety to choose from Meets all ROSS specifications 12 month warranty Available with BNC connectors, screw caps and US standard connectors ROSS Sure-Flow Unique free flowing junction prevents clogging 3 models to choose from Available mostly as BNC connector, but also EDIN ROSS Ultra Improved reference system Less drift than standard ROSS models Available with BNC only 24 month warranty

7 ROSS pH Electrode Families ROSS Ultra Triodes Newest Line of ROSS Only ROSS available as a low-maintenance electrode 4 models as epoxy refillable 4 models as epoxy gel 1 model to soon be released as glass refillable Different connectors for thermistor to fit different meters PerpHecT ROSS For use with LogR meters Utililize glass pH membrane to measure temperature Temperature accuracy of 0.5 o C Variety of models available Available only with BNC connector ROSS Micro 1 model with BNC connector For small sample size Also can be used with LogR meters

8 Reference junctions Used in ROSS Electrodes Ceramic – Used in most glass refillable electrodes Glass fiber – Used in most refillable epoxy electrodes Glass Capillary – New junction! Used in new ROSS gel triode

9 Reference junctions Used in ROSS Electrodes Sure-Flow – Glass to glass or glass to epoxy junction Glass sleeve – Specialty electrode, used in 8162SC

10 Electrode Connectors – BNC Connector Waterproof BNC US Standard Connector Screw Cap Electrode Pin Tip Connector (for reference half cell)

11 ROSS Half Cell Electrodes – Standard & Ultra Sure Flow Reference Electrode 8101BNWP pH Half Cell U ROSS Ultra Reference Electrode

12 Standard ROSS Line – Glass Electrodes 8102BN Standard size 120 X 12mm 8103BN Semi-Micro 6mm tip 8104BN Rugged bulb 8162SC Fixed glass sleeve titration joint 14/ BNWP Spear tip For piercing, cheese, fruits

13 Standard ROSS Line – Epoxy Electrodes 8115BN Semi-Micro 6mm tip 8135BN Flat surface For agar gel plates, cheese & meats Standard size for more rugged use

14 ROSS Sure-Flow Electrodes 8165BNWP Epoxy Body Standard size 120 X 12 mm Has replaceable bulb guard 8172BNWP Glass Body Standard size Has replaceable bulb guard 8175BNWP Epoxy body Semi-micro 8mm tip Has replaceable bulb guard

15 PerpHecT ROSS Line 8202BN Glass body Standard size 120 X 12mm 8203BN Glass Body Semi-Micro 6mm tip 8220BNWP Glass Body Micro tip 3mm diameter 8235BN Epoxy body Flat surface For moist surfaces 8272BN Glass Body Sure-Flow Has replaceable bulb guard 8256 Epoxy body Standard size

16 ROSS Ultra Electrodes 8102BNUWP Glass body Standard size 120 X 12mm 8103BNUWP Glass Body Semi-Micro 6mm tip 8104BNUWP Glass Body Rugged bulb 8115BNUWP Epoxy body Semi-micro 8mm tip 8156BNUWP Epoxy Body Standard Size 8135BNUWP Epoxy Body Flat Surface Standard Size

17 ROSS Ultra Epoxy Body Refillable Triodes Four models to accommodate different meters Faster temperature response that Ag/AgCl triodes Only ROSS electrodes not to have a coil 24 month warranty Performs extremely well in clean water samples Able to stand up to TRIS buffers with no effect on reference junction 8157BNUMD – For Star meters, 1 meter cable 8157UWMMD – For Star meters, 3 meter cable 8157BNU – For A+ meters, 1 meter cable 8257BNU – For PerpHecT meters, 1 meter cable

18 Orion Refillable ROSS Ultra Triode Strengths Placement and small-diameter design of the Orion ROSS Ultra Triode thermistor makes the temperature response fast and accurate. The ROSS reference system makes the electrode pH response very accurate, fast, and reproducible at elevated temperatures and after use in elevated temperatures. Junction testing shows the linear flow glass fiber reference junction performs well: has low stir potential and accurate response upon changing the ionic strength of the sample. It does not clog when soaked in Tris Buffer solution. The epoxy body is durable and protects the glass bulb from damage The refillable Orion ROSS Ultra Triode is the star performer in clean water samples (tap and DI tested) – fast, stable, accurate. Even when cycled with a strong acid, strong base, and high ionic strength pH buffer 6.86, response is quick, stable, and accurate. It also performs well in Tris Buffer at 37C and in creamy salad dressing at 35C.

19 ROSS Ultra Epoxy Body Low-Maintenance Triodes Four models to accommodate different meters Faster temperature response that Ag/AgCl manuals Only ROSS electrodes not to have a coil Only low-maintenance ROSS electrodes Superior performance to competitors in low ionic strength solutions More accurate and stable than competitors electrodes at temperature extremes 18 month warranty 8107BNUMD – For Star meters, 1 meter cable 8107UWMMD – For Star meters, 3 meter cable 8107BNU – For A+ meters, 1 meter cable 8207BNU – For PerpHecT meters, 1 meter cable

20 Competitive Comparison of Gel ROSS Ultra™ Triode in Low Ionic Strength Standard Low Ionic Strength Standard has expected pH value of at 0 o C to 30 o C The Gel ROSS Ultra Triode has superior performance in the low ionic strength solutions; it demonstrated better accuracy and response time than the other electrodes

21 pH Response in pH 4 Buffer at Different Temperatures Two ROSS Gel Triodes read close to each other and close to the expected values at about 10 o C, 55 o C, and again at 23 o C. Brand B is good except at cold temp., when readings deviated from the expected value (about 0.05 pH). Brand C is less accurate when reading buffers at different temperatures; it has large deviations at cold temp (about 0.2 pH) and after return to RT (>0.1pH).

22 Temperature Response at ~55C ROSS Triodes are faster at elevated temperature: they reached stable temp. readings in 30 seconds. It takes about 2 min. for Brand B and more than 5 min. for Brand C electrode to reach stable temperature readings at ~ 55C.

23 ROSS Ultra Glass Triode Just released in July model for Star meters, 8302BNUMD First Orion glass triode Temperature response faster than most glass triodes on market New ceramic junction

24 ROSS Electrodes Thank you to Gayle Gleichauf and Nadia Vilissova for graphs and competitive testing data of ROSS refillable and low maintenance Triode Thank you!