New electrode materials for H 2 O 2 New electrode materials for H 2 O 2 based sensors and biosensors Francesco Ricci 1, Carla Gonçalves 2, Giuseppe Palleschi.

Slides:



Advertisements
Similar presentations
Department of Chemical Engineering Nara National College of Technology Takanori KOBAYASHI, Atsuhiro KAWAMURA, Katsumi KATAKURA, Hirohisa YAMADA Electrochemical.
Advertisements

Capability of Immobilisation techniques and detection of Ab-Ag interactions by Eyad Hamad November 2010.
Summary of Potentiometry:
Lecture 6a Cyclic Voltammetry.
On-line Glucose Measurement in Disposable Bioreactors Michael Hartlep and Wolfgang Künnecke INTRODUCTION The use of disposables in biopharmaceutical processes.
Enzyme Engineering 8. Applications(2): Sensor & Fuel Cell
Alcohol Dehydrogenation Catalysts Bound to Fuel Cell Electrodes Tova Sardot and Dr. Eric Kelson Sigma Xi Symposium 2005 California State University, Northridge.
VOLTAMMETRY A.) Comparison of Voltammetry to Other Electrochemical Methods 1.) Voltammetry: electrochemical method in which information about an analyte.
Fabrication of a Microelectrode Array Biosensor Based on a Modified Enzyme-Chitosan Biocomposite Lorenzo D’Amico October 1, 2008.
Enhanced Electrochemical Reduction of Hydrogen Peroxide at Surfactant/Salt Modified Electrodes Laura Gonzalez-Macia 1, Malcolm R. Smyth 2 and Anthony J.
© Sauvé 2002 Sébastien Sauvé Department of Chemistry Université de Montréal Metal speciation using ion-selective electrodes.
Dr. Marc Madou, UCI, Winter 2012 Class V Potentiometric and Amperometric Sensors (I) Electrochemistry MAE-295.
Cholesterol biosensors have recently gained much attention due to the high rate of clinical disorders, such as heart disease, coronary artery disease,
The Detection of Hydrogen Peroxide and Glucose for the Electrode Modified with Ferrocene Yi-Sheng Wang ( 汪乙生 ), Ting-Li Lin ( 林庭立 ), Hau Lin ( 林浩 ) Department.
Ionic Liquids: A New Class of Sensing Materials Linlin Zhao Bioanalytical Chem, Spring 2007, UConn.
Amperometric Biosensors. Introduction Enzyme Catalyzed redox reactions The function of the enzyme is to generate or consume an electroactive species in.
ANALYTICAL CHEMISTRY CHEM 3811 CHAPTER 15 DR. AUGUSTINE OFORI AGYEMAN Assistant professor of chemistry Department of natural sciences Clayton state university.
The purpose of this work was the development of a disposable electrochemical immunosensor based on screen-printing technology for measurement of AFM1 in.
Carbon Nanotubes as Biosensors ME 695 Yang 11/30/2004.
Comparison of Field Emission Behaviors of Graphite, Vitreous Carbon and Diamond Powders S. H. Lee, K. R. Lee, K. Y. Eun Thin Film Technology Research Center,
The Redox Behaviour of Diazepam (Valium®) using a Disposable Screen- Printed Sensor and Its Determination in Drinks using a Novel Adsorptive Stripping.
Voltammetry: A Look at Theory and Application Bobby Diltz 14 March 2005.
Preparation of the Carbon Paste Electrode Modified with Ferrocene and Its Applications to Detection of Hydrogen Peroxide and Glucose Yi-Sheng Wang ( 汪乙生.
A Study of the Effect of Operating Potential on Detection of Hydrogen Peroxide for the Electrode Modified with Ruthenium Hexacyanoferrate Kuo-Hsiang Liao.
NOVEL NON-CONDUCTING FILMSFOR INTERFERENCE-FREE ELECTROCHEMICAL SENSORS M. BADEA a, A. CURULLI b*, G. PALLESCHI a, S. KACIULIS c, A. MEZZI c a Università.
A Study of Statistical Analysis of the Main Effects and Interaction Effects of Detection of Hydrogen Peroxide for the Carbon Paste Electrode Modified with.
The Optimum Operating Conditions for Detection of Hydrogen Peroxide for the Carbon Paste Electrode Modified with Ferrocene Pao-Tsai Kuo ( 郭寶財 ), Chung-Min.
