Introducing… HVS4000 & HVS400 Toxic Gas Detectors from Halogen Valve Systems.

Slides:



Advertisements
Similar presentations
Prescient II Extinguishing Control Panels
Advertisements

… for Combustible Gas Detection S4000C Intelligent Sensors..
Sensor Operating Theory
DP-IR Detecto-Pak Infrared
GE job title/1 GE internal information - Not for external distribution 1 GE Security EMEA NPI template – v1 1X Series (phase 1) Conventional Fire Panel.
Dr C Narain Spantech Products, South Godstone, Surrey, UK The exclusive representative for ACD in Europe, Middle East and India.
Getting Started Product Description Setting Parameters How does it work Wiring Diagram.
1 Rev /02 Modular Construction Dual/Redundant CPU/Power Supply Support TCP/IP Communication Protocol 4096 Camera by 512 Monitor Switching English.
Company Confidential © 2005 All Rights Reserved. What is it? State-of-the-art: microprocessor-based, wall-mount gas monitor Easy installation and operation:
1 Hardy Process Solutions – New Product Introduction HI6600 Series – Modular Sensor System Hardy delivers productivity solutions to manufacturers and processors.
E VERY L IFE H AS A P URPOSE… Flame Detection Theory.
E VERY L IFE H AS A P URPOSE… FlameGard 5 UV/IR Flame Detector The Benefits of HART on Installation and Maintenance of Flame Detectors.
E VERY L IFE H AS A P URPOSE… Z Gard ® Family of Gas Detection Products.
Medical Gas Alarm Panels
Clean Air Box Usage & Care CABs RAMs CO Monitors.
MET ONE 7000 Series Remote Airborne Particle Counters Customer Name Date Presenter Presenter Title.
GST FIRE ALARM SYSTEM INTERNATIONAL BUSINESS DEPARTMENT , GST BEIJING
You Can Measure the Benefits… Training Course Introduction to SmartScan.
AT-LINE A Practical Application of Smart Modular Sampling Components IFPAC 2001 ABB.
AS-i, The Simplest Automation Networking Solution Dated: 10/30/2008.
(Smart Loop System) Installation Guide. Rev B Shipping Box Contains Everything that is included in the box being shipped to a customer should contain.
Gas Sensor and Transmitter
AccuMax Multi-Point Injection Mechanics
1  Module Type Overview  Construction  Characteristics  Installation principles  Details PD 600-Series.
Advantys® STB High Density Discrete I/O Modules. AGP - English 2 Advantys® STB Advantys STB delivers customer value in distributed I/O Smart Built-in.
The Impulse “Switch” 1Daniel Overman DIS5274/10/2010.
Ultima® X Series Gas Monitors
E VERY L IFE H AS A P URPOSE… Chillgard ® L Series Refrigerant Monitors.
What is the It is the Next Generation, Calibration Station for the GasBadge ® Plus Personal Monitor
All content in this presentation is protected – © 2008 American Power Conversion Corporation Symmetra ® LX – redundant UPS High performance, redundant.
Overview of the 1.
SCADA and Telemetry Presented By:.
TRANSMILLE PATs The New Alternative To Fast, Easy & Efficient Portable Appliance Testing.
GAS DETECTOR BY : SELAMAT SURIYADI.
E VERY L IFE H AS A P URPOSE… Chillgard ® RT Refrigerant Monitors.
BioWin ®. Bio Gas – The alternative energy source of the future! BioWin ® - Bio Gas Analysis of the future!
Smart transmitters.
1 PAC530 | Output Controller. 2 The Output Controller (PAC530) provides the local connection on an RS-485 network between an Access and Alarm Server (PAC500)
High Sensitivity Smoke Detection
An Introduction to the R3 19 inch Rack The R3 control system comprises a number of different plug in modules, each of which is dedicated to a particular.
Module 1: Introduction to PLC
Scout Pro Training Introducing the Scout Pro Portable Balance: 7 Models From 200g x 0.01g to 6000g x 1g 5 Application Modes Optional USB or RS232 Interface.
Gauge Operation and Software by Scott A. Ager. Computer Recommendations 750 MHz Pentium III 64 Meg SRAM 40 Gig Hard Drive 1024 x 768 graphics CD Writer.
LDA Large Display for Analog Inputs. Agenda What is the LDA? Easy programming About the input Setpoint control Communication Other features Packaging.
E VERY L IFE H AS A P URPOSE… Toxgard ® II Gas Monitor.
Ultima ® X Gas Monitor with HART Display Version.
HARDWARE TESTING OF DIGITAL INPUT & OUTPUT CARDS FOR DATA ACCUSITION & CONTROL SYSTEMS A Mini Project Report submitted in partial fulfillment for the award.
Codan 5700 Series C-Band Transceiver Technical Overview.
2 December, 2015 New Conventional Fire Control Panel.
E VERY L IFE H AS A P URPOSE… 9010 / 9020 Controller.
Digital Temperature Switches The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and.
Gas Transmitters The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and current employees.
Handheld Digital Manometers The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and current.
Gas Mass Flowmeters The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and current employees.
New Product Developments World Leaders in Combustion Management Solutions C.E.M.S., MCERTs & E.P.A. Exhaust Gas Analysers C.E.M.S., MCERTs.
New Product Developments World Leaders in Combustion Management Solutions C.E.M.S., MCERTs & E.P.A. Exhaust Gas Analysers C.E.M.S., MCERTs.
E VERY L IFE H AS A P URPOSE… Ultima ® XI Gas Monitor.
Lesson 2 Component Overview Core Hardware Fundamentals.
AEON 4000 Including the SMPS 4000 rectifier and the AEON Gold Alarm & Monitoring Unit.
CompactLogix Controllers Portfolio
GmbH Specialist hotel application ComplianceCommercial refrigeration Industrial refrigeration Light Industrial Gas Detection MGS-550 Product Portfolio.
USER GUIDE TEMPERATURE CONTROLLER TR-2006 Hot runner temperature controller ShenZhen TanRex Electronic Co.ltd.
MSA Passport  Personal Alarm Combustible gases and vapors Oxygen enriched Oxygen deficient Specific Toxic gases Alarm levels are set at the factory.
Digital Light Sources First introduced in 2001.
ControlLogix Portfolio
Gas Detection in Water Treatment
Enclosed Parking Ventilation 1 EK Engineering (India) CO/NO2 detection, Fan Control and automation System E: Mobile:
The FG series of explosive and toxic gas detectors and panels
Universal Interrupted Electronic Oil Primary R7184U Training Module
724 Temperature Calibrator
Presentation transcript:

Introducing… HVS4000 & HVS400 Toxic Gas Detectors from Halogen Valve Systems

Agenda Introduction to General Monitors –HVS4000 –HVS400 Features & Benefits Specifications Calibration Accessories Applications Competition Closed Loop Marketing Feedback/Questions PRODUCT LAUNCH

General Monitors Established in 1961 by Dr. Frank Linville Two Manufacturing facilities and R&D Sites - Lake Forest, CA and Ireland The Best Service & Customer Support World Class Automated Manufacturing Total Quality Management JIT Purchasing ISO-9001:2000 Status Worldwide Distribution Channels Advanced Proprietary Technologies for Catalytic Bead, Metal Oxide Semiconductor, Electro-chemical & Point and Open Path Infrared

HVS4000 at a Glance The HVS4000 is a +24VDC powered toxic gas detector comprised of a base unit, interface module (IM) and electrochemical cell Galvanically isolated intrinsically safe design of the (IM) module supports sensor field replacement without the need for special tools or hot work permits Complements our HVS400 Series products and provides a “Total Toxic Solution” for application in Chlorine rooms. Base Unit InterfaceModule EC Cell

Interface Module The HVS4000 Interface Module (IM) is encapsulated in an anodized aluminum housing enabling sensor information to be processed at the point of detection. The HVS4000 provides a 4-20mA output signal proportional to the gas concentration at the Base Unit IM Features: –Galvanically isolated Intrinsic Safety Barrier to the internal electronics of the IM –Electrical conditioning circuitry for the electrochemical cell –Mechanical and electrical interface for the electrochemical cell –Explosion proof conduit seal from the Base Unit to the IM –Explosion proof housing for the Intrinsic Safety Barrier –One I/O pair for digital serial communication to and from the Base Unit and IM –One +24VDC / COM GND pair for power into the Interface Module

Base Unit The HVS4000 Base Unit provides the display / control device for the entire HVS4000. The Base Unit is based on the proven Intelligent Sensor platform Base Unit Features: –Bright LED Digital Display (outdoor readable) –MODBUS Communications –High Rating Relays –One Activation Point for Settings/Calibration –Simplified Wiring and Field Connections –Standard Platform Calibration Prompts –Remote Sensor Placement Capability –Remaining Sensor Life Indicator –Low Total Cost of Ownership

Reference Electrode Target gas diffuses through the diffusion barrier limiting the amount of gas entering the sensor. It then diffuses through the gas permeable membrane until it reaches the sensing electrode that produces ions. The REFERENCE electrode provides voltage stability for the sensing electrode, and the electrodes (sensing and reference) are constructed of materials specific to the target gas. This specificity creates the ion flow current central to the sensor’s detection method. The HVS4000 integral electronics provides temperature compensation, and the amount of ions produced by the target gas molecules striking the sensing electrode, is proportional to gas concentrations. The HVS4000’s microprocessor then produces a linear 4-20mA output signal. TS4000 Electronics Counter Electrode Sensing Electrode Gaseous Diffusion Barrier Electrolyte Reservoir Gas Permeable Membrane O-Ring Seal 4-20mA/Modbus Gas Enters Through Permeable Membrane Detection Method

