Electrocautery.

Slides:



Advertisements
Similar presentations
FHM TRAINING TOOLS This training presentation is part of FHM’s commitment to creating and keeping safe workplaces. Be sure to check out all the training.
Advertisements

Hazards Of Electricity
Introducing Electricity and Electrical Safety
Introducing Electricity and Electrical Safety
Electrical Safety Program. How Electricity Works Operating an electric switch is like turning on a water faucet. Behind the faucet or switch there must.
Electrical Safety.
Electrical Safety Basic Electrical Safety Rafael Coll, Environment Safety and Health Section Health& Safety Group Ext Pager: (630)
LAB SAFETY Objective(s): To review and summarize laboratory safety concepts and laboratory practices.
Classroom & Laboratory Safety
Two-mode Safety and Battery System Service
Surgical Diathermy Machine
Kenny Low Dec 2009 Urology registrar Thursday teaching
General Electrical Safety. Why is it so important to work safely with or near electricity? The electrical current in regular businesses and homes has.
Section 2 Safety, Tools and Equipment, Shop Practices Unit 4 General Safety Practices.
Better Safe Than Sorry A WORLD THAT STARTS WITH ELECTRICAL HAZARDS AND SAFETY. ELECTRICITY IS A VERY SERIOUS BUSINESS AND THE EFFECTS ON THE HUMAN, ELECTRICAL.
Copyright © 2014 Delmar, Cengage Learning Safety Instructor Name: (Your Name) 1 CHAPTER.
ELECTRICAL SAFETY Safety Training for the Non-Qualified.
Technician License Course Chapter 9 Lesson Module 20: Electrical Safety.
Technician License Course Chapter 9 Lesson Module 20: Electrical Safety.
Fire Electrical Back Security
ELECTRICAL SAFETY in the Lab ELECTRICAL SAFETY in the Lab C. Poole, REAG.
Module 1A: Safety and Health Alexander MacFarlane.
Safety Guidelines General Information Always get your TEACHER’S permission before beginning a Lab. Read the Lab before starting Look up unknown safety.
Safety Training For The Non-Qualified
Diathermy.
Electrical Safety.
Electrical Safety INSTRUCTOR’S NOTES:
CVT 102.  Electron Theory ◦ All electronic effects caused by movement of electrons ◦ Serves as basis for design of electrical equipment.
1 Electrical Safety. 2 Electrical Hazards & OSHA 29 CFR (b)(1) requires: “Electrical equipment shall be free from recognized hazards that are.
Electrical Safety INSTRUCTOR’S NOTES:
Without reference, identify principles about Electrosurgical Units with at least 70 percent accuracy.
Safety High Voltage Electricity and Water are a Dangerous Combination and is one of the greatest hazards students will encounter in these projects, therefore,
Do this now… Go to and complete the pre-lesson survey. Go to my eBoard and set up.
Copyright  Progressive Business Publications Electrical Safety.
Accommodation & Hospitality Services STAFF BRIEFING – No 16 Electrical Safety.
Shop Safety Electrical Hazards….  Even small electric shocks are dangerous  Many hazards include electrocution, fire, or explosions  Even small electric.
Fire Safety Month Fire Safety Tips for October Department of Risk Management James Madison University.
Chapter 7 Safety. Introduction This chapter covers the following topics: Dangers of electricity Preventive measures Electrostatic discharge Safety practices.
Mr. Banerjee’s Science Classroom 1 Lab Safety Pages
SAFETYSAFETY. Overview ●Introduction to Safety ●Potential Electronic Mishaps ●Safe Work Practices.
GENERAL SAFETY.
POWER TOOL SAFETY.
RDT Hospital, Dept of Gen Surgery
Electrical Safety, Subpart K
Technological Sciences for the Operating Room
Electrosurgical Unit.
ELECTRIC CHARGES. Charges Most objects contain billions of charges. Usually the number of positive charges equals the number of negative charges making.
 A medium that provides a means for transferring energy from one place to another  It is not expensive or difficult to control the risk of an electrical.
TOPIC: Lab Safety AIM: How do we practice safety in the science laboratory? DO NOW: Why is it important to follow safety rules?
HOUSE WIRING Final Review. Electricity Electricity = flow of electrons Conductor= electricity passes thru easily - Metal, water, person Insulator = restricts.
HOUSE WIRING NOTES. Electricity  Proton – positive charge  Electron – Negative charge  Electricity = flow of electrons Conductor= electricity passes.
SAFE USE OF DIATHERMY RACHEAL AFOLABI, RN, RM, H. Dip. PERI-OPERATIVE NURSING, H.Dip. HEALTH SYSTEM MANAGEMENT.
Safety Guidelines, Safe Work Habits, and First Aid Safety Guidelines, Safe Work Habits, and First Aid.
Electrical Safety Basic Electrical Safety. Electrical Safety  Course not designed to teach you to work on electrical equipment. Basic Electrical Safety.
ELECTRICAL SAFETY in the Lab. 1.Electricity takes the path of least resistance. 2.Electricity wants to go to ground. 3.If an electrical appliance or tool.
Using a Multimeter.
Electrical Safety and Safe Work Practices
Laboratory Safety: Electricity
Electrical Safety.
Classroom and Laboratory Safety
Basic Electrical Safety
HOME ELECTRICAL SAFETY
Classroom and Laboratory Safety
Shop Safety Electrical Hazards….
Safety in the Physics Laboratory
Basic Electrical Safety
Click anywhere to get started…
A. Touching both terminals with the hands can cause electrical shock
College of Dental Medicine
Presentation transcript:

Electrocautery

Terms Related to Electrocautery ECU electrocautery unit Cautery and Bovie are used interchangeably to describe the cautery pencil or active electrode FYI: Bovie is the originator of electrocautery surgery, hence called a “Bovie” sometimes Electro- (electrical/electricity) Cauterize (stoppage of bleeding)

Electricity Terms: Current, Volts, OHM’s Law Electrical Circuit Hot Wire -wire that connects to the switch Neutral Wire –serves as pathway for electrons to return to the energy source, completing the circuit Ground Wire – separate wire that safely conveys any leaking electrons to the ground, preventing injury to the patient or personnel Must have a ground wire to prevent electric shock Generally in wires: red = hot wire, green = neutral wire, black = ground wire

Electricity Terms: Current, Volts, OHM’s Law Wall Outlets 110V generally Mobile X-Ray = 220V Surgical outlet must have three prongs in surgery First prong (positive) Second prong (negative) Third prong (ground) Wall plates that are red are hooked up to the hospital generator and you will plug important electrical devices into those outlets that are vital to the patient and their surgery

Electricity Terms: Current, Volts, OHM’s Law Electrical Systems 1. DC (direct current) Flows in one direction from negative pole to positive pole Flashlight is an example of a DC system AC (alternating current) Flow of current reverses periodically One complete cycle occurs when the current moves in one direction then reverses its course One AC cycle is called a Hertz (Hz)

Electrosurgery Electrocautery and electrosurgery do not mean the same thing (will hear terms used interchangeably) ESU =’s cut and coag/ ECU =‘s coag ONLY Electrocautery is using a heated wire to burn the patient’s tissue (eye cautery) Uses DC current, no electricity enters the patient’s body

Electrosurgery Two types ESU: Bipolar and Monopolar Bipolar used for delicate procedures where there is moisture and a potential for nerve damage Active and Dispersive electrodes are the tines of a two prong forceps Monopolar is used for large surgical areas

Electrosurgery Application or use of an electrical current to cut or coagulate tissue Uses AC current ESU Components: Generator, optional foot pedal, cords, active electrode, and inactive dispersive electrode

Electrosurgery ESU Circuit: ESU generator Conductor cord Active electrode (pencil) Surgical site Patient (is part of circuit with bipolar) Dispersive electrode (grounding pad with monopolar other tine of forcep with bipolar) ESU Generator

Electrosurgery Hazards Burns to the surgeon, surgeon assistants, STSR Burns to the patient from poor grounding pad placement, pad becoming loose due to oils, hair, air pockets, or prep-solutions Cautery plume: vaporized tissue contains carcinogens, BBP, and mutagens Smoke evacuators should be used to counteract these hazards Contain an air and charcoal filter Charcoal absorbs odor and hydrocarbons Occupational hazard and patient hazard