An Analysis of the Effects of Detection of Hydrogen Peroxide for the Carbon Paste Electrode Modified with Ferrocene Pao-Tsai Kuo ( 郭寶財 ), Chung-Min Lien.
The Operating Potential on the Sensitivity of Detection of Hydrogen Peroxide for the Carbon Paste Electrode Modified with Ferrocene Pao-Tsai Kuo ( 郭寶財.
Microwave Assisted ZnO Nanorod Growth for Biosensing This material is based upon work supported by the National Science Foundation.
Institute of Organic Chemistry and Biochemistry AS CR, v.v.i. Czech University of Life Sciences Prague Jana Jaklová Dytrtová, Michal Jakl.
The Effect of Stirring Rate on the Detection of Hydrogen Peroxide for Carbon Paste Electrode Modified with Meldola’s Blue Chi-Wen Lo ( 羅濟玟 ), Chih-Ying.
An Analysis of Variance of Detection of Hydrogen Peroxide for Carbon Paste Electrode Modified with Copper Hexacyanoferrate Chia-Cheng Hsiao ( 蕭佳政 ), Chih-Ying.
Biosensors and Carbon Nanotubes
The Detection of Glucose for the Carbon Paste Electrode Modified with Ruthenium Hexacyanoferrate Kuo-Hsiang Liao ( 廖國翔 ), Chih-Ying Wu ( 巫致穎 ), Hau Lin.
The Operating Conditions for the Sensitivity of Detection of Hydrogen Peroxide for the Electrode Modified with Copper Hexacyanoferrate Chia-Cheng Hsiao(
Application of the Screen Printed Planar Electrode Modified with Ruthenium Hexacyanoferrate to Glucose Biosensor Kuo-Hsiang Liao( 廖國翔 ), Chung-Min Lien(
Section 13 Analytical Voltammetry.
Development of Affordable Bioelectronic Interfaces Using Medically Relevant Soluble Enzymes Brian L. Hassler 1, Maris Laivenieks 2, Claire Vieille 2, J.
C a p a 1 Universidade de São Paulo
Correlation between Nyquist plots for: (A) bare GCE and (B) SWCNT+PEI+HRP modified GCE in 10 mM K 3 [Fe(CN) 6 ] + K 4 [Fe(CN) 6 ], in phosphate buffer.
Introduction. During the last decade the interest in copper passivity significantly increased due to the important role of copper in microelectronic industry.
The Effect of Ratio of Meldola’s Blue to Carbon Powders and Carbon Paste on Detection of Hydrogen Peroxide for the Carbon Paste Electrode Modified with.
Electrode Array GK-12 Meeting November 2nd 2010
BIOFABRICATION OF MEA GLUCOSE SENSORS Dry in air Ready for in vitro glucose detection (B) Chitosan biopolymer is electrodeposited on target electrode sites;
Détection des insecticides organophosphorés et carbamates
The pH on the Sensitivity of Detection of Hydrogen Peroxide for the Small Electrode Modified with Meldola’s Blue Chi-Wen Lo ( 羅濟玟 ), Chung-Min Lien ( 連崇閔.
The pH on the Detection of Hydrogen Peroxide for Electrode Modified with Chromium Hexacyanoferrate Chen-Hsun Hu ( 胡真熏 ), Ting-Li Lin ( 林庭立 ), Hau Lin (
Introduction. During the last decade the interest in copper passivity significantly increased due to the important role of copper in microelectronic industry.
The Detection of Hydrogen Peroxide and Glucose for the Electrode Modified with Ruthenium Hexacyanoferrate Kuo-Hsiang Liao ( 廖國翔 ), Chung-Min Lien ( 連崇閔.
Advanced Biosensors Based on Nano-scaled Arrays and Films of Electro- and Biocatalysts Arkady A. Karyakin Chemistry faculty of M.V. Lomonosov Moscow State.
A Study of Carbon Paste Electrode Modified with Platinum Particles and Ferrocene and Its Application to Glucose Biosensor Yi-Sheng Wang ( 汪乙生 ), Ting-Li.
Competitive format ELECTROCHEMICAL IMMUNOSYSTEM FOR HEPATITIS A VIRUS DETERMINATION ELECTROCHEMICAL IMMUNOSYSTEM FOR HEPATITIS A VIRUS DETERMINATION L.
