Andrew Rouff and Ben Berger

Slides:



Advertisements
Similar presentations
Mass Spectrometry Chem 3500 Mass Spectrometry Y. Zhao Lecture 2 A Glimpse of Mass Spectrometry Began from 1920s: Aston, Dempster, Thompson MS is often.
Advertisements

FC-MS from Teledyne Isco CombiFlash ® a Name You Can Rely On.
Mass Spectrometry Mass spectrometry involves ionizing a compound, separating the ions that result on the basis of mass to charge ratio (m/z) and obtaining.
What is this ROCK??? Any guesses? Ok clue!!! It is not from Earth Yesss!! MARS!! Is there any way, we can figure out what its compounds are? What is it.
Module 2: Analytical methods and separation techniques.
Mass Spectroscopy Skyline IB Chemistry HL Mass Spectroscopy.
Mass Spectrometry Dr. Karin Habermehl-Cwirzen. Mass Spectrometry measures individual molecules Definition Mass spectrometry is a method in which a sample.
12-1 Molecular Mass Spectroscopy Molecular structure Composition of mixtures Molecular mass spectra Ion Source Mass Spectrometers Applications.
Mass Spectrometry Inlet system Ion Source Mass Analyzer Ion Detector.
Atomic Mass is not a whole number
Mass Spectroscopy Mass Spectrometry ä Most useful tool for molecular structure determination if you can get it into gas phase ä Molecular weight of.
Chem. 133 – 4/28 Lecture. Announcements Lab Report 2.3 due Today Pass back graded materials (lab reports 2.2, Q5, and AP3.1) Today’s Lecture Mass Spectrometry.
Chapter 20 Molecular Mass Spectrometry. Introduction... Mass spectroscopy is perhaps one of the most widely applicable of all the analytical tools available.
Mass Analyzers Double Focusing Magnetic Sector Quadrupole Mass Filter Quadrupole Ion Trap Linear Time-of-Flight (TOF) Reflectron TOF Fourier Transform.
Mass Analyzers Double Focusing Magnetic Sector Quadrupole Mass Filter Quadrupole Ion Trap Linear Time-of-Flight (TOF) Reflectron TOF Fourier Transform.
LC-MS Based Metabolomics. Analysing the METABOLOME 1.Metabolite Extraction 2.Metabolite detection (with or without separation) 3.Data analysis.
Atomic Mass Spectrometry
PROTEIN IDENTIFICATION BY MASS SPECTROMETRY. OBJECTIVES To become familiar with matrix assisted laser desorption ionization-time of flight mass spectrometry.
Atomic Mass Spectrometry
Mass Spectrometry.
Molecular Mass Spectrometry
Mass Spectroscopy Quantitative Chemical Analysis Harris, 6th Edition
INSTRUMENTAL ANALYSIS CHEM 4811
6. Mass Spectrometry Adv. Inst. Techs. How does it work? a very small amount of sample is bombarded by a beam of high energy (usually electron beam) produces.
4. Mass Spectrometry Objectives:
Analytical Chemistry Option A Part 1: Mass Spectrometry & H-NMR.
Chapter 8 – Mass Spectrometry. Mass Spectrometry The mass spectrometer can be used for: – Quantitative analysis – as a sophisticated and very sensitive.
PC4250 Secondary Ion Mass Spectrometry (SIMS). What is SIMS? SIMS is a surface analysis technique used to characterize the surface and sub-surface region.
Molecular mass spectrometry Chapter 20 The study of “molecular ions” M + e -  M e -
Mass Spectrometry Mass spectrometry involves ionizing a compound, separating the ions that result on the basis of mass to charge ratio (m/z) and obtaining.
Isotopes Atoms with the same number of protons, but different numbers of neutrons. Atoms of the same element (same atomic number) with different mass numbers.
(a) Structure of Mass Spectrometer
