1 Methods of Experimental Particle Physics Alexei Safonov Lecture #12.

Slides:



Advertisements
Similar presentations
Bruce Kennedy, RAL PPD Particle Physics 2 Bruce Kennedy RAL PPD.
Advertisements

Experimental Particle Physics
General Characteristics of Gas Detectors
Geiger-Muller detector and Ionization chamber
HEP Experiments Detectors and their Technologies Sascha Marc Schmeling CERN.
Experimental Particle Physics PHYS6011 Joel Goldstein, RAL 1.Introduction & Accelerators 2.Particle Interactions and Detectors (1/2) 3.Collider Experiments.
Radiation Detectors / Particle Detectors
MALVINO Electronic PRINCIPLES SIXTH EDITION.
Department of Aeronautics and Astronautics NCKU Nano and MEMS Technology LAB. 1 Chapter IV June 14, 2015June 14, 2015June 14, 2015 P-n Junction.
Introduction to Hadronic Final State Reconstruction in Collider Experiments Introduction to Hadronic Final State Reconstruction in Collider Experiments.
Lesson 17 Detectors. Introduction When radiation interacts with matter, result is the production of energetic electrons. (Neutrons lead to secondary processes.
Particle Detection and Identification
1 Detectors RIT Course Number Lecture Single Element Detectors.
Department of Information Engineering256 Semiconductor Conduction is possible only if the electrons are free to move –But electrons are bound to their.
Main detector types Multi Pixel Photon Counter (MPPC) and Charge Coupled Devices (CCDs) How does it work? 1. Photon hits a pixel producing electron hole.
Main detector types Scintillation Detector Spectrum.
Unit-II Physics of Semiconductor Devices. Formation of PN Junction and working of PN junction. Energy Diagram of PN Diode, I-V Characteristics of PN Junction,
Chapter 29 Solid State Electronics
Radiation Detection and Measurement II IRAD 2731.
Detectors The energy loss of particles in matter can be used detect and identify those particles. There are different types of “detectors”: - Gas-filled.
Lecture 25: Semiconductors
Silicon Detectors and DAQ principles for a physics experiment.
Tanja Horn, CUA PHYS 575/675 Modern Detectors Phys 575/675, Spring 2012 Tools of High Energy and Nuclear Physics Detection of Individual Elementary Particles.
Recirculation Concept - Cyclotron Radio frequency alternating voltage Hollow metal drift tubes time t =0 time t =½ RF period D-shaped.
Why silicon detectors? Main characteristics of silicon detectors: Small band gap (E g = 1.12 V)  good resolution in the deposited energy  3.6 eV of deposited.
1 Semiconductor Detectors  It may be that when this class is taught 10 years on, we may only study semiconductor detectors  In general, silicon provides.
Techniques for determination of deep level trap parameters in irradiated silicon detectors AUTHOR: Irena Dolenc ADVISOR: prof. dr. Vladimir Cindro.
Tools for Nuclear & Particle Physics Experimental Background.
Semi-conductor Detectors HEP and Accelerators Geoffrey Taylor ARC Centre for Particle Physics at the Terascale (CoEPP) The University of Melbourne.
NEEP 541 Ionization in Semiconductors - II Fall 2002 Jake Blanchard.
Introduction Trapped Plasma Avalanche Triggered Transit mode Prager
Eric Prebys, FNAL. USPAS, Knoxville, TN, January 20-31, 2014 Lecture 20 - Cooling 2 Anti-protons are created by hitting a target with an energetic proton.
ENE 311 Lecture 9.
Photodetection EDIT Internal photoelectric effect in Si Band gap (T=300K) = 1.12 eV (~1100 nm) More than 1 photoelectron can be created by light in silicon.
SILICON DETECTORS PART I Characteristics on semiconductors.
1 Methods of Experimental Particle Physics Alexei Safonov Lecture #11.
Calorimeters  A calorimeter is a detector that measures “energy” of the particles that pass through. Ideally it stops all particles of interest.  Usually.
Experimental Particle Physics PHYS6011 Joel Goldstein, RAL 1.Introduction & Accelerators 2.Particle Interactions and Detectors (2/2) 3.Collider Experiments.
Seeing the Subatomic Stephen Miller Saturday Morning Physics October 11, 2003.
Silicon Detectors and DAQ principles for a physics experiment Masterclass 2011, 7-11 February 2011 Alessandro Scordo.
April 22nd, 2004Nigel Lockyer / Young-Kee Kim1 Drift Chambers AMY experiment at e + e - TRISTAN collider CDF experiment B = 3 T B = 1.4 T.
Introduction to CERN Activities
1 Methods of Experimental Particle Physics Alexei Safonov Lecture #15.
The Compact Muon Solenoid. What does CMS do? The Compact Muon Solenoid is a general purpose particle detector installed at point 5 of the Large Hadron.
How do we see particles? Detectors and data acquisition for physics experiments Alessandro Scordo International Masterclass /02/2013 LNF, Frascati.
Summer Student Session, 11/08/2015 Sofia Ferreira Teixeira Summer Student at ATLAS-PH-ADE-MU COMSOL simulation of the Micromegas Detector.
Particle Detectors for Colliders Semiconductor Tracking Detectors Robert S. Orr University of Toronto.
1 Methods of Experimental Particle Physics Alexei Safonov Lecture #9.
CMS History Compact Muon Solinoid Compact Relative to ATLAS, which is ~1.5x the diameter of CMS and 2x as long (but ATLAS is half the weight of CMS!).
TeV muons: from data handling to new physics phenomena Vladimir Palichik JINR, Dubna NEC’2009 Varna, September 07-14, 2009.
Copyright © The McGraw-Hill Companies, Inc. Permission required for reproduction or display. MALVINO & BATES SEVENTH EDITION Electronic PRINCIPLES.
Small, fast, low-pressure gas detector E. Norbeck, J. E. Olson, and Y. Onel University of Iowa For DNP04 at Chicago October 2004.
Introduction to Hadronic Final State Reconstruction in Collider Experiments Introduction to Hadronic Final State Reconstruction in Collider Experiments.
INTRODUCTION TO SEMICONDUCTORS
Making Tracks at DØ Satish Desai – Fermilab. Making Tracks at D-Zero 2 What Does a Tracker Do? ● It finds tracks (well, duh!) ● Particle ID (e/ separation,
BSIC SEMICOCONDUCTOR CONCEPTS INTRINSIC SILICON:
Parul Institute of Engineering & Technology
Methods of Experimental Particle Physics
The Compact Muon Solenoid Detector
How a Particle Detector works
Experimental Particle Physics
When this happens... We see this... 12/6/2018 Steve Wotton.
Semiconductor Detectors
Experimental Particle Physics
PHYS 3446 – Lecture #16 Monday ,April 2, 2012 Dr. Brandt
BSIC SEMICOCONDUCTOR CONCEPTS INTRINSIC SILICON:
PHYS 3446 – Lecture #17 Particle Detection Particle Accelerators
PHYS 3446 – Lecture #17 Wednesday ,April 4, 2012 Dr. Brandt
PN-JUNCTION.
Presentation transcript:

1 Methods of Experimental Particle Physics Alexei Safonov Lecture #12

ISAAC SARVER On transition radiation 2

3 Transition Radiation Take the electric field solutions for a charged particle in vacuum and in medium. Subtract the differences and you have the transition radiation. To work, the foil must be sufficiently thick for the material to react. Jackson says the thickness is on the order of 10 microns. As we have transition radiation from both surfaces, a well selected foil thickness and separation distance can result in coherence effects that improve detection. Jackson 13.7, Wikipedia.org “Transition Radiation”

Today and Next Time Detectors and Technologies used in modern HEP experiments Tracking devices: Gaseous detectors Silicon detectors Muon detectors Gaseous detectors again Calorimeters: Electromagnetic and Hadron Calorimeters Compensation Trigger, DAQ etc 4

Gaseous Detectors Gaseous tracking devices Measure positions where charged particle left ionization to build a track Guide electrons and ions to electrodes using electric field to collect charge Typically use charge multiplication E.g. an ionization electron, if put in strong electric field, will accelerate and ionize media on its path liberating more electrons and creating “avalanches” Advantages: They can be very “light” (gas is light!) You only want to see where the particle went, you don’t want it to seriously interact with your tracker Good precision Can identify particle types by measuring how much they ionize the media at given momentum 5