ELECTROCHEMICAL DETERMINATION OF URANIUM IN SALINE SOLUTIONS Matthew Kirby, 1 Pascal Salaun, 2 Jonathan Watson, 1 and Dominik Weiss. 1 1 Department of.
Introduction Lei, Yang; Luo, Ning. A highly sensitive electrochemical biosensor based on zinc oxide nanotetrapods for L-lactic acid detection. Nanoscale,
Design and Fabrication
Electrochemistry MAE-212
RESULTS AND DISCUSSION
Lecture 7a Cyclic Voltammetry.
Introduction Aim of study
Chen-Hsun Hu (胡真熏) , Chih-Ying Wu (巫致穎) , Hau Lin (林浩)
Synthesis and Characterization of ZnO-CdS Core-Shell Nanohybrids by Thermal Decomposition Method and Studies on Their Charge Transfer Characteristics Rama.
NiO2 mediator in catalytic oxidation of 2-propanol on glassy carbon
Electrode Measurements – Ch 15
s Changes: Cite figures under EIS
Joy Qiu ♦ Dr. Greg Swain ♦ HSHSP 2014
Complex Anode Kinetics Chronocoulometry Evidence
Catalyst coated membrane for zero-gap alkaline water electrolyzer
Cyclic Voltammetry Dr. A. N. Paul Angelo Associate Professor,
Volume 4, Issue 1, Pages (January 2018)
Presentation transcript:

New electrode materials for H 2 O 2 New electrode materials for H 2 O 2 based sensors and biosensors Francesco Ricci 1, Carla Gonçalves 2, Giuseppe Palleschi 1, Aziz Amine 3, Danila Moscone 1 1 Dipartimento di Scienze e Tecnologie Chimiche, Università “Tor Vergata”, Roma, Italia 2 Departamento de Química, Faculdade de Ciências e Technologia, Universidade de Coimbra, Coimbra, Portugal 3 Facultè de Sciences et Techniques, Universitè de Mohammadia, Mohammadia, Morocco Conclusions The novel Prussian Blue deposition on Screen Printed Electrodes and Glassy Carbon Paste Electrodes resulted in effective sensors for H 2 O 2 detection, with improved stability at alkaline pH’s, high sensitivity and low electrochemical interference. These characteristics make these sensors the ideal support of enzyme immobilisation for the assembling of an “oxidase” based biosensor. Choline Biosensors realised immobilising choline oxidase onto PB-SPE showed a low detection limit and a good reproducibility. A long-term storage and operational stability, due to the proposed immobilisation procedure, has been also observed. The new GCPEs showed after PB deposition an electrochemical behaviour better than classic Carbon Paste electrodes. Glucose biosensors prepared by hand mixing glucose oxidase within the PB-Glassy Carbon Paste mixture showed a good sensitivity and promising features for further experiments. Prussian Blue Modification by chemical deposition: FeCl 3 + K 3 Fe(CN) 6 20 µl K 3 Fe(CN) 6 10 mmol l µl FeCl 3 10 mmol l min at C 1 g. of Glassy Carbon powder in a solution of: FeCl 3 5 mmol l -1 + K 3 Fe(CN) 6 5 mmol l -1 Filtration 90 minutes at C INTRODUCTION: Prussian Blue or Exacyanoferrate ferric has been selected as catalyst for the H 2 O 2 reduction in order to obtain a reliable, selective and interferences free tool for H 2 O 2 detection. Two electrode materials have been used: Screen Printed Electrodes (SPE’s) Glassy Carbon Paste Electrodes (GCPE’s)  Disposable  Cheap  For “in situ” use  Ag Internal pseudo-reference electrode;  Graphite working electrode;  Ag Counter-electrode; 3 mm INTRODUCTION: Prussian Blue (Ferric Hexacyanoferrate) has been selected as catalyst of the H 2 O 2 reduction to obtain a reliable, selective and interferences free device for H 2 O 2 detection. Two new electrode materials have been used: Glassy Carbon Paste: 80% of Glassy carbon spherical powder ( µm) + 20% of Mineral Oil  Renewable surface  Easy to modify and prepare  High electrochemical