Based on ionization of gas phase molecule followed by analysis of the masses of the ions produced. The Mass Spectrum: Graph of ion intensity versus mass-to-charge.
MASS SPECTROMETRY. CONTENTS Prior knowledge Background information The basic parts of a mass spectrometer The four stages of obtaining a spectrum How.
MS Intro. MS requires gas-phase ions, why? MS uses magnetic and electric fields to control the path of a compound based on mass to charge ratio (m/z)
Chemistry Topic: Atomic theory Subtopic : Mass Spectrometer.
INF380 - Proteomics-51 INF380 – Proteomics Chapter 5 – Fundamentals of Mass Spectrometry Mass spectrometry (MS) is used for measuring the mass-to-charge.
Ionization energy?. Ionization energy? EI Ionization??
Combining and Choosing Analytical Techniques Chapter 8.
Starter: Spec links 1.06–1.10. Green pens out! Spec links 1.06–1.10.
Separates charged atoms or molecules according to their mass-to-charge ratio Mass Spectrometry Frequently.
CONTENTS Prior knowledge Background information The basic parts of a mass spectrometer The four stages of obtaining a spectrum How different ions are deflected.
Mass Spectrometry Relative atomic masses and the mass of individual isotopes can be determined using a mass spectrometer. The principle behind mass spectrometry.
Chem. 133 – 4/26 Lecture. Announcements Return graded quiz and additional problem Lab – Lab report deadlines (2:4 – Thursday) Today’s Lecture – Mass Spectrometry.
1 Chapter 12 Mass Spectrometry ( 質譜 ) Organic Chemistry, 7 th Edition L. G. Wade, Jr. 藥學系 藥物分析科 許秀蘊 教授
2014 생화학 실험 (1) 6주차 실험조교 : 류 지 연 Yonsei Proteome Research Center 산학협동관 421호
Chapter 29 Mass Spectrometry. 29 A Principles of mass spectrometry In the mass spectrometer, analyte molecules are converted to ions by applying energy.
CHROMATOGRAPHY Chromatography is used to separate and analyse small amounts of mixtures Methods involve a stationary phase and a mobile phase. There are.
What is Mass Spectrometry? Mass spectrometry could be considered as an analytical technique that involves the study in the gas phase of ionized molecules.
Chapter 11 Structure Determination: Mass Spectrometry, Infrared Spectroscopy, and Ultraviolet Spectroscopy.
Mass Spectroscopy “You can’t make an omelette without breaking eggs” The Joker.
Yonsei Proteome Research Center Peptide Mass Finger-Printing Part II. MALDI-TOF 2013 생화학 실험 (1) 6 주차 자료 임종선 조교 내선 6625.
2008 SPECIFICATIONS HPLC and GAS CHROMATOGRAPHY A guide for A level students KNOCKHARDY PUBLISHING.
Mass Spectrometry makes it possible to measure protein/peptide masses (actually mass/charge ratio) with great accuracy Major uses Protein and peptide identification.
A guide for A level students KNOCKHARDY PUBLISHING
Components of Mass Spectrometer
Chem. 133 – 4/13 Lecture.
Mass Spectrometry Mass spectrometry involves ionizing a compound, separating the ions that result on the basis of mass to charge ratio (m/z) and obtaining.
Mass Spectrometry Obaid M. Shaikh.
Starter Complete the quiz and hand in..
Chapter 11 – Analytical Chemistry section
KNOCKHARDY PUBLISHING
Mass Spectroscopy. Mass Spectroscopy Mass Spectrometry Most useful tool for molecular structure determination if you can get it into gas phase Molecular.
Mass Spectronomer.
Mass Spectrometry THE MAIN USE OF MS IN ORG CHEM IS:
KNOCKHARDY PUBLISHING
M.Prasad Naidu MSc Medical Biochemistry, Ph.D,.
A guide for A level students KNOCKHARDY PUBLISHING
CHROMATOGRAPHY.
Presentation transcript:

Andrew Rouff and Ben Berger Mass Spectrometry Andrew Rouff and Ben Berger

A Brief History 1897- JJ Thomson recorded first mass-to-charge ratio of electrons 1951- W. Pauli and H. Steinwedel developed first quadrupole mass spectrometer 1959- K. Biemann applies electron ionisation mass spectrometry 1974- B. Mamyrin contributes to time-of-flight mass spectrometry 1988- K. Tanaka develops MALDI, receives Nobel prize in Chemistry

Parts of a Mass Spectrometer A sample injector An ionisation chamber A mass analyser An ion detector A data handling facility

Mass Spec. For Dummies Cations are produced Cations are accelerated in instrument Magnetic field is introduced Amount of “bend” is measured The heavier an ion is, the less it will “bend” Mass/charge ratio is then calculated

http://www. astarmathsandphysics http://www.astarmathsandphysics.com/ib_physics_notes/quantum_and_nuclear_physics/ib_physics_notes_the_mass_spectrometer_html_1107d8b8.gif

m/z=B2r2/(2Vacc) The Big Equation z= charge of ion m= ion mass B= magnetic field r= radius Vacc=potential difference in acceleration region

Mass Resolution =m/Δm, m= mass, Δm= change in two neighboring masses The higher to resolution, the better more accurate the readings are First definition- each adjacent peak contributes 5% of the valley between them Second definition- mass/width at half point A resolution of 2000 for the second definition is equal to a resolution of 1000 for the first definition

Molecular Mass Accuracy The difference between the measured and calculated masses for an ion, displayed as a percent. eg. 1000±.01% Peak overlap is main reason for bad accuracy

Charging the Ion Charging is important: No charge = no lorenz force There are many ways to do this, including Electron ionisation (EI), Field Ionisation (FI), and Fast Atom Bombardment (FAB), Matrix Assisted Laser Desorption Ionisation (MALDI), and Electrospray Ionisation (ESI)

Electron Ionisation (EI) Electron energy is generated by a heated filament, set to around 70eV Gaseous molecule is sent into the energy, causes molecule to lose an electron Cation is generated from this process Ions are usually unstable under bombardment

Field Ionisation (FI) Molecules are introduced in vapor state High intense electric field is generated, which interacts with molecules Outer shell electrons are lost, forming cations

Fast Atom Bombardment (FAB) Argon and/or Xenon are thrown into sample surface at a 8-10 keV Sample is placed in a glycerol matrix and bombared with Ar or Xe Disadvantage: requires high concentration of matrix Advantage: simple and easy to interpret

Matrix Assisted Laser Desorption Ionisation (MALDI) A useful form of ionisation, more effective than FAB Laser energy is absorbed by chromophoric matrix, which converts molecules to gas phase Ionisation occurs between excited matrix molecules and sample molecules IR laser and UV laser are two most common lasers to use for MALDI, because they can both excite most molecules in the matrix

Electrospray Ionisation (ESI) Sample is put into tube and shot out in a “spray” Samples are hit with 1-5kV when it emerges from capillary tube This creates charged spray like particles Solvent evaporates before particles go into chamber containing mass analyser Cations are determined by polarity of voltage applied to capillary Can create multiply charged ions, which allows large mass molecules to be detected with low m/z ratio Higher the mass, higher the resolution

Single Focusing Mass Spectrometer Only one detector is present All ions have a constant radius This is done by changing B in electromagnet analyser, and V in electrostatic analyser http://figures.boundless.com/511edc7ce4b0c14bf4650299/full/mass-20spectrometer.png

Double Focusing Mass Spectrometer Both electromagnetic and electrostatic analysers are used Higher resolution than a single focusing mass spectrometer http://www.chm.bris.ac.uk/ms/images/sector-schematic.gif

Quadrupole Mass Filter Consists of four cylindrical rods Two have a negative direct current voltage and alternating radio frequency voltage Two have positive direct current voltage and also alternating radio frequency (exact opposite alternating as first two rods) The purpose is to disallow any ions traveling in a wrong trajectory to be filtered Only ions with correct radius is kept and measured

http://www.waters.com/webassets/cms/category/media/other_images/ms_primer_p2_fig1.jpg

Ion Cyclotron Resonance Mass Spectrometry (ICR-MS) Trapped Ions in magnetic and electric field detected when frequency matches cyclotron frequency Ions travel in a circle and sit in machine for hours When you decrease the strength of the magnetic field, the heavier particles will stop traveling in circular paths and will “crash”

Another 2 Big Equations F=zvB=mv^2/r | V ω=v/r=zB/m Lorenz force due to moving charge through a perpendicular magnetic field Frequency of rotation

Time of Flight Mass Spectrometer Bigger ions move slower than smaller ions Low resolution, but fast speed, high transmission, and unlimited mass range Uses how long it takes ion to get through instrument to measure m/z u=√2zVacc/m

Tandem Mass Spectrometry Two mass spectrometers are used one after the other The first mass spec. fragments the ions like normal One ion is chosen and sent into a collision course with the fragments of the other ions The second mass spec. analyses this ion and these fragments Allows several generations of ions to be observed

Thank You For Your Time Mass Spec