THE COMPLETE ELECTRODE MODEL FOR IMAGING AND ELECTRODE CONTACT COMPENSATION IN ELECTRICAL IMPEDANCE TOMOGRAPHY G. Boverman 1, B.S. Kim 1, T.-J. Kao 3,

Slides:



Advertisements
Similar presentations
Image Selection T1 and T1 phantom images based on colin27 are used Segmentation Segmentation was performed using BrainSuite Finite Element Mesh Generation.
Advertisements

Chapter 6 Electrostatic Boundary-Value Problems
Chapter 8 Elliptic Equation.
Inverse problem of EIT using spectral constraints Emma Malone 1, Gustavo Santos 1, David Holder 1, Simon Arridge 2 1 Department of Medical Physics and.
Advanced Site Monitoring and Characterization of Site Dynamic Properties Mourad Zeghal, Tarek Abdoun and Vicente Mercado Department of Civil and Envir.
Predicting the parameters of a prostate IMRT objective function based on dose statistics under fixed parameter settings Renzhi Lu, Richard J. Radke 1,
HOW A SILICON CHIP CAPTURES AN IMAGE
Developing Anatomically Realistic Biomechanical Models of the Breast: Tracking Breast Cancer Across Medical Images Presenting Author: V. Rajagopal Auckland.
La Parguera Hyperspectral Image size (250x239x118) using Hyperion sensor. INTEREST POINTS FOR HYPERSPECTRAL IMAGES Amit Mukherjee 1, Badrinath Roysam 1,
The Improved 3D Matlab_based FDFD Model and Its Application Qiuzhao Dong(NU), Carey Rapapport(NU) (contact: This.
1 Electrical Impedance Tomography with Tomosynthesis for Breast Cancer Detection Jonathan Newell Rensselaer Polytechnic Institute With: David Isaacson.
Slide# Ketter Hall, North Campus, Buffalo, NY Fax: Tel: x 2400 Control of Structural Vibrations.
ECE 530 – Analysis Techniques for Large-Scale Electrical Systems Prof. Hao Zhu Dept. of Electrical and Computer Engineering University of Illinois at Urbana-Champaign.
Stereo Algorithm Grimson’s From Images to Surfaces stereo algorithm Multi-resolution Proceed from coarse to fine level Assume 0 initial disparity — depth-dependent.
Engineering Data Analysis & Modeling Practical Solutions to Practical Problems Dr. James McNames Biomedical Signal Processing Laboratory Electrical & Computer.
PIERS, Hawaii, Oct Second Generation Microwave Imaging System: Phantom and Early Clinical Experience Paul M. Meaney, Dun Li, Qianqian Fang, Sarah.
Figure 1: Locations of rosette strain gauges (n = 10) on the cadaveric pelvis. * * * * * * * * * * G Figure 3: Fixture for loading the pelvis (A) actuator,
The Heat Conduction Equation P M V Subbarao Associate Professor Mechanical Engineering Department IIT Delhi An Easy Solution to Industrial Heat Transfer.
Solutions of the Conduction Equation P M V Subbarao Associate Professor Mechanical Engineering Department IIT Delhi An Idea Generates More Mathematics….
Neuroinformatics, the ICONIC Grid, and GEMINI Allen D. Malony University of Oregon Professor Department of Computer and Information Science Director NeuroInformatics.
Numerical modeling of the electromagnetic coupling effects for phase error correction in EIT borehole measurement Y Zhao1, E Zimmermann1, J A Huisman2,
Magnetic Resonance Electrical Impedance Mammography (MREIM) A new approach to breast cancer imaging Maria Kallergi, 1 John J. Heine, 2 and Ernest Wollin.
Articulating Confocal Endoscope for Imaging Cancers in vivo This work is supported in part by the Center for Subsurface Sensing and Imaging Systems, under.
Chapter 4 Linear Wire Antennas ECE 5318/6352 Antenna Engineering
Parameter selection in prostate IMRT Renzhi Lu, Richard J. Radke 1, Andrew Jackson 2 Rensselaer Polytechnic Institute 1,Memorial Sloan-Kettering Cancer.