activity Teflon Tube Pt Connector Improved stability at alkaline pH’s for PB modified electrodes E (V) vs. int. ref. i (mA) Continuous cycling in phosphate buffer 0.1 mol l -1 + KCl 0.1 mol l -1 First cycle 250 th cycle pH 9 Amperometric signal for H 2 O 2 10 µmol l -1 after 250 cycles 90% of the initial value E (V) i (mA) Continuous cycling in phosphate buffer 0.1 mol l -1 + KCl 0.1 mol l -1 for PB-GCPE (Glassy carbon mixture = GC/PBGC 90/10 w/w%) First cycle 250 th cycle pH 9 Amperometric signal for H 2 O 2 10 µmol l -1 after 250 cycles 75% of the initial value Analytical parameters of PB-SPE to H 2 O 2 Batch analysis applied potential -50 mV vs int. ref. Detection limit0.1 µmol l -1 Linearity range µmol l -1 RSD% (n= 7 elctrodes) 5% Response time (90%) 5 sec Sensitivity (µA mmol l -1 cm -2 ) 324 Ascorbic acid/H 2 O 2 signal ratio i (  A) [H 2 O 2 ] (mmol l -1 ) PB modified Screen Printed Electrodes Prussian Blue modified electrode Prussian Blue modified electrode in H 2 O 2 (10 mM) Non modified electrode When the electrode is modifed with PB the two anodic and cathodic peaks due to the oxidation and reduction of PB are present. In presence of H 2 O 2 an increase of the cathodic peak at potential near to 0.0 V is observed due to the reduction of H 2 O 2 CV in phosphate buffer 0.1 mol l -1 + KCl 0.1 mol l -1, pH E (V) i (A) 0 CV in phosphate buffer 0.1 mol l -1 + KCl 0.1 mol l -1, pH 6 Glassy Carbon mixture Composition GC /PB-GC a) 0/100 b) 25/75 c) 50/50 d) 75/25 e) 90/10 f) 95/5 g) 98/2 h) 100/0 w/w % Glassy carbon paste: 80% glassy carbon mixture + 20% mineral oil 1  A g 0.1  A h 5  A e 1  A f 10  A d 25  A b a c E (V) 10  A Best paste composition: 90/10 GC/PB-GC w/w % (e)  Low  Ep value  High peak currents  High response to H 2 O 2 Applied for H 2 O 2 detection and oxidase enzyme modification Prussian Blue modified Glassy Carbon Paste Electrodes PB Glassy carbon Paste Electrode (PB-GCPE) was first obtained by hand mixing PB glassy carbon and mineral oil (80/20 w/w %) N.B.  No anodic and no cathodic peaks probably due to the high amount of deposited PB (non conducting) The composition was optimised by decreasing the amount of PB-modified GC  A 0.5 CV in phosphate buffer 0.1 mol l -1 + KCl 0.1 mol l -1, pH 6 E (V) i (µA) Detection limit0.5 µmol l -1 Linearity range µmol l -1 Response time15 sec. Sensitivity (µA mmol l -1 cm -2 ) 99 RSD% (n=3 electrodes)6% Analytical parameters for PBGCPEs to H 2 O 2 Batch analysis applied potential 0.0 V vs Ag/AgCl Analytical parameters Choline Biosensors A novel enzyme immobilisation technique is proposed: a solution of: Glutaraldehyde + Nafion + BSA + choline ox. is placed onto the PB modified electrode Detection limit0.5 µmol l -1 Linearity range µmol l -1 Response time5 sec. RSD% (n=8 biosensors)6% Sensitivity (µA mmol l -1 cm -2 ) 110 Batch analysis applied potential -50 mV vs int. ref. Glucose biosensor Glucose biosensors were obtained by hand mixing 7.5% PB-GC % GC + 5% glucose oxidase and then mixing with mineral oil 80/20 w/w % Detection limit50 µmol l -1 Linearity range µmol l -1 Response time30 sec. RSD% (n=3 biosensors)4 % Sensitivity (µA mmol l -1 cm -2 ) 6.4 Analytical parameters Batch analysis applied potential 0.0 V vs Ag/AgCl Storage stability Operational stability Storage condition Numberof sensors Time Measurements frequency Residual activity (%) 4°C20 30 weeks Every 2 weeks 90  11 4°C49monthsEvery month 87  3 RT37daysEvery day 90  5 RT228days Every 3 days 95  10 number of measurements % of initial signal , , ,  = 4 different choline biosensors