Available Gases Ammonia 0-50, ppm Carbon Monoxide 0-100, ppm Chlorine 0-10 ppm, 0-20 ppm Chlorine Dioxide 0-3 ppm Ozone 0-1 ppm Oxygen0-25% by Volume Sulfur Dioxide 0-20 ppm

Key Features & Benefits Microprocessor-Based Electronics: Monitors fault conditions, processes input signals from the electrochemical cell, and provides outputs in the form of display codes and analog / digital signals One Person Adjustment-Free Calibration: Using a magnet to initiate the calibration sequence, apply the gas, and wait for the display to indicate that the unit has completed the calibration. No user adjustments are required. Three Digit, Seven Segment LED: Indicates gas presence, operational modes, fault codes and calibration cues Two Discrete LED Indicators: Indicates alarm and warning conditions Three 8A rated Relays: Warning, Alarm and Fault Remote Mounting of Interface Module: Provides application flexibility 4-20 mA Analog Output: Transmits fault, calibration, and gas concentration levels to a remote display, computer, or other device such as an alarm, dispensing device, or master controller Dual Redundant MODBUS RS-485 User Interface: Provides the ability to operate the TS4000 remotely, using 2 redundant channels. This interface allows the user to remotely change the alarm and warning relay settings, clear selected faults, issue calibration requests, enable gas check, issue end / abort commands, clear error counters, change baud rates, and change formats for serial communication lines

Local & Remote Configurations - - B l u e TS4000 Base Unit TS4000 Interface Module Junction Box X P I n t e r c o n n e c t i o n C o n d u i t Remote Configuration Up to 2,000 ft. Local Configuration

Electrical Specifications

Environmental Specifications

Mounting Dimensions D W MC H Dia – 1.75 W Width MC Mounting Centers D Depth H Height Dia Diameter All dimensions are in inches

Simple Calibration Apply and hold the magnet over the HVS logo on the cover of the Base Unit. Wait until AC appears in the display window. Remove the magnet to select AC. The unit is now in Calibration Mode. The display flashes the Remaining Sensor Life. The user can choose to reset or not to reset the sensor life at this point. The Remaining Sensor Life flashes while the unit is being set to zero. Once the unit has been set to zero gAS appears in the display window Apply the calibration gas concentration to the sensor (50% FS of the required range of detected gas). The display changes from gAS (apply gas) to CP (Calibration in Progress) indicating that the sensor is responding to the calibration gas. While the unit is reading the gas concentration, the menu is disabled After three to five minutes, the display changes from CP to CC indicating that the calibration is complete Remove the gas and wait for the unit to return to normal operation. The display may indicate a few percent FS and will eventually drop to 0. If a unit time out occurs the user receives a calibration fault The HVS4000 is now calibrated and the new sensor SPAN values (or calibration constants) are stored in the non-volatile memory (EEPROM)

Changing a Sensor Each spare sensor is shipped in a plastic bottle. DO NOT remove the sensor until you are ready to apply power to the system. To ensure proper sensor response, each HVS4000 must be calibrated in the field upon initial installation If the new sensor is in a plastic storage container, then remove the lid ring and uncap the jar. Remove the sensor from the container Save the storage container for later use.

Changing a Sensor Note: Certain types of sensors are shipped with a shorting wire across two (2) pins. This wire must be removed prior to installing in the HVS4000. Ammonia (NH 3 ) sensors are shipped attached to a small circuit board with a battery. Remove the battery board prior to installing in the HVS4000. Save both the shorting wire and/or battery board for later use. Shorting Wire Battery Board

Accessories - Calibration Kit 500 sccm flow rate regulator for: –NH 3 –SO 2 –CO 1000 sccm flow rate regulator for: –Cl 2 –ClO 2 –O 3 Purge Gas Cylinders

Accessories - Splash Guards Splash Guard for Cl 2, ClO 2 and O 3 gases. More holes are needed for gas to reach the sensor Splash Guard used for all other gases

Accessories - Flow Block Flow Block shown with optional ST/ST fittings can be used on HVS4000 and HVS400 Series shown

Accessories - Cal Plug & Cup Calibration Plug (used when no splash guard attached) P/N Calibration Cup (used with units equipped with splash guard)

Configurations HVS4000 Local w/ No Relays & Communications HVS4000 Local w/ Relays & Communications HVS4000 Remote w/Customer Provided J-Box HVS4000 Remote w/ P/N J-Box HVS4000 Remote w/ P/N J-Box