Directors   Mark H. Holmes, Mathematics Chair   Robert L. Spilker, Biomedical Engineering Chair   Kenneth S. Manning, Links Technical Manager Rensselaer.
Two-Phase Heat Transfer Lab May 28-30, Analytical And Experimental Investigation of Evaporation from Porous Capillary Structures Presented to ONR.
ACRIN Breast Committee Fall Meeting : Comparison of Full-Field Digital Mammography with Digital Breast Tomosynthesis Image Acquisition in Relation.
Abstract : The quest for more efficient and accurate computational electromagnetics (CEM) techniques has been vital in the design of modern engineering.
Impedance Imaging for Breast Cancer Diagnosis Tzu-Jen Kao 1, Ning Liu 3, Hongjun Xia 1, Bong Seok Kim 1, David Isaacson 2, Gary J. Saulnier 3, Jonathan.
Presenter: Chuan Li Yang Dept of Electronic and Electrical Engineering.
Improving the object depth localization in fluorescence diffuse optical tomography in an axial outward imaging geometry using a geometric sensitivity difference.
Surface Reconstruction of Blood Vessels from 3D Fluorescence Microscopy Images Abstract This project aims at doing a surface reconstruction of 3D fluorescence.
Regional admittivity spectra with Tomosynthesis images for breast cancer detection Tzu-Jen. Kao 1, G. Boverman 1, J.C. Newell 1, D. Isaacson 2, G.J. Saulnier.
Nuclear Instrumentation Laboratory Federal University of Rio de Janeiro -BRAZIL X-ray Fluorescence and X-ray Transmission Microtomography Imaging System.
Medical Image Analysis Image Reconstruction Figures come from the textbook: Medical Image Analysis, by Atam P. Dhawan, IEEE Press, 2003.
Analysis and Design of Multi-Wave Dilectrometer (MWD) for Characterization of Planetary Subsurface Using Finite Element Method Manohar D. Deshpande and.
Istanbul Technical University Electromagnetic Research Group
Using Multi-Element Detectors to Create Optimal Apertures in Confocal Microscopy This work was supported in part by CenSSIS, the Center for Subsurface.
Model based approach for Improved 3-D Segmentation of Aggregated-Nuclei in Confocal Image Stacks R1 R2 Fundamental Science Validating TestBEDs L1 L2 L3.
EXTENSIBLE ELECTRICAL CAPACITANCE TOMOGRAPHY SYSTEM FOR GAS–LIQUID TWO-PHASE FLOW From S. Xin H. Wang, “Extensible electrical capacitance tomography system.
Suppression of the eyelash artifact in ultra-widefield retinal images Vanessa Ortiz-Rivera – Dr. Badrinath Roysam, Advisor –
Wang Chen, Dr. Miriam Leeser, Dr. Carey Rappaport Goal Speedup 3D Finite-Difference Time-Domain.
Figure 6. Parameter Calculation. Parameters R, T, f, and c are found from m ij. Patient f : camera focal vector along optical axis c : camera center offset.
Visualization of Tumors in 4D Medical CT Datasets Visualization of Tumors in 4D Medical CT Datasets Burak Erem 1, David Kaeli 1, Dana Brooks 1, George.
ACT4: A High-Precision, Multi-frequency Electrical Impedance Tomograph. Chandana Tamma 1, Ning Liu 1, G.J. Saulnier 1 J.C. Newell 2 and D. Isaacson 3.
Presenter : Yu-Chun Hua Presenter : Yu-Chun Hua Adviser : Dr. Ji-Jer Huang Adviser : Dr. Ji-Jer Huang Date : Date :
BIOFABRICATION OF MEA GLUCOSE SENSORS Dry in air Ready for in vitro glucose detection (B) Chitosan biopolymer is electrodeposited on target electrode sites;
CardioInspect Diagnostic and Monitoring Systems
Ultrasound Computed Tomography 何祚明 陳彥甫 2002/06/12.
Hemodynamically Constrained Dynamic Diffuse Optical Tomography Under Mammographic Compression Eleonora Vidolova 1, Dana Brooks 1, Eric Miller 2, Stefan.
