Nikon Eclipse TE2000 Spinning Disc. inverted perfect focus microscope optimized for live cell imaging and time lapse movies Equipped for DIC, Ludl Piezo.

Slides:



Advertisements
Similar presentations
How to use the NEC projector Its easy! Really!. How to use the NEC projector IMPORTANT-make sure you have reserved the equipment (projector and/or laptop).
Advertisements

Data Projector Setting Up/Connecting Laptop & Data Projector.
High Speed, Full-Spectrum Spinning-disk Confocal.
Presenting A Power Point Program. Computer Checklist Computer Checklist Power Cord Mouse Computer.
Using the Avanti Tabletop Centrifuge As demonstrated by Joe Toney.
How to carry out experiments using MPMS March 2012 Takeshi NAKAGAWA.
University of Manitoba A How to Guide for Theatre B & C.
College of Education 103 Conference Room The Multimedia Podium.
1 Check all equipment is included before returning. If you have an accident or the equipment is damaged or you need support please contact Blaize
Smart Cart Multimedia Lectern Technology Resource Center.
Elementary Science Cart. 8 Laptops 1 Projector Computer to Projector Connect to laptop.
BACKEND MULTIMEDIA ROOM Home User Guide Computer Projector DVD/ VCR Remote Mouse Save tutorial on desktop to watch full screen. Click boxes to jump into.
By: Kaitlyn Schroeder; ETEAMS 2014 Modified from Trimpe
Stem Cell Instrumentation Foundry (SCIF) Orientation: Microscopy Venu Polineni Research Associate, SCIF University of California, Merced Phone: (559)
The Handling Camera1 Trainer Training The Handling Camera.
July 2008 Jonathan Sommer.  Has two modes to view samples Optical mode (white light) and Fluorescence mode  Depending on your sample either mode maybe.
Mercury bulb Camera Microscope on/off Stage up/down Focus wheel Objective controls Fluorescence filter controls Mono/RGB.
Clean Air Box Usage & Care CABs RAMs CO Monitors.
This is a guide for using the Zeiss LSM510 Confocal Microscope. Do not attempt to use this microscope without the proper training. If you have any queries.
The UTE Speed-O-Calibration Unit (SOC) is used to calibrate the locomotive speedometer. This presentation is an operations outline for Ultra-Tech model.
1 Colorado Space Grant Consortium Gateway To Space ASEN / ASTR 2500 Class #08 Gateway To Space ASEN / ASTR 2500 Class #08.
1 Student Hands On Training I (2007) Timing Circuit & Camera Integration Timing Circuit & Camera Integration.
A. Imaging sample: 1. Place sample on stage 2. Make sure sample does not interfere with C mirrors 3. Start “Sonic MyDVD” on both laser heating computers.
+ USING THE POWER CHARGER AND BATTERY MINI-DV CAMCORDER Connect the charger to the power cord Attach the battery to the charger Plug it in and watch for.
Version 4 Multimedia Podium User Guide Version 4 Multimedia Podium User Guide Revision Date: September 2014.
+ USING THE POWER CHARGER AND BATTERY MINI-DV CAMCORDER Connect the charger to the power cord Attach the battery to the charger Plug it in and watch for.
AUDIO VISUAL TRAINING Center for Academic Success.
Our Microscope 6 th Grade Science Certain materials are included under the fair use exemption of the U.S. Copyright Law and have been prepared according.
The Mavica for the Maverick: A How-to Guide Operating instructions for the Sony Mavica CD350 Digital Camera An Easy-to-Follow Guide to Everything You Need.
Revised: January 2010 FPAC Multimedia Podium / Room User Guide FPAC Multimedia Podium / Room User Guide.
FNI 2B OM 1 Optical Microscopes. FNI 2B OM2 Outline Justification History Components of the Optical Microscope Theory of operation  Basic Microscope.
DIC Differential Interference Contrast Kim Peifley 08/14/15.
How to Use Digital Blue QX5 (See separate powerpoint on the use of the software)
Building D Multimedia Podium User Guide Building D Multimedia Podium User Guide Date: January 2010.
Near IR Imaging on the UV510 Kim Peifley 07/22/14.
Set Up for Live Streaming Video This presentation will walk you through the set up and delivery for streaming video of a live event over the internet.
PERKIN-ELMER MODEL 200 UV-VIS SPECTROPHOTOMETER OPERATING INSTRUCTIONS.
Mercury bulb Camera Microscope on/off Stage up/down Focus wheel Objective controls Fluorescence filter controls Mono/RGB.
BIO 211 Human Anatomy and Physiology I
Microscope Control Configuration This section of the QED manual will describe how to configure you Configure and Control your automated microscope. Mac.
Nikon Spinning Disk Imaging & Training Support. Find your cells with DIC in Live Preview 1.The green DIA Lamp, used for DIC, should be on. 2. Condenser.
Taking Better Confocal Images Kim Peifley 2/09/15.
BioRad Sputter Coater  Instructions for gold coating a SEM sample.  NO, it’s not your eyes. This image is out of focus.
LSM780 Live Cell Turn On/Turn Off Instructions Kim Peifley 07/13/15.
The Northwest Microscope. The Ocular Lens Ocular Magnification = ___ X.
 Remember, you have to have all of your forms signed and turned in before you can check out a camera!
Updated 710 Turn On/Off procedure Kim Peifley 12/18/14.
How to Properly Use a Microscope. Parts of Microscope eye piece tube revolving nosepiece low power objective medium power objective high power objective.
Microscope Basics.
V-Tel Advantages Presented by Mary Kay Black and Christy Randall With Guest Speaker – Rita Hitchcock.
Turn in homework: “How the cell works” Paste this paper into your notebook on the left side. Setup the right side as follows:Number Name of structure Function.
AUDIO VISUAL TRAINING Wilkins Theatre-Black Box. BLACK BOX EQUIPMENT IN CLASS Black Box LCD Projector/Built In Screen Laptop Connection (VGA Cord) Control.
DS200 PROCEDURES SPEAKER TOUCH SCREEN DISPLAY
MICROSCOPES: EVERYTHING YOU NEED TO KNOW!. “MICROSCOPE” Micro means tiny, and “ Scope ” means view.
Life Science Mrs. Morgan. 2 One of the most important tools used to study living things. “Micro” means very small “Scope” means to look at.
Our Microscope 6 th Grade Science Certain materials are included under the fair use exemption of the U.S. Copyright Law and have been prepared according.
Microscopes Kinds Light –Image illuminated from bottom in most, top in a few. –Magnifies from times. –Can see individual cells and a few organelles.
The Microscope Micro – small Scope – to look at
Getting to Know the imaging Equipment
Getting to Know the imaging Equipment
Meeting In A Box Set Up Guide
Parts of the Microscope and Their Function
Light Microscope: – light passes through one or more lenses to produce an enlarged image of a specimen compound light microscope – light microscope that.
Light Microscope: – light passes through one or more lenses to produce an enlarged image of a specimen compound light microscope – light microscope that.
Microscope Notes BRING IN 10 items from home
Parts of the Microscope and Their Function
Microscope Notes Turn in homework: “How the cell works”
Harvard Medical School Neurobiology Imaging Facility
Harvard Medical School Neurobiology Imaging Facility
Light Microscope: – light passes through one or more lenses to produce an enlarged image of a specimen compound light microscope – light microscope that.
Presentation transcript:

Nikon Eclipse TE2000 Spinning Disc

inverted perfect focus microscope optimized for live cell imaging and time lapse movies Equipped for DIC, Ludl Piezo Z-stage for 3-D imaging temperature controlled chamber widefield cubes for GFP, YFP, TxRed, CFP, DAPI Cascade 512B and Coolsnap HQ CCD detectors offer simultaneous data acquisition 488 and 568 nm Ar lasers Visitech QLC100 confocal head.

Turning on and Setting up the Microscope 1.Turn on Power to the AOTF Controller 2.Turn on Power to the Laser Power Supply *DO NOT TOUCH THE KEY! 3.Turn on Power to the Laser Supply Remote Controller: a: Flip switch to “operate” b: Turn key past “on” and let go c: Laser should go to “100” or more d: Let warm up 30 min before using

e: Flip switch to “standby” if not using the lasers for awhile or when you leave f: Laser Power can be displayed in mW or in AMPs depending on which position the toggle is flipped g: Laser Power can be changed by toggling the switch up (increasing power) or down (decreasing power)

4. Open AOTF Controller Software - Adjust % Power in software if needed - Usually start with 100% - Must do this before doing next steps 5.Turn on Black APS Power Supply 6. Turn on Temperature Contoller: - Turn dial to “set” option and use dial to set control temperature. - Keep at 39 o C so that the center of your dish is 37 o C. - Turn dial to T1 to see actual temp. 7.Turn on Ludl Shutter Control: - Widefield/DIC is Halogen bulb - Fluorescence is mercury bulb

8. Turn on Xcite Mercury Lamp 9. Turn on Halogen Lamp *This lamp is under the air table. 10. Turn on confocal head key *Both lights should be on. 11. Turn on the Perfect Focus Box: - Push green button to “engage”. - If green light flashes, it is not working properly. - Be sure to “disengage” PF by pushing green button before removing your dish of cells from the stage.

12. Turn on Power to the Microscope: - Back left bottom of scope where red tape is located. 13. Turn on Camera(s) before opening IPLAB: - Cascade is for Confocal - CoolSnap is for Widefield/DIC/FL 14. Open up IPLAB Software: *You should always get an error message. It is ok. 15. Tell software which camera you’re using: - Select “Camera” option - Select “Select Camera” - Click “OK” by camera

16. Setup camera settings: - Select “Camera” option - Select “Get Camera Info” - Can adjust settings - Gain Index = 3 - Speed Table = 1 - Mult Gain = Adjust Magnification Dial: - Located on bottom right of scope. - “1x” means no additional magnification. 18. Plug in heater controller to stage dish: - Plug temperature probe into small hole on side of setup. - Attach blue clips to each side. - Use the gold ring insert for most MatTek dishes. *Other ring inserts available.

Turn off Microscope 1.Turn lasers to zero in AOTF Controller Software. 2.Turn off Power to Perfect Focus box. 3.Flip lasers to “standby”. 4.Turn laser key to “off”. *Listen for fan to get quiet before turning anything else off. 5. Remove sample and clean-up. Liquid waste is nearby and should be emptied if needed. 6. Leave the stage dish in place. 7. Turn off the rest of the equipment once hear fan power decrease. *IPLAB must be closed before camera is turned off. 8.Put cover on microscope. 9.Sign log sheet.