Basic Electrical Safety Guidelines Remove jewelry when operating equipment Secure long hair and loose clothing around power equipment Wear PPE prn Use equipment for intended purpose only Never use equipment you are not trained to use Inspect equipment prior to use Disconnect power prior to maintenance on equipment TURN OFF equipment power prior to unplugging or plugging in equipment Never disconnect a plug by pulling on cord (pull on plug) Hands should be DRY prior to handling equipment or cords/plugs Keep equipment out of line of traffic to avoid injury to person or equipment Tape cords down to floor if they are in traffic to avoid tripping

Electrical Safety Guidelines Do not use electrical equipment when you’re touching metal or water Unplug electrical equipment before cleaning, inspecting, repairing, or removing anything from them Keep electrical equipment areas clean/free from flammable materials Keep access panels and junction boxes clear Know where fuse boxes and circuit breakers are Make certain all electrical equipment is grounded Do not use water on electrical fires Report unsafe conditions/equipment to supervisor or biomedical/engineering department stat (Know policy of institution regarding damaged equipment) Examples frayed cords, bent plugs, broken switches or outlet covers, smoking or sparking of equipemtn, extension cords in permanent use (should have equipment with proper cord length as JCAH do not recommend use of drop cords-fines involved if caught)ds

Valleylab Generator Features of the monopolar generator: Cutting and coagulation settings available Bipolar available on left of unit with separate settings Settings average on 0-50 cut and 30-70 coag (surgeon preference) Standard settings 30/30 Constant increase requests by surgeon mean something is wrong Troubleshooting problems: Tip must be checked, connections checked, if cannot resolve obtain a new bovie pencil first, change ground (circulator) change generator

Bovie scratch pad For non-teflon tips Teflon tip and bovie cleaner Bovie Pencil Bovie holster

Pediatric Grounding Pad Adult Grounding Pad

Disposable Ophthalmic Forceps Place in sharps container at end of case Non-disposable Tips Bayonet forcep McPherson’s bipolar forcep Disposable Ophthalmic Forceps Place in sharps container at end of case Bipolar Cautery Tips And disposable cord

EYE Cautery or High Temp Cautery Battery powered Used in Eye Surgery Peripheral vascular surgery When a hole is needed in a synthetic Dacron graft These cannot be cut as the material will fray, so hole may be burned to seal the area

Electrocautery Review Monopolar Current travels from generator, to active electrode (cautery pencil), to patient (wound), to inactive or dispersive electrode (grounding pad), back to generator… All components must be present to avoid injury to patient and to utilize device Grounding pad placement must be on a fleshy, non-hairy, non-moist area where it is firmly stuck to skin Ground is placed by circulator Bipolar Current travels tip (active electrode) to patient to tip (dispersive electrode) and is powered by a generator No grounding pad is needed Utilized when a precise cauterization is needed in delicate procedures such as ophthalmic and neurosurgical where precision is key Can have a bipolar with an irrigating port, seen most frequently in neuro procedures with a Bayonet style forcep (Malis Bipolar unit)

Monopolar Cautery Various tips available: long, short, needle tip, teflon coated Come in various colors depending on manufacturer May be hand cautery or foot pedal controlled Grounding pads must be appropriate size for patient (adult and pediatric available) NEVER cut a grounding pad!

Tourniquets Go to this site http://www.tourniquets.org and read: tourniquet overview use and care sections 2. Also read in Textbook St for the ST

Tourniquet Components Esmark Tourniquet Cuff (sterile disposable or clean non-disposable) Pneumatic tourniquet machine

Safety Precautions Tourniquet inflation times: 1 hour for upper extremities 1 ½ to 2 hours lower extremities Times exceeding these recommendations put the patient at risk for nerve damage and or tissue ischemia (poor oxygenation/vascular compromise) which can cause tissue necrosis Notify MD after tourniquet has been up for 1 hour. Tourniquets may be deflated for 10 minutes and then re-inflated if necessary

Safety Precautions Continued Tourniquet pressures: Must not exceed 50-75 mm/Hg over patient’s systolic blood pressure for upper extremities Must not exceed 100-150 mm/Hg over patient’s systolic blood pressure for lower extremities