Ultrasound Computed Tomography
The current density at each interfacial layer. The forward voltage is continuous at every point inside the body. A Layered Model for Breasts in Electrical.
Fast and parallel implementation of Image Processing Algorithm using CUDA Technology On GPU Hardware Neha Patil Badrinath Roysam Department of Electrical.
Evaluation of an Automatic Algorithm Based on Kernel Principal Component Analysis for Segmentation of the Bladder and Prostate in CT Scans Siqi Chen and.
Date of download: 6/23/2016 Copyright © ASME. All rights reserved. From: Design of Bioimpedance Spectroscopy Instrument With Compensation Techniques for.
A Study of Electrical Impedance Property of an L 2 ePt Electrode 1 Interdisciplinary Program, Bioengineering Major, Graduate School, Seoul National University,
Date of download: 9/17/2016 Copyright © 2016 SPIE. All rights reserved. Experimental layout. (a) Schematic of phantom showing the cross-sectional and overhead.
Tomography for Intraoperative Evaluation of Breast Tumor Margins:
An extension of Ramo's theorem to include resistive elements
Structure Similarity Index
T. E. Dyhoum1, D. Lesnic 1 and R. G. Aykroyd 2
Excitation based cone-beam X-ray luminescence tomography of nanophosphors with different concentrations Peng Gao*, Huangsheng Pu*, Junyan Rong, Wenli Zhang,
Tianshuai Liu1, Junyan Rong1, Peng Gao1, Hongbing Lu1
For Monochromatic Imaging
INSTRUMENTASI INDUSTRI
Fields and Waves I Lecture 19 K. A. Connor Y. Maréchal
Reza Firoozabadi, Eric L. Miller, Carey M. Rappaport and Ann W
Lattice (bounce) diagram
Fields and Waves I Lecture 25 K. A. Connor Course Review
Presentation transcript:

THE COMPLETE ELECTRODE MODEL FOR IMAGING AND ELECTRODE CONTACT COMPENSATION IN ELECTRICAL IMPEDANCE TOMOGRAPHY G. Boverman 1, B.S. Kim 1, T.-J. Kao 3, D. Isaacson 2, G.J. Saulnier 3, and J.C. Newell 1 Departments of 1 Biomedical Engineering, 2 Mathematical Sciences, and 3 Electrical, Computer and Systems Engineering, Rensselaer Polytechnic Institute, Troy, NY Introduction: Electrical Impedance Tomography (EIT) is an imaging modality which currently shows promise for the detection an characterization of breast cancer. A very significant problem in EIT imaging is the proper modeling of the interface between the body and the electrodes. We have found empirically that it is very difficult, in a clinical setting, to assure that all electrodes make satisfactory contact with the body. In addition, we have observed a capacitive effect at the skin/electrode boundary that is spatially heterogeneous. To compensate for these problems, we have developed a hybrid nonlinear-linear reconstruction algorithm in which we first estimate electrode surface impedances, using a Newton-type iterative optimization procedure with an analytically compute Jacobian matrix. We subsequently make use of a linearized algorithm to perform a three-dimensional reconstruction of perturbations in both contact impedances and in the spatial distributions of conductivity and permittivity. Results show that, using this procedure, artifacts due to electrodes making poor contact can be greatly reduced. References: Publications Acknowledging NSF Support: 1. Ning Liu, Gary J. Saulnier, J.C. Newell, D. Isaacson and T-J Kao. “ACT4: A High-Precision, Multi-frequency Electrical Impedance Tomography” Conference on Biomedical Applications of Electrical Impedance Tomography, University College London, June 22-24th, Choi, M.H., T-J. Kao, D. Isaacson, G.J. Saulnier and J.C. Newell “A Reconstruction Algorithm for Breast Cancer Imaging with Electrical Impedance Tomography in Mammography Geometry” IEEE Trans. Biomed. Eng. 54(4), Kim, B.S., G. Boverman, J. C. Newell, G.J. Saulnier, and D. Isaacson “The Complete Electrode Model for EIT in a Mammography Geometry” Physiol. Meas (in Press). 