Drift Chambers Implementations vary, but same principle: Guide electrons and ions from ionization to detector sensitive elements Measure charge, time difference between electron and ion arrival times Often stick a lot of sense wires, layers etc. 6 Figure out where the particle went in terms of its position Use whatever you can: Measure when the signal arrived (time gives you how far it traveled)

What Matters Want charges to be large and come fast Pick gas mixtures with low ionization energy Easy to ionize 7 And with large drift velocities To get signal fast And with small transverse diffusion To better measure position

What Else? And you want large E field as v ~E: But not too large or you will ionize gas by the electric field - a lot of noise (or turn it into a spark chamber ) Many of these desires contradict each other Building these is a complex optimization problem Resolution is usually limited by ~ 100 microns 8

Limitations Technically difficult Small mistakes in wire positions can cause large field distortions and make the whole chamber not working “Slow” signals as they have to drift over not negligible distances You still want to get sufficient multiplication to make it detectable This is bad if you have a lot of particles and collisions happen often You don’t want showers to start overlapping, do you? Tevatron: 396 ns between crossings, LHC: 25 ns Don’t take rate too well Charge accumulation (ions) at very high rate, can cause gain losses, field distortions etc. 9

Ionization in Semiconductor As charged particle traverses a semiconductor, you want to create an electron-hole pair Need to give the electron enough energy to cross from valence into the conduction bend In reality need a little more energy as you also need to spend some on creating a phonon to preserve momentum conservation Would want a small bandgap as you want to create many electron-hole pairs without putting too much material Roughly 4 eV per pair in a silicon diode at room temperature Temperature dependent Alpha, beta – determined by the material 10

Setting Things Up A p-n junction (a diode essentially) Doping to increase the number of charge carriers The interface region is depleted of charge carriers Forward bias: Push electrons to the right, holes to the left, depleted region small, E can’t hold electrons from moving to the left, holes to the right Equilibrium Zero bias (no voltage) 11

Building a Detector Apply reverse bias: The depleted region broadened That’s where you want ionization to happen No current except thermal Thermal excitations grow fast with temperature and reduction in bandgap Want it cold or have larger bandgap to avoid noise current A typical MIP leaves tens of keVs in a 300  m of silicon Tens of thousands of electron- hole pairs Move in electric field creating current Enough to detect with low noise electronics & low noise current Equilibrium Zero bias (no voltage) 12

Why Silicon Detectors? Advantages: In special conditions can get a few micron precision, microns would be more typical Disadvantages: “Heavy”: Particles interact more than you want them Complex infrastructure: Cooling to keep noise low, Tilting to offset drift of carriers in magnetic field Detectors deteriorate with the radiation doze Fast signals ~ 10’s of ns (small distance to travel) High spatial resolution Can make small strips or pixels of silicon (tens to 100 microns) 13

LHC Trackers From top left clockwise: CMS Tracker layout: pixel & strip detectors CMS Strip Detector ATLAS pixel detector 14

Silicon Versus Gas Cost versus performance is important: Silicon detectors are incredibly expensive Gaseous detectors are much less expensive But don’t take high rate well One area where it can still work is muon chambers Muons get through a lot of material without much energy loss Only ionization, but it’s heavy enough to make those small, it doesn’t radiate and weak interactions don’t happen often Muon chambers are usually positioned on the far periphery of the detector beyond a lot of material Not much gets there except muons, so rates are pretty low making them a good use case for gaseous detectors 15

Strip Cathode Chambers CMS endcap muon system uses CSCs Small chambers so easier to operate Position resolution of ~100 microns Using center of gravity of the avalanche 16

Drift Tubes A single unit is a wire in enclosure Another way to avoid difficulties with one wire goes wrong, the whole chamber is gone Used in the central part of the CMS muon system Good choice for the same reasons as CSC Rates are low enough, spatial precision is sufficiently good 17

CMS DT Muon System 18

Put Everything Together Have we missed anything? Calorimeters! – next time (and more) 19