4. Boverman, G., B.S. Kim, D. Isaacson, and J.C. Newell, “The Complete Electrode Model for Modeling and Electrode Contact Compensation in Electrical Impedance Tomography”, submitted to the IEEE EMSB Conference, Others: 1. T. Vilhunen, J. P. Kaipio, P. J. Vauhkhonen, T. Savolainen, and M. Vauhkonen, “Simultaneous reconstruction of electrode contact impedances and internal electrical properties: I. Theory.,” Meas. Sci. Technol., 13, EIT and Tomosynthesis co-registered The ACT 4 system [1] is the electrical impedance imaging system being developed at Rensselaer. It is a high-speed, high-precision, multi-frequency, multi-channel instrument which supports 64 channels and electrodes. Each electrode is driven by a high precision voltage source, and has a circuit for measuring the resulting electrode current. These circuits are digitally controlled to produce and measure signals at 5k, 10k, 30k, 100k, 300k and 1MHz. The magnitude and phase of each source are controlled independently. The system has been used to study breast cancer patients at Massachusetts General Hospital in conjunction with a tomosynthesis machine and verified with biopsy results. The EIT images are co-registered with tomosynthesis images since the EIT electrodes are placed on the mammograph plates as shown. Importance of the work and technology transfer: The EIT clinical data and analysis in mammogram geometry provide a foundation to assess the value of EIT as an adjunct to mammography for breast cancer screening and diagnosis. This work is supported in part by CenSSIS, the Center for Subsurface Sensing and Imaging Systems, under the Engineering Research Centers Program of the National Science Foundation (Award Number EEC ) and by NIBIB, the National Institute of Biomedical Imaging and Bioengineering under Grant Number R01-EB Contact Info: Jonathan Newell, Ph. D. Research Professor of Biomedical Engineering Rensselaer Polytechnic Institute Web site: Eighth St. Troy, NY Phone : FAX : Idealized Model of Breast Geometry: Figure 2. The mammography geometry is modeled as a rectangular box with electrodes on the top and bottom planes. Figure 1. ACT 4 with the mammography unit ( top left), radiolucent electrode array [2] attached to the lower compression plate (upper right), one slice of the tomosynthesis image made with the electrode arrays in place of the left breast from human subject HS14 (lower left) and tomosynthesis image with an overlaid grid showing the location of the active electrode surfaces (lower right). Note that the copper leads and ribbon cables are visible on the left and right of the tomosynthesis images but the radiolucent portion of the arrays is not visible. Mathematical Formulation of the Complete Electrode Model: We use a series eigenfunction decomposition of the potential: The complete electrode model (CEM) specifies a set of boundary conditions for Eq. 1 that have been experimentally shown to be accurate in modeling the interface between highly conductive electrodes and a considerably less conductive medium. First of all, we know the total current injected through each electrode, and we assume that no current flows out through regions of the surface where electrodes are not present: In the quasi-static approximation of Maxwell’s equations, the potential within the body is governed by the following equation: In implementing the complete model, we make use of a Galerkin approach, in which, we have the condition that, for each test function, v, the following equation must be satisfied: Using the divergence theorem and applying the conditions of the CEM, we then find: Linearization and Reconstruction Using the divergence theorem applied to Eq. 1, we find that, for the potentials due to two current patterns Phantom Experiments: We tested the methods presented in this poster using a breast- shaped phantom: Figure 3. The 60-electrode test phantom for the 3-D mammography geometry used in the experiments. Figure 4. Relative norm error for the ave-gap and complete electrode models (saline tank). Figure 5. Compensation for a poorly contacting electrode using the CEM. (a) Difference imaging reconstruction (for reference). (b) Reconstruction using the CEM and estimated surface impedances. Figure 6. Reconstruction using an ave-gap model. Application to Clinical Data: (a)(b) (a)(b) (c) (d) (e) Figure 6. Estimation of surface impedances for patient 25, left breast. (a) Electrode test for ave-gap model. (b) Electrode test for CEM. (c) Real part of estimated surface impedances. (d) Imaginary part of estimated surface impedances. (e) Reduction in residual using the CEM and estimated surface impedances.